| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.4 L+₹48,260 (3.46%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹15.6 L+₹1.6 L (11.7%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | L4₹16.8 L+₹2.9 L (20.7%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance Rejected due to bidder not L1 | |
| 5 | L5₹17.8 L+₹3.9 L (27.6%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
2 Aug 2022, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIRS TO LT CABLE PANELS AND CONNECTED ITEMS AT ZONE B AHMEDABAD
2022_MES_537951_1
8264/E8
Open Tender
Civil Works
Works
180 days
GE (Army) Ahmedabad
As per NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹38,000
Yes
27 Sept 2022
14 Jul 2022
4 Aug 2022
14 Jul 2022
2 Aug 2022
19 Jul 2022
14 Jul 2022 - 19 Jul 2022
Amount
Dismantling / disconnecting the existing LT feeder pillar box / Indoor Panel with all outgoing / incoming supplies, making alternative arrangement for supply including minor diversion of cables as required & Supply, errect, test and commissioning in replacement Bus bar feeder pillar box of CPRI approved factory fabricated, dust & vermin proof including removal cable entry gland plate, powder coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3mm thick MS sheet, with incommer One number MCCB 250 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz and outgoing through Bus bar with angle iron legs of size 50 x 50 x 6mm, hinged door, locking arrangement with aluminium bus bar 400 Amps capacity, LED indicating lamp for RYB grouted, PCC 1:3:6 type C1 and duly powder coated painted with two coats of synthetic enamel paint over one coat of primer complete. (Drg / design of Panel shall be approved before placing order to concern factory in writing)
M&L in replacement pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer GI pipe dia 80 mm & inner GI pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water & connection with & including galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 & RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete.
Supply only Capacitor 415 V, AC 3Ø, 5 KVAR
Supply only Capacitor 415 V, AC 3Ø, 10 KVAR
Supply only Capacitor 415 V, AC 3Ø, 25 KVAR
Supply only MCB four pole 40 to 63 amps, 10 KA, 'C' series ISI marked.
Supply only High break HBC fuse link 315 Amps to 425 Amps, 80kA, 50Hz.
Supply only CT Coil class 1.0 of any CT ratio not exceeding 150/5.
M&L for servicing, repairing and welding to out door LT Panel / LT Feeder Piller box by (i) Cleaning with blower, (ii) Cleaning with CTC / Petrol (iii) Replacement of damaged copper / aluminium lugs (iv) Replacement of deteriorated copper wiring with existing sizes of cable (v) Cleaning and tightening of MCCB terminals (vi) Replacement and fixing of sheared rubber beadings (vii) Rectifying of loose connections of incoming and outgoing cables (viii) Painting two coat of smoke gray colour over one coat of primer and black paint on base channel after rubing with emery paper and making smooth finishes (ix) Providing of door locking arrangement with of sliding bolts on panel door (x) Proper welding of Panel door / roof (xi) Connecting / cleaning of earth wire /earth strip (x) Two coat of white distemper on foundation etc. complete.
S&F in replacement Digital AC voltmeter, 4 digit, 7 segment LED display, square type, input voltage 50 -480VAC including dismantling of unserviceable voltmeter and connecting the cable on existing panel complete
S&F in replacement Digital AC Ammeter 4 digit, 7 segment LED display, square type input voltage 50 -480VAC including dismantling of unserviceable ammeter and connecting the cable on existing panel complete.
S&F in replacemnt LED indication lamps R/Y/B with base on existing panel and connecting up the cables complete.
Supply, laying and testing in replacement of 185 sqmm 3.5 core LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete.
All as per Item no 14 above but for 120 sqmm 3.5 core.
All as per Item no 14 above but for 95 sqmm 3.5 core.
All as per Item no 14 above but for 70 sqmm 3.5 core.
All as per Item no 14 above but for 50 sqmm 3.5 core.
All as per Item no 14 above but for 35 sqmm 3.5 core.
All as per Item no 14 above but for 10 sqmm 4 core
All as per Item no 14 above but for 10 sqmm 2 core
Excavation in trenches nexc 1.5 mtr wide and nexc 1.5 mtr in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil complete.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete.
M&L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete
M&L in repairs GI tubing light grade 40 mm dia bore fixed on wall / pole laid in trenches / under road complete.
M&L in repairs GI tubing light grade 80 mm dia bore fixed on wall / pole laid in trenches / under road complete.
S&F in replacement PVC insulated & sheathed, multistranded copper conductor industrial cable 1.5 sqmm 3 core 1100 volt grade from Junction box to street light fitting complete.
M&L for horizontal boring through road / path / floor for passing UG cables by using tools trenchless technology for laying GI pipe complete
S&F in repairs 6 to 16 Sqmm 4 Core aluminium conductor 1100 volts using straight through cable joint kit out door type with jointing Epoxy joint based materials including necessary excavation / earthwork & filling back complete.
S&F in repairs 25 to 50 Sqmm 4 Core aluminium conductor 1100 volts using straight through cable joint kit out door type with jointing Epoxy joint based materials including necessary excavation / earthwork & filling back complete.
S&F in repairs 70 to 120 Sqmm 4 Core aluminium conductor 1100 volts using straight through cable joint kit out door type with jointing Epoxy joint based materials including necessary excavation / earthwork & filling back complete.
M&L for surface dressing in soft / loose soil n exc 15 cm deep, leveling the area & Site Clearance for cleaning of sub station open areas, removing grass, shrub, roots, brickbats etc complete.
M&L for spreading 40 mm graded stone aggregate deposited, spread and levelled in layers not exceeding 15 cm thick through out the sub station / out door panel foundation in open areas complete.
S&F in replacement MCCBs 125 amp, 4 pole with spreader links on both sides complete
S&F in replacement MCCBs 160 amp, 4 pole with spreader links on both sides complete
S&F in replacement MCCBs 250 amp, 4 pole with spreader links on both sides complete
S&F in replacement MCCBs 315 amp, 4 pole with spreader links on both sides complete
S&F in replacement MCCBs 400 amp, 4 pole with spreader links on both sides complete
Shree Karni Construction
Shree Krushna Supply Corporation
ALBA AC AND REF SERVICES
Electricals India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .