Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.4 LAccepted-AOC NEAR RELIANCE PETROL PUMP RAMGARH CANTT 829122 DIST RAMGARH JHARKHAND | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹26.4 L+₹4.1 L (18.2%)Rejected-Finance MAIN ROAD RAMGARH CANTT 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L-2 | Rejected-Finance REJECTED SINCE L-2 BIDDER | |
| 3 | Rejected-Technical 521 UBI ROAD SINGRAULI SINGRAULI SINGRAULI MADHYA PRADESH 486889 | SINGRAULI | MADHYA PRADESH | 486889 | - | Rejected-Technical confirmatory documents not submitted as per NIT |
Tender Value
Refer Docs
EMD Value
₹39,300
Closing Date
11 Jul 2022, 11:00 amClosed
SO(ENM)
GM UNIT KUJU
Shifting of 1MVA,11KV/3.3KV transformer from existing main substation to proposed Banwar weighbridge substation of Topa Project under Kuju Area.
2022_CCL_248166_1
GM (K)/EnM/eTender/22-23/65
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
KUJU
Please refer Tender documents.
2 documents required · 2 mandatory
₹39,300
20 May 2023
29 Jun 2022
12 Jul 2022
29 Jun 2022
11 Jul 2022
29 Jun 2022
29 Jun 2022 - 5 Jul 2022
Amount
11 KV O/H line
Erection of pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre
Supplying and erection of 11 KV pin insulator complete with largesteel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and socket typeand complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supply of G.I. wire
Erection of G.I. Wire No. 8 SWG including binding etc. as required
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter andabove including binding etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supply & Fixing of 11KV grade Isolator 630Amp
Supply & Fixing of 11KV Drop out fuse
Supplying and erection of bow stay set complete (galvanised)with 19/20 mm dia X 1.8 metres long stay rod, anchor plate ofsize 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundationincluding excavation and refilling and also with 0.6 m long braceof size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulleyfixed at one end of the brace as required.
Dismantling of over head lines comprising of copper/ aluminiumover head conductor, G.I. wire, cross arms, insulators etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing structure as required. Upto 120 sq. mm
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement,G.I. bolts, nuts, washers etc. as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/ fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required.
Supplying and erection of a set of cross bracing FRLSame workfor 11 KV over head line double pole structure having four membersfabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height ,complete with 50 mm X 6mm M.S. flat iron clamps, bolts andnuts including drilling holes for insulator pins, bolts and nuts etc(as per drawing) and painting with primer and finish paint as required.
Bus Bar Erection work
Supply & Fixing of Palm connector
Supply & Fixing of Bi-metalic connector
Supply & Fixing of Pipe to pipe connector
Supply & Fixing of Support Connector
Supply & Fixing of Post Insulator
Supply & Fixing of T- Connector
Supply & Fixing of Nut & Bolts
Supply & Fixing of 11KV grade Isolator 630Amp
Erection and commissioning of VCB
Erection and commissioning of Transformer
Cost of Alloy aluminum pipe 48.3 mm dia inner dia 40.8mm wall thk 3.6mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supply & Fixing of Aluminium Cable 35 sq mm single core
Supply & Fixing of Cable Lugs 35 sq mm
Brick work with common burnt clay modular bricks of class designation7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
Febrication and errection work of iron and steel platform, column, bracing housting. Placing etc for GOAB Structure, Bus Structure, Gate etc
Cement plaster skirting up to 30 cm height with cement mortar 1:3 finished with a floating coat of neart cement 18mm thick
Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m inwidth as well as 10 sqm on plan) including disposal of excavatedearth, lead upto 1.5 m, disposed earth to be levelledand neatly dressed. 2.8.1 Ordinary rock .
Sky Netting Work
Supply & Fixing of Aluminium Cable 35 sq mm single core
Supply & Fixing of Cable Lugs 35 sq mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Erection of pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre
Supply & Fixing of D’ iron clamp
Stay wire (7/4.00 mm dia)
Supply & fixing of cost of lightning conductor
Interlocking Work
Supply & Fixing of limit switch
Supply & Fixing of Auxilary Contractor
Supply & Fixing of Cable 2.5sq mm x 2 core copper
Total impact of GST for the purpose of CTC
Rajneesh Electricals
M.k. Traders
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .