| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹4.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹4.9 Cr+₹48.4 L (10.8%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹4.9 Cr+₹48.4 L (10.8%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹5.1 Cr+₹66.5 L (14.9%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹5.1 Cr+₹66.5 L (14.9%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹5.2 Cr+₹73.5 L (16.5%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹5.2 Cr+₹73.5 L (16.5%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹5.3 Cr+₹83.5 L (18.7%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹5.3 Cr+₹83.5 L (18.7%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹7.0 Cr
EMD Value
₹6.7 L
Closing Date
4 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
CONVERSION OF OVERHEAD LT LINES TO UG CABLE AND ALLIED EXTERNAL ELECTRIC WORK OF EAST AREA UNDER GE WEST BAREILLY
2024_MES_654301_1
CEBZ/BLY/T-03 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
BAREILLY
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE WEST BAREILLY
₹6.7 L
9 Dec 2024
16 May 2024
11 Sept 2024
16 May 2024
4 Sept 2024
22 Jul 2024
Amount
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete all as specified & directed. Note: "Excavation will be carried out by manual/ machnery are as directd by Engr-in-Charge".
Returning, filling in, in any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
Supply and laying XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 4 core complete all as specified and directed by Engr-in-Charge. Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per ser item No. 4 here-in-before but cross sectional area 16 Sqmm 4 core Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per ser item No. 4 here-in-before but cross sectional area25 Sqmm 4 core Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per ser item No. 4 here-in-before but cross sectional area 50 Sqmm 3½ core. Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per ser item No. 4 here-in-before but cross sectional area 95 Sqmm 3½ core Note: Cable must be purchased/ bought from directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per set item No .4 here-in-before but cross sectional area 120 Sqmm 3½ core. Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per set item No. 4 here-in-before but cross sectional area 185 Sqmm 3½ core. Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
All as per set item No. 4 here-in-before but cross sectional area 240 Sqmm 3½ core. Note: Cable must be purchased/ bought directly from manufacturer and CA number must be printed on cable drum/ cable and testing of Cable shall be done in presence of rep of accepting officer/ Engr- in - Charge during the manufacturing.
Supplying & Laying unreinforced precast concrete cable cover LV Type I flat size 250x 150 x 40 mm. Precast concrete cable cover shall comply with IS-5820-1970, specification factory made, complete all as specified and directed .
Supply and laying unreinforced precast concrete cable cover, class HV, Type 1 with peak ,size 300mm x 180mm x40 mm. Precast concrete cable cover shall comply with IS-5820-1970, specification for precast concrete cable cover and shall be of class and type as indicated. The concrete used in manufacturer of cable covers shall be of a grade not lower than M-20 complete all as specified and directed
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed.(Punned thickness shall only be measured for payment purpose)
Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable complete all as specified & directed.
S & F GI pipe light grade 80mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
All as per seritem No.16 here-in-before but 50mm bore size of pipe.
All as per seritem No.16 here-in-before but 40mm bore size of pipe.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 900 x 1200 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.00 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 400 amp 36 KA with multiple outgoing provission (Min 4 no ) suitable for up to 400 x3.5 core cable and Aluminium Bus bar of capacity 600 Amp with stainless stell nut bolts washers and spares holes with nut bolts on each bus bar complete all as specified & directed. Note:- (a) Testing of Panels/ feeder pillar shall be done in presence of rep of accepting officer/ Engr-in-Charge during the manufacturing . (b) AI existing cable of any size will be connected with suitable size of cable lugs, nut bolt etc as reqd at site are as directed. Cost of cable lugs, nut bolt etc included in above quoted rates. (c) Panel should have total 05 (five) Nos of common and unique key for all panels in this CA to be provided.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 900 x 1200 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.00 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 250 amp 36 KA with multiple outgoing provission (Min 4 no ) suitable for up to 240 x3.5 core cable and Al Bus bar of capacity 400 Amp with stainless stell nut bolts washers and spares holes with nut bolts on each bus bar and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete all as specified & directed. Note:- (a) Testing of Panels/ feeder pillar shall be done in presence of rep of accepting officer/ Engr-in-Charge during the manufacturing . (b) AI existing cable of any size will be conected with suitable size of cable lugs, nut bolt etc as reqd at site are as directed. Cost of cable lugs nut bolt etc included in above quoted rates.(c) Panel should have total 05 (five) Nos of common and unique key for all panels in this CA to be provided.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.00 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 160 amp 36 KA with multiple outgoing provission (Min 4 no ) suitable for up to 240 x3.5 core cable and Aluminium Bus bar of capacity 300 Amp-04 No with stainless steel nut bolts washers and spares holes with nut bolts on each bus bar and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete all as specified & directed. Note:- (a) Testing of Panels/ feeder pillar shall be done in presence of rep of accepting officer/ Engr-in-Charge during the manufacturing . (b) AI existing cable of any size will be conected with suitable size of cable lugs, nut bolt etc as reqd at site are as directed. Cost of cable lugs nut bolt etc included in above quoted rates.(c) Panel should have total 05 (five) Nos of common and unique key for all panels in this CA to be provided.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.00 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer MCCB of cap 125 amp 25 KA with multiple outgoing provission (Min 4 no ) suitable for up to 185 x3.5 core cable and Aluminium Bus bar of capacity 200 Amp-04 No with stainless steel nut bolts washers and spares holes with nut bolts on each bus bar and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete all as specified & directed. (a) Testing of Panels/ feeder pillar shall be done in presence of rep of accepting officer/ Engr-in-Charge during the manufacturing . (b) AI existing cable of any size will be conected with suitable size of cable lugs, nut bolt etc as reqd at site are as directed. Cost of cable lugs nut bolt etc included in above quoted rates. (c) Panel should have total 05 (five) Nos of common and unique key for all panels in this CA to be provided.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including 100 amp MCCB as incomer provission of multiple outgoing (Min 4 no ) suitable for up to 185 x3.5 core cable and Aluminium bus bar of capacity 200 Amp-04 No with stainless steel nut bolts washers and spares holes with nut bolts on each bus bar complete all as sepcified and directed incl making connection with thimbles etc complete all as specified & directed.
Making horizontal bore hole under road up to100mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 3 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making Red & white strips with synthetic enamelled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coats of white wash on PCC coping complete all as specified. Note : Pole serial no. will be as approved by GE/Engr-in-charge.
Material and labour for PCC 1:3:6 type C-2,using 40mm graded stone aggregate as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
Material and labour for PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces complete all as specified & directed.
Supply ,fixing ,commisioning and testing of Digital 24 Hr timer street light control panel of Max load 12 KW /3 PHASE 415 Volt complete with contractor rating 63Amp, MCB rating 63 Amp TPN including taking out old single phase timers complete all as specified and directed.
S&F of loop in loop out box of size 300x250x200mm cubical type fabricated with 2mm thick CRCA sheet (Heavy duty) and dust & vermin proof, IP-65 protection, back side openable, fixed on poles with nuts & bolts and front side openable with hinged shutter and locking arrangement suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of Aluminium bus bar of size 25 x 4mm duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators with provision for incoming and outgoing lighting cables conection duly crimping with suitable size thimbes including cutting of couping/ foundation for routing/ laying of cable for existing pole and making good after fixing of pipe/cable complete all as specified and directed.
S&F Multi Core Round PVC Insulated Copper Conductor (Flexible), industrial cables PVC Sheathed Cables Nominal area of conductor 1.50 Sqmm, 2 Core, 1100 volts conforming to IS: 694 complete all as specified and directed.
M&L for shifting of bracket and light from existing height / location to desired height as per specified including opening and reassembling the same all as directed.
Supply ,installation, testing and commissioning of 11 KV SCADA Compatible of 11 KV 630 Amps 21 kA for 3 second of SF 6 insulated ring main unit (RMU) 3 Way consist of motorised 2 load break switch and 01 ( one) No VCB suitable size replaceble bushing including neccessory foundation work as per manufacturere recommendation complete all as specified
Supply ,Laying and testing XLPE insulated screened PVC bedded ,galvanised steel strip or wire armoured ,electric power cable (heavy Duty) with stranded Aluminium conductor ,11000 volt Grade of size 120 sqmm 3 core complete all as specified and directed. Testing of Cable shall be done in presence of rep of accepting officer/ Engr-in-Charge during the manufacturing.
Supply,installing,commissioning and testing of LT panel outdoor type of size as per manufacturer recommendations not less than 2000 x 1500 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 70x70x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.00 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door front and rear openable and front mounted cabinet rod operated locking arrangement as directed before manufacturing the panel. Including taking out/ disconnection of old rusted LT panels with accessories complete all as specified and directed. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-
Dismantling of old OH ACSR Conductor or AAC Conductor complete all as specified and directed.
Dismantling of old insulators of any size/type complete all as specified and directed.
Dismantling of old cross Arms /MS Channels or Angle Iron of any size complete all as specified and directed.
Supply, fixing, testing and commissioning of heat shrinkable and Termination Joint jointing kit suitable for LT cable of size up to 50 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed.
All as per set item No 40 here-in-before but 95 to 120 Sqmm.
All as per set item No 40 here-in-before but 185 to 240 Sqmm.
M&L for dismentling of 4/2 pole HT stucture from ground lavel including openning of existing cable connection from GOD /Jumper ,opening of insulators ,,Angle iron frame complete and making good of disturebd surface.and connecting the HT cable with RMU complete all as specified and directed.
Supply, fixing, testing and commissioning of heat shrinkable straight through jointing kit suitable for LT cable of size up to 50 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed.
All as per set item No 44 here-in-before but 95 to 120 Sqmm.
All as per set item No 44 here-in-before but 185 to 240 Sqmm.
Supply, fixing, testing and commissioning of heat shrink end jointing kit suitable for HT cable of size up to 120 Sqmm, XLPE insulated, PVC sheathed armoured 11000 volts grade complete all as specified and directed.
Note:-Tenderers may note that amount of credit RS. 1496712.50 will be deducted form the total amount arrived at the time of acceptance of contract.
mayur enterprises (BID ID -3074356)
Leo Air and Power Solution pvt Ltd. (BID ID -3081945)
YAUK ENGINEERS (BID ID -3082600)
Sudhir Sharma Associates (BID ID -3078961)
M K ENGINEERS CO. (BID ID -3072301)
M/S SURAT SINGH AND SONS (BID ID -3082844)
M/s VINOD KUMAR SHARMA (BID ID -3082017)
TEAM ACC INFRABUILD PRIVATE LIMITED (BID ID -3083246)
B D Raizada Projects Pvt Ltd (BID ID -3082204)
Jeet Construction (BID ID -3082394)
Pioneer Enterprises (BID ID -3083287)
Vardhman Airport Solutions Private Limited (BID ID -3081394)
JASPAL SINGH & CONST (BID ID -3081118)
Rahul Construction India Pvt Ltd (BID ID -3077316)
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .