Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC BELIABATHAN PASCHIM BARDHAMAN | BELIABATHAN | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC AOC | |
| 2 | L2₹13.3 L+₹1.2 L (9.77%)Rejected-Finance 86 SOMNATH LAHIRI SARANI KOLKATA 700 053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹15.6 L+₹3.5 L (29.1%)Rejected-Finance 6 STATION ROAD BERHAMPORE MURSHIDABAD WEST BENGAL 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L3 | Rejected-Finance Rejected as L3 |
| Sl No | Description | Qty | Unit | JASODA REFRIGERATOR SERVICING CENTRE L3 | Lyric International L2 | ARATI ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following Cooling Capacity, Air Flow Rate and Minimum ISEER: 5.0, BEE level - 4-Star (min) comprising Indoor and Outdoor Units with factory charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) (Make: RR Kabel Ltd./Finolex/Havells) with suitable plug top (Make: Anchor), 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on a 230 V, 50 Hz (± tolerance as per the applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions, conforming to IS-1391 (Part-II) with all amendments. It shall be capable of efficient performance at outdoor ambient temperatures up to 50° C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections, including T&P & labour, etc., as required, complete in all respects as per the direction of EIC (Make: MITSUBISHI ELECTRIC / Daikin / O-General / Carrier)
Cooling Capacity: 5.2 KW (Minimum) and Air Flow Rate: 600 CFM (Minimum) | 4 | Sets | 68,000 ₹2,72,000 | 54,000 ₹2,16,000 Lowest | 58,000 ₹2,32,000 |
| 1.10 | Cooling Capacity: 6.1 KW (Minimum) and Air Flow Rate: 800 CFM (Minimum) | 12 | Sets | 78,000 ₹9,36,000 | 66,500 ₹7,98,000 Lowest | 68,000 ₹8,16,000 |
| 2.00 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 12 | Mtr | 200 ₹2,400 | 225 ₹2,700 | 100 ₹1,200 Lowest |
| 2.10 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 36 | Mtr | 150 ₹5,400 | 320 ₹11,520 | 100 ₹3,600 Lowest |
| 2.20 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 48 | Mtr | 180 ₹8,640 | 635 ₹30,480 | 100 ₹4,800 Lowest |
| 3.00 | S & F of the following additional items for length exceeding 3.5 mtr for complete installation and commissioning of the above AC machines. i) 2.5 sq. mm, 3/4 core copper cable (FRLS type) (Make: RR Kabel/Finolex/Havells). | 80 | Mtr | 200 ₹16,000 | 190 ₹15,200 | 100 ₹8,000 Lowest |
| 4.00 | Supply & laying Soft Drawn PVC Drain Pipe exceeding 3 mtr of 19 mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast) | 80 | Mtr | 100 ₹8,000 | 105 ₹8,400 | 10 ₹800 Lowest |
| 5.00 | Supply & Fixing 'FR' type Heat resistant 3" Insulation tape for Heat resistant | 240 | Mtr | 150 ₹36,000 | 100 ₹24,000 | 10 ₹2,400 Lowest |
| 6.00 | Taken down the Indoor & Outdoor Unit of Split type AC Machines (1.5/2 ton) from its existing installation place and refitting the same at authorities noted place within the campus of ANM(R ) Training School COM&JNM Hospital after servicing & repairing as required. | 3 | Nos | 1,500 ₹4,500 | 1,200 ₹3,600 | 100 ₹300 Lowest |
| 7.00 | Supplying and fixing 415 V, 63 A TPN SFU (Make: L&T/Havells/ABB/Siemens) with sheet steel enclosure on angle iron frame on wall with nuts, bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [SOR:D-3/4(a)] | 2 | Nos | 5,000 ₹10,000 Lowest | 12,900 ₹25,800 | 5,000 ₹10,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹24,205
Closing Date
5 Oct 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
SITC of new Split AC at the ANM (R ) within the campus of COM and JNM Hospital under Kalyani Electrical Sub-Division
2026_WBPWD_5023574_1
WBPWD/EE/NED/NIQ/e-T/04/ (3rd Call)26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
6 documents required · 6 mandatory
₹24,205
Nadia Electrical Division
26 Nov 2026
10 Sept 2026
7 Oct 2026
10 Sept 2026
5 Oct 2026
14 Sept 2026
14 Sept 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following Cooling Capacity, Air Flow Rate and Minimum ISEER: 5.0, BEE level - 4-Star (min) comprising Indoor and Outdoor Units with factory charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) (Make: RR Kabel Ltd./Finolex/Havells) with suitable plug top (Make: Anchor), 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on a 230 V, 50 Hz (± tolerance as per the applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions, conforming to IS-1391 (Part-II) with all amendments. It shall be capable of efficient performance at outdoor ambient temperatures up to 50° C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections, including T&P & labour, etc., as required, complete in all respects as per the direction of EIC (Make: MITSUBISHI ELECTRIC / Daikin / O-General / Carrier)
Cooling Capacity: 5.2 KW (Minimum) and Air Flow Rate: 600 CFM (Minimum) | 4 | Sets | - | - |
| 1.1 | Cooling Capacity: 6.1 KW (Minimum) and Air Flow Rate: 800 CFM (Minimum) | 12 | Sets | - | - |
| 2 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 12 | Mtr | - | - |
| 2.1 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 36 | Mtr | - | - |
| 2.2 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 48 | Mtr | - | - |
| 3 | S & F of the following additional items for length exceeding 3.5 mtr for complete installation and commissioning of the above AC machines. i) 2.5 sq. mm, 3/4 core copper cable (FRLS type) (Make: RR Kabel/Finolex/Havells). | 80 | Mtr | - | - |
| 4 | Supply & laying Soft Drawn PVC Drain Pipe exceeding 3 mtr of 19 mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast) | 80 | Mtr | - | - |
| 5 | Supply & Fixing 'FR' type Heat resistant 3" Insulation tape for Heat resistant | 240 | Mtr | - | - |
| 6 | Taken down the Indoor & Outdoor Unit of Split type AC Machines (1.5/2 ton) from its existing installation place and refitting the same at authorities noted place within the campus of ANM(R ) Training School COM&JNM Hospital after servicing & repairing as required. | 3 | Nos | - | - |
| 7 | Supplying and fixing 415 V, 63 A TPN SFU (Make: L&T/Havells/ABB/Siemens) with sheet steel enclosure on angle iron frame on wall with nuts, bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [SOR:D-3/4(a)] | 2 | Nos | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
form2911.pdf
Tender Documents • 0.50 MB
BOQ_5107630.xls
BOQ • 0.29 MB
Corrigendumdate.pdf
PDF • 0.32 MB
CorrigendumDt.pdf
PDF • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .