| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | L1 | Accepted-AOC Awarded by competent authority |
| Sl No | Description | Qty | Unit | shalu electricals L1 |
|---|---|---|---|---|
| 1.01 | Visit charges of skilled electrician and helper for tracing out the faults of wiring and electrical installation i/c testing etc complete as reqd. | 1 | Job | 5,600 ₹6,608 Lowest |
| 1.02 | Rewiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantaling as reqd.
(Group A) for servant quarter. | 10 | Nos | 6,050 ₹7,139 Lowest |
| 1.03 | Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required.
(a). 2x1.5 sq mm + 1x1.5 sq mm earth wire | 20 | Mtr | 6,800 ₹8,024 Lowest |
| 1.04 | (b). 2x2.5 sq mm + 1x2.5 sq mm earth wire | 20 | Mtr | 7,700 ₹9,086 Lowest |
| 1.05 | Providing prefabricated rain proof, powder coated power distribution cubicle made out of 16 swg CRCA sheet, bakelite sheet in background and providing 3 nos 100 amp kit kat fuses and one neutral link, 100 amp on load change over switch, RYB LED indicators, cable entry holes at bottom and space for 3 phase energy meter, sign writing and mounting on wall / grouting on MS angle stand etc complete as reqd. | 1 | Job | 40,200 ₹47,436 Lowest |
| 1.06 | Providing 3 phase 10 to 60 amp rating energy meter i/c connection, testing etc complete as reqd. | 1 | Job | 6,800 ₹8,024 Lowest |
| 1.07 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as reqd. (But without MCB/ RCCB/ Isolator)
(a). 4 way (4+12) double door | 4 | Nos | 17,200 ₹20,296 Lowest |
| 1.08 | Supplying and fixing 5A to 32A rating 240/415 Volt 10KA 'C' curve single pole miniature circuit beaker, suitable for inductive loadof following polesin the existing MCB DB complete with connection, testing and commissioning etc as reqd. | 48 | Nos. | 12,768 ₹15,066.24 Lowest |
| 1.09 | Supplying and fixing 63 A rating four pole 415 volt isolator in the existing MCBDB complete with connection, testing and commissioning etc as reqd. | 4 | Nos. | 4,600 ₹5,428 Lowest |
| 1.10 | Providing globe shape fiber compound light suitable to mount on 3 meter pole having lamp holder and 25 watt LED lamp i/c connection, testing etc complete as reqd. (M/s Havells / Philips or ss make) | 12 | Nos | 28,200 ₹33,276 Lowest |
Tender Value
₹2.0 L
EMD Value
₹3,942
Closing Date
23 Jul 2025, 4:00 pmClosed
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Repairing of electrical wiring , switch boards and installation of 3 phase electric sub meter board and compound light at IQ building at Tikhampur in Ballia OA.
2025_BSNL_241213_1
21/TED/GKP/2025-2026
Open Tender
Electrical Works
Item Rate
45 days
Ballia
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹3,942
16 Sept 2025
14 Jul 2025
24 Jul 2025
14 Jul 2025
23 Jul 2025
14 Jul 2025
Visit charges of skilled electrician and helper for tracing out the faults of wiring and electrical installation i/c testing etc complete as reqd.
Rewiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantaling as reqd. (Group A) for servant quarter.
Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required. (a). 2x1.5 sq mm + 1x1.5 sq mm earth wire
(b). 2x2.5 sq mm + 1x2.5 sq mm earth wire
Providing prefabricated rain proof, powder coated power distribution cubicle made out of 16 swg CRCA sheet, bakelite sheet in background and providing 3 nos 100 amp kit kat fuses and one neutral link, 100 amp on load change over switch, RYB LED indicators, cable entry holes at bottom and space for 3 phase energy meter, sign writing and mounting on wall / grouting on MS angle stand etc complete as reqd.
Providing 3 phase 10 to 60 amp rating energy meter i/c connection, testing etc complete as reqd.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as reqd. (But without MCB/ RCCB/ Isolator) (a). 4 way (4+12) double door
Supplying and fixing 5A to 32A rating 240/415 Volt 10KA 'C' curve single pole miniature circuit beaker, suitable for inductive loadof following polesin the existing MCB DB complete with connection, testing and commissioning etc as reqd.
Supplying and fixing 63 A rating four pole 415 volt isolator in the existing MCBDB complete with connection, testing and commissioning etc as reqd.
Providing globe shape fiber compound light suitable to mount on 3 meter pole having lamp holder and 25 watt LED lamp i/c connection, testing etc complete as reqd. (M/s Havells / Philips or ss make)
Supplying and fixing 3 pin 5 Amp ceiling rose on the existing junction box / wooden block i/c connections etc as reqd.
Supplying and fixingfollowing piano type switch/socket on the existing switch box / cover i/c connections etc as reqd. (a). 5/6 amp. Switch
(b). 15/16 amp switch
{c}. 3 pin 5/6 A socket outlet
(d). 6 pin 15/16 A socket outlet
(e). 4 inch dia round phenolic laminated sheet
Providing and laying 2x4 sq mm aluminium conductor PVC insulated PVC sheathed cable on surface of wall i/c clipping and connections etc as reqd.
Providing and fixing DP enclosure for compound light with 6 amp DPMCB having cover plate i/c grouting and fixing complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .