| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹2.0 L+₹4,112 (2.06%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹2.0 L+₹4,554 (2.29%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VEE AUTO TRADERS L3 | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L1 | M/S UK MECH AND ELECT ENGG WORKS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Complete Cleaning servicing of VRV units of air conditioning system installed at terrace of New Emergency Block of GMCH, Jammu by way of disconnecting all the incoming electrical connections and then chemical wet servicing for heating effectiveness of the whole unit and including all outdoor unit, indoor units, heating coils servicing, electrical servicing, greasing/oiling of motors etc. The job also includes identification of faults in the system i.e gas leakage etc for its further rectifications and also repairing thr damaged pipes by copper brezing method wherever required so as to make the complete system fully functional in the interest of patient care. The job further includes Complete cleaning/servicing and chemical cleaning of the evaporater/ heating coil by spraying chemical cleaner over the coil surface using jet cleaner pump on both sides of coil for at least 20 minutes and then spraying the coil with fresh water till the foam goes away or till the chemical is washed off and the cleaning process is repeated till the fins and cooling coil are totally cleaned. . Checking the refrigeration control system for operation and adjusting the settings and Checking the refrigeration system, motor and starters for performance and ensuring healthy condition of the plant.. Overhauling of all the required components of the equipment at site or in workshop as and when required. The job also involves refilling of refrigerant gas R410 as and whwn required and also replacement of the overheated/burnt/damaged MNX-A2-04 No’s, VSP Single phase preventer-02 No’s with new ones and also replacement of all the damaged wiring in the VRV units . The job further includes repair of control units of VRV’s wherever required The Job also involves repeated cleaning /servicing of all the units as and when required and also cost of technician when required throughout the season as per the recommendation and instructions of the site Engineer. Complete job includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials & works required for execution of job . | 12 | nos. | 0.01 ₹1,79,982 | 0.01 ₹1,75,824 Lowest | 0 ₹1,79,400 |
| 2.00 | Repair and Servicing of ceiling suspended Air Handling Units installed in OT’s of Emergency Block of GMCH Jammu. The job includes dismantling main electrical Supply and then replacing all the burnt electrical wiring with new wiring with the help of proper thimbling and taping. The Job includes repair to leakage of MS chillar pipe lines connected to ceiling suspended units by draining out all the water from the chillar pipeline and then removing the damaged / rusted portion with help of cutter and fitting the same specification pipe by welding/brazing at different places wherever required to stop the leakage of water and then insulation is provided on the chillar pipeline to avoid the temperature loss from the chilled water. The job includes complete cleaning of coils by spraying chemical till the foam goes off and the cleaning process is repeated till the cooling coils are totally cleaned . The job involves repair to water pipeline inlet and outlet by way of replacing the damaged solenoid Valves with new brass connecters-02 No’s after proper brazing and leak detection test Complete job includes cost of Labour, transportation, material and all types of taxes etc | 2 | nos. | 0.01 ₹23,760 | 0.01 ₹23,364 Lowest | 0 ₹23,900 |
Tender Value
₹2.1 L
EMD Value
₹5,000
Closing Date
4 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Complete Cleaning Servicing of VRV Units and allied works for upcoming summer Season installed at New Emergency Block of GMCH Jammu
2026_PWDJK_308672_1
MHDJ/e-NIT 18 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹5,000
19 May 2026
25 Apr 2026
5 May 2026
25 Apr 2026
4 May 2026
28 Apr 2026
25 Apr 2026 - 4 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Complete Cleaning/Servicing of VRV Units and allied works (for upcoming summer Season) installed at New Emergency Block of GMCH Jammu..
MHDJ/e-NIT 18 of 2026-27 Dated: 25.04.2026 Due : 04.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Complete Cleaning servicing of VRV units of air conditioning system installed at terrace of New Emergency Block of GMCH, Jammu by way of disconnecting all the incoming electrical connections and then chemical wet servicing for heating effectiveness of the whole unit and including all outdoor unit, indoor units, heating coils servicing, electrical servicing, greasing/oiling of motors etc. The job also includes identification of faults in the system i.e gas leakage etc for its further rectifications and also repairing thr damaged pipes by copper brezing method wherever required so as to make the complete system fully functional in the interest of patient care. The job further includes Complete cleaning/servicing and chemical cleaning of the evaporater/ heating coil by spraying chemical cleaner over the coil surface using jet cleaner pump on both sides of coil for at least 20 minutes and then spraying the coil with fresh water till the foam goes away or till the chemical is washed off and the cleaning process is repeated till the fins and cooling coil are totally cleaned. . Checking the refrigeration control system for operation and adjusting the settings and Checking the refrigeration system, motor and starters for performance and ensuring healthy condition of the plant.. Overhauling of all the required components of the equipment at site or in workshop as and when required. The job also involves refilling of refrigerant gas R410 as and whwn required and also replacement of the overheated/burnt/damaged MNX-A2-04 No’s, VSP Single phase preventer-02 No’s with new ones and also replacement of all the damaged wiring in the VRV units . The job further includes repair of control units of VRV’s wherever required The Job also involves repeated cleaning /servicing of all the units as and when required and also cost of technician when required throughout the season as per the recommendation and instructions of the site Engineer. Complete job includes cost of material, all kinds of taxes, labour charges, tools & tackles, other unforeseen materials & works required for execution of job . 12 nos. Excess(+) Full Conversion INR
2 Repair and Servicing of ceiling suspended Air Handling Units installed in OT’s of Emergency Block of GMCH Jammu. The job includes dismantling main electrical Supply and then replacing all the burnt electrical wiring with new wiring with the help of proper thimbling and taping. The Job includes repair to leakage of MS chillar pipe lines connected to ceiling suspended units by draining out all the water from the chillar pipeline and then removing the damaged / rusted portion with help of cutter and fitting the same specification pipe by welding/brazing at different places wherever required to stop the leakage of water and then insulation is provided on the chillar pipeline to avoid the temperature loss from the chilled water. The job includes complete cleaning of coils by spraying chemical till the foam goes off and the cleaning process is repeated till the cooling coils are totally cleaned . The job involves repair to water pipeline inlet and outlet by way of replacing the damaged solenoid Valves with new brass connecters-02 No’s after proper brazing and leak detection test Complete job includes cost of Labour, transportation, material and all types of taxes etc 2 nos. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
BOQ_1000048.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .