| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹9.1 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L4 |
| 4 | Rejected-Technical | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | STANDARD ELECTRONICS L1 | R.P.ELECTRONICS L4 | Eastern Commerce L3 | R.S.COOLING AND ELECTRICAL SERVICE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Providing of vertical Split AC unit of cooling capacity not less than 3.65TR or 10950 Kcl/hr or 43800 BThu/h or 12775 watt with hermetically sealed compressor operating on R-32/R-410 A non CFC or equivalent refrigerants suitable for floor mounting suitable for operation on 3 phase AC supply, capable of performing: - cooling, dehumidifying, air circulation, filtering etc complete as per direction of the Engineer-in-Charge. | 3 | No | 1,22,000 ₹3.7 L | 1,50,000 ₹4.5 L | 1,69,780 ₹5.1 L | 1,42,400 ₹4.3 L |
| 2.00 | Installation and commissioning of vertical Split AC unit with vaccumising, nitrogen pressure testing, first charge of refrigerant including providing refrigerant & cable connection from MCB to outdoor/indoor etc (upto 3 mtr) complete as per direction of the Engineer-in-Charge. | 3 | No | 5,000 ₹15,000 | 8,000 ₹24,000 | 8,300 ₹24,900 | 6,500 ₹19,500 |
| 3.00 | Providing & fitting fixing of different sizes of hard drawn pure copper pipe for suction and liquid line between indoor & outdoor unit along with proper insulation by nitrile wrappings etc complete as per direction of the Engineer-in-Charge.
3/8"(9.5 mm) or nearest dia as per manufacturers design | 30 | Mtr. | 500 ₹15,000 | 600 ₹18,000 | 500 ₹15,000 | 850 ₹25,500 |
| 3.01 | 5/8"(15.8 mm) or nearest dia as per manufacturers design. | 30 | Mtr. | 550 ₹16,500 | 900 ₹27,000 | 800 ₹24,000 | 920 ₹27,600 |
| 4.00 | Providing & fitting fixing of VI pad for outdoor unit for vertical Split Ac unit as per direction of the Engineer-in-Charge | 3 | Sets | 500 ₹1,500 | 800 ₹2,400 | 500 ₹1,500 | 100 ₹300 |
| 5.00 | Providing & fitting fixing of additional length(beyond 3 mtr) electric control cable (4C x 4.00 mm) suitable for connection between MCB to outdoor unit /indoor unit etc. complete as per direction of the Engineer-in-Charge. | 24 | Mtr. | 600 ₹14,400 | 300 ₹7,200 | 110 ₹2,640 | 280 ₹6,720 |
| 6.00 | Providing & fitting fixing of 16 amps TOP for connection of indoor unit & MCB as per direction of the Engineer-in-Charge. | 3 | No | 130 ₹390 | 100 ₹300 | 100 ₹300 | 120 ₹360 |
| 7.00 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge | 7 | No | 55,000 ₹3.9 L | 60,000 ₹4.2 L | 56,800 ₹4.0 L | 57,500 ₹4.0 L |
| 8.00 | Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 1 | No | 42,000 ₹42,000 | 42,000 ₹42,000 | 38,000 ₹38,000 | 44,500 ₹44,500 |
| 9.00 | Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge | 8 | No | 1,750 ₹14,000 | 4,500 ₹36,000 | 2,500 ₹20,000 | 2,450 ₹19,600 |
Tender Value
₹10.9 L
EMD Value
₹21,813
Closing Date
17 Apr 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing fitting fixing of Air Conditioning machines of One no Type VII quarter at Secretariat quarter complex vallukiya tilla Agartala Tripura W
2025_CEPWD_59993_1
105 _EE_DNIeT_MECHDIVN_AGT_2425
Open Tender
Electrical Works
90 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹21,813
19 Mar 2026
2 Apr 2025
17 Apr 2025
2 Apr 2025
17 Apr 2025
2 Apr 2025
Amount
Providing of vertical Split AC unit of cooling capacity not less than 3.65TR or 10950 Kcl/hr or 43800 BThu/h or 12775 watt with hermetically sealed compressor operating on R-32/R-410 A non CFC or equivalent refrigerants suitable for floor mounting suitable for operation on 3 phase AC supply, capable of performing: - cooling, dehumidifying, air circulation, filtering etc complete as per direction of the Engineer-in-Charge.
Installation and commissioning of vertical Split AC unit with vaccumising, nitrogen pressure testing, first charge of refrigerant including providing refrigerant & cable connection from MCB to outdoor/indoor etc (upto 3 mtr) complete as per direction of the Engineer-in-Charge.
Providing & fitting fixing of different sizes of hard drawn pure copper pipe for suction and liquid line between indoor & outdoor unit along with proper insulation by nitrile wrappings etc complete as per direction of the Engineer-in-Charge. 3/8"(9.5 mm) or nearest dia as per manufacturers design
5/8"(15.8 mm) or nearest dia as per manufacturers design.
Providing & fitting fixing of VI pad for outdoor unit for vertical Split Ac unit as per direction of the Engineer-in-Charge
Providing & fitting fixing of additional length(beyond 3 mtr) electric control cable (4C x 4.00 mm) suitable for connection between MCB to outdoor unit /indoor unit etc. complete as per direction of the Engineer-in-Charge.
Providing & fitting fixing of 16 amps TOP for connection of indoor unit & MCB as per direction of the Engineer-in-Charge.
Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge
Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge.
Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable.
Providing & Fitting fixing of 1" UPVC drain pipe as per direction of the Engineer-in-Charge.
R.S.COOLING AND ELECTRICAL SERVICE (BID ID -172991)
Eastern Commerce (BID ID -172954)
R.P.ELECTRONICS (BID ID -172903)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61016.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid