Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹29.9 L+₹12,628 (0.42%)Rejected-Finance | L2 | Rejected-Finance being not L1 bidder | |
| 3 | L3₹34.4 L+₹4.6 L (15.5%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L3 | Rejected-Finance being not L1 bidder | |
| 4 | L4₹39.9 L+₹10.2 L (34.3%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L4 | Rejected-Finance being not L1 bidder | |
| 5 | L5₹43.1 L+₹13.3 L (44.8%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance being not L1 bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
22 Jun 2023, 6:00 pmClosed
Garrison Engineer Utility-I
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF HT DISTR SYSTEM, UG CABLE, DG SET, DISTR TRANSFORMERS, RMUS, VCBS, CALIBRATION OF RELAY, LT PANELS, STREET, HIGHMAST, GARDEN LIGHTS AND CERTAIN ALLIED WORKS AT INHS KALYANI AND MMT UNDER AGE E/M NO-I OF GE (UTILITY-I) VISAKHAPATNAM
2023_MES_598365_1
8544/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
5 documents required · 5 mandatory
₹500
Garrison Engineer Utility-I
₹95,000
Yes
30 Jun 2023
25 May 2023
24 Jun 2023
25 May 2023
22 Jun 2023
9 Jun 2023
Amount
S&F LED street light fitting of capacity 90 watt, IP-66 (minimum), integrated type with high efficiency electronic driver, SPD of capaciity 10 KV, pressure die cast aluminium housing with toughened glass cover, internally prewired and including electrically connecting & taking down old unserviceable fittings from any position at a height upto 9 m complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj Note:- Supply of new GI Pipe bracket if required shall be measured and paid seperately under relevant item.
Taking down defective street light fitting of any make / type / capacity from top of pole / walls / high mast at a height not less than 7.0 m, at any location, for repair work and re-fixing the same after repair work including testing and commissioning complete all as specified and directed. Note:- (i) M&L for Items like ballast, lamp, ignitor, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items. However rate quoted shall deemed to include cost of minor spares like nut bolts, circle clips, clamps etc (if reqd) (ii) Necessary T&P like ladders etc required to take the fitting down shall be arranged by the contractor.
S&F in repairs electronic driver of make as per existing, suitable for 90 to 120W street light / flood light / post top lantern complete all as specified and directed. Note:-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
All as per serial Item No. 3.00 above but suitable for 45 to 60 W
S&F LED flood light fitting of capacity 150 watt, IP-66 (minimum) with luminous efficacy 100 Lumen/watt (minimum), SPD of capaciity 10 KV, pressure die cast aluminium housing, toughened glass cover, internally prewired and including electrically connecting & all other necessary fixing accessories such as 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers including painting to clamps with two coat of aluminium paint over a coat of red oxide primer & taking down old unserviceable fittings from any position at a height upto 9 m complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
S&F in repair 40 watt LED post top lantern with polycarbonate opal diffuser, pressure die cast aluminium housing, IP-65 (minimum), high efficient constant current electronic driver including electrically connecting complete all as specified and directed. Make :- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
M&L preparation of old painted surface of existing 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the colour code, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F in repair weather proof cable junction box of size not less than 210 mm x 310 mm x 116 mm with terminals, IP 66 (minimum), suitable for outdoor installation, suitable for 10 to 25 sqmm cable, including 01 No 5/6 Amp MCB, 100 Amp rated 3 pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers complete all as specified and directed. Make :- Hensel / Sintex Industries Ltd. / C&S electric Ltd. / National
S&F in repair PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc, complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
S&F in repair three phase, automatic street light control panel with and including astronommical timer switch for automatic switching on / off street light as per set time through programmable switch, 110A, TP power contactor, suitable capacity MCB / MCCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd / Indo Asian
Clearing away all bushes, small plants, grass, vegetation, saplings, shrubs, brushwood, undergrowth, roots upto root level including surface dressing n.exc 15 cm deep around and surroundings areas of E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & Misc E/M installations etc) and removing rubbish / debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed.
M&L for carrying out 'B' check for DG set of capacity 400 KVA after 06 months or 250 hrs running, whichever is earlier as per manufacturer's recommendation including replacement of fuel filters, air filters, oil filters, 'O' rings, engine oil, gasket, coolant etc complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. Make of Engine: Cummins / Kirloskar Note:- Unit rates quoted against this item shall be considered to include cost of fuel filters, air filters, oil filters, 'O' rings, gasket, engine oil & coolant etc.
All as per Sl item No 12 above but for 320 KVA DG Set.
All as per Sl item No 12 above but for 250 KVA DG Set.
All as per Sl item No 12 above but for 200 KVA DG Set.
All as per Sl item No 12 above but for 140 KVA DG Set.
All as per Sl item No 12 above but for 100 KVA DG Set.
All as per Sl item No 12 above but for 62.5 KVA DG Set.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I, connected to earthing test point including dismantling existing earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L for strip opening AMF panel of 100 to 200 KVA capacity DG set, checking, inspecting, calibrating AMF panel, replacing the burnt copper wiring with suitable flexible copper wire, inspecting the contactor coils & replacing the defective coils, cleaning the fixed / moving contacts with CTC complete including setting of AVR of Alternator including testing & commissioning all as specified and directed.
All as per Sl item No 20.00 above but for 250 to 400 KVA capacity DG set.
S&F in repair on-load change over switch 630 Amp capacity four pole 415 volts, front operating handle complete all as specified and directed. Make:- ABB /L & T / Legrand / Siemens / Schnieder / Havells India Ltd. / Indo Asian
All as per Sl item No 22.00 above but 400 Amp capacity
M&L for repair and servicing of self starters including replacement of commutator, carbon brush set with holder, king pin holder, armature, check nut, body screws, clutch plate assembly and solenoid switch etc suitable for 320 to 400 KVA DG Set complete all as specified and as directed by Engr-in-Charge.
All as per Sl item No 24.00 above but for 200 to 250 KVA DG Set.
M&L for repair and servicing of charging alternator including replacement of diode set with holders, bushes, bearing, varnishing, reassembling etc for 320/400 KVA DG Set complete all as per manufacturer instructions and as directed by Engr-in-Charge.
All as per Sl item No 26.00 above but for 140 to 250 KVA DG Set.
S&F in repair 12 volt, 180 AH battery including terminal clamps, copper lead of suitable length complete all as specified and directed. Make:- Exide / Amron / Amara raja / Luminous
S&F in repair 12 volt, 90 AH battery including terminal clamps, copper lead of suitable length complete all as specified and directed. Make:- Exide / Amron / Amara raja / Luminous
S&F in repair 12 volt, 65 AH battery including terminal clamps, copper lead of suitable length complete all as specified and directed. Make:- Exide / Amron / Amara raja / Luminous
Supply and topping up of engine oil 20W40 complete all as specified and as directed by Engr-in-Charge. Make: Castrol / Servo / HPCL
S&F in repair complete fuel oil hose pipe set with clamp / clip etc suitable for upto 400 KVA DG Set complete all as specified and as directed by Engr-in-Charge.
Supply, calibrating, installing, setting, testing & commissioning of AVR panel for 62.5 - 400 KVA DG set, 415V, 3 phase, 4 wire system, Digital type, Voltage regulation: 10% of rated voltage, frequency setting: 50/60 cycle, stability, doom settings, excitation voltage, current to be matched with OEM instructions complete all as specified and as directed by Engr-in-Charge.
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arresting the leaking core by brazing / dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, re-fixing the same including testing and spray painting with one coat of synthetic enamel paint for DG set of 62.5 to 400KVA capacity complete all as specified and as directed by Engr-in-Charge.
S&F in repair earth continuity conductor or main earthing lead using 32 x 6 mm copper strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F in repair power contactor, 400Amps, 4Pole Contactor, 415V, + 2NO 2NC Contact, Conforming to IS / IEC 60947-4-1 & IEC 60947-4-13 all complete as specified and as directed by Engr-in-Charge. Make: L&T / Indoasian / Legrand / HPL / C&S / ABB / Siemens / Schneider
S&F in repair 50 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
All as per Sl Item No. 37.00 but 100 mm bore .
All as per Sl Item No. 37.00 but 40 mm bore .
Comprehensive maintenance of 60 KVA UPS installed at every 3 months or as and when directed by Enger-in-Charge as per requirement by a qualified technician of OEM, comprising of the following outlined services :- Notes:- (i) The Contractors technical team shall visit the installation site for periodic preventive maintenance, check up of the UPS system and batteries every month. System shall be cleaned and general performance will be checked and report shall be submitted to the Engr-in-Charge. (ii) DC back up source will be maintained by applying white petroleum jelly, checking / servicing of batteries including toping up of distilled water etc as applicable. (iii) Apart from the periodic preventive maintenance visits, all breakdown calls for the systems covered under the contract shall be attended / troubleshooted including Sunday and holidays. (iv) Cost of all the minor spares (including Inverter Transformer) to put the UPS in working condition shall deemed to be included in unit rate quoted complete however supply of major components shall be measured under relevant Items. (v) Response time during normal working hours shall not be more than 4 Hrs from the time of receipt of complaint and the resolution time shall be maximum 48 hrs, based on the nature of complaint and replacement of components and boards. vi) Standby UPS of similar capacity shall be provided by the contractor on site till the repair of UPS. Transport / rent of the same shall be borne by the contractor during the contract period and unit rate quoted shall deemed to include this aspect complete all as directed by the Engr-in-charge.
S&F in repair ATS ( Automatic transfer Switch ) of 250 Amps rating, 415 V , 50 Hz AC supply in AMF Panel complete all as specified and as directed. Make : L&T/ Schneider / Legrand / ABB / Siemens / C&S
S&F in repair danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT compete all as specified and as directed.
S&F in repair danger notice plate of size 20 x 15 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for LT complete all as specified and as directed.
Dismantling the spring charging mechanism of the VCB, checking the entire mechanism for any worn / crack / bent / block / loose parts etc. for the following:- (i) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required. (ii) Checking / servicing of ratchet wheel assembly, driving and charging parts. (iii) Checking the auxiliary switch, its contacts for proper functional operation. (iv) Checking & servicing of raising / lowering mechanism and its locking system for proper functioning. (v) Checking & servicing of shutter assembly for its automatic opening / closing. Note:-The items like nuts, bolts, spring washers, petroleum jelly, CTC etc required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted against this item.
M&L for decarburizing / cleaning complete of 11KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber, checking the bus bar and circuit spouts, CTs/ PTs for any arcing / tracks, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying becktol red varnish, cleaning of metering and relay chamber, checking & replacement of burnt wires, checking & tightening the nuts, bolts & thimbles of incoming / outgoing system & all connections to arrest the loose contacts, supply & replacement of defective rusted bolts & nuts, applying mono-plast compound at bus bar joints after tightening all joints / connections complete all as specified and as directed.
Disconnect and taking out IED / IDMT / Numeric / Microprocessor based relay of any type & make from 11 KV HT panel, cleaning the contacts, IED configuration, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment / setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune / synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed. Note:- (i) Arrangement of necessary testing / calibration kits, testing equipments, tools etc. shall be done by contractor and cost of the same shalll deemed to be included in the unit rate quoted. (ii) Testing & tuning shall be carried out in the presence of representative of the accepting officer to the entire satisfaction of the rep of GE.
S&F in repair CTs epoxy cast resin , with primary Current 100A - 50A / 1 A - 1A , Secondary current 1A , Dual core , Dual Ratio, protection core Class 5P10 & Metering core - Class 0.5 , 2.5 VA Suitable for existing RMU (Make Siemens) complete all as specified and as directed.
S&F in repair LED Indication Lamps suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair LED type push button actuators suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Shunt trip coil 110 V DC / 220 V DC suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Breaker Control Switch suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Control Circuit fuses 2A to 63A suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair HRC fuses for PT primary side suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Ammeter 240 deg 144 sq. mm suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Voltmeter 240 deg 144 sq. mm suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair Multi function meter , Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc) class 1/.5 with RS485 port for communication in Modbus protocol complete all as specified and as directed by Engr-in-Charge. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair panel Space Heater 2 KW rating suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge.
S&F in repair Digital Temperature Indicator alongwith thermostat suitable for 11KV VCB panel as per existing complete all as specified and as directed by Engr-in-Charge. Make :- L&T / Havells / HPL / AE / Schneider
S&F in repair bus bar support DMC insulator for VCB panel complete all as specified and as directed by Engr-in-Charge.
S&F in repair vacuum interrupter type VG2 suitable for 11KV VCB panel complete all as specified and as directed by Engr-in-Charge.
S&F in repair Spring Charging motor with gear box universal motor with gear box 230 AC/DC 110 V AC/DC suitable for 11KV VCB panel complete all as specified and as directed by Engr-in-Charge.
S&F in repair Ratchet wheel suitable for 11KV VCB panel complete all as specified and as directed by Engr-in-Charge.
S&F in repair 1250 A finger type isolating tulip contacts suitable for 11KV VCB panel complete all as specified and as directed by Engr-in-Charge.
M&L for control wiring inside control chamber of 11 KV VCB with 1 Core, 2.5Sqmm Copper wire with proper ferules & appropriate Lugs complete all as specified and as directed.
S&F in repair bus bar spout suitable for 11kV VCB & make as per OEM complete all as specified and as directed.
S&F in repair 11 KV potential transformer TYPE VIR= 11000/RT3/110/RT3/110/RT3V, VA=100/50 VF; 1.2CONT & 1.9 for 8 Hours, voltage transformer single phase type HSV/IL, 12/28/75 KV complete all as specified and as directed. Make : L&T / GE / Siemens / ABB / C&S
S&F in repair, calibrating, testing & commissioning of Micro processor feeder protection relay, range - 0.01 In - 8 In, protection setting- 2 set, protecting circuit correct - 1 Amps & 5 Amps sets, records history- 5Nos, min 6 Analog output, with protections viz. feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), 67 P (3 Phase directional Over current), 6/N (Earth fault directional over current), 51V (Voltage controlled over current) 37 (3 phase under current), 46(Negative phase sequence over current), 59N (Residual over voltage), 49 (Thermal over load), 79(Auto reclose), 50BF( Circuit breaker failure detection), Cold Load pickup, Inrush blocking, Relay will be on MODBUS protocol with LCD display, trip, circuit healthy, alarm, other assignable indication, Auxiliary supply : 110V DC complete all as specified and directed. Make:- ABB / Areva / L&T / Schnieder / GE / BCH / C&S / Siemens
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down existing cable complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
M&L cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 185 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
S&F in repair cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
S&F in repair cable jointing kit for 11 KV (Earthed) grade 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for indoor termination, heat shrink type joint complete with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the burst transformer/Voltage stabiliser indoor/ outdoor type of capacity 500 KVA to 750 KVA, 11 KV/ 0.433 KV, step down any make for carrying out complete overhauling which shall comprise of the following:- a) M&L for lifting, transporting, handling, the transformer to workshop (including back to the original location after complete overhauling) and opening top cover of the transformer by unscrewing nuts, bolts, washers etc. including disconnecting core assembly from HT/ LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. b) Conducting the tests on core and windings as per IS like ratio, magnetic imbalance, short circuit etc. in presence of Engr-in-Charge and test results shall be signed both by the contractor and Engineer -in-Charge and kept on record. Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to Department. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding / re-insulation of HT/ LT (primary / secondary) coils, bushes, studs, Transformer oil,cable box, replacement of buchholtz relay / MOG if any etc will be measured and paid separately.
M&L for decarburizing / cleaning complete LT 415 Volts 3 phase panel / bus bar chamber with electrical connections, bus bar, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying becktol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of incoming / outgoing system complete including replacement of defective rusted bolts & nuts all as specified and directed.
S&F MCCB 3 pole 63 to 100 Amp, breaking capacity 16 kA, Ics = 100% Icu, thermal megnatic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand / Indo Asian (Optipower)
All as per Sl item No. 75.00 above but 200 Amp & breaking capacity 35 kA
S&F MCCB 4 pole 250 Amp, breaking capacity 35/36 kA, Ics = 100% Icu, microprocessor release type with adjustable overload setting (0.4-1.0 ln), adjustable short circuit setting (1.5-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand / Indo Asian (Optipower)
All as per Sl item No. 77.00 above but 400 Amp
M&L for removing electrical connections of 3 / 4 pole Air circuit breaker of capacity 400 to 1600 Amps, 415 V, 50 HZ of any make, strip opening of the ACB, inspecting the parts for serviceability / overhauling complete and carrying out following repairs / maintenance :- a) Cleaning insulation parts including bushings with CTC solution. b) Checking alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Checking the bolts, nuts, washers, cotter pins and all terminal connections are in place and tight, replacing worn-out parts. d) Checking arc chutes for damage and replacing damaged parts. e) Cleaning and lubricating the operating mechanism with light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for wearing surfaces, adjusting breaker operating mechanism all as per manufacturer's instructional manual, replacing the same if there is excessive wear and tear. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Replacing worn or burned contacts, Checking control device free for operation. h) Checking after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. Note : (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts / bolts / washers / pins etc. (ii) Major spares like contacts, shunt trip coil, relays, CTs etc if replaced, shall be measured & paid separately.
S&F in repair under voltage / trip / closing contact coil / auxiliary contact block suitable for air circuit breakers of 400 to 1600 Amps capacity complete all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
S&F in repair Arc chutes (for 415 V) suitable for air circuit breakers of 400 to 1600 Amps capacity complete all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
S&F in repair shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of 400 to 1600 Amps capacity complete all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
S&F in repair arcing contacts (fixed / moving) suitable for air circuit breakers of 400 to 1600 Amps capacity complete all as specified and directed. Make: L&T/C&S/ GE/ABB/Siemens/Schneider
M&L preparation of old painted surfaces of LT panels / Feeder pillar boxes / RMUs etc. and spray painting with one coat of synthetic enamel paint complete all as specified and directed. Note:- Rusted surfaces shall be scraped with sand paper and shall be applied with one coat of red oxide primer before application of paint and unit rate quoted against this item shall be considered to include this aspect. Make :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Preparation of old painted external surfaces of two bed Mortuary cabinet units indoor type by scraping old dusted paint by steel brush, brooming, rubbing, cleaning and making the surface smooth and including applying two coats of synthetic enamel paint complete all as specified and as directed. Note:- Rusted surfaces shall be scraped with sand paper and shall be applied with one coat of red oxide primer before application of paint and unit rate quoted against this item shall be considered to include this aspect. Make :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid along alignment of cable as protection to cable in trenches including taking out old u/s bricks complete all as specified and directed.
Taking out existing XLPE Cable of any size in underground / alongwith pole or in any positon, removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed. Note:- Excavation and earthwork (if required) shall be measured and paid seperately.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, laid in trenches / duct / on pole complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl item No. 92.00 but cross sectional area 50 Sqmm x 3.5 Core
All as per Sl item No. 92.00 but cross sectional area 95 Sqmm x 3.5 Core
All as per Sl item No. 92.00 but cross sectional area 120 Sqmm x 3.5 Core
All as per Sl item No. 92.00 but cross sectional area 185 Sqmm x 3.5 Core
Re-laying only old servicable (cable obtained from taking out old cable here-in-before after checking the fault) UG LT XLPE electric cable with alumimium conductor, 1100 volts grade of any size, laid in trenches / duct / on pole complete all as specified and directed.
Supply and topping up of transformer oil with di-electric strength not less than 60 KV into the conservator tank / body tank of the transformer / OCB / FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. Make: Apar (Power Oil) / Savita (Transol) / Asian
Filtration of transformer oil of transformers / FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
M&L for rewinding of distribution transformers (LT) of capacity 200 to 750 KVA of any make by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.
M&L for rewinding of distribution transformers (HT) of capacity 200 to 750 KVA type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.
Supply and replacement of silica gel in breather of transformers all as specified and as directed.
M&L for taking down transformer of capacity 200 to 750 KVA from existing site at any substation of INHS Kalyani under AGE EM –I, carrying to workshop safely for repair by dismantling of HT and LT cable connections, securing the cable ends properly by insulating covering material, detaching all the earthing connections , jumpers and busbars including LT busbar cable boxes and closing the transformers for loading into transporting vehicle with the help of crane, transporting it to back at original position after repair work, unloading, all cable connections, earthing connection testing and commissioning complete all as specified and as directed.
M&L for preparation of old exposed painted surfaces of indoor / outdoor type transformer of capacity 200 to 750 KVA and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth / base with white synthetic enamel paint on black synthetic enamel paint back ground complete & including one coat of white wash on exposed surface of transfomer plinth / base complete all as specified and as directed. Note :- (i) Colour of paint shall be as decided by Engr-in-Charge. (ii) Rusted surfaces shall be scraped with sand paper and shall be applied with one coat of red oxide primer before application of paint and unit rate quoted against this item shall be considered to include this aspect. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, of size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed.
Supplying and laying in repair synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
M&L for applyibg Si-COAT 570RTV Silicon High voltage insulator coating solution using sprayer to the cable chamber of 11 KV indoor VCB panel including testing complete all as specified and as directed by Engr-in-Charge.
M&L for applyibg Si-COAT 570RTV Silicon High voltage insulator coating solution using sprayer to the Bus bar chamber of 11 KV indoor VCB panel including testing complete all as specified and as directed by Engr-in-Charge.
M&L for disconnecting electrical connection of defective / burnt out UG LT cable of any size 2 to 4 core from main switch / DB / Junction boxe / LT / HT Panels, excavating, taking out the required length of existing cable from loop, cutting the defective portion of cable / old termination at end, providing new aluminium thimbles / lugs of suitable size and reconnecting the same with existing location and refilling of cable trench with existing sand and bricks Note :- (i) Unit rate quoted against this item shall be considered to include cost of necessary earth work, relaying of sand, bricks and making the surface as per existing. (ii) Additional length of cable / pipe (if required) shall be measured and paid seperately.
S&F aluminium lugs to cable end suitable for LT/HT cable of size of 16 to 70 sqmm complete all as specefied and directed.
All as per Sl item No. 111.00 above but suitable for LT/HT cable of size of 90 to 240 sqmm
M&L for taking out the loose or separated Door / canopy / front & back sheet covers from existing LT panel and refixing the same after welding, providing nut bolts / hinges if required as per site, proper locking arrangement and fixing of proper earth connection etc complete all as specefied and directed.
M&L including replacement of out door panel board canopy door, made out of 3.15 mm thick CRCA sheet, duly power coated with removable door hinges, water proof rubber beading and locking arrangement with SS aldrop & pad lock/ concealed locking arrangement, danger notice boards, mentioning panel details including gas welding for fixing the door complete all as directed. Note:-Unit rate quoted shall be considered to include locking arrangement with SS aldrop & pad lock/ concealed locking arrangement, danger notice boards, etc reqd for one LT panel. Contactor shall quote their rates accordingly.
All as per Sl item No. 114 above but made out of 2 mm thick CRCA sheet.
M&L for detecting HT / LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
S&F in repair LT bushings with gun metal rod with threading & of suitable length / size, as per existing including metal rings / bolts / washers / rubber rings and suitable for distribution transformer of capacity 200 to 500 KVA including complete all as specified and as directed.
S&F in repair HT bushings with gun metal rod with threading & of suitable length / size, as per existing including metal rings / bolts / washers / rubber rings and suitable for distribution transformer of capacity 200 to 500 KVA including complete all as specified and as directed.
S&F in repair switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts all as per clause no 19.69 of SSR part-I (2009) with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, insulator type mounted on MS channel operating rod with pad lock arrangement including dropout fuse assembly and lightning arrester complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers
M&L preparation of old HT steel 4 pole structure (11 metre height) with connected cross arms, cable protection pipes, clamps etc, and including applying one coat of aluminium paint on complete height and making 06 Nos band / strips with black and yellow synthetic enamel paint alternatively, 30 cm wide each upto 1.80 m height from top of plinth block complete all as specified and directed. Make of paint : Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
SAMPATH ENTERPRISES
SVG SUPPLIES
VENKATESWARA ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .