Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L1 | Accepted-AOC Awarded contract being lowest | |
| 2 | L2₹34.9 L+₹7.1 L (25.4%)Rejected-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-AOC Rejected Not being lowest | |
| 3 | L3₹38.5 L+₹10.7 L (38.4%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-AOC Rejected Not being lowest |
| Sl No | Description | Qty | Unit | Benchmark Engineers and Contractors L1 | Jack Electrolinks Private Limited L2 | Green Ray Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00Note : 1. Contractor should visit at site before Quoting the tender to know the working condition of the station. 2. All requisite safety measurers adopted by contractor on site. 3. The contractor shall provide and deploy two nos skilled AC technician and two nos helper (as approved by GE / Engineer-in-charge) shall report at 0900 hrs to JE E&M /Engineer-in-charge to collect the complaints job card in working days & complete the same complaint within 24 hrs. The amount for payments of AC technician & helper is included in given rates. 4. The contractor shall also provide AC technician & Helper on Sunday & holiday if required or asked by JE E/M / Engineer-in-charge. 5. The complaints shall be rectified with in 24 hrs, If the complaints is/are not attended /not completed within 24 Hrs (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil, fan motor and PCBs) recovery will be done Rs 1000.00 Per complaint per day. 6. For major Parts like replacement of compressor, cooling coil, condensing coil, fan motor and PCBs should be rectified within 05 Working days, if the contractor not rectify within time then recovery will be done Rs 1000.00 Per complaint per day. 7. After completion of Job work complaint, the contractor has to produce job card duly signed by user & JE E/M / Engineer-in-charge. 8. If contractor failed to provide their AC Technician or absent to attend the complaints then recovery will be done Rs 2000.00 Per day. | ||||||
| 2.00 | Material & labour for servicing of split type AC/Floor standing AC/Cassette AC unit of any capacity any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, washing with water indoor & outdoor coils,setting of grill alignment & knobs, Checking for any leakages & brazing ,topup of refrigerant gas as per existing, replacement of thermocoal insulations for air tightness as required, testing etc all as specified and directed.(Note diferent type of gases if filled then the amount of gas is paid seperatly on relevant items.) | 280 | Each Job | 290 ₹81,200 Lowest | 300 ₹84,000 | 599 ₹1,67,720 |
| 3.00 | Material & labour for painting the outdoor unit of split type AC/Cassette type AC/Floor standing Ac of any capacity/any make including stand by synthetic enamel spray paint as per existing colour and writing MES No all as specified and directed. | 50 | Job | 110 ₹5,500 Lowest | 400 ₹20,000 | 600 ₹30,000 |
| 4.00 | Removing the unserviceable blower motor/condenser fan motor from the Split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete. | 12 | Each job | 520 ₹6,240 Lowest | 1,500 ₹18,000 | 900 ₹10,800 |
| 5.00 | Supply and fix in replacement blower motor/condenser fan motor suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. Make: AUE/ Marathon Electric or equivalent | 12 | Each Job | 2,100 ₹25,200 | 2,500 ₹30,000 | 900 ₹10,800 Lowest |
| 6.00 | Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh or equivalent | 10 | Each Job | 13,200 ₹1,32,000 | 10,000 ₹1,00,000 Lowest | 12,000 ₹1,20,000 |
| 7.00 | All as per items No-6, here-in-before but suitable for 2 Ton split type Acs . | 10 | Each Job | 14,300 ₹1,43,000 | 12,000 ₹1,20,000 Lowest | 18,000 ₹1,80,000 |
| 8.00 | All as per items No-6, here-in-before but suitable for 3.5/4 Ton Tower A/C | 5 | Each Job | 15,400 ₹77,000 Lowest | 28,000 ₹1,40,000 | 30,000 ₹1,50,000 |
| 9.00 | Supply & fix in replacement the copper piping (suction line and discharge line) and power cable including the thermal insulation with white tape as per site requirement, as directed by Engr in charge. | 80 | RM | 630 ₹50,400 | 1,500 ₹1,20,000 | 390 ₹31,200 Lowest |
| 10.00 | Supply & fix drain pump suitable for casssette type Split AC 2 TR including taking down the defective drain pump all as specified and directed by Engr-in-charge.. | 8 | Each | 1,310 ₹10,480 | 1,000 ₹8,000 Lowest | 1,000 ₹8,000 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 May 2026, 10:30 amClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2026_MES_763629_1
GE MAINT EZHIMALA 8837
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
19 Jun 2026
6 May 2026
3 Jun 2026
6 May 2026
28 May 2026
21 May 2026
6 May 2026 - 13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Material & labour for servicing of split type AC/Floor standing AC/Cassette AC unit of any capacity any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, washing with water indoor & outdoor coils,setting of grill alignment & knobs, Checking for any leakages & brazing ,topup of refrigerant gas as per existing, replacement of thermocoal insulations for air tightness as required, testing etc all as specified and directed.(Note diferent type of gases if filled then the amount of gas is paid seperatly on relevant items.) | 280 | Each Job | - | - |
| 3 | Material & labour for painting the outdoor unit of split type AC/Cassette type AC/Floor standing Ac of any capacity/any make including stand by synthetic enamel spray paint as per existing colour and writing MES No all as specified and directed. | 50 | Job | - | - |
| 4 | Removing the unserviceable blower motor/condenser fan motor from the Split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete. | 12 | Each job | - | - |
| 5 | Supply and fix in replacement blower motor/condenser fan motor suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. Make: AUE/ Marathon Electric or equivalent | 12 | Each Job | - | - |
| 6 | Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh or equivalent | 10 | Each Job | - | - |
| 7 | All as per items No-6, here-in-before but suitable for 2 Ton split type Acs . | 10 | Each Job | - | - |
| 8 | All as per items No-6, here-in-before but suitable for 3.5/4 Ton Tower A/C | 5 | Each Job | - | - |
| 9 | Supply & fix in replacement the copper piping (suction line and discharge line) and power cable including the thermal insulation with white tape as per site requirement, as directed by Engr in charge. | 80 | RM | - | - |
| 10 | Supply & fix drain pump suitable for casssette type Split AC 2 TR including taking down the defective drain pump all as specified and directed by Engr-in-charge.. | 8 | Each | - | - |
| 11 | Supply and fix in repairs of indoor cooling coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by the Engr-in-charge. | 12 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.87 MB
Tender.pdf
Tender Documents • 0.87 MB
BOQ_855348.xls
BOQ • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .