Tender Value
Refer Docs
EMD Value
₹36.3 L
Closing Date
29 Aug 2022, 3:00 pmClosed
CHIEF CONSTRUCTION ENGINEER RND SOUTH
CCE RNDS DRDO MIN OF DEFENCE AKBAR ROAD PB NO 1569 SECUNDERABAD 500003
Provision of Civil Works for Shore Integration Facility (SIF) for Programme ICS at NPOL, Kochi
2022_DRDO_705836_1
83639/CIV/SIF-NPOL/CON
Limited
Civil Works
730 days
NPOL KOCHI
AS PER NIT
2 documents required · 2 mandatory
₹10,000
Yes
CCE RND
₹36.3 L
Yes
6 Sept 2022
9 Aug 2022
30 Aug 2022
9 Aug 2022
29 Aug 2022
19 Aug 2022
9 Aug 2022 - 17 Aug 2022
Amount
SUB HEAD-A -BUILDING INCLUDING INTERNAL SERVICES
SUB HEAD-I - EARTH WORK & ANTI-TERMITE TREATMENT
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock
Hard rock (blasting prohibited)
Credit of Excavated Hard Rock obtained from above
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
SUB HEAD-II - REINFORCEMENT AND PLAIN CEMENT CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Extra for shuttering in circular work
Edges of slabs and breaks in floors and walls
Above 20cm wide
Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve durability and workability without impairing strength; including pumping of concrete to site of laying,curing, carriage for all leads; but exclding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the following grades of concrete. Note:- Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg/cum.
All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg/cum.
Concrete of M30 grade with minimum cement content of 350 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of engineerin- charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). (Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.)
Cement concrete prepared with batch mixing machine
SUB HEAD-III - BRICK / STONE WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
SUB HEAD-IV - DOOR & WINDOW WORK
Providing and fixing rubber wall buffer for doors of size 50mm. Long including necessary screw etc. Compleat.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in charge.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
With 12 mm mild steel U beading
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of as per required size, joints mitred and welded by angle iron as per required flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer , but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile C
Fixing with adjustable lugs with split end tail to each jamb
Profile E
Fixing with adjustable lugs with split end tail to each jamb
Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows all complete with.
5.5 mm thick glass panes
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Exceeding 16.80 sqm in area
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including Patch Lock with strike plate having 3Nos high securty computer keys make ozone/Enox at Bottom and 600 mm length providing stainless steel brush finished handles of 25mm dia both side on each door and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws. (Glazing, paneling and dash fasteners to be paid for separately) :
For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber, wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately, Only weight of aluminium sections to be measured for payment).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Extra for providing etched glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Supplying & Installing of Debo Toilet cubical, Shoe Box Series Size 1100-1500 L x1200 Wx1800H with S.S, Grade 304 Hardware Debo Toilet cubical system. Made out of 12mm compact grade laminate (both side) of approved colors & design panel, door & divider panel to be fix vertically by using aluminum S.S. Finish profiles of 0.80mm thickness. The intermediate panel is one continuous panel without any joints fix to the wall & front panel by using "U" profile of Aluminum 0.80mm thick in S. S. Finish, as per the required size Max depth -1500mm, door width 600 mm )and front panel should be cut & fixed as per the require measurement. Maximum width of the front panel including door will be 1500mm.Center to center for each cubical. All pilasters are to be supported by Shoe box of 32 mm height .Top rail & wall side fixing with aluminum S.S .finish anodized profile. Each cubical should be equipped with S.S hardware consist of (a) Privacy thumb turn, (b) Door Knob, (c) Coat hook, (d) 3 Hinge (e) Corner Profile (f) "h" profile at the door vertical sides. (G)Al S.S Finish shoe box
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
SUB HEAD-V - FLOORING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing antiskid Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Makrana white second quality
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
8mm thick
Granite of any colour and shade
Providing and laying antiskid rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying double charged, mat finish vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying double charged, mat finish Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete
Size of Tile 600x600 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Acid and alkali resistant tile
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Acid and alkali resistant tile
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
40 mm wide and 4 mm thick
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Light shade pigment using white cement
SUB HEAD-VI - ROOFING WORK
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
110 mm bend
Shoe (Plain)
110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing soil, waste and vent pipes :
100 mm dia
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :
Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for New work :
100 mm diameter pipe
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
Circular shape 560 mm internal diameter
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Barge board (Upto 300 mm)
Gutter (600 mm over all girth)
Designing, fabricating, testing, protection, installing and fixing in position of MS motorised sliding Roof Covering automation with sliding gate operator teeth rack and fittings push button switch photo cell warning light transmitter and receiver and 4 core cable of approved make with all fittings of size 7 mtr x12 mtr with Structural analysis & design and preparation of shop drawings for the specified design loads conforming to revelent IS Code,leak proof and automatic 3 bhp motor operated system including remote control including all labour materials lead lift etc complete as per Arch. Drawing for the finished item of work complete etc as approved by engineer-in-charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre,
to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound ,
jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,
with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm
and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :
Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer- in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
SUB HEAD-VII - PLASTERING &FINISHING WORK
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
White washing with lime to give an even shade :
New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
French spirit polishing :
Two or more coats on new works including a coat of wood filler
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
SUB HEAD-VIII - INTERNAL WATER SUPPLY & SANITARY INSTALLATIONS WORK
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china Urinal partitions of Size 365x800mm of required color with C.I. brackets, C.P. brass chain with rubber plug, complete, including painting of fittings and brackets, cutting and making good the wall wherever required .
Providing and fixing C.P. brass Push Button urinal valve Auto Closing System with Built in control cock and wall flange of approved quality conforming to IS:8931. Mke Jaquar Modal No. PRS-CHR-077 or Eqv.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing of White vitreoous china counter top wash basin Size 565x425x140 mm of with CP brass waste assembly, rubber adapters for waste connection complete incl. CI/MS brackets duly painted, nuts, washers, cutting and making good the walls/ floors complete, as per direction of Engineer incharge. Jaquar make ( cat no. KUS-WHT-35935) or equivalent
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board
610x460 mm bowl depth 200 mm
Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and .
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm. make JAQUAR ACN-1111N or eqv.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Supply and install solid state no touch operating fully highgenic SS hand drier of best quality, to be operated with 230 volts, single phase, with fully hygienic condition, with all accessories including cutting and making good the walls, wherever required.
Providing and fixing Glass Body liquid soap dispenser with simple push lever fitted with liquied soap (One time) includidng cutting and making good the walls wherever required. (Make : Jaquar ACN-CHR1135N or equivalant)
Providing & fixing CP brass Health faucet with PVC Flexible Tube with wall hook.( JAQUAR MODEL NO-573 or Equilent.)
Providing and fixing 150mm CCT Jali with necessary fitting etc all complete. Make as approved by engineer-in-charge.
Providing & fixing 8 mm thick beveled edge looking mirror of superior glass (of approved quality) The mirror will be fixed on 3/4" dia SS finish stud, all complete as per instructions of Engineer-in-Charge
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing unplasticised Polyvinyl Chloride (UPVC) pipes, having thermal stability for hot & cold sewage supply including all UPVC plain fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, & testing of joints complete as per direction of Engineer in Charge.Toilet Sanitary pipe work
75 mm nominal inner dia Pipes
100 mm nominal inner dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
32 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
SUB HEAD-IX - INTERNAL ELECTRIFICATION WORK
The item shall be supplied as per the description of boq item including technical specifications
LIGHT POINT WRING
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , heavy class PVC conduit concealed in wall after necessary chase cutting with finishing/ surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch ).
Two Light point controlled by one 6A switch ).
Three Light point controlled by one 6A switch ).
Exhaust fan point controlled by one 6A switch including ceiling Rose.
6A SWITCH & SOCKET
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
LIGHT FIXTURES
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor or Electronics Ballast etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. with Lamp Control Gear & Fixing Accessories.
DuraLED Highbay energy efficient lighting 80W,with a choice of narrow beam and wide beam optics. Philips BY325P LED100S CW PSU GR FG WB
Philips 20W LED-Batten-BN021C LED22S PSU CW GR (4 ft)
Philips 6W Endura LED Bulkhead, WT202W LED6S CW PSU S2 PC
16W Philips LED surface Mounted Downlighter SM251C LED16S- 6500 PSU WH
8W MIRROR LIGHT Surface Mounted MAKE-PHILLIPS CAT NO. BN 021 LED12S 6500 PSU GR
18W MIRROR LIGHT Philip Cat.No. BN021C LED22S PSU CW GR
30W LED Recessed Mounted Philips CAT No.RC380B LED30S-6500 G5 L60W60 PSU OD
15W LED Philip Cat.No. DN296B LED15S-6500 PSU WH
12W LED Philip Cat.No. SM250C LED12S- 6500 PSU WH
FANS/EXHAUST FANS
Supplying & Installation of exhaust fan in the existing opening, including gravity louver, making good the damage, connection, testing, commissioning etc. as required.
300mm Double ball bearings heavy duty motor exhaust fan, Protective bird guard is provided, Power: 70 watts. Guard : 36 Spokes. Noise level 40-45 dB
600mm 900 RPM Heavy Duty wall mounted Fan, Metal Body, 500W, 240V
Supplying, fixing, testing and commissioning of High Flo Wave Wall Mounted Fan 400MM suitable for Single Phase 240V AC supply complete with all accessories.make , Havells .Model - Turboforce
Supplying, fixing, testing and commissioning of cieling Fan, 1200MM suitable for Single Phase 240V AC supply complete with all accessories.make , Havells .Usha,Bajaj
POWER POINT WRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32A, 430 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32 A "C" curve, 4 P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A, 430 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 A "C" curve, 4 P, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 10 sq. mm earth wire
DISTRITUTION BOARD
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 16 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Boxes (IP 43) suitable for following tripple pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.
For 4 way, Double door TPN MCBDB
For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
CABLE TRAYS
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
SUB HEAD-B - FURNITURE WORK
Supply and placing of officers table size shall be 1500 Width mm x 750 Depth mm x 750 Height mm . The table top shall be made of pre- laminated particle board with 18 mm thick and 15 mm thick understructure covered with PVC lipping .There shall be locking provided for top drawers only , attractive black colour handles for all drawers plus only one colour is available beech. It shall have one drawer (RHS ) & HDU attachment on one side & 3 drawer unit on the other side ( LHS of user ) of make GODREJ (ENZO TABLE 5026) / WIPRO / FEATHERLITE.
Supply and placing of High Back Chair: SEAT ASSEMBLY: The seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressed plywood , upholstered with fabric upholstery covers and moulded Polyurethane foam. SEAT SIZE: 47.0 cm. (W) x 48.0 cm. (D) BACK ASSEMBLY: The back asembly. should be made of powder coated (OFT 40-60 microns) tubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back should be upholstered using double layer spacer mesh fabric with high tenacity yarn. BACK SIZE : 46.5 cm (W) x 70.5 cm (H) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression.
ARMRESTS: The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. CENTRE-TILT mechanism: The mechashould be m should be designed with the following features: • 360° revolving type. • 17° ±2° maximum tilt on pivot at centre • Upright position locking. Tilt tension adjustment. . PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 11.0 ±0.3cm. TELESCOPIC BELLOW ASSY: The bellow should be 3 piece telescopic type and injection moulded in Black Polypropylene.
PEDESTAL ASSEMBLY: The pedestal should be injection moulded in black 33% glass-filled Nylon66 and fitted with 5 nos. twin wheel castors. The pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors.) TWIN WHEEL CASTORS: The twin wheel castors should be injection moulded in black nylon Overall Dimensions of Chair Seat Height - min 43.3 to max 54.3cm. Height - min 99.5 to max 110.5cm. Width & Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm. of make GODREJ (OXBO HIGH BACK)/WIPRO/FEATHERLITE.
Supply and placing of Visitors chairs : SEAT ASSEMBLY: The seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressed plywood , upholstered with fabric upholstery covers and moulded Polyurethane foam. SEAT SIZE: 47.0 cm. (W) x 48.0 cm. (D) BACK ASSEMBLY: The back asembly. should be made of powder coated (OFT 40-60 microns) tubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back should be upholstered using double layer spacer mesh fabric with high tenacity yarn. BACK SIZE : 46.5 cm. (W) x 60.5cm. (H)
HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression. ARMRESTS: The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. . TUBULAR FRAME: The powder coated (DFT 40-60.microns) tubular frame should be cantilever type & made of Ø2.54 ±0.03cm. x 0.2 ±0.016cm thick M.S.E.R.W. Tube. Overall Dimensions of Chair Seat Height - 46.5cm. Height - 93.5cm. Width & Depth of Chair as measured from pedestal - Width-61.0 cm and Depth-64.5 cm. of make GODREJ (OXBO VISITOR) / WIPRO / FEATHERLITE.
Supply and placing of Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1981mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options shall be available of Model storwel plain of Godrej or equivalent.
Supplying and placing in position of Sofa set 3 seater of size Dimensions W x H x D (cm) 183 x 86.4 x 83.1 with Fabric of model Facet of Godrej or equivalent. as approved by Engineer-in-charge
Supplying and placing in position of Sofa set 1 seater of size Dimensions W x H x D (cm) 101.1 x 86.4 x 83.1 with Fabric of model Facet of Godrej or equivalent. as approved by Engineer-in-charge
Supply and placing of UPS battery steel rackof size 4 x 1.75 x 6 feet (length x Width x height) as approved by Engineer-in-charge
SUB HEAD-C - AIR CONDITIONING
The item shall be supplied as per the description of boq item including technical specifications
HIGH SIDE VRV/VRF SYSTEM :
outdoor units
Supply, Installation, Testing and Commissioning of following capacities of Vairable Refrigerant Flow (VRF / VRV) Outdoor condensing unit comprising of Invertor SCROLL compressor's, Heat Exchanger, propeller / axial fans, refrigerant Circuit, Safety Devices & Oil Recovery System, operating on R410a refrigerant gas. Necessary Refrigerant Gas and oil charge. Compressor shall be equipped with inverter controller of Insulated Gate Bipolar Transistor (IGBT) type to be efficient & quiet. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation and indoor unit individual control.
Heat Exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. Refrigerant Circuit shall include an accumulator, liquid and gas shutoff valves and a solenoid valves. The Outdoor unit shall include the following safety devices : High pressure switch, Low pressure switch, Fan motor safety thermostat, Inverter overload protector, Over Current relay, Fusible plugs, Fuses etc . Unit shall be equipped with an oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be prewired in factory for necessary power and control wiring. Aluminum sins shall be covered by anticorrosive resin film. All outdoors units shall be mounted on civil platform with necessary vibration isolators ,covered with PVC conductivity etc. Complete clamping and saddling of cabling work and refrigerant piping .
Nominal Cooling Capacity at ARI conditions including refrigerant as required.
40 HP OUT DOOR UNIT
CEILING SUSPENDED 4 WAY CASSETTE TYPE AC INDOOR UNITS:
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
SPLIT AC SYSTEM
Supply, installation, testing and commissioning of Hi wall Air Cooled split unit 3 STAR Rating as described in specifications. The unit shall be complete with cabinet type fan coil unit complete with hermatically inverted compressor ,evaprotive coil ,fans etc and external condensing unit complete in all respects, , , MS Stand, valves and inulation. It shall be inclusive of cooling thermostat with wiring, first fill of refrigerent, adjustable outdoor frame, control and earthing. The unit capacities shall be after taking deration into account due to copper piping lengths:
2.0 TR Hi wall type split air conditioning units
1.5 TR Hi wall type split air conditioning units
Supply, installation, testing and commissioning of AC SINGLE PHASE 5KVA Automatic operation having input voltage 170v to 270v and output voltage 240v. Complete with voltmeter, high and low voltage cut off & time Delay relay type digital voltmeter Stabilizer.as complete as required.
Supply , installation , testing and commissioning of refrigerent copper piping as per thr standered for 2.0 TR/1.5TR Hi wall type split air conditioning units including 3Cx2.5 sqmm power cable or as required , insulationed with closed cell nitrile /EPDM as per thr standered.The external refrigerent piping with cable will run on cable tray .including cutting,chasing etc complete in all respect.
2.0/1.5 TR Hi wall type split air conditioning units
Supply .Fixing and testing of PVC condensate drain piping with insulation of 6 mm thick nitrile rebber including wall cutting ,chasing of wall etc complete in all respect of fallowing pipe dia.
25mm dia.
CENTRAL CONTROLLER
Supply, Installation, Testing and Commissioning of CENTRALISED Remote Controller advanced I Touch Manager type.
REFRIGERANT PIPING
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Refrigerant Piping Joints:
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Suction Line as required.
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Liquid Line as required.
DRAIN PIPING
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
40 mm dia
32 mm dia
25 mm dia
CONTROL & TRANSMISSION WIRING
Supply, installation, testing & commisioning of control om transmission wiring of 2 core 1.5 sqmm copper wire in suitable PVC conduits between indoor & out dor unit & outdoor units to central remotes controllers
WEATHER PROOF ISOLATOR
Supply, installation, testing and commisioning of weather proof box with 40/63 Amp MCCBs 25KA of suitable rating near the outdoor units for isolations with all complete.
POWER CABLE
Providing and fixing of PVC armoured copper FRLS cabes from panel boards to the uníts through walls/ceing Wtn appropriate clamps and fixing arrangements and end termination etc. as per specifications and drawings
4 Core - 25 Sqm
4 Core - 16 Sqm
4 Core 2.5 Sqm
Cable Tray-
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 2 mm thickness with cover
ELECTRICAL CONTROL PANEL: Out Door Type
Outgoings-
6Nos. 63 Amps 4 Pole RCCB/ELCB 16KA For Out Door Unit with ON/OFF Indication.
35 Nos. 10 Amps DP MCB 16KA
30 Nos.16 Amps DP MCB 16KA
Supply, Erection , commissioning of Maintenance free earth station consisting of 40mm Dia 3m long copper electrode capsule field with earth enhancing compound sealed at both ends and brazed Lead for connection at one end, Suitable for direct installation at side with brass bolt at the top end, with nuts & Washers including Mesonary enclosure, CI Cover with frame and interconnection along with earth pit Identification board and as required spreading of earth enhancing chemical compound etc.Complet the Scope Also includes Excavation in all type of soil, back filling and makinng the area neat & etc. complete
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SUBHEAD -D- LIGHTING PROTECTION SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Supply and installation of vertical air termination with 40mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper rod including PCC block and all fixing accessories.
Supply GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Supply and laying of following size earth strips the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth necessary interconnections with earth station and equipments.
50 x 6 mm GI Strip laid in Ground
Supply and laying of following size earth strips with all fixing accessories when laid on the parapet & terrace with necessary interconnections with earth station and equipments.
25X5mm GI Earth strip conductor with DMC Insulated Supports
SUB HEAD -E- EARTHING SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub-main wiring/ cable as required.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
40 mm Stone gravel to be laid in the transformer yard for a height of 100mm
SUB HEAD -F-TELEPHONE AND DATA SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
1 or 2 Module (75mmX75mm)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Providing, fixing connecting and testing of under noted size of solderless telephone tag block Connector in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
10 Pair Tag Block
40 Pair Tag Block
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet (RJ11)
Supplying and fixing of modular type Lan (RJ-45) outlet in existing Box complete as required.
Computer socket outlet (RJ 45)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required
1 run of cable
Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
180 mm X 100 mm X 60 mm deep
SUB HEAD -G-FIRE ALARM SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Supply, Erection, Testing and Commissioning of Two loop addressable fire alarm control panel IP55 with built in loop cards. FACP shall have capacity to look upto minimum of 198 devices per loop i.e.99 detectors & 99 modules, further shall be designed with 25% spare capacity towards future expansion FACP shall have 2 x 40 character LCD alphanumeric display with backlight, fully (100%) programmable disablement. Test, sounder fault, delayed mode, relays disabled, earth fault, system/CPU fault, sounder disabled. Alarm silenced, supply fault, power etc. It shall be provided with required capacity of maintainable free sealed acid batteries to provide 48 hours ( Including 30 mins in alarm condition) of indications with a maximum of 200 software zones.FACP Loop shall have built- in networking feature i.e. to form networking on LAN using TCP/IP converter Interface. It shall also have built -in feature of automatic telephone dialer(4 telephone/mobile nos.) with facility to pass pre- recorded message of up to 20 sec. System shall be designed as per the technical specification and shall comply to EN 54/IS 2189/UL Standards. etc as complete required.
Supply, installation, testing and commissioning of Microprocessor based manual call point complete as per specification required.
Supply, Installation, Testing & Commissioning of Microprocessor based Wall Mounted Voice Evacuation Hooter cum Speaker of 2W having power taps at 1/4-1/2 complete as per specification required.
Supply, installation, testing and commissioning of Microprocessor based addressable control module for activating the hooter etc. complete as per specification required.
Supplying, installation, testing and commissioning of Dual LED Response indicator for indicating the activation of the Remotely located Detector. Complete in all respect.
Supply, Installation, Testing & Commissioning of Smoke detector complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling complete as per specification required.
Supply, Installation, Testing & Commissioning of Heat detector complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling complete as per specification required.
ADDRESSABLE BEAM DETECTOR
Supplying, laying, testing and commissioning of point wiring for sensors and devices like Input/Output modules, MCP's, smoke & heat detectors etc. with 2 x 1.5 sq.mm FRLS PVC insulated multi-stranded single core copper conductor wire in M.S. conduit with conduit accessories including loop circuit from main fire alarm panel located at ground floor in fire control room complete as required.
Supplying, laying, testing and commissioning of 2RX2CX1.5 sq.mm copper armoured cable for Fire alarm panel.
SUB HEAD-H- FIRE FIGHTING SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC,synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
1620 lpm at 56 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS :325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 56 m Head
supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
1620 lpm at 56 m Head
Supplying and fixing air vessel made of 450 mm dia, 8mm thick MS sheet, 2000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wetriser/ sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
80mm dia
150mm dia
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supplying, installation, testing and commissioning of electric driven monoblock pump suitable for automatic operation and consisting of following, complete in all respects, as required : .Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure,It will be suitable to lift domestic water from UG ti over head tank @ head 56 mter, horizontal foot mounted type with Suitable Class' insulation, conforming to IS :325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.(1W+1S)
Providing and fixing following dia, 750 mm long hot dipped G.I. Puddle flanges for water tanks as per I.S. 1239 (Class C) with 6mm thick M.S. Plate of suitable size and welded all-round the pipe fixed in walls, beams and top slab of R.C.C tanks, etc. complete all as per the directions and to the satisfaction of Engineer-in-charge.
150 mm dia (Flanged ends MS plate 6 mm thick; 250 mm x 200 mm plus dia of pipe).
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal / Stainless Steel cap and chain as required
Single headed Gunmetal
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Gun metal
Supply and fixing of Fire Hose Box of Stainless Steel of size 3 ‘x 2' x I' 6” to accommodate two numbers of 30 M length hoses and branch pipe, glass fronted, double door with lock painted fire red outside with suitable structural support complete but excluding civil works.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
100 mm dia
150 mm dia (wall thickness 6.3 mm)
200 mm dia (wall thickness 6.3 mm)
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Supply, laying, testing and commissioning of centrifugally Cast Ductile Iron pipes conforming to IS 8329:2000 class K9, with Cement Mortar Lining (CML) inside as per IS 455:2989 along with Bituminous coating outside suitable for socket and spigot type (DISS) joints for following sizes and testing the joints for leakage (if any) and making good hydrant system with all required accessories etc complete.
100 mm dia
150 mm dia
200 mm dia
Supply, fixing, testing and commissioning of centrifugally Cast Ductile Iron fittings/Specials (Socket and Spigot type) conforming to IS 9523: 2000, Class K9, with Cement Mortar Lining (CML) as per IS 455: 1989 inside and bituminous coated outside ISI marked such as Bends, Elbows, Tees, Flanged Spigots, Collars, flanges (flange rating PN 16) etc testing the joints for leakage (if any) and making good hydrant system.
Note : DI Specials mentioned below are to be procured as per actual site conditions and as required only. Full payment will be released only for the specials fixed and erected at the site of work, as directed by the Engineer-in-Charge.
All Socketed Tee
150 mm x 150 mm x 150 mm dia
Double Socketed Tee with Flanged Branch
150 mm x 150 mm x 100 mm dia
All Socketed 90deg bend
100 mm dia
All Socketed 45deg bend
100 mm dia
All socketed 22.5deg. bend
100 mm dia
All socketed 11.25deg. bend
100 mm dia
Reducer socket
100 mm x80 mm
Socketed collar
100 mm dia
Flanged Socket
100 mm dia
Flanged Spigot
100 mm dia
Fabrication,Supply,testing and commissioning coupler of DI to MS of 100mm dia / or directed by engineer incharge with all required accessories etc. complete
Fabrication,Supply,testing and commissioning coupler of MS to DI of 100mm dia / or directed by engineer incharge with all required accessories etc. complete
Supply and fixing in position of neoprene Rubber push-on-joints for the Di pipes of following sizes.
150 mm dia
Supply, erection, testing and commissioning of pressure switches for fire fighting pumping system.
Supply, erection, testing and commissioning of pressure Gauges with range of 0-15 bar along with isolation cock and pipe at hydrant station for fire fighting pumping system.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal /Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
100mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100mm dia
150mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
100mm dia
Providing, fixing, testing & commissioning of installation Butterfly valve of PN1,6 with bronze / gunmetal seat duly ISI markedcomplete with nuts,bolts,washers,gaskets confirming ti IS 13095 of following sizes as required
100 mm dia
80 mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 Meter
FIRE CONTROL PANELS
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
4way-100 mm dia M.S. Pipe
Providing anti corrosive Wrapping and coating with 4 mm thick bitumastic membrane (Pypkote) for MS pipe laid below ground including all materials with minimum overlapping of 30 mm.
Supply, erection, testing and commissioning of GM gate valves (PN-16) with threaded ends and conforming to IS 778 and of following sizes:
SUB HEAD-I- EOT Crane
The item shall be supplied as per the description of boq item including technical specifications
Supply, installation, testing and commissioning of 10 Ton Capacity EOT cranes and VVVF drives complete with three speeds for hoist, CT and LT as per IS 3177/2148 ambient Temperature 40 deg C. including crane rails, festoon type current collection system complete with support tracks, cable loops, cable point to crane festoons with all necessary fixtures down shop lead low voltage pendant control with safety stops, inter locks power isolater etc., complete.
Double Girder Box Type. 25% overload ,height- 12 mtr,Span 14.5mtr heavy Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation,Suitable Spped, 415V AC Supply, IS- 807/3177/4137, 110v AC Control Supply , Floor operated via pendant push button, Span to be measured by the Bidder at site and it shall be his sole responsibility to provide span suitable.Design,Drawings and list of material to be submitted to department duly proof checked by Govt.agency/reputed technical institute as approved by department.VVVF drive controls with along travel and cross travel movement and with pendent control operation as per IS:807/IS:3177(including Festoon cables,50 square bar rail,third party inspection,transportation,Design proof check.
MOTORS- Conforming to IS 325-1978& 900-1965,
GEAR BOX- Electro Hydraulic Thrusters type, 3Ph, 440V, A.C. Conforming with IS 3938 - 1983
WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963)
Rope Drum- made from Seamless/ms rolled
Hook- Forged Material EN-3A
WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976.
BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972
COUPLING- AlI Couplings will be Geared Coupling
SHAFT- All Shafts will be of EN - 9
RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 )
LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983
PANEL BOXES - All panel boxes will be of steel febricated
CONTROL TRANSFORMER- 750 VA, 44OV / LLOV.
POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays' BCH time delay Relay
PAINT- Two coats of Red Primer & Two coats of Golden Yellow.
Full platform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil)
SUBHEAD-J-WATER COOLER
The item shall be supplied as per the description of boq item including technical specifications
Supplying, installation, testing and commissioning of water cooler Electric driven (single phase), Having storage Capacity of 80 litres and nominal cooling capacity of 40 Litres per hour. Make: Bluestar/ Usha /Voltas and RO Water Purifier of 25 litres /hr capacity RO+UV+UF with TDS Controller .Make- kent/Urekafobes or eqvl.
SUB HEAD-K-UPS SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 16 KA,TPMCCB
UPS WIRING
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , heavy class PVC conduit concealed in wall after necessary chase cutting with finishing/ surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch ).
Two Light point controlled by one 6A switch ).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
CIRCUIT/ SUBMAIN WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 10 sq. mm earth wire
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
For 4 way, Double door TPN MCBDB
For 6 way, Double door TPN MCBDB
For 8 way, Double door TPN MCBDB
SUB HEAD-L-CCTV & ACESS CONTROL
The item shall be supplied as per the description of boq item including technical specifications
Supply, installation, testing and commissioning of UL Listed 3 MP Dome Camera , ONVIF profile S & G ,UL , CE , FCC Certified , 1/2.8" CMOS sensor ,2.8mm to 12 mm motorized varifocal , Min Illumination :0.05 Lux @ (F1.2,AGC ON), 0 lux with IR ,120 dB WDR, Shutter Speed : 1/5 ̴ 1/100,000 s, Video Compression : H.265 , H.264 ,frame rate 30 fps @ 3MP ,Edge analytics : line crossing , perimeter intrusion ,Face detection , cross counting , stationary object , Inbuilt IR LED , IR distance upto 30 mtrs ,IK 10 Vandal proof ,IP 66 , POE .. specifications..
Supply, installation, testing and commissioning of UL Listed 3 MP Bullet Camera , ONVIF profile S & G ,UL , CE , FCC Certified ,1/2.8” Progressive Scan CMOS ,2.8 mm to 12 mm motorized varifocal lens ,min illumination : 0.05 Lux @ (F1.2,AGC ON), 0 Lux with IR , Auto switch IR cut filter ,SD card support ,1 input / 1 output audio support ,Shutter Speed : 1/5 ̴ 1/100,000 s , 120 dB WDR , Video Compression : H.265 ,H.264 , frame rate : 30fps @ 3MP ,Edge analytics : line crossing , perimeter intrusion ,Face detection , cross counting , stationary object , In built IR LED , IR Distance upto 40 meters , IP 66 , POE. as per technical specifications
Supply, installation, testing and commissioning of 3 MP PTZ Camera , ONVIF profile S , G and Q , UL,CE,FCC Certified , 30 X Optical Zoom , Focal length 4.3mm to 129 mm , 12 X digital zoom , Quad stream ,H.265 video compression support , frame rate 25 FPS @ 3MP , 50 FPS @ 2 MP ,2 streams simultanepusly at 1920 X 1080 p ,Shutter Speed : 1/1 ~ 1/10000 sec , 360° endless Pan , -20° ~ 200° tilt , Pan Manual Speed : 0.1° ~ 300°/s , Tilt Manual Speed :0.1° ~ 200°/s , 256 presets , 120 dB WDR ,Edge analytics : Abandoned Object, Intrusion Detection, Tampering, Wrong Direction, Loitering Detection, Object Counting, Stopped Vehicle, Object Removal , Inbuilt IR LED , IR Distance upto 150 mtrs , IP 66. with USB / Networked PTZ Keyboard
Supply , Installation , Testing and Comissioning of NVR Server for VMS , operating system : Embedded Linux / Windows 2012 R2 Server , with min camera support of 40 cameras , 16GB RAM or better , 8 x SATA HDD Slots with total max storage capacity of 48TB(8*6 ) with 30 days recording , Quad Gigabit Ethernet Interfaces , Dual redundant PSU
Supply, installation, testing and commissioing of Layer 3 managed switch with 24 ports (RJ-45) , as to support all cameras and having 20% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, rack mountable, SMPS power supply & other accessories complete as per specifications and as required.
Supply, Installation, Testing & Commissioning of 24 Port POE+ Layer 2 Switch with 2 SFP Port
Supply , Installation , Testing and Comissioning of Server for VMS , Dual Processor: 2 x Intel Xeon E5-2620 v4 2.1GHz or better , 16GB RAM , Cooling fans , 8 X SATA HDD Slots , Storage :48TB (8 x 6TB 7.2K RPM SATA Enterprise Grade 6Gbps 3.5in Hot-plug Hard Drive) ,Embedded Linux / Windows 2012 R2 Server ,Quad Gigabit Ethernet Interfaces , Hardware Raid Controller to support Raid 0,1,5,6 or more ,Preinstalled VMS. Licenses required to activate Camera Channels ,Dual Redundant PSU ,DVD+/-RW Drive ,Rack Mount .
Supply, Installation, Testing & Commissioning of 6TB HD
Supply, Installation , testing and commissioning of 12 V SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage.
Supply, Installation, Testing and Commissioning of Full HD 55" LED Professional Display Panel with 350 nits brightness,3 HDMI ,USB,VGA.
Supply , Installation , Testing and commissioning of CAT 6 UTP cable 23 AWG solid copper conductors.
Supply , Installation , Testing and commissioning of CAT 6 information outlet for CCTV
Supply , Installation , Testing and commissioning of CAT 6 jack panel
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); Memory: 4GB, NON-ECC, 1600MHZ; RAM: 4GB (1x4GB) Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit.
Supply and laying of 25mm dia, heavy duty FRLS PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required.
Supply, installation, testing and commisioning of 19" rack 32 U floor mount rack with all standard aceessories that include cable manager, fan, power bar with sockets etc. as per requirement
Supply, installation, testing and commisioning of 19" rack 9 U wall mount rack with all standard aceessories that include cable manager, fan, power bar with sockets etc. as per requirement
Supply , Installation , Testing and commissioning of CAT6 patch cord 3 feet for rack side switch termination
Supply, installation, testing and commisioning of 16 watts ceiling/wall speakercomplete with all accessaries as per specification
ACCESS CONTROL SYSTEM
Supply ,installation,testing & commissioning of Microprocessor based door controller of following configuration suitable for controlling smart card readers complete with 100-hours memory backup, power supply with battery backup & computer connectivity with all accessories.
TCP-/ IP based 4 reader door controller with intercontroller connectivity with inbuilt power supply, 2hrs. Battery pack. The controller shall be supplied & installed in a separate enclosure having lock & key facility.
The controllers shall be installed above the grid ceilings.
Supply ,installation,testing & commissioning of Proximity Card Readers without HID
Supply ,installation,testing & commissioning of Bioclass Fingerscan with Card Readers
Supply ,installation,testing & commissioning of Proximity Cards IP based
Supply ,installation,testing & commissioning of Double door Electro Magnetic Lock + Door Position Sensor of Suitable Capacity .
Supply ,installation,testing & commissioning of Single door Electro Magnetic Lock + Door Position Sensor of Suitable Capacity .
Supply ,installation,testing & commissioning of Magnetic contacts / Reed switches.
Supply ,installation,testing & commissioning of Buzzer
Supply ,installation,testing & commissioning of Breakglass units for Labs / Server Rooms.
Supply ,installation,testing & commissioning of PC station consisting of computer with 21" LCD / TFT colour monitor, printer, modem, keyboard, mouse and operating software.
Supply ,installation,testing & commissioning of BIS Control, Attendance, Management Software & shall be prgrammed with anti bypass system for access control. Software integration to be done between CCTV system & Access control system to get details on Intrusion attempts.
Supply ,installation,testing & commissioning of Egress Switch.
Supply laying,testing & commissioning of 8C 14/38 SWG Shielded copper cable from controller to reader / panic bar
Supply ,laying,testing & commissioning of 2C 14/38 SWG Shielded copper cable
Supply laying,testing & commissioning of 20 mm MS Conduit with all wall mounting accessories & JB's as required
SUBHEAD -M- LIFT SYSTEM
The item shall be supplied as per the description of boq item including technical specifications
Supply, erection, testing and commissioning of electic passenger lift of 544 Kgs. capacity to serve Ground to 3d floors ( total Four stops & four opening ) with a total travelling length of approximately 15.0 mtrs. including elevator, VVVF drive, machines, controllers, car body, car guides, landing doors, counterweights, main suspension steel rope, cabling, safety device, three side glass panel and governer, automatic sliding doors for car and landing hoist way with full height IR sensor, buffers for car and accessories including intermediate supporting channels/ brackets for car guides with all allied works and scaffolding etc. and supply, erection, testing and commissioning of automatic rescue device (ARD) system operating on 4x12 V - 24 AH dry maintenance free batteries with 10 second actuation time and automatic switch over facility including all neccessary cables and termination etc. complete.
Supply, erection, testing and commissioning of electic Goods lift of 2 ton . capacity to serve Ground to 3rd floors ( total Four stops & four opening ) with a total travelling length of approximately 15.0 mtrs. including elevator, VVVF drive, machines, controllers, car body, car guides, landing doors, counterweights, main suspension steel rope, cabling, safety device, three side panel and governer, automatic sliding doors for car and landing hoist way with full height IR sensor, buffers for car and accessories including intermediate supporting channels/ brackets for car guides with all allied works and scaffolding etc. and supply, erection, testing and commissioning of automatic rescue device (ARD) system operating on 4x12 V - 24 AH dry maintenance free batteries with 10 second actuation time and automatic switch over facility including all neccessary cables and termination etc. complete.
SUB HEAD-N- ROAD AND DRAINS WORK
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
All kinds of soil
Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m :
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Supplying and stacking at site.
Good earth
Moorum
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler,cleaning and preparing the existing road surface as per specifications :
On W.B.M. @ 0.75 Kg / sqm
Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete.
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater andwith profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately).
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with :
Moorum
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
SUB HEAD-O- EXTERNAL WATER SUPPLY WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered).
Depth exceeding 1.5 m but not exceeding 3 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Extra for shuttering in circular work
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve durability and workability without impairing strength; including pumping of concrete to site of laying,curing, carriage for all leads; but exclding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the following grades of concrete. Note:- Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M30 grade with minimum cement content of 350 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External work
50 mm dia nominal bore
80 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
50 to 80 mm nominal bore
Supply and fixing water supply route marker with route indication on 150 mm. dia. Cast iron disk bolted in 40x40x3mm. angle iron grouted in 1:3:6 concrete block 150x150x300mm. deep including two coarse of aluminum paint on metal work.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
50 mm nominal bore
80 mm nominal bore
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :
Serrated with central bulb (225 mm wide, 8-11 mm thick)
Waterproofing of HorizontalSurface
Horizontal Areas (Below Raft): Supplying and installing Dr.Fixit Prebond - 1.2mm thick self-adhesive HDPE membrane having the following technical properties-Puncture resistance 1000 N (as per ASTM E 154) ,Tensile strength of 25 Mpa as per ASTM D412,Elonagtion of >500% as per ASTM D 412, Resistance to hydrostatic head > 60M as per ASTM D 5385,Peel adhesion to concrete 880N/m as per ASTMD903. The system should be fully bonded to the RCC and consists of highly resilient HDPE layer, a pressure sensitive adhesive layer which is covered by a weather proof protective layer. The membrane shall have minimum of 100 mm side and end laps which shall be sealed with double sided adhesive tape. The size of the membrane should not be less than 2.4Mtr. x 20 Mtr. to minimize the joints and the entire waterproofing treatment should be guaranteed by the principal manufacturer as a system, for ten years, materials, labours, tools, tackles, etc., complete.
Waterproofing of Vertical Surface
Vertical Surface (Retaining wall): Providing and laying of 1.5 mm thick Dr.Fixit Samshield XL- SBS based self-adhesive waterproofing membrane topped with hdpe cross laminated Valeron film with the following technical properties-Elongation of >200 % as per ASTM D882, puncture resistance of >200 N as per ASTM E154 including cleaning the surface,priming the surface with cold applied bituminous primer@4-6 sqmtr/litre, properly sealing the joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the slab etc. complete.
Providing & Fixing of protection board 8MM – HDPE Dimple board spot bonded on retaining wall before backfilling.
Providing aluminum flashing, wherever required for termination of Dr. Fixit Samshield XL 1500 membrane at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height as specified in drawings for termination of the membrane and finally sealing the strip using Dr. Fixit Pidiseal , Polysulphide sealant.Providing aluminum flashing, wherever required for termination of Dr. Fixit Samshield XL 1500 membrane at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height as specified in drawings for termination of the membrane and finally sealing the strip using Dr. Fixit Pidiseal , Polysulphide sealant.
Providing and applying Dr. Fixit Fastflex, a two component polymer based cementitious waterproofing system in following sequence;
Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means.
Removal of all surface imperfections, protrusions,loose concrete & filling of cracks using Dr Fixit Pidicrete URP Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement.
Providing & grouting at construction joints cementitious grout into each nozzles( 1 mtr c/c) at regular intervals as per the requirements.
Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of DR. FIXIT URP by weight of cement.
Applying 3 coats of Dr. Fixit Fastflex(2 component, prepacked,polymer modified cementitious coating)@ 3kg/sq.mtr all over the slab including the angular fillets and extendable over the vertical walls .Finally sprinkling sand over the third coat for better adhesion with plaster. The interval between each coat of Fastflex application is 6-8 hrs.
Providing & laying a protection layer of 25 mm thick cement mortar admixed with Dr. Fixit Pidiproof LW+
SUB HEAD- P- External Electrical Work
The item shall be supplied as per the description of boq item including technical specifications
H.T.VCB PANEL: ( Near Transformer in Weather Proof Enclosure Outdoor type)
Supply, installation, testing and commissioning of 800A, 3P, 11 KV outdoor type IP 55, drawout, Vacuum circuit breaker single Panel board fabricated out of minimum 2 mm thick CRCA sheet as per specification. The panel shall be complete with all accessories & cable termination boxes for incoming 3C x 185 Sqmm XLPE and outgoing 3C x 185 Sqmm XLPE, 11 KV cable. All current carrying parts should be of Copper.
The panel shall be comprising of 1 no, 11 KV, 800 A,3P, drawout type vacuum circuit breaker with spring charged stored energy mechanism having spring charging motor 240VAC, Closing coil suitable for 24V DC, Tripping coil suitable for 24V DC, Aux. Contacts 6NO+6NC, Antipumping device, Mechanical Close & Trip Lever, Manual spring charging device, mechanical operation counter, mechanical ON/OFF, Mechanical spring charged indication
One (1) no. multi function meter with RS 485 port with minimum parameters Voltage, Ampere, KWH, KVAh, KW, KVA, KVAR, PF & HZ. with 1 Set (3 Nos) of 50/5A ratio,CL 1.0 C.T,s & control fuses.
1 Set of phase indication lamps with HRC fuses (Red, Yellow and Blue).
1 Set of indication lights with HRC fuses for CB open, CB close, Auto trip, Spring charged, battery low`.
Auxillary switch/ relay, under voltage, master trip, Anti-pumping relay and other control relays etc. as per requirement -Lot. 1 Set of IDMTL O/C and E/F relay similar to CDG-61 of M/s ALSTOM or equivalent complete with 3 nos. (1 set). Current transformer 50/5A, CL-5P 10 for protection, 15 VA burden.
1 Set of potential transformer 11KV/1.732, 110/1.732 volts 100 VA burden.
1 set of 6 window, Audio / visual annunciation system complete with Transformer trouble & protection trip annunciation.
Supply, installation, testing and commssioning of above specified 11KV HT Panel as described above Board as per manufacturers instruction, as per specification and complete as required.
TRANSFORMER : Supply, installation, testing and commissioning of 11 KV/ 433V, 3 phase, 50 Hz delta/star-11 connected, out door type, 1600 KVA transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, Off Load tap changer with + 5 % to – 7.5 % tappings in the steps of 2.5%, bi-directional roller, diagrams & rating plate, Oil gauge, Oil temperature indicator, & Winding temperature indicator, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T. cable box & disconnecting chamber/ LT cable box & disconnecting chamber, (All instrument/relay/CT terminals / contacts wiring to be done upto marshalling Box). etc. complete as per specification
All relays, contacts & CT terminals to be wired upto marshalling box.
Enclosure shall be of split up type so that top portion of the enclosure can be removed without disturbing core-coil assembly for shifting purpose.
1600 KVA Transformer
Transformer described as above.
DG SET
Supply at site, installation, testing & commissioning of 3-phase, 415 volt, 50 HZ, Silent type Diesel generator set of 250 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure with canopy, inbuilt Suitable Standard tank capacity ,with AMF Panel,battery, battery charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator, pcc based auto start & synchronization set, safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722.
AMF PANEL:
Supply ,installation, testing and commissing of 415 Volt, 3 Phase, 4 wire , 50 Hz , IP-56, Free Standing Floor mounted out Door AMF Panel , made out of 2mm thick CRCA sheet for main frame and 1.6 mm thick for partions after seven tank process and painting with Epoxy powder coating. including all switchgear as detailed below. this panel shall consist of suitable rating TPN aluminium bus bar ( at the rating of 0.8/sqmm) supported with DMC/ SMC barriers and colour coded with Heat Shrinkable Sleeves. The metering shall be provided as specified. This Panel shall have short circuit with standing capacity of minimum 50 KA and consist of the switchgear as mentioned below. this panel shall be mounted on channels including supply of the same.This panel shall be got fabricated from manufactures CPRI test certificate only. this panel shall have at least two spare cubicles of maximum ratings. The size of all panel mounting meters shall be as per Suitable Design. MCCB should be rotary handle (Suitable Extended type panel for future provision as described by engineer incharge).
The pael shall include 630 amp power contactors,relays complete as required
EXHAUST SYSTEM:
Supply, erection, testing & commissioning of exhaust piping of following sizes with thermally insulated by 75mm thick layer of glass wool lagging with chicken mesh and 26SWG aluminium sheet wrapping over the exhaust pipes complete as required.
200 mm dia
FUEL OIL DAY TANK
Supply, fabrication, installation, testing & commissioning of MS day oil tank fabricated out of min. 3 mm thick M.S. sheet installed on steel frame or masonry pedestal with all associated accessories, filters valves and fittings including level controller and indicator complete as per specification as required. The tank shall be suitably treated with anticorrosive treatment in side and outside surface.
690 Liters capacity
OIL HAND PUMP
Supply, installation of hand barrel pump to pump the HSD fuel from barrels to the day oil tank with flexible hose pipe etc.
Steel Support Structure :
Supply, fabrication and installation of exhaust pipng / silencer support structure as per site requirement comprising of ISMCs, ISAs, flats rods, turnbuckles etc. The rate shall include painting with 2 primer coats of red oxide and two finishing coats of approved enameled paint.
Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English)
Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local Electricity Authorities written in English and Local languages.
11000V (250mm X 200mm)
440V (150mm X 100mm)
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11KV grade conforming to IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom.
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.
HT CABLE
Supplying, testing,commissioning of following sizes XLPE, 11 KV earthed cable in existing open structure/ Hume pipe including in vertical formation as per technical specification and complete as required. (The payments of cable length shall only be made upto gland in panel on both sides not for loop and connection cables of approximate length upto 2 metres either sides.)
3Cx240 Sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of 3CX240sq mm 11 kv,HT cable through HDPE pipe with HDD process,route marker etc compelet as required.
Supplying and making outdoor cable end termination with cast resin compound, including lugs and other jointing materials complete with all accessories for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3Cx240 Sq.mm.
Supplying and making Indoor cable end termination with cast resin compound, including lugs and other jointing materials complete with all accessories for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3Cx240 Sq.mm.
Supplying and making Streight through cable end termination with cast resin compound, including lugs and other jointing materials complete with all accessories for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3Cx240 Sq.mm.
MAIN LT PANEL
LT Panel
Transformer Incomer : 3200 A FP EDO ACB, 50KA MP RELEASE O/L,S/C, E/F PROTECTION
Metering For Incomers :
LED Phase indication lamps with individuals MCBs and control with toggle switches
Interlocking : Electrical mechanical interlocking between 2 No. Incomers
Busbars : 3000A TPN Aluminium Busbar - 1 Set
Suitable Metering For O/G
Outgoings :
MCCB 630A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 04NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 400A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 04NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 250A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 02NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 125A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 03NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
MCCB 63/40A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 10NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK
10/16A, TPN MCB - 5NOS
400KVAR APFC PANEL
Busbars : 800A TPN Aluminium Busbar - 1 Set
Outgoings :
Suitable Metering For O/G
50KVAR CAPACITOR : 4NOS, MCCB 125A TP 25KA TM RELEASE, ROTRY HANDLE FOR MCCB, 50KAVR CAPACITOR DUTY CONTACTOR, 50KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON, LAMP
25KVAR CAPACITOR : 4NOS, MCCB 63A TP 25KA TM RELEASE, ROTRY HANDLE FOR MCCB, 25KAVR CAPACITOR DUTY CONTACTOR, 25KAVR HEAVY DUTY CAPACITOR,440V,START/STOP PUSH BUTTON, LAMP
20KVAR CAPACITOR : 3NOS, MCCB 50A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 20KAVR CAPACITOR DUTY CONTACTOR, 20KAVR HEAVY DUTY CAPACITOR,440V,START/STOP PUSH BUTTON, LAMP
10KVAR CAPACITOR : 2NOS MCCB 32A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 10KAVR CAPACITOR DUTY CONTACTOR, 10KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON,LAMP
5KVAR CAPACITOR : 2NOS MCCB 16A TP 25KA TM RELEASE,ROTRY HANDLE FOR MCCB, 5KAVR CAPACITOR DUTY CONTACTOR, 5KAVR HEAVY DUTY CAPACITOR,440V, START/STOP PUSH BUTTON,LAMP
Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit. However, louvers are allowed to facilitate extra cooling.
FEEDER PANEL
Incomer : MCCB 630A FP 36KA TM RELEASE O/L,S/C PROTECTION
Metering For Incomers :
LED Phase indication lamps with individuals MCBs and control with toggle switches
Busbars : 700A TPN Aluminium Busbar - 1 Set
Outgoings :
MCCB 100 A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- MCCB 63A TP+NL 36KA TM RELEASE WITH O/L,-3 NOS S/C PROTECTION
MCCB 32A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- MCCB 32A TP+NL 36KA TM RELEASE WITH O/L,-4 NOS S/C PROTECTION
SUPPLY AND INSTALATION, CABLES
Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.
3.5 x 400 sq.mm
3.5 x 300 sq.mm
3.5 x 185sq.mm
3.5 x 150sq.mm
3.5 x 120sq.mm
3.5 x 50 sq.mm
3.5 x 35 sq.mm
4 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 x 400 sq.mm
3.5 x 300 sq.mm
3.5 x 185 sq.mm
3.5 x 150 sq.mm
3.5 x 120 sq.mm
3.5 x 50 sq.mm
3.5 x 35 sq.mm
4 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150mm dia
250mm dia
BUS TRUNKING
Supplying, installing on wall, Floor or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. Bus trunking shall be partialy indoor & outdoor type supply with metal clad enclosure having IP-56 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
3200 A Isc = 50kA for 1 second
AREA LIGHTING
Supplying of sewaged type welded steel tubular pole 7.5M height and suitable curved single arms of 1.5m x48.4mm x 3.2m(Length x OD x Thickness) with overall length of section -Bottom section- 4.5m x114.4mm x 5.4mm, Middle section- 1.5m x 88.9mm x 4.85mm, Top section- 1.5m x 76.1 x 3.25mm with IS 2713-80 , latest amedment 410-SP-6 complete M.S.BASE PLATE :- 300 X 300 X 6MM
Supply and fixing of 70W LED energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07, ENDURACITYLINERNEOSL70WLED757PASYBOTG
Erection and shiftting as required of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 8.0 meter and upto 10.0 meter
Providing and making MS steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20 mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted)
(SHEET MOULDED COMPOUND) junction box size 200mm x 140mm x95mm as per IS: 13410 & IS:14722 completed with door, hinger and locking arrangement ,including one no. 6 amps MCB SP, AL busbar (TPN) , stainless steel terminal, MCB channel , with clamp for fixing with pole.
Providing spiral coil earthing with 8 SWG G.I wire including spreading os salt and charcoal as per IS: 3043-87 with lastest ammendments.
Providing and fixing 8 SWG dia G.I. Wire on surfaces or in recess for loop earthing along with existing surfaces /recessed conduit/submain wiring/cable as requried
Wiring for street Light fitting from junction box to street light fitting with ( 2x 2.5 sqmm copper conductor, 11kv grade, PVC insulaed, unsheathed single core cable in surface/ recessed as required.
SUB HEAD-Q - SEWAGE DISPOSAL WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve durability and workability without impairing strength; including pumping of concrete to site of laying,curing, carriage for all leads; but exclding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the following grades of concrete. Note:- Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg/cum.
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand)
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100 mm diameter
150 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
300 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. / RCC pipes including bed concrete as per standard design :
100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150 x 100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of cass designation 7.5
Extra for depth for manholes
Size 120x90 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
Circular shape 560 mm internal diameter
Providing and laying hume pipe septic tank (dia 900mm.,length 2500mm.) of capacity 25 users complete as per standard design.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.w. dran pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.PS. (non modular) bricks of class designation 7 .5
SUB HEAD-R-ARBORICULTURE/ LANDSCAPING WORK
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5km lead complete (sludge measured in stacks will be reduced by 8% for payment).
In rows 5 cm apart in both directions
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%),flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed,within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m dia and 1.2 m deep
Holes 0.90 m dia and 0.90m deep
Holes 60 cm dia, and 60 cm deep
Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.
Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) and as per direction of officer in charge.
Trees for 300 no/ (4-8 & 5-6 year Slow & Fast growing group)
Complete maintenance of shrubs (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
Trees Plant
Shrubs Plant
Hedge Plant /Ground cover
Providing and displaying of Areca Palm plant, having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge.
Supply and stacking of Bauhinia blakeana (Kachnar) plant of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Cassia siamea plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus panda of height 30-45 cm. with 3-4 branches and healthy foliage in p.bag of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Thevetia nerifolia of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
Rds Project ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid