Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹44.0 L+₹20,486 (0.47%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹46.9 L+₹3.1 L (7.10%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹47.3 L+₹3.5 L (8.09%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹47.7 L+₹4.0 L (9.04%)Rejected-Finance EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | L5 | Rejected-Finance L5 |
Tender Value
₹44.4 L
EMD Value
₹88,800
Closing Date
4 Jul 2020, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
SPECIAL REPAIR TO ASSEMBLY HALL ANTE ROOM AND DINING HALL BANQUET HALL OF OFFICERS MESS AT HQ SAC TRIVANDRUM
2020_MES_343651_2
CWE(AF)/TVM/82299
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
As per NIT
7 documents required · 7 mandatory
₹500
GE AF Trivandrum
₹88,800
Yes
16 Jul 2020
9 Jun 2020
6 Jul 2020
9 Jun 2020
4 Jul 2020
16 Jun 2020
9 Jun 2020 - 13 Jun 2020
Amount
SCHEDULE 'A'
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Dismantling Stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc.complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces as backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and directed by Engr in charge
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr in charge .
M&L for 25mm thick PCC type B-0, 1:2:4 using 12.5mm graded stone aggregate as in floors complete all as specified and directed by Engr in charge .
Excavation over areas n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed by Engr in charge ..
Removing excavated material exc. 500m but not exc 1.50Km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of gauge of broken stone or boulders n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr in charge .
M&L for 100mm thick PCC Type D2, 1:4:8 using 40mm graded stone aggregate as in floors complete all as specified and directed by Engr in charge .
M&L for 100mm thick PCC Type B2, 1:2:4 using 40mm graded stone aggregate as in floors complete all as specified and directed by Engineer-in-Charge.
Dismantling of aluminium door, window. ventilator frames (without taking off shutters from the frame) including glass and all fittings & fixtures complete all as specified and directed by Engr in charge .
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:6 complete all as specified and directed by Engr in charge
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr in charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr in charge.
S&F for rolled mild steel work of Fe 410W (Grade E-250) quality 'A' as Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engr in charge .
M&L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed by Engr in charge ..
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed by Engineer-in-Charge.
M&L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 including raking cutting and waste to hips,valley etc complete all as specified and directed by Engr in charge ..
M&L for preparation of new mangalore pattern tiles and applying two coats of acrylic weather coat paint over a coat of primer complete all as specified and directed by Engr in charge .
Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed by Engineer-in-Charge.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class hard-wood, clean sawn as in scantlings complete all as specified and directed by Engr in charge .
M&L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape complete all as specified and directed by Engineer-in-Charge.
M&L for 3mm thick wall care putty on ceiling complete all as specified and directed by Engr in charge ..
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
M&L for designed cornices made out of POP to the design/size as approved by GE fixed to location in room complete all as specified and directed by Engr in charge ..
M&L for preparation of new surface of POP ceiling and applying two coats of sky graphic paint of any pattern as approved by GE over a coat of alkali resistance priming paint complete all as specified and directed by Engr in charge .
M&L for preparation of new surface of POP ceiling and applying two coats of golden mettalic colour paint of any pattern as approved by GE over a coat of alkali resistance priming paint complete all as specified and directed by Engr in charge .
M&L for complete removal of existing treatement and applying two coats of emulsion paint over a coat of alkali resistance priming paint complete all as specified and directed by Engr in charge .
M&L for 3mm thick wall care putty on wall complete all as specified and directed by Engr in charge .
Cutting openings, through brick walls built in cement mortar or cement lime mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed by Engineer-in-Charge.
S&F 18/19mm thick veneered particle boards exterior grade, solid core, general purposes type, with faced with decorative veneer on both faces fixed with screws to timber frame work fixed in pelmet boxes or in narrow width n exc 15cm each, rebated or flat edged complete all as specified and directed by Engineer-in-Charge.
M&L for PCC Type D2, 1:4:8 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatement and applying two coats of weather coat emulsion paint over a coat of alkali resistance priming paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of weather coat emulsion paint over a coat of alkali resistance priming paint complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed by Engineer-in-Charge.
M & L 1st class Hard Wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded champhered put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge.
M& French polishing on surfaces of any description , width of girth including cleaning and prepairing the surface including a coat of wooden filler on new works with two or more coats complete all as specified and directed by Engineer-in-Charge..
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
M&L for laterate stone wall cladding of size 300 X 180 x 16/18 mm including polishing etc of any pattern as approved by GE complete all as specified and directed by Engineer-in-Charge..
M&L for 1st class hardwood 38/ 40mm thick and 150mm in width wooden flooring fixed to appropriate wooden grid fixed with nails and adhesive as approved by GE including two coats of french polish over sealant and a coat of primer complete all as specified and directed by Engineer-in-Charge..
M & L 12 mm thick toughened glass with etching as required shape and size and fixed to wooden frame with all arrangements as approved by GE complete all as specifed and directed by Engineer-in-Charge..
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specifed and directed by Engineer-in-Charge..
M&L for point wiring complete with 1.5 Sqmm 1100 V grade single core FRLS PVC insulated unsheathed cable with multi stranded copper conductor ISI marked drawn through concealed PVC conduit medium grade ISI marked of suitable size on walls/ceilings etc and including provn of 1.5 Sqmm PVC insulated copper cable as earth continuity conductor fabricated branded modular suitable plate with cover with suitable screws for housing switch socket outlets, fan regulators etc all as specified and directed . Note:- Rate for cutting of chases for fixing of PVC conduits and its accessories including making good the disturbed surfaces of walls/ floors etc with the existing deemed to be included in the item rate
All as per Item No.53 above but for One switch socket outlet 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No 53 here-in- before but with 2.5 Sqmm PVC insulated FRLS multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular switch 1 way 6A 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular socket 6A 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular switch 1way 16 A 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular socket 6A /16A 2/3 pin combined 2module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular white cover plate with frame 3 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular white cover plate with frame 4module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular white cover plate with frame 6 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush Box 3 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush Box 4 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush Box 6 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement modular fan regulator,120 watt - 2 module complete all as specified and directed by Engineer-in-Charge.
Supply & Fix metal plug and socket single phase two pin and earth plug with MCB, SP 20 Amps and steel enclosure complete all as specified and directed by Engineer-in-Charge.
Taking down of old U/S old any size light fitting & supply and fix new energy efficent LED batten recess mounted downlighter of 24 Watt 5700K size 175 mm dia round height 92mm with presure die cast aluminium heat sink diffuser in white powder coated finish with intergated driver all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as specified and directed by Engineer-in-Charge. Make: Havells cat aprt No INTEGRANEODLR24WLED 857S or equivalent model of Wipro / Bajaj
M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLSgrade with copper conductor confirming to IS 694 drawn in conduit including provision of 25 mm dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed. Note: Three runs of cable and and one run of conduit shall be measured as one unit
Disconnecting and taking down the unserviceable earthing and M & L for Earthing complete with GI earth plate 600mmx600mmx6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate to a depth not less than 1.5m below ground level, connected to and including GI wire 4mm dia with GI protection pipe 15mm dia medium grade connected upto DBs by means of bolts, nuts, check nuts and washers made of copper, galvanized iron pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I.
S & F in replacement Sheet Metal Enclosure for MAIN DBs, Triple Pole & Neutral, 4 Way , 415 Volts with 100 Amps rated neutral bus bar double door vertical type, grouting the DB and making good the disturbed surfaces with extra cement without any additional cost suitable for TP/SP outgoing to accomodate and including MCCB 63A 16 KA as incoming all as directed.
Taking down unserviceable MCB distribution board, S & F SPN 8 way of any size and capacity double door with suitable busbar including disconnecting from mains and making good the disturbed surfaces all as directed.
Supply and fix only the MCB SP 6-32A ,230V,50Hz,AC with rupturing capacity 10kA all as specified and as directed.
Supply and fix only the MCB SPN 6-32A ,230V,50Hz,AC with rupturing capacity 10kA all as specified and as directed.
Removing of exsiting split type AC 1.5 ton/ 2 Ton capacity after pumping down gas from postion, refixing to postion, refixing alongwith new copper pipes of required size & fix in new postion topping up of gas in compressor after rectifing leak and refixing all as specified and as directed.
Removing of exsiting Celing fan 1200mm sweep after painting from postion, refixing to postion, refixing alongwithrequired accessories in new postion all as specified and as directed.
S&F Celing rose 3 pole PVC /poly carbonate isolated body all as specified and directed
supply and fix new energy efficent LED HUE light strip base 2 m with driver, indoor application suitable for cove lighting, decorative lighting etc with controls all prewired connection with twin core flexible PVC 0.5 Sqmm complete all as directed.
supply and fix new energy efficent LED HUE light strip base 1 m with driver, indoor application suitable foe cove- lighting, decorative lighting etc with controls all prewired connection with twin core flexible PVC 0.5 Sqmm complete all as directed.
S&F bridge for connectivity for LED HUE LED strip for indoor application including driver, LED suitable for operation in single phase 230volts AC supply system all as specified and dierced
Total of Schedule 'A'
Archana Transport
Dhanyaconstructions
AKASH CONSTRUCTIONS
Powertech Engineers
ROTECH ENGINEERS AND BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .