Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹61.2 L+₹9.2 L (17.7%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder. | |
| 3 | Rejected-Technical VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | - | Rejected-Technical Not Admitted | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Admitted | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Admitted |
Tender Value
₹53 L
EMD Value
₹1.1 L
Closing Date
29 Jan 2024, 6:00 pmClosed
COMMANDER WORKS ENGINEER
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
REPAIR/ REPLACEMENT/ MAINT OF EXTERNAL ELECTRIC SYSTEM INCLUDING SERVICE CONNECTIONS, REPLACEMENT OF LT POLES, LT PANELS, EARTHINGS AND MISC WORK UNDER GE BARRACKPORE
2024_MES_635352_1
CWE/BKP/32 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BARRACKPORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE BARRACKPORE
₹1.1 L
Yes
29 Feb 2024
2 Jan 2024
31 Jan 2024
2 Jan 2024
29 Jan 2024
15 Jan 2024
Amount
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the Engineer-In-Charge.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide in exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 3mtr in depth and getting out complete all as specified and as directed by the Engineer-In-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by the Engineer-In-Charge.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the Engineer-In-Charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation.
Supplying and laying common burnt bricks, clay building, sub class 'B' desingation 75 in trenches for cable protection complete all as directed.
Relaying of old serviceable bricks any size any type in trenches for cable protection complete all as directed.
Material & labour for GI pipe 80 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
Material & labour for GI pipe 40 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
Taking down old UNSV post top fittings, M & L for new generation LED post top lantern, 30/35Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories all as specified complete all as specified and directed. (Make- Havells/CG/Bajaj/Philips)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including GI Strip of size 25x4mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (GI strip upto 7.5m including testing consider in this item).
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling for poles complete all as specified and directed by Engr in charge.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge.
M & L for preparation of old painted surface of steel tubuler pole of 9 mtr long swaged pole by removing all dirt, dust, corrosion etc and apply two coat of synthetic emulsion paint upto 1.2 mtr hight in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on pole including writing of identification Nos, etc complete all as specified and as directed for following pole.
Taking out old/Unsv damaged existing steel/concrete poles of any size/length from existing position including necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and as directed.
M & L for supply, erection and commissioning of steel tubular swaged poles simple/decorative type complete with cast iron base plate, finial taper plug, bolts, nuts and screwes as specified type LT type 410 SP-31, (9m long) including two coat of synthetic emulsion paint upto 1.2 mtr hight in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on pole with excavation, earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation and coping of poles with PCC 1:2:4 type C1 (using 20mm graded stone aggregate)and complete all as directed by Engineer-in-Charge. (Note :- Excavation, earth work and concrete work complete not included in unit item of the rate quoted by the Contractor and the same will be paid seperately).
Laying only cable of any size with proper Excavation,Returning Filling,Removing,Sand Cushioning,bricks of specified size all as specified and directed. Note: 1.Excavation ,Returning Filling,Removing,Sand cushioning,Bricks will be measured and paid separately. 2.item will be issued under schedule B item.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 3.0 mtr both sides of overhead line with in a gap of span upto 50 mtrs each depositing the same for cleaning the site all as directed by the Engr-in-Charge.
S&F in repairs MCCB 25 to 100 Amps 3 pole, 415 V, breaking capacity 16 KA,100% ICU including spreader terminals & connected accessories complete all as specified and directed.
S&F in repairs MCCB 125 Amps 3 pole, 415 V, breaking capacity 16 KA,100% ICU including spreader terminals & connected accessories complete all as specified and directed.
S&F in repairs MCCB 100Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25/36 KA, 100 % ICU including spreader terminals & connected accessories complete as specified and as directed.
S&F in repairs MCCB 160 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100 % ICU including spreader terminals & connected accessories complete as specified and as directed.
S&F in repairs MCCB 200 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA,100 % ICU including spreader terminals & connected accessories complete as specified & directed.
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100 % ICU including spreader terminals & connected accessories complete as specified & directed.
Material and labour for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removal of the soil outside of the installation complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watts 230 Volt, AC, Outdoor type with high pressure die cast aluminium housing and heat resistant and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete including taking down old UNSV light fitting from swaged/PCC pole of maximum 9 metre height from the normal ground level all as specified and directed.
Supply, fabricated and and fixing of street light bracket/single arm street light bracket as per site required made out of GI pipe 1.0/1.2 Mtr long, 32 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Boaring holes horizontally under Road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 100 mm dia for passing of UG cable all as specified and as directed.(GI Pipe laid shall be measured seperately)
M & L for load distribution of LT panels/feederpillar box and building panel for transformer phase balance, including insulation tap lugs etc if required for load distribution all as specifed and completed by engr-in-charge.
Supply and lay LT UG Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core including taking down old cable complete all as directed by Engr-in-charge.
Supply and lay LT UG Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16sqmm 2 core including taking down old cable complete all as directed by Engr-in-charge.
Supply and lay LT UG Cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core including taking down old cable complete all as directed by Engr-in-charge.
Supply and lay LT UG Cable PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35x3.5 sqmm including taking down old cable complete all as directed by Engr-in-charge.
Supply and lay LT UG Cable PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 x3.5 sqmm including taking down old cable complete all as directed by Engr-in-charge.
Supply and lay LT UG Cable PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 x3.5 sqmm including taking down old cable complete all as directed by Engr-in-charge.
M&L for preparation for old rusted steel surface of feeder pillar box/LT panel of any size ,applying one coat of synthetic enamel paint as per the existing pattern above the PCC and black paint on legs of feeder pillar/LT panel and cutting vegetation growth all around and on the feeder pillar box/panel board upto 1 mtr radius complete all as specified and directed.
Repairs to LT panel out door/indoor type including taking out old damaged / unserviceable door,door hinges and welding new hinges of size as per existing and providing one locking arrangement all as directed.
M & L Air termination, single pointed aluminium rod 12mm dia and 300mm long including taking down old unserviceable complete all as specified and directed.
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down old unserviceable complete all as specified and directed.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down old unserviceable complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4MM galvanised iron strip all as specified and directed.including taking down old unserviceable complete all as specified and directed.
Supply and fixing CRCA kiosks box/pole junction box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one No MCB 10 Amps, SP having size 250x250x160 mm complete including making fixing arrangement with 9 mtr long swaged pole wiht flat iron clamp all as specified and directed by Engr-in-charge.
Supply and fixing in repair danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for 25x20 cm size all as directed
Supply and fix cable jointing kit on existing underground laid cable for 1.1 KV grade cable for straight through joint Tubular sleeve version, complete with jointing material and accessories suitable for XLPE, armoured, aluminium conductor cable size 10-16 Sqmm 2 Core. Make- Mseal/Raychem/Denson Note- (i) Rate quoted is deemed to be included for Cable jointing with existing serviceable UG cable laid under trench and providing new UG cable of approprite size upto LT feeder pillar box and necessary testing. (ii) New cable of any size from straight throught joint to feeder pillar box will be measured and paid seperately under relevant items of schedule)
All as per item No 47.00 above but cable size 10-16 Sqmm 3.5/4 Core
All as per item No 47.00 above but Cable size 25-50 Sqmm 3.5/4 Core
Supply, installing, testing and commissioning LT Outdoor floor mounted BUS BAR BOX , powder coated, factory made and tested , (SIZE-750MMX500MMX450MM) platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class (IP-43) in accordance with IS-2147. b) and made of 3.00 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5 mm thick and 450 mm long), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of the BUS BAR CHAMBER:- (a) 400 Amp TPN, Alu. conductor,Supported on insulated plate form,interconnection of all incomings & outgoings . (iii) RYB Phase indicating light LED type- 01 Set.
Supply, installing, testing and commissioning wall mounted Indoor type electrical meter box, powder coated, factory made and tested , (SIZE-900MMX1050MMX300MM) , suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system internally connected with 6 Sqmm copper from MCCB outgoings to MCBs of any rating. The panel shall be dust and vermin proof, protection class (IP-43) in accordance with IS-2147 and made of 1.60 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 25x6 mm thick MS Iron clamp), front opening type with hinged,single door with locking arrangement. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of taking down existing serviceable KWH meter of any rating qty-06 Nos and refixing in new meter box complete and removal of old system of KWH meter fixing arrangement and MCB DB of SPN/TPN type any size complete and Panel having the following:- (a) Bus bar chamber - Aluminium 100 amps, 415V, RYBN internally connected with 16 Sqmm Copper wires from MCCB. (b) RYB Phase indicating light LED type- 01 Set. (c) INCOMING/Main power supply controlling:- (i) MCCB 4 pole ,415 V, of rating 63 Amp 10 KA- 1 No. (d) Outgoing = 07 Nos MCB SPN of 32 Amps rating .(NOTE- Electrical accessories like MCCB & MCBs any rating will be measured and paid seperately under relevant items ) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 6 Sqmm flexible.
Supply, installing, testing and commissioning wall mounted indoor type electrical meter box, powder coated, factory made and tested , (SIZE-750x750x300MM) , suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system internally connected with 6 Sqmm copper from MCCB outgoings to MCBs of any rating. The panel shall be dust and vermin proof, protection class (IP-43) in accordance with IS-2147 and made of 1.60 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 25x6 mm thick MS Iron clamp), front opening type with hinged,single door with locking arrangement. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade. The scope of work also comprising of taking down existing serviceable KWH meter of any rating qty-04 Nos and refixing in new meter box complete and removal of old system of KWH meter fixing arrangement and MCB DB of SPN/TPN type any size complete and Panel having the following::- (a) Bus bar chamber - Aluminium 100 amps, 415V, RYBN internally connected with 16 Sqmm Copper wires from MCCB. (b) RYB Phase indicating light LED type- 01 Set. (c) INCOMING/Main power supply controlling:- (i) MCCB 4 pole ,415 V, of rating 63 Amp 10 KA- 1 No. (d) Outgoing = 5 Nos MCB SPN of 32 Amps rating (NOTE- Electrical accessories like MCCB & MCBs any rating will be measured and paid seperately under relevant items )
M & L for complete servicing, Calliberation and testing of 11 KV Vacuum Circuit Breakeer (VCB) as per the following scope of the work :- (a) Complete servicing to be carried out as per the manufacturer guidelines. (b) Removal of corroded grease and foreign particles from various parts of the VCB. (c) Cleaning of all parts with cleaning agents such (d) Checking the setting/alignment of pole assembly and contact impression. (e) Checking the arching contacts gap and same to be adjusted or replaced with new contacts if any. (f) Checking the release setting as UVR/Shunt trip/Earth fault protection release. (g) Checking the tightness of all hardwares if any and also presence of hardware and provide the same if not available. (h) Checking operating mechanism and trip mechanism function. (j) Re-greasing and lubrication of complete VCB. (k) Testing of protection release with necessary testing kit. (l) Re-fixing the VCB and service report to be issued.
Supply and fixing of Vacum Intermpter including taking down of old unserviceable one complete all as specified and as directed.. Make : As per existing Existing sample
Supply and fixing motor for SP charging with gear including taking down of old unserviceable one complete all as specified and as directed.. Make : As per existing Existing sample
Supply and fixing spout bushing including taking down of old unserviceable one complete all as specified and as directed.. Make : As per existing Existing sample
Supply and fixing of Power Pack 110 VAC/ 110 VDC taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supply and fixing of trip and close coil 110 VDC or as per existing volts rating including taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supply and fixing isolating contacts with brass ring including taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supply and fixing close trip system shaft mechanism including taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supplyand fixing of T.N.C. Switch taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supply and fixing of CTs for VCB of Existing size (set of three)including taking down of old unserviceable one complete all as specified and as directed. Make : As per existing Existing sample
Supply and fixing of Indicator lamp, LED type of colour red, blue and yellow taking down of old unserviceable one complete all as specified and directed
Supply & fixing in repair lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amp of rating 11 KV taking down of old unserviceable one complete all as specified and as directed.
Material, Labour & equipment for de-hydration and filtration of transformer oil to improve the di-electric strength (not less than 54KV) including recording results complete all as specified and as directed.
Supply and fix moulded case circuit breaker FP 440 volts 50 c/s 350 amps breaking capacity 36 KA 100% icu including supply and fixing 4 pole spreading terminal and taking down of old unserviceable one all as specified and as directed
Supply and fix moulded case circuit breaker FP 440 volts 50 c/s 250 amps breaking capacity 36 KA 100% icu including supply and fixing 4 pole spreading terminal and taking down of old unserviceable one all as specified and as directed
Supply and fix moulded case circuit breaker FP 440 volts 50 c/s 400 amps any type as per site requirement breaking capacity 36 KA 100% icu including supply and fixing 4 pole spreading terminal taking down of old unserviceable one all as specified and as directed
Disconnecting the HT & LT connections and taking down of existing Indoor/Outdoor/canopy type transformer of any capacity mounted on 2/4 pole structure/plinth/substation and transport to factory from site/Power House/ AGE E/M yard for repair and back to site/Power House/ AGE E/M yard after necessary repair/replacement of defective parts including installation in the same location and testing after proper connection, complete, all as specified and directed by Engr-in-Charge. Note: (a) The rate quoted for the item includes the following :- (i) Arrangement of manpower, tools , plants , crane and recovery vehicle for transportation and shifting of transformer to work shop and back. (ii) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (Transformer oil will be measured and paid seperately). (iii) Re-winding of defective winding of transformer, if required will be carried out under this item . (Winding material shall be measured and paid separately under respective items) . (b) Re-winding of transformer and replacement of defective part will be carried out only after inspection of Engineer in Charge. ( Rewinding of Transformer will be paid separately) (C) Any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
Material and labour for rewinding of HV/LV side of copper wound transformer with winding wire as per relevant IS, copper winding wire as per IS : 1180 and and using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer including taking down of old unserviceable copper winding wire complete all as specified and as directed .
Repair/maintenance and servicing of step down transformer 11 KV/433 Volt of capacity upto 630 KVA , comprising following work services :- (a) Disconnection carefully of cable end termination of HT & LT side. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (c) Draining out transformer oil and keeping aside in barrel for re-use and then again pouring back after necessary filteration and dehydration including top up with new transformer oil to make up the reduced quantity if required (New Transformer oil for topping up will be measured and paid separately). (d) Replacement of top and buttom Gaskets. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Cleaning of bush and stud both HT/LT side and refixing the same with new cock sheet as required (h) Reconnection of all cable terminals HV & LV sides and refixing the top cover after replacement of gaskets, conservator tank in position. (j) Cleaning and heating of silica gel in breather and replacing with new silica gel if required.. (k) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead. Note: (i) Filteration and dehydration of transformer oil, New transformer oil, (ii) Spares like bushes and studs,New silica gel,New buchholz relay and M seal monoplast, etc required for replacement shall be measured and paid separately. The labour element involved in replacing the spares shall be deemed to include in the unit rate quoted. (iii) The unit rate quoted shall include the cost of all other minor spares as required not mentioned hereinafter.
Supply and Fix bushing and stud complete with porcelain insulators for LT side (as per existing size/Model) for transformer of capacity upto 500 KVA.
Supply and fix bushing and stud complete with porcelain insulator for HT side (as per existng size/Model) for transformer of capacity upto 500 KVA
Supply only transformer oil ISI marked in sealed containers for transformers oil, confirming to IS-335 with dielectric strength of not less than 54 KV at 2.5 mm gap and testing for strength including recording results complete all as specified. Note:- (i) Purchase vouchers alongwith manufacturer's test certificate shall be produced to GE. (ii) Nos of sealed containers shall be recorded in MB.
Supply and fixing silica gel for breather as per existing specification in sealed bag for transformer up to 650 KVA capacity complete all as specified and directed.
M & L for preparation of old painted steel or iron surfaces of transformer of any capacity by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer capacity 100KVA to 630KVA with black synthetic enamel thick paint in white back ground complete all as specified and directed.
Supply & fixing gang operated air breaker switch ,triple pole, mechanically operated , mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 amps, out door type (confirming to IS specifications) HT 11 Kv , triple pole with fixed contacts of phosphorous and bronze Fuse carrier fitting , 9 insulator type mounted on MS channel operating rod with pad lock arrangement including dismantling old unserviceable gang operated Air breaker switch from two pole / four pole structure complete all as specified and as directed. Note: Rates quoted deemed to be inclusive of all equipment such as crane & transported vehicle .(Set of three)
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole,cable laying etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the Engineer-In-Charge
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide in exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 3mtr in depth and getting out complete all as specified and as directed by the Engineer-In-Charge
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by the Engineer-In-Charge
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the Engineer-In-Charge
M&L for sand cushioning in trenches for protection of Ht/LT under ground cable including watering and consolidation.
Supplying and laying common burnt bricks, clay building, sub class 'B' desingation 75 in trenches for cable protection complete all as directed.
Supplying and laying reinforced precast concrete cable cover , class HV,type 1 with peak of size 450mmX230mmX50mm in trenches for cable protection complete all as directed.
Relaying of old bricks any size any type as obtained from excavation for cable all as per specified and directed.
Supply and fix galvanised iron pipe in 50 mm bore, light grade for protection of UG cable laid in trenches / fixed to pole with MS clamp,nut, bolt etc complete with all fitting such as socket or any other item required for fixing of pipe including taking down old unserviceable one complete all as directed. (Note :- MS clamp, nut,bolt etc required for fixing the pipe with pole shall be deemed to be included in the quoted rate).
Material & labour for GI pipe 80 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
Material & labour for GI pipe 100 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and includingGI Strip of size 32x6mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (GI strip upto 7.5m including testing consider in this item).
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling for poles complete all as specified and directed by Engr in charge.
Material and labour for providing cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in coping for poles complete all as specified and directed by Engr in charge.
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 2.0 metres from the over head line to nearby trees, complete all as specified and as directed. Note:- Only effected Length of over head conductor (length of only one conductor for the effected area)
Material and labour for emergency maintenance work for HT/LT supply system during breakdown by deploying skilled labour and electricians at faulty site including transportation and other tools and plant required at site for fault rectification. Note:- Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. In case the contractor or his rep shall not come to the site of breakdown and start attending breakdown within two hours, a penalty of Rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues.
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge.
M& L XLPE insulated, LT armoured electric cable with aluminium stranded conductor of 1100 volts grade, cross-sectional area 70sqmm, 3.5/4 core laid in trenches / pipes / ducts / wall / borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down/up of existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation / earth work, sand cushioning, cable cover / brick shall be measured and paid separately if required)
M& L XLPE insulated, LT armoured electric cable with aluminium stranded conductor of 1100 volts grade, cross-sectional area 95sqmm, 3.5/4 core laid in trenches / pipes / ducts / wall / borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down/up of existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation / earth work, sand cushioning, cable cover / brick shall be measured and paid separately if required)
M& L XLPE insulated, LT armoured electric cable with aluminium stranded conductor of 1100 volts grade, cross-sectional area 120sqmm, 3.5/4 core laid in trenches / pipes / ducts / wall / borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking down/up of existing cable of any type and any size complete all as specified and directed .(NOTE: Excavation / earth work, sand cushioning, cable cover / brick shall be measured and paid separately if required)
Material and labour for preparation of old rusted steel surfaces of HT swaged poles (of 11m length) and applying one coat of synthetic enamel paint up to 1.2 meter height as per the existing pattern above the P.C.C coping and one coat of aluminium paint beyond 1.2 meter height (for the rest portion) including cross arms, brackets and re-writing pole numbers and cutting vegetation growth all around and on the poles up to 1 metre radius complete all as specified and directed
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (hevy duty) with aluminium conductor 11000 volts grade (Earthed) of size 95 sqmm 3 core (Make Havells/ Gloster/Finolex/KEI), complete all as specified and directed. Note:- Excavatioin and earth work, sand cushioning, protection covers, protection pipes and jointing kits Iincluding jointing materials shall be measured and paid for separately.
S & F Steel Tubular Poles complete with and including cast iron base plate, finial taper plug, bolts , nuts & screws, type 410 SP-55(11 Metre long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, complete in all respect as specified and as directed, Note:- Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately.
M&L for finding fault in the existing route of the HT Cable by cable fault locator & submission of the report complete all as specified and directed.
Supply and fixing HT cable route maker fabricated with Cast Iron with 6-7 mm thick round sheet on top of 150 mm complete with MS flat/Angle (size 25x25x5mm) iron leg of 600 mm long complete erect with PCC 1:2:4 complete all as specified and directed.
M & L for Trenchless Technology Boring by emplyoing Horizontal Directional Drilling/Boring machine (HDD Machine) for drilling under ground utility for laying HT power cable below 8 meter from the normal ground level complete including HDPE pipe 110 mm PN8 PE100 type and jointing with HDPE sockets of suitable dia complete including inserting power cables of 95/120 Sqmm 3 core HT cable inside the 110 MM bore HDPE pipe complete all as specified and directed by Engr-in-Charge. Note- Rate quoted by Contractor is deemed to be included for the following :- (i) HDD Boring/drilling 6 meter depp from normal ground level. (ii) HDPE pipe 110 mm bore PN8 PE100 type including jointing as per site requirement. (iii) Inserting HT cable 95/120 Sqmm 3 core power cable and taken out other end (iv) Any permission required if any from NHAI/PWD, necessary action and departmental charges is levied by the Contractor. Note: (i) rate of cable will be measured and paid separately.(ii)rate of HDPE pipe is included in quoted rate.
M & L for cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sq mm to 95 Sq mm. Make- 3M/Denson/raychem
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 Sq mm to 95 Sq mm all as specified and as directed. Make- 3M/Denson/raychem
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 Sq mm to 95 Sq mm all as specified and as directed. Make- 3M/Denson/raychem
M & L for cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination Cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 Sq mm to 95 Sq mm all as specified and as directed. Make- 3M/Denson/raychem
Boaring holes horizontally under Road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 100 mm dia for passing of UG cable all as specified and as directed.(GI Pipe laid shall be measured seperately)
RELIABLE TRADERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .