Tender Value
₹48.9 L
EMD Value
₹50,000
Closing Date
2 Mar 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PWD Buildings Division Ernakula
o/o Executive Engineer PWD Buildings Division Ernakulam
This work is prepared for carrying out Electro-Mechanical works and using diffused aeration attached growth MBBR process for General Hospital, Muvattupuzha
2022_PWD_467795_3
TR/106377/2021_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
180 days
Muvattupuzha
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
Yes
₹50,000
Yes
23 Jun 2022
18 Feb 2022
4 Mar 2022
18 Feb 2022
2 Mar 2022
18 Feb 2022
18 Feb 2022 - 2 Mar 2022
60 days
Amount
Electro-mechanical Items for STP
OD82558/2021-2022:Supply of vent pipes of 150 mm dia with mosquito proof grating suitable for the ventilation purpose of the various tanks
OD82564/2021-2022:Providing and adding MBBR module of size Floating media Dia22mm x 15mmTransparent fluidized bio media cylindrical with external fins. Bio surface area not less than 400m2/m3. For MBBR tank compartment for Bio growth contact media
OD82586/2021-2022:Supply, installation, testing & commissioning of 1 Nos. Stainless Steel Perforated Corrugated Bar Screen of size 750mm x 900mm with suitable handle for lifting arrangement. 8 mm SS bar vertical 44mm c/c with frame size 25mm SS 306 square fitted comfortably inside the manhole cheamber.
OD82599/2021-2022:Supplying and erectingTwin lobe type rotary Air blowers casing - CI, shaft- Alloy Steel, capable of delivering 200 cum/hr (each) of free air at head of 0.5 kg/sq.cm driven through ?V? belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply and fixing corresponding push button with control cable up to panel board for emergency operation . ( motor should be not less than 5 HP)Approximately 5 hp motor No. of Blowers (2 Nos. ? 1 W + 1 S)make : Kay/A 1/ ABL
OD82935/2021-2022:Air dispersing system all including Providing and fixing all piping (as described below) and isolation control valves for making the system complete. All valve shall have flanged joints. Flange connection shall be provided wherever required. Flexible transparent Hose with control valves - All Submerged piping for air / water Non-clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from platform at the top. (Imported fine bubble membrane diffusers) Air dispersion system shall be provided for Sewage Sumps, Aerobic MBBR digester . Nos of diffusers not less than 12 nos in both compartment of MBBR tank
OD82940/2021-2022:Supply, installation, testing and commissioning of vertical self supporting Multigrade Sand Filter. Filter shall be constructed of FRP/composit material with inner shell of integrated Polyethylene with Fiber Reinforced Plastic as per manufacturer standard. The inner distribution system and the under bed draw off system shall be of Hub & Lateral type/Riser tube with top & bottom strainers of Polypropylene material. Filter shall be supplied with initial charge of Filter media like special graded sand with supporting media like silex, gravel etc. The filter shall complete with pressure gauge at inlet & outlet, sample cock, PVC face piping/interconnected piping, Valves and all necessary accessories. Flow rate : 15 Cum/hr Filtration velocity : 20 cum/hr/sqm Max. operating pressure: 3 kg/sq.cm Test pressure: 3-5 kg/sq.cm Suggested Diameter : 1100 mm 1 No. (Working) make : CAP/IEL/THERMAX
OD82941/2021-2022:PARALLEL PLATE SETTLING SYSTEM INSIDE THE CLASSIFIER. Supply, installation, testing and commissioning of Plate settlers media to be installed in settling tank( above conical portion) . Tube settler along with suitable sludge removal arrangement This application of TUBE dek where solid retention is maintained for settling of sludge . TUBE dek is placed above the sludge blanket in the clarification( conical portion) zone of the settling tank . This maintains the required solid concentration in sludge blankets. either by pumps or any other suitable arrangement. 60? slope : 11 m2/m3. HEXAGONAL-CHEVRON type
OD82942/2021-2022:Supply, installation, testing and commissioning of vertical self supporting Activated Carbon Filter. Activated Carbon Filter shall be constructed of FRP/composite material with inner shell of integrated Polyethylene with Fiber Reinforced Plastic as per manufacturer standard. The inner distribution system and the under bed draw off system shall be of Hub & Lateral type/Riser tube with top & bottom strainers of Polypropylene material. Filter shall be supplied with initial charge of media silex, coarse sand, activated carbon granules Media ,etc. The filter shall be complete with pressure gauge at inlet & outlet, sample cock, PVC face piping/interconnected piping, Valves and all necessary accessories. Flow rate : 15 Cum/hr Filteration velocity : 20 cum/hr/sqm Max. operating pressure: 3 kg/sq.cm Test pressure: 5 kg/sq.cm Suggested Diameter : 1100 mm 1 No. (Working)
OD82944/2021-2022:Providing and fixing chemical dosing sytem with dosing pump electronic diaphragm type dosing pump, agitataor dosing pipeline dosing tank of HDPE syntax white tank of 100literes with stirrers and motor etc all as per the instruction of the STP consultant. Alum dosing system of 4 lph
OD82957/2021-2022:Supply of plastic manhole step/foot rest (@ 300 mm c/C) with polypropylene compound injection molded around 12 mm dia (Fe-415) steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessibility. The installation of the foot rest shall be done by the civil contractor .
OD82960/2021-2022:Providing and fixing cast iron double flanged butterfly valves complete with bolts, nuts, 3.0mm thick compressed asbestos gasket. 40mm dia
OD82962/2021-2022:Providing and fixing cast iron double flanged butterfly valves complete with bolts, nuts, 3.0mm thick compressed asbestos gasket. 50mm dia
OD82963/2021-2022:Providing and fixing cast iron double flanged butterfly valves complete with bolts, nuts, 3.0mm thick compressed asbestos gasket. 65mm dia
OD82967/2021-2022:Providing and fixing cast iron double flanged butterfly valves complete with bolts, nuts, 3.0mm thick compressed asbestos gasket. 80mm dia
OD84047/2021-2022:Providing and fixing flow meter for measuring the out let flow not more than 20000 lph with display of cumulative reading and per hour flow rate
OD82976/2021-2022:Providing and fixing chlorine dosing system with electronic diaphragm type dosing pump, dosing pipeline dosing tank of HDPE syntax white tank of 100literes with all as per the instruction of the STP consultant. Chlorine dosser 4 lph
OD83296/2021-2022:Providing, fixing, testing & commissioning of Electric control Panel for the above items( except Submersible pump fro pumping from interim collection tank item no 19) all inclusive as detailed below: The rates for the control panels apart from the switches and instruments shall also include the following : Supporting rigid steel frame work. Cubicle type, 2mm thick CRCA sheet steel enclosed. Complete with interconnections and distribution bus bars. Proper bonding to earth. Painting / Lettering on switches and control panels, the location they serve, providing on each panels its circuit diagram. Control Panel shall be painted with light grey paint shade No. 631 of IS - 5 All Panels shall have provision for the following : Padlocking of panel doors. Padlocking of MCCB's handles in 'OFF' position. Providing cable clamps / supports within panels cable alley .TPN MCCB shall means 3 Pole MCCB with separate neutral link of adequate size. All MCB's shall be minimum 10 kA breaking capacity. The breaking capacity of MCCB's are mentioned panel wise. All MCCB's shall be provided with static release and setting plugs.All motor feeders MCCB's shall be of motor duty. A separate energy meter is to be provided at the end of the control panel for the items fitted/Installed inside the control room for the measurements of power comprises of different pumps , motors and blowers inside the pump room Degree of protection for following type of distribution panel enclosure shall be as per IS 13947 - 1993.IP 42 for indoor panels. IP 55 for outdoor panels.All MCCB shall be provided with operating mechanism for door interlock. Minimum bus bar cross section shall be required for following fault level. 50 x 6 mm Aluminium for 20 kA. 1 Sec.Current density of Aluminium shall be 1 Sq. mm for 1 Amp fire rated current of bus bars. GI flat earth bus shall be provided through out the length of each panel
OD84074/2021-2022:Supply, installation, testing & commissioning of CI Medium duty rectangular manhole cover with frame for the feasibility of access in the tanks
OD84091/2021-2022:Supply of MS hot dip galvanized puddle flanges in accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out at the required levels & position; under the supervision of the STP consultant as per the position of pipes required to insert.
OD84097/2021-2022:Providing, fixing, testing & commissioning of fully submersible, centrifugal non-clog type sewage handling pumps capable of handling solids up to 30-40mm for raw sewage transfer from each interim collection tank located at distant places under ground tank tank with pump house to Central collection tank . The pump shall have CI casing & impeller, SS shaft, TEFC induction motor including lifting arrangement with SS chain , Hooks, and permanent lifting arrangement for the pump at the side of the MH chamber , all necessary piping (flexible pipe with coupling), delivery header valves, tube type level cut off arrangements , level controller with wiring to control the level of sump automatically. etc. Equalized Waste Water Transfer Pumps : 1 set contain (2Nos. - 1 W +1 S) Flow rate (each) = 6-10 m3 / hr Approximate HP- 2 HP ( AS PER MANUFACTURERS SPECIFICATION) Head = 15-20 Mtr Solid Handling = 20-30mm Type of Pump - Centrifugal non-clog sewage handling type submersible pump with starter , switch, local push control switch on/off cable level switch dry run cutoff etc
OD84103/2021-2022:Providing, fixing, testing & commissioning of horizontal, centrifugal Sludge Re circulation Pump for the disposal of sludge to settling tank to sludge holding tank and Aeration MBBR tank. The pumps shall have CI casing, CI Impeller, SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, supply and fixing corresponding push button with control cable up to panel board for emergency operation100 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads necessary piping, valves and other accessories complete as required. Sludge Transfer / Re circulation pumps 1 set contain (2Nos. - 1 W +1 S) Flow Rate (each) - 8 m3 / hr Head - 10-12 Mtr Solid Handling - 10-20 mm Make Kirloskar/KSB/ Crompton
OD84120/2021-2022:Providing, fixing, testing and commissioning of filter feed pumps for filtration. The Centrifugal, self priming mono-bloc sewage pumps shall be made of C.I. body and bronze impeller, shaft of carbon steel and C.I. Base & head, mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply mounted on a common channel base frame with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design including all necessary piping, suction and delivery header supply and fixing corresponding push button with control cable up to panel board for emergency operation, individual suction & delivery of pump valves, NRV, pressure gauge and other accessories and concrete foundation complete as required. Capacity : 15 Cum/hr. Head : 25 - 30 Mtrs Type of Pump : Horizontal Centrifugal pump Approximately 2 hp No. of Pumps (2 Nos. ? 1 W + 1 S) Make: Kirloskar/KSB/ Crompton.
OD84125/2021-2022:Supply erection and commissioning of sewage lifting pump from Interim collection tanks located in a distant place not more than 100 meters horizontal distance . Centrifugal non-clog sewage handling type submersible pump of capacity not more than 15000 LPH with 12 meters head with starter , switch, starter cable level switch dry run cutoff etc . ,DRY RUN CUT off arrangement - 1 Nos., Starter switch etc 3 hp approximate
OD84141/2021-2022:Maintenance of the STP for one year including labour and chemicals .(2 shift of skilled operator (Alum,Chlorine and Bacteria)
pipe laying works
19.7.1.2:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885
19.8.1.1:Extra for depth for manholes Size 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
19.30.2.1:Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
19.31.2.1:Extra for depth beyond 45 cm of brick masonry chamber: For 500x700 mm sizeWith common burnt clay F.P.S.(non modular) bricks of class designation 7.5
19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.31.1.1:Extra for depth beyond 45 cm of brick masonry chamber: For 455x610 mm sizeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.7.2.2:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With Sewer bricks conforming to IS : 4885
19.25.2:Extra for depth of manholes dismantled:Rectangular manhole 120x90cm and beyond 90 cm depth
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
18.9.6:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes
50.18.9.5.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2
50.18.9.6.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
50.18.9.8.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
FLOWMAX WATER
Bidder Name
FLOWMAX WATER
M/s MadeckalContructions
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .