Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.7 L+₹3.6 L (27.2%)Rejected-Finance MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 May 2022, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR/ MAINT OF DG SET, AMF PANEL STABILIZING, APFC PANEL AND OTHER MISC WORKS AT DARJIPURA AF STN BARODA
2022_MES_521425_1
8706/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹40,000
Yes
21 Jul 2022
2 May 2022
1 Jun 2022
2 May 2022
30 May 2022
17 May 2022
3 May 2022 - 10 May 2022
Amount
M&L for annual maintenance/ servicing and repair of standby DG Set of following capacity i.e KVA maintenance schedule prescribed in repair and maintenance mannual (Repair & maintenance should be carried out by the manufacture's authorised mechanic from the servicing centre) including fixing charges for replacement of parts specified in relevent item here in after: NOTE : Servicing of DG set to be carried out by engineers of authorised dealer/service centre of kirlosker/greaves /cummins only Parts /components for replacement shall be measured and paid for seperately.
Checking and servicing/ repair and maintenance of :- (i) Lubricant oil leaking. (ii) Operation of oil heater and repair to lubricant oil leaking and cooling system leaking, radiator air restriction operation of coolant heater, hoses and connection, belt connection and tension. Fan hub drive pully and water pump heat exchanger, zinc anode plug motor operation louver and cleaning of water separator and cooling system. (iii) Leaking in air intake system,air cleaner restriction piping and connection. (iv) Fuel line and connection, fuel transfer pump, draining out fuel sidement from tank. (v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, torquing to exhaust manifold and turbo charger capscrew. (vi) Battery charging system level up electrolyte and specific gravity, repair and maintenance of safety control and alarm. (vii) Cleaning of engine lighting of all nut bolt washer and unusual vibration. (viii) Air inlet and outlet for restriction and proper connection to electric connection , operation of generator heater strip greasing to all bearing and movable part, measurement and recording winding resistance cleaning up complete generator. (ix) Complete reset switch in automatic lightning of connection, instrumentation.
Labour only for attending the DG set with AMF Panel complaints carried out by manufacture's authorised mechanic from the servicing centre without any delay with rectified the defects by carefuly opening and check the DG set parts which defects find out at site and replace the defected parts from the DG Set for smooth functioning as directed and specified by the Engr in charge at site (Replacement item shall measured and paid seperately)
Supply only the following spares in replacement/ fixing at site for DG sets
Fuel flexible pipe wire braded,1,1/4''to 3/8''PVC best quality.
Oil pressure gauge complete.
Oil pressure Switch complete.
Water temperature gauge
Ignition switch
Indicating lamp
Battery terminal heavy duty of brass.
Distilled water.
Coolant for radiator.
Oil filter
Fuel filter set.
Engine oil premium blue 20W 40 Make : Servo, Castrol or Equivalent make approved by GE.
Fan belt any capacity Make Fenner/ Dunlock or Equivalent make approved by GE.
Self starter 12 volts Make:Lucas/ Tvs or Equivalent make approved by GE.
Self starter 24 volts Make:Lucas or Equivalent make approved by GE.
Air Filter Make Mico, Boss or Equivalent make approved by GE.
AVR for 100 KVA DG Set
AVR 82.5 KVA DG Set
AVR for 50 KVA DG Set
AVR for 40 KVA DG Set
AVR for up to 30 KVA DG Set
Asbesto rope
Battery lead 1.5 metre long, heavy duty, multi stranded copper conductor, PVC insulated 16 Sqmm single core.
Battery Charger
Dynamo 12 volts Make- Lucas or Equivalent make approved by GE.
Fuel injector pump
Radiator
Solenoid Valve
Vibration pad
DG SET coupling 30 to 82.5 KVA
M&L for cleaning and descaling of radiator assembly by using suitable chemical (MAC solution) and by blower fan and by injecting water in high pressure in water tubings so as to remove all dirts etc in the fins complete all as specified and directed for following capacity DG set:-
M&L for replacement of battery 12 volts,150 AH complete. Make: Exide Express/Gold or Equivalent make approved by GE.
M&L for replacement of battery 12 volts,180 AH complete. Make:Exide Express/Gold or Equivalent make approved by GE.
M&L for replacement of Dry battery 12 volts,100 AH complete. Make:Exide Express/Gold or Equivalent make approved by GE.
Material and labour for Maintenance of AMF panel of and cleaning of dust inside with blower, cleaning of moving part /contacts from CT cleaner, tightening of loose parts /electrical wires, cleaning of contractors, relays and junction points, servicing/ adjustment of relay, complete testing of AMF relay with necessary settings and load management system complete with replacement of worn out unserviceable components /burnt wires thimbles /lugs complete tested For DG set up to 100 KVA complete all as specified and directed. Note :- Parts /components for replacement shall be measured and paid for seperately.
Supply only following spare parts in maintanance carried out above item No. 9.00 in existing AMF panels. (Rate for fixing charges are deemed to be included in the above item): -
Supply failure timer
Restoration timer
Microprocessor based AMF Module incorporating of supply and restoring timer 3 impulse automatic engine start /stop/ logic & fails to start locknut Mains/generator voltage, frequency sensing
Diod 25 Amp thread type
Axillary contactor 3 phase suitable for AMF Panel
NC/No realay complete
Under voltage relay
Time Delay relay
CT's coil 5/250 for 100 KVA DG Set
CT's coil 5/150 for 82.5 KVA DG Set
CT's coil 5/50 for up to 50 KVA DG Set
CT's coil 5/50 for up to 25 KVA DG Set
Contactor 4 pole 250 Amps for 100 KVA DG set
Contactor 4 pole 200 Amps for upto 82.5 KVA DG set
Contactor 4 pole 63 Amps for upto 50 KVA DG set
Battary charger in AMF Pamel
Controller for 82.5 KVA TO 200 KVA
Controller for 20 KVA TO 35 KVA
VMR 3 Phase for 82.5 KVA TO 100 KVA
Contactor relay for 82.5 KVA TO 100 KVA
Contactor relay for for 10 KVA TO 50 KVA
HRC fuse for short circuit protecton
Material and labour for painting of AMF panel with cleaning of dust inside with blower, cleaning of moving part /contacts from CT cleaner, , cleaning of contactors, relays and junction points for DG set up to 200 KVA complete all as specified and directed.
M&L in replacement for on load changeover switch of capacity including sheet enclosure and removing old changeover switch any type and necessary fixing on wall/in LT panel. Make:Havells, C&S, L&T or equivalent make approved by GE.
upto 63 KVA
M & L for removing existing old rusted paint on DG set of painted complete with two coats of synthetic enamel paint to match with existing colour good finish of following capaity complete all as specified and directed.
Repair & Maintenance of existing canopy of eco friendly DG Set above cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations and necessary spary painting with super enamelled paint of same colour of company pattern on indide and out side of canopy chamber after removing old painted/rusted surface complete all as directed.
Material and labour for providing wooden plank for battery of DG Sets complete all as specified and directed.
M & L for rewinding of DG set alternator of any capactity with existing size and gauge and adequate number of turns of super enamelled copper winding wire and bore conductor including varnishing insulating material drying baking heating and connection leads with thimble and making connection complete all as specified and directed.
Material and labour for shifting of DG set of any Capacity from old platform to new platform including provision of crane for lifting DG set including making new connection for AMF Panel to existing main panel of all as directed by Eng - in -charge.
Repair and calibration of Fuel pump Nozzle of any capacity complete all as specified and directed by Engr-in-Charge
M&L for Multifunction meter with scroling reading for water temprature/ oil pressure, voltage/ Ampere/ Frequency/ KW/ KVA and Running hour counter
M&L for dismantling defective Ammeter and replacement of new ammeter digital type complete with CT'S Make:AE/Conzeve /HPL or equivalent make approved by GE.
M&L in replacement for frequency meter analog type E/Conzeve /HPL or equivalent make approved by GE.
Supply and fix in repair of unserviceable MCCB,s of following capacity :-
M&L for MCCB 250 A 36 KA 4 Pole
200 Amps 4 pole 36 KA
160 Amps 4 pole 36 KA
125 Amps 4 pole 16 KA
100 Amps 4 pole 16 KA
63 Amps 4 pole 10 KA
Supply and fix in repair of unserviceable MCB,s of 100A 4 Pole complete all as specified and directed.
S&F in repair of u/s copper bus bar of any size of existing LT panel mounted on insulator incl cutting / drilling making connection and testing complete all as specified and directed.
Material and labour for reparing of LT panel door including replacement door handel, hinges, nut bolt, welding work complete all as specified and directed.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth for foundation etc and getting out in soft/loose/hard soil complete all as specified and as directed
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/ around cable complete all as specified and directed.
Supply and laying re-inforced precast concrete cable cover class LV, Type 1 flat size 250mmx150mmx40mm complete all as specified and directed.
M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to and including galvanised earth strip 32 X 6mm mm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and watering pipe(GI,light grade) 20mm dia,PCC pit with 50mm thick PCC cover etc. including testing on completing but excluding GI protection pipe for earthing lead complete all as specified and directed.
Material and labour for relacement of following old unserviceable parts and fixing new one for 20 KVA DG Sets complete all as specified and directed by Engr-in-Charge :
Battery Charging Alternator Make- Lucas/Autolek or Equivalent make approved by GE.
Starting Motor Repair Make- Lucas/Autolek or Equivalent make approved by GE.
Battery 88 AH Make Exide Express/Exide Gold
Fuel pipe
MCB 63 Amp 4 pole L&T/Havells/Schnieder
Contactor 3 pole 80 Amp Make- L&T/ABB/Siemens
4 ST Switch Make- Lucas or Equivalent make approved by GE.
AMF Controller of any capacity Make- Deepsea/procom or Equivalent make approved by GE.
Stop Solenoid switch Make : Mahindra & Mahindra/Greaves/Kirloskar
Timer Make : L&T/Schnieder or Equivalent make approved by GE.
M&L for annual maintenance/ servicing/ repairing, Testing and commissioning of 150 KVA Mico controller Stabilizer Note :- (i) charges for replacement of parts/Component will be measured and paid separately under relevant items. (ii) Servicing of Stabilizer to be carried out by engineers of authorised dealer/service centre (ii) If Any Types of Nut & bolt, Any sizes of Gasket or Hydera Machine or any veh reqd for carrying stabilizer from site to workshop To & Fro Rate will be iclusive in this quoted rate.
Supply and fixing the following spares in replacement/ fixing at site for Stabilizer :-
M& L for New Control Card installation with Fabrication work
M&L for installation of Pressure capacity 10 KG Motor
M&L for installation of Transformer internal BBT
M& L for installation of Dimmer Assembly
M&L for fixing Carbon brush
M& L for supply Transformer Oil/Voltage stabilizer oil
Labour Charges for Filteration of voltage stabilizer oil for required strength complete all as specified and directed.
M & L for installation of Trasnformer Control type
M/S HARI CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .