Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹31.3 LAccepted-Finance | ₹31.3 L | L2 | Accepted-Finance OK |
| 2 | L2₹32.1 LAccepted-Finance VILL MASON P O NANDPRAYAG DASHALI PIN 246449 | CHAMOLI | UTTARAKHAND | 246449 | ₹32.1 L | L2 | Accepted-Finance OK |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance GRAM POST KAPKOT DISTRICT BAGESHWAR UTTARAKHAND | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-GST CERTIFICATE NOT SUBMITTED |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance GRAM BHANGOTA NARAYANBAGAD DISTRICT CHAMOLI | CHAMOLI | UTTARAKHAND | 246401 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-GST CERTIFICATE NOT SUBMITTED |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance DEHRADUN | UTTARAKHAND | 248001 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-GST CERTIFICATE NOT SUBMITTED |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Dec 2024, 12:00 pmClosed
EE RWD CHAMOLI
EE RWD CHAMOLI
CONSTRUCTION OF THE BUILDING OF LASYARI UNDER PRIMARY HEALTH CENTER CHAMOLI
2024_RES_78486_2
2047/RWD/30.11.2024
Open Tender
Civil Works
Item Rate
365 days
GOPESHWAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
EE RWD CHAMOLI
₹76,000
20 Dec 2024
7 Dec 2024
16 Dec 2024
7 Dec 2024
16 Dec 2024
7 Dec 2024
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). of specified grade -All work upto plinth level excluding the cost of centring and shuttering - by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Random rubble masonry with Cement mortar 1:6 (1 cement : 6 coarse sand) with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) - All work upto plinth level excluding the cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work in Cement mortar 1:6 (1 cement : 6 coarse sand) with F.P.S. bricks of class designation 75 in foundation and plinth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto floor five level work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. excluding cost of centring, shuttering, finishing and reinforcement by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Foundations, footings, bases of columns, etc. including strutting,ropping etc. and removal of form for mass concrete. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts. including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Suspended floors, roofs, landings, balconies and access platform. including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
15 mm cement plaster on rough side of single or half brick wall of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers .including strutting,ropping etc. and removal of form by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble
Plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile C 10.14.2.1 Fixing with adjustable lugs with split end tail to each jamb
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality confoRmting to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3Kg/Sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Providing and fixing Ist quality ceramic glazed wall tiles confoRmting to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and fixing M.S. Tubular frames for doors, windows, ventilator sand cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, includin cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Renewing glass panes, with putty and nails wherever necessary Float glass panes of thickness 4 mm as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.With 12 mm mild steel U beading. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc 250x16 mm as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc 200x10 mm. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc 100 mm . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Light shade pigment using white cement
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (75 mm diameter ) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (110 mm diameter ) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories Coupler 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories Coupler 110 mm
Single tee without door 75x75x75 mm
Single tee without door 110x110x110 mm
75 mm bend
110 mm bend
Providing and fixing 15 mm nominal bore ball valve (brass) of approved quality complete. High or low pressure with plastic floats. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe (Flexible pipe 32mm dia) for sink or wash basin including P.V.C. as per direction of Engineer -in- charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (INTERNAL work) 15 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc (External) 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc (External) 15 mm dia nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing brass stop cock of approved quality 15 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 200 mm
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finished with a floating coat of neat cement complete as per standard design : as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given (With F.P.S. bricks)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Hand Packed stone filling in back of wallls including cost of all materials,royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:2:4
PRADEEP SINGH (BID ID -351200)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_93672.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .