| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹15.1 L+₹30,070 (2.04%)Accepted-AOC | L2 | Accepted-AOC HIGH |
Tender Value
₹16.6 L
EMD Value
₹41,493
Closing Date
27 Jun 2025, 5:00 pmClosed
ASSISTANT ENGINEER,AE OFFICE , CHERANELLOOR
ASSISTANT ENGINEER,AE OFFICE , CHERANELLOOR
GENERAL-Cheranelloor GP-Electrical Works at Community Hall-Electrification WorkGeneral Electrical Work
2025_LSGD_770382_1
T1/AE/CHR/2025-2026
Open Tender
Civil Works - Buildings
Item Wise
CHERANELLOR
GENERAL-Cheranelloor GP-Electrical Works
at Community Hall-Electrification WorkGeneral Electrical Work
9 documents required · 9 mandatory
₹2,760
Yes
₹41,493
Yes
21 Jul 2025
19 Jun 2025
30 Jun 2025
19 Jun 2025
27 Jun 2025
19 Jun 2025
19 Jun 2025 - 27 Jun 2025
Amount
ESTIMATE
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.2:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD523719/2024-2025:Supply of following size Surface mount LED panel light (Back lit Down light) fitting suitable for fitment in ceiling, with physical dimension approx. 600mm x 600mm. Back lit Down light, Make/Model: Philips-Full Glow -G6 or equivalent model of Osram/Bajaj / reputed make and model. Surface Mount LED panel Backlit down light 36W, Total Lumens Output - 4200Lm, 230V single Phase AC Supply.
OD523720/2024-2025:Supply of following size Surface mount LED panel light (Back lit Down light) fitting suitable for fitment in ceiling, with physical dimension approx. 300mm x 300mm size. Back lit Down light, Make/Model: Philips-Full Glow -G6 or equivalent model of Osram/Bajaj / reputed make and model. Surface Mount LED panel Backlit down light 18W, Total Lumens Output - 2160Lm, 230V single Phase AC Supply.
OD3981/2025-2026:Supply of following size recessed LED panel light (Back lit Down light) fitting with suitable metallic or Polyamide frame work for fitment in all type of ceiling materials, with physical dimension approx. 600mm x 600mm. Back lit Down light, Make/Model: Philips-Full Glow RC380B LED42S-G6 or equivalent model of Osram/Bajaj /equivalent reputed make and model. Recessed LED panel Backlit down light, W: 36W, Lumens output total: 4200Lm., 230V single Phase AC Supply.
OD4001/2025-2026:Supply of following size recessed LED panel light (Back lit Down light) fitting with suitable metallic or Polyamide frame work for fitment in all type of ceiling materials, with physical dimension approx. 300mm x 300mm. Back lit Down light, Make/Model: Philips-Full Glow G6/Osram/Bajaj/equivalent reputed make and model. Recessed LED panel Backlit down light 18W, Total Lumens Output-2160 Lm, 230V single Phase AC Supply.
90.3.11:Conveyance, installation, testing and commissioning of surface mounting down light fittings of all types directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
90.3.12:Conveyance and fixing charges of recess mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
OD4579/2025-2026:Supply of LED Type white / colour Skirtlight suitable to fix on the vertical wall side of staircase area, approx size 100mm x 60mm, inbcluding placing it's mounting box (metal sheet or polycarbonate) 230VAC- Make/Model: Legrand - Myrius Skirting Light With White /colour LED 3 M 6730 36 or equivalent make of Philips / Osram / Wipro / reputed make.
90.3.14:Conveyance, installation, testing and commissioning of foot light fittings / skirt light of all types directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD455449/2024-2025:Supply and providingLED Bulb 9W Make: Philips/Osram/Bajaj or equivalent
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.10:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
OD456343/2024-2025:Supply of the following sizes of Exhaust fan and giving connections with existing wiring - upto 305 mm sweep, light duty exhaust fan with self opening loweres / vent shutters, working in 230VAC Single phase supply.
OD456342/2024-2025:SITC of follwing type and size wall mounted fan 400mm sweep blades, High speed, High Flow, 90 degree of oscilation facility, handing chord for on/off the fan, wattage: 60-110 Watts, suitable for 220-240VAC supply, provided woth in build main cord. Make-Any reputed make like Cromption / Orient / Bajaj / or equivalent to Crompton model Torpedo 400mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD520813/2024-2025:Lifting Hook - 8/10mm SS
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD456341/2024-2025:Supply and installation of Wall fixing Clamp made of MS Rod / SS Rod with adaquate size for tying up the guy wire rope of the KSEB Service Wire to the building.
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
OD525577/2024-2025:4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands
OD525578/2024-2025:25 sqmm to 95 sqmm, 60 mm long x 20 mm wide x 1.20 mm thick Copper earthing clips for single compression glands
OD525572/2024-2025:Cost of 2 mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
9.1.12:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
OD5288/2025-2026:Supply, installation, testing & commissioning of Digital 3 Phase V-A-F Panel Board Meter 96mm x 96mm size, 230VAC Aux. supply, in the existing sheet steel enclosure, and making connections to lit as per requirement. Make & Model: Meco-VIF96U or equivalent models of L&K / AE / Rishabh/ Reputed Make. Digital 3 Phase VAF Meter 96mm x 96mm
OD5219/2025-2026:Supply, installation, testing & commissioning of LED Type Panel Board Indicator Lamp in Red Colour LED & Lens - 22.5mm Dia, 230VAC, in the existing sheet steel enclosure, and making connections to lit as per requirement. Make & Model: Teknic - 3PLBR4L, or equivalent models of L&K / Schneider / CS/ Reputed Make. LED Type Panel Board Indicator Lamp -Red.
OD5225/2025-2026:Supply, installation, testing & commissioning of LED Type Panel Board Indicator Lamp in Blue Colour LED & Lens - 22.5mm Dia, 230VAC, in the existing sheet steel enclosure, and making connections to lit as per requirement. Make & Model: Teknic - 3PLBR6L, or equivalent models of L&K / Schneider / CS/ Reputed Make. LED Type Panel Board Indicator Lamp -Blue.
OD5226/2025-2026:Supply, installation, testing & commissioning of LED Type Panel Board Indicator Lamp in Yellow Colour LED & Lens - 22.5mm Dia, 230VAC, in the existing sheet steel enclosure, and making connections to lit as per requirement. Make & Model: Teknic - 3PLBR4L, or equivalent models of L&K / Schneider / CS/ Reputed Make. LED Type Panel Board Indicator Lamp -Yellow.
OD17419/2025-2026:Supply, Installation and commissioning of Current transformer (CT) suitable for connecting to the existing Analouge or Digital Ammeter / Digital Multi function Meter / Watthour Meter / Watt Meter(DFM) etc, with CT Value from 50/5 to 500/5, VA-10VA, Cl.1 Ring type or Rectangular type, with fixing bracket or fixing clamps to fit on Panel boards sheet. CT 50/5 -500/5, 10VA
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
OD525593/2024-2025:Supply, installation, testing and commissioning of 125A, 4 Pole, 415V, Duty AC-23A, Manually opereated Change Over Switch with middle OFF position, open execution, to be fitted in existing panel board, suitable to 415V AC supply from KSEB & Genset, with standard accessories like Terminal shrouding, Source separator & Phase barriers, cable end box etc. Make: L&K, C&S, Havells or equivalent reputed make .
OD525575/2024-2025:Cost of First Aid Chart (Shock Treatment Chart) PVC laminated /duly framed
OD525576/2024-2025:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height
OD525608/2024-2025:Cost of 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint
OD525607/2024-2025:Cost of 6 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps
OD525606/2024-2025:Preparation of Electrical scheme including circuit diagram & allied drawings, submission of the same and obtaining necessary approval / Sanction from the concerned Electrical Inspectorate Department including Scheme scrutiny charges & Inspection fee, visit charges etc.
OD4096/2025-2026:Supply, installation, testing & commissioning of Fully automatic water level and Motor controller unit with water level monitoring facility at Sump Tank, OH Tank, Protection against Dry run of motor, suitable for the Pump motor capacity of 1.5 HP, 230V, AC 50hz, Make: V-Guard / Imagine / Viedeon/Reputed make.
OD4035/2025-2026:Supply installation testing and commissioning of 1.50 hp Horizontal type open well submersible motor pump set suitable for working 1 phase, 240V , 50 Hz AC supply having total head upto 25 mtrs, pump and pipe size 32 /25 mm, Make & model: Kirloskar - KOSI-1540, or equivalent make & Model like Crompton / V-Guard / Reputed make, including standard control panel and accessories.
OD4194/2025-2026:32mm Gun metal NRV Screwed end 40mm size-Cost of item
OD4124/2025-2026:32mm Ball Valve - Cost of item
OD4172/2025-2026:32mm 8Kg HD Pipe -Cost of item
OD4130/2025-2026:12 mm Nylon Rope -
OD4420/2025-2026:32mm HD Flexible Hose -Corrugated type
OD4407/2025-2026:(3core x 2.5 sq.mm PVC insulated PVC sheathed Flat cable
90.14.28.12:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 1.5 HP submersible motor pumps (DOL)
OD4701/2025-2026:Supply & Provide protection devices for UV/OV, Single phasing and Phase Sequence Reversal Protection at Generator input side of Automatic transfer switch (ATS) at the existing sheet steel metal enclosure, and incorporate the connections with ATS unit for safety of the generator set and commissioning the same including necessary relay output unit and wiring harness. Model & make: SM-501, L&K, or equivalent models of Siemens / Schneider etc. UV/OV proection devise for Genertor -415VAC
OD10996/2025-2026:Supply, Installation & Commissioning of 100A-AC1 Duty-4 Pole Power Contactor Conforms to IS: 60947-4-1 & IEC60947-4-1, in the existing enclosure and giving connections etc. as required, Make / Model: L&K/MCX-22, or equivalent models of Schneider/Siemens/C&S/Reputed make. - 4Pole Power Contactor-AC1 Duty-100A
OD11064/2025-2026:Supply of Spreader terminals suitable for 100A-AC1 Duty-4 Pole Power Contactor Conforms to IS: 60947-4-1 & IEC60947-4-1, Make / Model: L&K/MCX-22, or equivalent models of Schneider/Siemens/C&S/Reputed make. - Spreadse Terminal-4P 100A AC-1 Duty.
GK INDUSTRIES (BID ID -2232025)
Bidder Name
GK INDUSTRIES
Pattarumadathil Electricals
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1256967.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .