Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.1 L+₹17,729.20 (3.62%)Rejected-Finance ARGADA RAMGARH JHARKHAND 829101 | RAMGARH | JHARKHAND | 829101 | L2 | Rejected-Finance Techno-commercially not eligible | |
| 3 | Rejected-Technical BANK COLONY PATRAPALI BASTI RAMGARH JHARKHAND 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | - | Rejected-Technical Technically not eligible as per NIT |
Tender Value
₹5.8 L
EMD Value
₹7,300
Closing Date
16 Jun 2025, 11:00 amClosed
PE (EnM) GIDI C
Office of Project Engineer (EnM) , Gidi-C Colliery.
Erection and maintenance of poles, drawing of conductor and earth wire of 3.3KV Overhead line , Tree trimming for Overheadline and Flood Alarm system at Gidi C Colliery under Argada Area.
2025_CCL_337072_1
PE(EnM)/GDC/eNIT/2025-26/03 dated 06.06.2025
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Gidi-C Colliery
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,300
17 Oct 2025
6 Jun 2025
17 Jun 2025
7 Jun 2025
16 Jun 2025
7 Jun 2025
7 Jun 2025 - 14 Jun 2025
Amount
Part(A): Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace as required.
Erection of all AASC conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc. as required. (1.5 km X 342.51 kg/km)
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanished insulator fittings,ball and socket type and complete with galvanised strain clamps,bolts,nuts,washer etc. as required
Supply and erection of 11 KV pin insulator complete with large steel head GI pin, nut, washer etc. as required
Supply of 6 SWG G.I wire
Erection of G.I wires No-6/ 8 SWG including binding etc. As required.
Erection of Cradle Guard as required.(40 Nos. X 3 Span = 120 Nos.)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/cross arm for single 11 KV over head line conductor complete with 50 mm X 6 mm flat iron clamp,bolts,nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm(Angle iron bracket welded to the channel iron and complete with 50 mm X 6 mm M.S Flat iron clamps,bolts and nuts including drilling holes for insulator pins,bolts,nuts and washers etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) cross arm for 4 wire over head line complete with clamps,bolts and nuts and washers etc including drilling of holes for insulator pins etc and painting with primer and finished paint as required.
Erection of pole top/straight two wire/V shape two wire,angle iron/channel iron,cross arm on steel tubular / rail /PCC pole for 11 KV as required
Supplying of two length channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together ,including drilling holes for insulator pins/fittings,bolts, nuts and washers etc(as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11 KV over head line as required.
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height ,complete with 50mm X 6 mm M.S flats iron clamps, bolts and nuts including drilling holes for insulator pins,bolts and nuts etc and painting with primer and paint as required
Loading and Unloading of Poles
Part (B): Clearing jungle including uprooting of rank vegetation, grass, brushwood, trees and sapling sof girthup to 30cm measuredat a height of 1m or above ground level and removal of rubbish up to a distanceof 50m outside the periphery of the area cleared.
Part (C): Supplying and Fixing of Flood Alarm sysyem with Two Colour LED display,a waterprrof Box(including telemetry),an alarm light,a horn,a two metre pole
Supplying and Fixing of 2 core 6 sq.mm PVC insulated FRLS Copper Conductor
Total impact of GST for the purpose of CTC
M/S VAISHALI ELECTRIC COMPANY (BID ID -1161019)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .