Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-AOC KALARICKAL H ELAMBRA | KOTTAYAM | KERALA | 686001 | 1 | Accepted-AOC l1 | |
| 2 | 2₹2.0 L+₹30,456.54 (17.5%)Rejected-Finance VARAMBATHUKUDIYIL BLDG NELLIKUZHY P O KOTHAMANGALAM 686 691 | KOTHAMANGALAM | ERNAKULAM | KERALA | 686691 | 2 | Rejected-Finance l1 |
Tender Value
₹2.1 L
EMD Value
₹5,167
Closing Date
19 Aug 2025, 5:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
LSGD SUB DIVISION KOTHAMANGALAM
Kothamangalam Block Panchayath Project Number SO103/26-Nellikkuzhy Gramapanchayath Kottappedika Drinking Water Scheme Cmplection - Providing Motor pumpset-General Electrical Work
2025_LSGD_783055_1
KMBP SO103/26
Open Tender
Electrical Works
Item Rate
KOTHAMANGALAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹555
₹5,167
30 Sept 2025
7 Aug 2025
21 Aug 2025
7 Aug 2025
19 Aug 2025
7 Aug 2025
7 Aug 2025 - 19 Aug 2025
Amount
Providing Pump Set -
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
OD143830/2025-2026:Supply and fixing angle / straight brass lined skirt type, backelite batten holder with 7/9W LED and plastic shade and giving connection etc as required
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
OD143812/2025-2026: Supply, conveyance, errection, testing and commissioning of DECAN MAKE 10HP VERTICAL OPEN WELL SUBMERSABLE (HEAD-54 TO 156 MTR, DISCHARGE -14000 LPH) 10 HP Pump set working on 3 phase 415 V, suitably mounted on proposed 50 mm GI pipe etc as required or equallant make.
OD143808/2025-2026: Supply and provide L&T SUBMERSABLE STARTER 13- 21 A WITH PREVENTER with protection against overload, single phasing, phase reversal & severely unbalanced voltages conditions, in accordance with latest IS/IEC suitable for 10 HP Submersibles motor pump set complete duly internally connected
OD143817/2025-2026:Supplying, laying and jointing of the 50 mm sizes of pipes made out of HDPE 6 kg , P 63 conforming to IS 14930 Part II for water pipe etc as required
90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
OD143831/2025-2026:Supply and providing Cable Joint Tape etc. as required.
OD143820/2025-2026:Supply and Providing 50 mm or nearest size UPVC Adaptor Set DC CI with accessories etc
OD143824/2025-2026:Supply and fixing 50mmx 12" GI Barrel nipple
OD143814/2025-2026:Supply and fitting 50 mm or nearest size GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD143823/2025-2026:Supply and fitting 50 mm or nearest size Sluice valve on existing GI pipe with flanges etc
OD143828/2025-2026:Supply and fitting 50 mm or nearest size Non Return valve using required bolt and nut and flange etc
OD143829/2025-2026:Supply and providing clamp set CI 50mm Heavy
OD143810/2025-2026:Supply and fixing 25mm Ball Valve with 15mm nipple and 15mm socket duly welded as required
OD143826/2025-2026:S&I of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipe line as required
OD143821/2025-2026:Supply and fitting 50 mm GI socket etc. as required.
OD143813/2025-2026:Supply and Providing 50 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc
OD143815/2025-2026:Supply and provide NYLON ROPE MAXIMA LG 12MM or nearest size for hanging submersible pump set
OD143827/2025-2026:Supply and providing Cotton waste etc. as required.
OD143809/2025-2026:Supply and providing Shellac 50 ml etc. as required.
OD143811/2025-2026:Supply and fixing 20mm corrugated flexible pvc conduit
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD143819/2025-2026:Supply and providing 25x3mm brass nut and bolt etc. as required.
OD143816/2025-2026:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connection etc.
OD143825/2025-2026:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD143832/2025-2026:Supply and Installation of dust and vermin proof , wall mounting , Sintex 3 Phase meter box of size 650x350x250 mm suitable for fixing KSEB meter ,fuse units etc, hinged door connection for the front side with compartments if necessary , providing vision panel for the meter component , knock out for cable entry and exit.( GSMB?6535 )
OD143822/2025-2026:Supply and providing iron hook for binding service wire
SK ELECTRICAL (BID ID -2294822)
Bidder Name
K R ASOKAN
SK ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1285239.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .