Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.3 L+₹71,775 (5.69%)Rejected-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
2 Dec 2020, 3:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2020_MES_395155_1
8565
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹30,000
Yes
19 Jan 2021
13 Nov 2020
4 Dec 2020
13 Nov 2020
2 Dec 2020
20 Nov 2020
17 Nov 2020 - 19 Nov 2020
Amount
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for point wiring with multistranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code including PVC casing caping. the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit for One light point controlled by one one/way switch complete.
All as per item No. 3 above but for One Fan point controlled by one one/way switch.
All as per item No. 3 above but for One 3 pin 5 Amps socket outlet on same board with other switch.
All as per item No. 3 above but for One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
All as per item No. 3 above but for One light point controlled by two way switches
All as per item No. 3 above but for One bell point controlled by one way switches
All as per item No. 3 above but using 4 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board
M&L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed all as directed.
All as per item No. 10 above but using 4 Sqmm cable single core copper.
Taking down U/S FTL and S&F 4' 18W LED Tube With Batten with system lumen output of 1800 lumens, System Efficacy should be > 115lm/ W, The Luminaire Should have Cool Day light Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace, PF>0.95 Surge Protecton of 3KV, All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS etc. complete.
M&L switch piano flush type single pole one way 5 Amp 240 Volts.
M&L switch piano flush type single pole two way 5 Amp 240 Volts.
M&L switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt.
M&L switch socket combination 3 pin 5 and 15 Amp 2 in one flush with inbuilt indicating lamp.
S&F Bell switch including Bell ding dong type, one way, 240 volts, AC, ISI marked.
M&L ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked.
M&L for opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enameled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200.1400mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 1.7/2.5mfd and making connection with fan capacitor and connector block,Including Painting fan and blade with super enamelled paint of two coats and marking of MES No, transoporting back after repair, assembling the blades and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning complete. Note : Quoted rate deems to inclusive of rate of fan capacitor, fan bearing and transporatation charges.
M&L for opening covers of Exhaust fan 300mm, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armeture coil with complete shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 1.7/2.5mfd and making connection with fan capacitor and connector block, Including Painting fan and blade with super enamelled paint of two coats and marking of MES No,transoporting back after repair, assembling the blades and fixing the fan in its own position to existing fan clamp with necessary Nut, bolt and washer and testing for smooth functioning complete. Note : 1. Quoted rate deems to inclusive of rate of fan capacitor, fan bearing and transporatation charges.
S&F in repair energy efficient 5 star rated ceiling fan 1200mm sweep, single phase 230/240 volts AC and connecting up to including provn of porcelain connector and flexible three core copper conductor of size 23/0.0076 from ceiling rose or connector to ceiling fan and testing on completion complete.
M&L in repair TPN DBs Vertical type 4 way with provision for FP as incomer and SP as outgoing IP 43-IK 09 with metal door etc. complete.
M&L in repair sheet metal enclosure for single pole and neutral 08 way 240 voilts, 100 Amp rated bus bar IP 43 - IK -09 etc. Complete.
S&F MCB TPN 63 Amps 35 KA rupturing capacity complete.
S&F MCB SPN 32 Amps 10 KA rupturing capacity complete.
M&L for MCB SP 5 to 30 Amp 240 Volts
S&F connecting resistance type fan regulator A/C 240 Volts.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 32 Amps.
M&L for KAPITRODE Earthing with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25x5mm dia galvanised iron strip including the following, : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450x450x450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost..
S&F wall security light LED type complete with GI bend 1.2 mtr and fixing on wall/pole with clamp, nut & bolt complete. .
S&F of 7W LED Bulb with system lumen output of 600 lumens, System Efficacy should be > 85lm/ W, The Lamp Should have Cool Daylight Color temp of 6500K, Lamp should be supplied with E27 Holder. (Similar to Philips Ace Saver.)
S&F of 9 W LED Bulb with system lumen output of 600 lumens, System Efficacy should be > 85lm/ W, TheLamp Should have Cool Daylight Color temp of 6500K, Lamp should be supplied with E27 Holder. (Similar to Philips Ace Saver.)
S&F of 14 W LED Bulb with system lumen output of 600 lumens, System Efficacy should be > 85lm/ W, The Lamp Should have Cool Daylight Color temp of 6500K. (Similar to Philips Ace Saver.)
S&F electronic ballast suitable for tubelight of 40 Watts complete.
S&F AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A, Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards complete.
S&F 4' feet LED 1X20W LED tube rod on replacing existing 36/40watt fitting, with system lumen output of minimum 2000 lumens suitable for G13 holder with single side connection. The Luninaire should have cool daylight color temp 6500K, CRI >80, PF >0.95, Life class of 40,000 burning hrs with 70% lumen maintenance, Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection > 2 KV. LED to mounted on Rod and not directly on the surface of the tube. All the photometrical & electrical parameters must be supported by LM 79-08 test report from NABL accredited LAB or UL switching cycle of 50,000 times. The LED tube light conforms to applicable IS 10322/EN 60598,
Taking down and refixing storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/35 ltrs of any type and make, checking the serviceablity of all parts such as inner vessel, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly (considered as one unit) and installing and testing the same complete. (Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below)
Supply only for replacement of heating elements, 1.5 KW 230 volts
Supply only thermostat immersion point type 15 Amps, 230/250 volts/AC ISI marked
M&L switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt.
M&L switch socket combination 3 pin 5 and 15 Amp 2 in one flush with inbuilt indicating lamp.
S&F in repair storage, vertical type water heater including heating element, all accessories, fixing arrangement etc complete of capacity 25 ltrs all as Specified
M&L for providing suitable T&P and tradesmen to carry out IR/voltage drop/cricuit tests of complete internal wiring of Md Accn(One Qtr) and filling all related columns of form as per Appx 'G' complete all as specified and directed(Note : Rate deemed to be included for disconnecting all electrical connections and reconnecting the same after completion all specified tests and testing for smooth functioning after completion of Job)
M&L for providing suitable T&P and tradesmen to carry out Earth test of Earth pits of Md Accn building Distribution boards and filling all related columns of form as per Appx 'H' complete all as specified and directed (Note : Rate deemed to be included for disconnecting earth test point connections and reconnecting the same completion of Job)
M/s. RAMESH NARHARI VALEKAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .