Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC TEACHERS COLONY RANIBAG DISTT RAMGARH PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Techno Commercially Accepted L1 Bidder | |
| 2 | L2₹6.7 L+₹14,230.80 (2.18%)Rejected-Finance PURANA CHIEF HOUSE GIDDI A 829108 HAZARIBAGH JHARKHAND | RAMGARH | JHARKHAND | 829108 | L2 | Rejected-Finance Rejected Since L2 Bidder |
Tender Value
₹6.3 L
EMD Value
₹8,000
Closing Date
19 Aug 2024, 10:00 amClosed
SO EnM Argada Area
GM Office Argada Area
Different works of LT/ HT Overhead Lines such as repair, maintenance, dismantling, shifting, erection etc. for maintaining reliable power supply to GM(A) Office, Residential Colony, AKC Hospital, Regional Store etc. as non-destination basis to meet t
2024_CCL_314112_1
SO(EnM)/AA/eNIT/24-25/02
Open Tender
Electrical and Maintenance Works
Item Rate
185 days
GM UNIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,000
2 Jan 2025
2 Aug 2024
20 Aug 2024
3 Aug 2024
19 Aug 2024
3 Aug 2024
3 Aug 2024 - 10 Aug 2024
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Above 11.00 metre and upto 13.00 metre. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for one 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of AASC/AAC/ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 11.0 metre. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required . (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required . (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of AASC/AAC/ACSR of 7/1.96 mm to 7/3.15 mm diameter including binding etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Supply of 6 SWG G.I. wire ( For Earth Contuinity Conductor) (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Erection of G.I. Wire No. 6/8 SWG including binding etc. as required. (For Earth Contuinity Conductor) (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. (Refer CPWD General Specifications for Scope, Standards for Work and Measurement Criteria) (Higher/Better specifications of any parameter is acceptable)
Total impact of GST for the purpose of CTC
M/S UDAY SINGH and BROTHERS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_325507.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .