Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC 77 1 DAKSHINBARA ROAD BAGUIATI KOLKATA 700028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC OK | |
| 2 | L2₹34.7 L+₹2.8 L (8.87%)Rejected-Finance | L2 | Rejected-Finance Disqualified | |
| 3 | L3₹40.1 L+₹8.2 L (25.8%)Rejected-Finance P O DHAP DHAPI MALLICKPUR P S BARUIPUR 24PGS S PIN 743387 | 24 PARAGANAS SOUTH | WEST BENGAL | 743387 | L3 | Rejected-Finance Disqualified | |
| 4 | L4₹41.3 L+₹9.5 L (29.7%)Rejected-Finance | L4 | Rejected-Finance Disqualified | |
| 5 | L5₹42.0 L+₹10.1 L (31.8%)Rejected-Finance TARULIA 3RD LANE P O KRISHNAPUR KOLKATA 700102 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700102 | L5 | Rejected-Finance Disqualified |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
9 Dec 2022, 6:55 pmClosed
Executive Engineeer (E)
NKDA Administrative Building
Electrical Installation work for 12 nos EV Chargers at different location of New Town Under NKDA.
2022_NKDA_426571_1
NIeQ No. 31/EE-E/NKDA/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
New Town Under NKDA.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1 L
23 Dec 2022
25 Nov 2022
12 Dec 2022
25 Nov 2022
9 Dec 2022
25 Nov 2022
Amount
Supply and delivery of 1.1 KV Grade XLPE insulated 4C 300 Sqmm Al Ar cable [Make:KEI/Havells/RR/Polycab]
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [300 Sqmm][From WBSEDCL Meter to Feeder Pillar]
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [4C 300 Sqmm]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :[4 C 300 Sqmm]
Supply and delivery of 1.1 KV Grade XLPE insulated 2C 10 Sqmm Al Ar cable [Make:KEI/Havells/RR/Polycab]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed[2C 10 Sqmm][From Feeder Pillar to SPNDB Inside Metering Kiosk]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish[From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.][2C 10 Sqmm]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :[2C 10 Sqmm]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :[2C 10Sqmm]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supply, Erection, Testing and commissioning of double door feeder pillar (With Suitable foundation) outdoor type, stand mounting, dust and vermin proof feeder pillar with IP-55 protection.The panel shall be made out of 14 SWG Cold Rolled Close Annealed (CRCA) Sheet Steel. Panel shall have 2 coat of zinc chromate primer and 2 coat of epoxy paint both inside and outside.Cable entry shall be at the bottom and through a detachable gland plate of minimum thickness 8mm . Feeder pillar shall have pad-locking arrangement.The dimensions of the panel shall be at least 1000mm (L) X 500mm (B) x 1500mm(H).Panel should be constructed by CPRI certified fabricators.Necessary arrangements should be made for inspection of feeder pillar. Incomer: 320A FP 25KA/35KA MCCB as per GS(Make- L&T/Legrand/ABB) Bus Bus Bar: 4X65X13mm 415A Al Bus bar of 0.5m length as per PWD specifications.& F 415V 250A FP 25kA/35kA MCCB (L&T/Siemens/Legrand/ABB) -- 01 no.[For EV Charger] b) S & F 415V 40A FP 10KA & C Curve MCB on din rail (L&T/Siemens/Legrand/ABB) -- 03 nos.[For Merering room EI-01No,Compound light-1No,Spare-01No] N.B:Incorporate 25 A 2pole power contractor(1No) and Digital time switch(1No) as per direction of EIC for compound light(Make:L&T/Siemens/ABB/Legrand) CABLE ALLEY: cable alleys on both sides for out going connection are to be made incl. S & F suitable nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with ssuitable size stranded copper wire & copper bars as per the switch rating as specified in Interconnection. INTERCONNECTION: Inter connections to be made same witha. 4X50X10mm Al strip from Main bus bar of 415A to 320A Incomer MCCB.b. 4X20X5mm Al stripfrom Bus Bar of 415A to 32A Outgoing MCB. c. Metering circuit with 1.5 sq mm single core stranded FR PVC copper wire (Make - RR/Havells/Finolex/Polycab) with proper copper socketing & taping ( R Y B & N). READING ARRANGEMENT: a) Supply & Fixing 0-500V( L&T/ABB/AE/Similar)..1 No b)Supply & Fixing 0-500A( L&T/ABB/AE/Similar) .. 1No c) 320A/5A CT Coil ( Kappa Make Class -I) - 03 nos
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[Make-Legrand/Similar][2+12 Way]
Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection.[DP 40A][Make:Legrand/L&T/ABB]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.[12 Nos,SP6-32A [Make:Legrand/L&T/ABB]
Supplying and fixing 25mm size PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish(Avg Run 6 Mtr)
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Erection of CC Foundation of 1.5m(L)X0.8m(B)X1m(H),0.5m below and 0.5m above Ground level) for placement of outdoor feeder pillar.
Supply and fixing of 09W LED Lamp with holder on wall with all necessary interconnections and earthing attachment.[Make:Crompton/Philips/Havells][Angular Batten]
Supply and fixing 400 mm Sweep Wall bracket fan[Make-Crompton/Orient/Havells][Orient Wall 43/Similar]
Supply and erection of foundation for compound light
Supply and installation of 5mtr GI Octagonal pole with base plate,loop box and all conventional accessories [Make:-Bajaj/Transrail/Valmont]
Supply & Fixing of 120-300V,5700K,IP66,4KV Internal Surge Protection,10KV SPD,40W LED Outdoor luminaries[Make-Crompton/Philips/Havells]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC[SPNDB to 16 A PP]
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum?Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[175 mm x 100 mm x 65 mm]
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
Supply & Fixing 240 V , 20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works[13 mm dia 3 mm thick polythene pipe with 1x16 SWG GI earth continuity wire]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required[80 mm Dia]
Supply and fixing of 415 V , 315A, 2 m Long 4 x 50x10mm Al strip on Insulation chair incl Supply and fixing of Necy nut, bolt,washer,insulator etc.
Supplying and fixing 415 V,300A/320A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing Panel and necessary connection
Microtunnelling of 300 Sqmm Al Ar cable through suitable HDPE Pipe including supply of Supply of HDPE Pipe.
Laying of 300 Sqmm Al ar cable throung microtunnelling
REVEAL
PUSPA ELECTRIC
GHOSH ELECTRIC
M/S DEEP ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .