| 1.00 | Repair to the 15 TR capacity Ductable Air conditioning unit including allied works installed at Ortho OT of GMC&H Jammu by way of dismantling of the damaged compressor -01 No. of 7.5 TR capacity from package air conditioning unit after closing all required valves, disconnecting all electrical connections from the main panel and disengaging all piping connections etc. The job includes providing, fitting & installation of 01 No. new scroll compressor of 7.5 TR capacity (Danfoss/Emerson or any equivalent make) in place of the damaged compressor of the package unit, making all electrical connections, checking of alignments. Then performing the leakage test by applying soap water solution over condenser coils at leakage spot by way of copper brazing. Then checking of leakages in copper piping circuit by filling nitrogen gas in the system at a pressure of 1.5 times the operating pressure and holding the pressure for 24 hrs. The entire system is to be first tested at low pressure and then at high pressure to make sure that there are no more leaks in the system and then vacuumising the system with deep vacumising, up to 30 microns & charging of R-22 gas 16 Kg in the new installed compressor and topping up the other compressor of the package unit, maintaining required suction & discharge pressures. The job also includes replacement of damaged 03 No’s heating elements with fins of 3 KW capacity each, V-Belts in place of damaged ones and also replacement of damaged internal wiring of panel. Complete job includes cost of material, taxes, skilled labour charges, to and fro charges etc and testing of package air conditioning unit on full load after repairing the unit. Complete job | 1 | JOB | 0.02 ₹1.8 L | 0.02 ₹1.8 L | 0.02 ₹1.8 L |
Tender Value
₹1.9 L
EMD Value
₹4,000
Closing Date
16 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Repair to 15 TR capacity Ductable Air conditioning unit including allied works installed at Ortho OT in GMCH, Jammu.
2026_PWDJK_309558_1
MHDJ/e-NIT 34 of 2026-27
Open Tender
Repair and Maintenance Services
10 days
GMCH
AS PER E NIT
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹4,000
12 Jun 2026
8 May 2026
18 May 2026
8 May 2026
16 May 2026
9 May 2026
8 May 2026 - 16 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repair to 15 TR capacity Ductable Air conditioning unit including allied works installed at Ortho OT in GMC&H, Jammu
MHDJ/e-NIT 34 of 2026-27 Dated: 08.05.2026 Due : 16.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Repair to the 15 TR capacity Ductable Air conditioning unit including allied works installed at Ortho OT of GMC&H Jammu by way of dismantling of the damaged compressor -01 No. of 7.5 TR capacity from package air conditioning unit after closing all required valves, disconnecting all electrical connections from the main panel and disengaging all piping connections etc. The job includes providing, fitting & installation of 01 No. new scroll compressor of 7.5 TR capacity (Danfoss/Emerson or any equivalent make) in place of the damaged compressor of the package unit, making all electrical connections, checking of alignments. Then performing the leakage test by applying soap water solution over condenser coils at leakage spot by way of copper brazing. Then checking of leakages in copper piping circuit by filling nitrogen gas in the system at a pressure of 1.5 times the operating pressure and holding the pressure for 24 hrs. The entire system is to be first tested at low pressure and then at high pressure to make sure that there are no more leaks in the system and then vacuumising the system with deep vacumising, up to 30 microns & charging of R-22 gas 16 Kg in the new installed compressor and topping up the other compressor of the package unit, maintaining required suction & discharge pressures. The job also includes replacement of damaged 03 No’s heating elements with fins of 3 KW capacity each, V-Belts in place of damaged ones and also replacement of damaged internal wiring of panel. Complete job includes cost of material, taxes, skilled labour charges, to and fro charges etc and testing of package air conditioning unit on full load after repairing the unit. Complete job 1 JOB Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_1002049.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid