Design, Supply, Erection, Testing & Commissioning of 2x25 OHE for modification due to ROB under CGM/DDU UNIT.
DFCC-DDU-EL-US-OHE-T10R1~EDFC
DFCC-DDU-EL-US-OHE-T10R1
Open
Works - General
12 Months
Chandauli, Uttar Pradesh
₹5,900
₹1.1 L
22 Dec 2025
29 Nov 2025
8 Dec 2025
Foundation work : Providing and laying of concrete for foundation and plinth in all type of soils using M-15 grade concrete for main foundation and M-20 Grade of concrete for grouting and muffing including nominal reinforcement wherever required as per RDSO drawings including muffing.
Excavation for structure-Excavation in all type of soils and soft hard rock/ concrete /masonary/drains/walls
Providing and fixing Cenering and Shuttering incuding oil for casting concerete including frame work whereever necessary.
Erection of rolled or fabricated and galvanized Traction Masts /TTC /Portal /Bridge Mast/Dwarf Mast/Gantry etc.
Supply of rolled fabricated Galvanised steel structures (i.e.B series mast, TTC, Bridge Mast,AT mast,Dwarf mast and Portals)
Supply only of fabricated & galvanised steel work other than masts including SPS.
Erection of fabricated & galvanized steel work other than masts including SPS.
Supply of single bracket assembly.
Erection single bracket assembly.
Supply of Stay tube and Bracket Tube Composite Insulator set CD-1600mm
Erection of Stay tube and Bracket Tube Composite Insulator set CD-1600mm
Supply of OHE with complete fittings without Contact and Catenary Wire.The unit of measurement, KM is treated as TKM.
Erection of OHE with complete fittings with Contact, Catenary Wire, Fedder wire and AEW. The unit of measurement, KM is treated as TKM.
Supply of 09 ton Insulators (CD-1600mm)
Erection of 09 ton Insulators(CD-1600mm)
Supply of Retro-Reflective type number plate as per DFCCIL requirement including all fixing arrangement.
Erection of Retro-Reflective type number plate as per DFCCIL requirement including all fixing arrangement.
Supply of Danger/Caution Board, Un wired turnout board, Engine Stop board, Sigma board, Neutral section board, and other board as per DFCCIL requirement.
Erection of Danger/Caution Board, Un wired turnout board, Engine Stop board, Sigma board, Neutral section board, and other board as per DFCCIL requirement.
Supply of Single earth electrode with earth pit complete.
Erection of Single earth electrode with earth pit complete.
Supply of structure bond including rail clamp.
Erection of structure bond including rail clamp.
Supply of Catenary wire of 125 sqmm as per DFCCIL requirement.
Supply of Contact wire of 150 sqmm as per DFCCIL requirement
Supply of 150 sqmm Contact wire Splice as per DFCCIL requirement.
Erection of 150 sqmm Contact wire Splice as per DFCCIL requirement.
Supply of 120 sqmm Catenary wire Splice as per DFCCIL requirement
Erection of 125 sqmm catenary wire splice as per DFCCIL requirement
Supply only of longitudinal / inter Rail bond.
Erection of longitudinal / inter Rail bond.
Supply only of Transverse & special bond.
Erection of Transverse & special bond.
Supply of contact wire 150 sq mm /125 sq mm catenary wire End Clamp
Dismantling of Bracket assembly
Cutting and Removal of Existing Structure
Reclamation of OHE Mast/ Structure
Dismanteling of Fabriccated steel other than mast
Dismantling of OHE/Feeder Wire. The unit of measurement, KM is treated as TKM.
Dismantling of 09 Ton Insulator
Handling Loading/Unloading and transportation of DFC Supply/released materials such as Mast, Wires, Fittings, SPS etc. from from IMD/ISMD to site & Released materials from site to Above/
2-100 % Extra on erection Rate for work done under Power Block
Erection of rolled fabricated Galvanised steel structures (i.e.B series mast, TTC, Bridge Mast,AT mast,Dwarf mast and Portals)
Erection of fabricated & galvanized steel work other than masts including SPS.
Erection single bracket assembly.
Erection of Stay tube and Bracket Tube Composite Insulator set CD-1600mm
Erection of 09 ton Insulators(CD-1600mm).
Erection of OHE with complete fittings with Contact ,Catenary,feeder and AEW Wire.The unit of measurement, KM is treated as TKM.
Dismantling of Bracket assembly.
Cutting and Removal of Existing Structure
Reclamation of OHE Mast/ Structure
Dismanteling of Fabriccated steel other than mast
Dismantling of OHE/Feeder Wire.The unit of measurement, KM is treated as TKM.
Dismantling of 09 Ton Insulator Above/
3-Tower Wagon up keeping and maintenance Charges
Towerr wagon up keeping and maintenance Charges.Unit as per DFC requirement and quantity As per Actual.
Item Breakup - 1-OHE WORK
M-15 (Foundation)
M-20 (Grouting) Total 339381.63
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCCorrectionSlip.pdf
ATTACHMENT
TenderDocument_2.pdf
ATTACHMENT
NIT.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .