ABSTRACT OF COST
RS.) NON SCHEDULED
S.No. DESCRIPTION OF ITEMS (DSR Civil 2023,DSR
AMOUNT (IN RS.)
H&L 2025, DSR E&M
a. Art Gallery and Cafe 1,35,10,773.90 19,71,108.90
b Indoor & Outdoor Renovation 1,71,02,714.65 3,59,04,613.55
Total Cost of Civil Works (1) 3,06,13,488.55 3,78,75,722.45
2 ELECTRICAL & HVAC WORKS
a. Electrical-Auditorium 16,14,270.00 53,37,900.00
b. Facade Lighting 77,66,601.00 36,49,410.00
c. AV System & Networking, CCTV System 12,02,217.00 1,16,47,031.00
d. Lightning Protection System 3,03,502.00
Total Cost of Electrical & HVAC Works (2) 1,35,00,969.00 2,41,64,648.00
3 FIRE PROTECTION SYSTEM WORKS
a. Fire Safety (Sprinkler & Hydrant System) 10,94,309.00 95,822.00
c. Fire Alarm System 11,84,088.00 1,65,200.00
Total Cost of Fire Protection System Works (3) 38,77,136.00 2,97,897.00
Total(DSR+NON DSR) B 11,03,29,861.00
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
ART GALLERY AND CAFE
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
Earthwork Excavation.
Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, for all lift, including getting out
the excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.
a. DSR 2023 2.8.1 All kinds of Soil Cum 151.96 260.30 39,554.15
2 Back Filling.
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
watering, lead up to 50 and for all lift.
3 Sand Filling.
Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from
DSR 2023 4.1.6 natural sources : 6 graded stone aggregate 40 mm nominal size Cum 21.99 7,178.75 1,57,864.30
derived from natural sources)
5 Burnt Clay bricks Masonry (1:6) (in F & P).
Brick work with common burnt clay machine moulded perforated
modular bricks of class designation 12.5 conforming to IS : 2222
in exposed brick work including making horizontal and vertical
grooves 10 mm wide 12 mm deep complete in cement mortar
1:6 (1 cement : 6 coarse sand).
From ground level upto plinth level
6 Fly Ash bricks Masonry (1:6) (Superstructure).
Brick work with clay flyash F.P.S. (non modular) brick of class
designation 7.5 in superstructure above plinth level up to floor
five level in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
7 Fly Ash Half bricks Masonry (1:4) (Superstructure).
Half brick masonry with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in superstructure above plinth
level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
8 Antitermite Treatment.
Treatment of soil under existing floors using chemical emulsion @
one litre per hole, 300 mm apart including drilling 12 mm
diameter holes and plugging with cement mortar 1 :2 (1 cement Sqm 120.00 310.05 37,206.00
: 2 Coarse sand) to match the existing floor: With
Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland
Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including
pumping of concrete to site of laying, curing, carriage for all
leads; but excluding the cost of centering, shuttering, finishing
and reinforcement as per direction of the engineer-in-charge, for
the following grades of concrete.:
Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
a) Footing & Pedestal Cum 14.90 9,504.75 1,41,658.79
b) Column Up to Plinth Lvl :- Cum 2.43 9,504.75 23,096.54
10 Reinforcement.
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
11 Reinforcement.
Steel reinforcement for R.C.C. work including straightening,
DSR 2023 cutting, bending, placing in position and binding all complete
5.22A.6 above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D ormore.
12 12 mm Plastering.
DSR 2023 13.1.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) Sqm 426.53 333.35 1,42,183.78
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
13 15 mm Plastering.
15 mm cement plaster on the rough side of single or half brick
wall of mix : 1:6 (1 cement: 6 fine sand)
14 Marble Flooring
Marble stone flooring with 18 mm thick marble stone, as per
sample of marble approved by Engineer-in-charge, over 20 mm
DSR 2023 (average) thick base of cement mortar 1:4 (1 cement : 4 coarse
11.23.1 sand) laid and jointed with grey cement slurry, including rubbing
and polishing complete with :
Makrana white second quality
15 Anti Skid Flooring
DSR 2023 Glazed Vitrified tiles Matt/Antiskid finish of size
11.41A.3.2 Size of Tile 600 x 1200 mm
16 Tile Skirting
Providing and laying Vitrified tiles in different sizes, with water
absorption less than 0.08% and conforming to IS: 15622, of
approved brand & manufacturer, in all colours and shade, in
DSR 2023 11.47 skirting, riser of steps, laid with cement based high polymer Sqm 15.38 1,893.90 29,124.39
modified quick set tile adhesive (water based) conforming to
IS:15477, in average 6 mm thickness, including grouting of
joints (Payment for grouting of joints to be made separately).
Providing and fixing factory made uPVC glazed/wire mesh
doors comprising of lead free uPVC multi-chambered frame, sash
mullion/coupler (where ever required) extruded profiles having
minimum wall thickness of 1.70 mm for Series R1 and R2 profiles
and 2.10 mm for Series R3 and R4 profiles conforming to EN:
12608 in any shape, colour and design duly reinforced with
galvanized mild steel section made of required shape & size as
per CPWD Specification, uPVC extruded glazing beads, interlocks
and Inline sash adaptor (where ever required) of appropriate
dimension, EPDM gasket, hardware, SS 304 grade fasteners of
minimum 8 mm dia with countersunk head, comprising of
matching polyamide PA6 grade sleeve for fixing frame to finished
wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps
and necessary stainless steel screws etc. Profile of frame, sash &
mullion (if required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed at all corners, including
drilling of holes for fixing hardware and drainage of water etc.
After fixing frame the gap between frame and adjacent finished
wall shall be filled with weather proof silicon sealant over backer
rod of approved size and quality, all complete as per approved
drawing conforming to CPWD specification & direction of Engineer-
in-Charge. Section of steel reinforcement and cross sections of
uPVC profiles to be as per design approved by Engineer-in-
9.147.C2 Fixed window / ventilator with mullion / transom.
9.147.C2.1 Using R1 series with frame (33 mm & above )
x (35 mm & above) & mullion (33 mm & above)
x (50 mm & above). (Height upto 0.90 metre)
Casement window double panels with fixed mullion with S.S.304
friction hinges as per size and weight of sash, multi-point locking
system, zinc alloy (zamak) powder coated handles.
17B 9.147.E2 9.147.E2.1 Using R2 series with frame (39 mm & above) x (39 Sqm 35.28 13,078.70 4,61,416.54 -
mm & above) & sash (39 mm & above) x (60 mm & above) &
mullion (39 mm & above) x (60 mm & above). (Height upto 1.2
17C NDSR Providing & fixing 8mm toughened glass Sqm 37.44 2,475.00 - 92,664.000
18 Solid Flush Door
Providing and fixing ISI marked flush door shutters conforming to
IS : 2202 (Part I) decorative type, core of block board
construction with frame of 1st class hard wood and well matched
DSR 2023 9.20.1 teak 3 ply veneering with vertical grains or cross bands and face Sqm 15.75 3,473.85 54,713.14 -
veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
19 Sal Wood Frame.
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in position
DSR 2023 9.1.2 with hold fast lugs or with dash fasteners of required dia & length Cum 0.24 1,16,520.30 27,790.09 -
(hold fast lugs or dash fastener shall be paid for separately). Sal
Providing and fixing bright finished brass tower bolts (barrel
9.74 type) with
necessary screws etc. complete
Providing and fixing bright finished brass handles with screws etc.
9.81 complete:
Providing and fixing bright finished brass hanging type floor door
stopper with necessary screws, etc. complete.
Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer with IS : 3564, embossed on
9.84 the body, door weight upto 36 kg to 80 kg and door width from each 8.00 ₹ 983.15 7,865.20 -
701 mm to 1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete
Providing and fixing chromium plated brass 100 mm mortice
9.88 latch and lock with 6 levers and a pair of lever handles of each 8.00 ₹ 998.35 7,986.80 -
approved quality with necessary screws etc. complete.
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
Providing and fixing 12 mm thick frameless toughened glass door
shutter of approved brand and manufacture, including providing
and fixing top & bottom pivot & double acting hydraulic floor
21.180 spring type fixing arrangement and making necessary holes etc. Sqm 10.08 5,325.90 53,685.07 -
for fixing required door fittings, all complete as per direction of
Engineer-in-charge (Door handle, lock and stopper etc.to be paid
NDSR Providing and Fixing H-Handle 600mm SS304 Nos 4.00 2,000.00 8,000.000
NDSR Providing and Fixing Patch Lock Nos 4.00 1,500.00 6,000.000
Providing and applying white cement based putty of average
thickness 1mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
22 Weather Coat.
Finishing walls with Acrylic Smooth exterior paint of required
DSR 2023 13.46 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm Sqm 426.53 160.60 68,500.72
over and including priming coat of exterior primer applied @ 0.90
23 Premium Emulsion Paint
Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve
even shade and colour.
13.83.2 Two coats
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound )
13.85.3 With water thinnable cement primer on wall surface
VOC content less than 50 grams/litre
24 DSR 2023 12.45 PLAIN GYPSUM FALSE CEILING
Providing and fixing false ceiling at all heights including providing
and fixing of frame work made of special sections, power pressed
from M.S. sheets and galvanized with zinc coating of 120
gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide 1.6 mm thick with flanges of 27
mm and 37mm, at 1200 mm centre to centre, one flange fixed
to the ceiling with dash fastener 12.5 mm dia x 50 mm long with
6 mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of
required size and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running at the spacing
of 1200 mm centre to centre, to which the ceiling section 0.5
mm thick bottom wedge of 80 mm with tapered flanges of 26
mm each having lips of 10.5 mm, at 450 mm centre to centre, Sqm 202.77 1,355.80 2,74,915.57 -
shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of 2.64 mm dia x 230
mm long G.I. wire at every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having flanges of 20 mm and
30 mm long, the perimeter of ceiling fixed to wall/partition with
the help of rawl plugs at 450 mm centre, with 25 mm long dry
wall screws @ 230 mm interval, including fixing of gypsum board
to ceiling section and perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers covering upto 150
25 S.S Railing.
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
DSR 2023 10.28 stainless steel dash fasteners , stainless steel bolts etc., of Kg. 2300.00 772.40 17,76,520.00
required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
26 Plinth Protection.
Making plinth protection 50 mm thick of cement concrete 1:3:6
(1 cement : 3 coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 20 mm nominal size derived
DSR 2023 4.17 from natural sources) over 75 mm thick bed of dry brick ballast Sqm 31.20 749.30 23,378.16
40 mm nominal size, well rammed and consolidated and grouted
with fine sand, including necessary excavation, levelling &
dressing & finishing the top smooth.
Provding and laying of M20 grade screed concrete over
NS waterproffing layer with maintaing slope as per tech Cum 50.00 8,042.30 -
speecification as per direction of EIC
Structural steel work in single section, fixed with or without connecting plate,
28.1 10.1 including cutting, hoisting, fixing in position and applying a priming coat of Kg 3650.00 117.35 4,28,327.50
approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and
28.2 10.2 framed work, including cutting, hoisting, fixing in position and applying a priming Kg 7650.00 133.70 10,22,805.00
coat of approved steel primer all complete:
Steel work welded in built up sections/ framed work, including cutting, hoisting,
28.3 10.25 fixing in position and applying a priming coat of approved steel primer using -
structural steel etc. as required.
In stringers, treads, landing etc of staircase including use of chequered plate
wherever required all complete
28.3.2 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 6250.00 172.60 10,78,750.00
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)
trusses etc., including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer, including welding and bolted with special shaped
washers etc., complete.
28.4 10.16.1 Hot finished welded type tubes Kg 12534.88 194.40 24,36,781.45
Providing, supplying and fixing galvanized profiled metal deck
sheet of approved thickness and profile, fixed with self-
29 NDSR drilling/self-tapping screws, washers, laps, accessories and Sqft 3438.10 290.00 - 9,97,048.500
necessary supports, complete as per approved specifications and
direction of Engineer-in-Charge.
Providing and laying water proofing treatment to vertical and
surfaces of depressed portions of W.C., kitchen and the like
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with
proofing compound conforming to IS : 2645 in recommended
proportions including rounding off junction of vertical and
horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3
mixed with water proofing compound in recommended proportion
including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied
kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at
PVC sheet should be 100 mm wide and pasted to each other with
Providing and applying two-component Polyurea Hybrid
waterproofing system over prepared surface, including
application of approved primer, silica sand broadcasting as
required, application of Polyurea waterproofing membrane of
specified thickness, treatment of junctions and coving wherever
30A NS required, including necessary preparation and sealing at all Sqm 175.00 2850.00 4,98,750.00
penetrations/grouting locations, and providing and laying
protective geotextile over the waterproofing membrane,
complete in all respects as per the Technical Specifications,
manufacturer’s recommendations and as directed by the
Engineer-in-Charge.
Providing and Fixing of Granite Wash basin counter made of
19mm thick Granite counter-top of approved shade over 12mm
Thick bison board fixed over MS Angle. Rate to include for
200mm granite fascia along the outer perimeter of the counter-
top on 2 sides.The fascia & counter-top shall have R-10 corner
31 NDSR edges along the top and bottom edges as per the drawing. Rate Nos 8.00 10250.00 82,000.00
to include all hardware, MS brackets for support from the
masonry wall, etc complete. Rate to include cutting of counter-
top for accomodating the Washbasin bowl and CP fittings, and
fixing the granite end beading with bull nosing to the cut-
perimeter to neat finish.
Providing and fixing in position mirror of approved make 5.5 mm
thick float glass, of approved quality, including edge polishing,
32 NDSR fixed within black powder-coated metal profile frame, including Nos. 8.00 6250.00 50,000.00
all necessary accessories and fixing hardware, complete in all
respects as per approved design, drawings and direction of
Providing and fixing Roller blinds of approved make, shade,
texture as directed made from high-quality as specified. The
33 NDSR system shall include all mounting brackets, fasteners, Sqm 35.28 3380.00 1,19,246.40
accessories, and fittings, installed complete as per site
requirements and approved drawings.
34 DSR Electrical Works
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FRLS PVC insulated copper conductor single core
cable in surface / recessed medium class PVC conduit, with
1 DSR 2025 1.10.3 modular switch, modular plate, suitable GI box and earthing the Nos. 50.00 1704.00 85,200.00
point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC
insulated copper conductor single core cable in surface/ recessed
2 DSR 2025 1.12 medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR Rmt. 600.00 373.00 223800.00
PVC insulated copper conductor single core cable for loop
earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the
following sizes of FRLS/HFFR PVC insulated copper conductor,
3 DSR 2025 1.14.2 single core cable in surface/ recessed medium class PVC conduit Rmt. 700.00 311.00 217700.00
as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply & Fixing of following sizes of medium class PVC conduit
4 DSR 2025 1.21 along with accessories in surface/recess including cutting the wall
and making good the same in case of recessed conduit as
Supplying & Fixing suitable size GI Box with moduler plate &
5 DSR 2025 1.31 cover infront on surface or in recess including providing & fixing Each 40.00 545.00 21,800.00
3pin 5/6A moduler socket outlet and 5/6 A moduler switch,
connections etc as required
Supplying & Fixing suitable size GI Box with moduler plate &
cover infront on surface or in recess including providing & fixing
6 DSR 2025 1.32 6pin 5/6A & 15/16A moduler socket outlet and 15/16 A moduler Each 40.00 659.00 26,360.00
switch, connections etc as required
Supplying, drawing, Testing and commissioning of
Cat6A UTP 4 pair, 23 AWG solid copper cable in
existing conduit/ on surface, U/FTP, LSZH, Non-
Plenum, Horizontal (solid) Cable suitable for high
speed data networking application supporting upto
10Gbps over a 100 meter channel. The 4 Unshielded
Twisted Pairs (UTP) cable with color coded insulation
7 for easy indentification should have FLAME Rmt. 400.00 74.00 29,600.00
PROPERTIES i.e. Flammability Test - IEC 60332-1,
Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE
802.3an, RoHS. Delay Skew should be < 45NS. The
outer Cable Diameter should be 7.5 + 2 mm. Cable
should have been tested and verified by UL/ ETL etc.
complete as required.
Wiring for group controlled (looped) light point/fan point/exhaust
fan point/ call bell point ( without independent switch etc.) with
1.5 sq. mm FRLS PVC insulated copper conductor single core
8 DSR 2025 1.54.3 cable in surface/ recessed PVC conduit, and earthing the point Nos. 100.00 1246.00 1,24,600.00
with 1.5 sq. mm FRLS PVC insulated copper conductor single
core cable etc. as required. Group C
Providing and fixing GI cable tray of required width and
thickness, including straight lengths, bends, tees, reducers and
accessories, fabricated from pre-galvanized/GI sheet with
perforated as approved. The tray shall be supported on channel
supports suspended ceiling mounted, fixed with approved
clamps, anchor fasteners, nuts and bolts. Item includes cutting,
9 DSR 2025 4.6.4 drilling, joining with couplers, proper alignment and leveling, and Rmt. 50.00 1062.00 53,100.00
routing of electrical cables as required. All metal parts to be
properly treated with anti-rust coating where applicable. Work to
be carried out complete with all materials, labour, tools and
accessories, complete in all respects as per drawings,
specifications and engineer-in-charge’s instructions. size
300mmx50mmx1.6mm
18watt LED Down lighter (COB Type) (System lumen
efficacy ≥120 lm/Watt )
Supplying, Installation, Testing & Commissioning of LED
Recessed/ surface Down lighter (Round / square/ Rectangular)
COB Type of following body material and construction as per IS :
10322 with driver as per the requirement with Driver efficiency
>85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz,
Operating temp range -5 0C to 40 0C, internal surge protection
of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.
F.≥0.95, IP20, CRI >80 , UGR (Unified Glare
Rating) < 19, Flicker free (flicker should be below 5 %), life time
(LED, Driver & electrical circuitry), life time of minimum 50000
10 DSR 2025 8.5.4 Burning Hours with, 70% of initial Lumen maintained till life ends Nos 50.00 1470.00 73500.00
, CCT 3000°K / 4000 K / 5700°K /6500°K (As per ANSI Bin),
SDCM(Standard Deviation Colour
Matching) <3, Maximum power consumption should not more
than the specified rating and Fixture shall be of relevant BIS
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen
printing on housing. OEM must have its own in house NABL lab
all testing facilities for LED fixtures. "complete in all respect i/c
external connections with 1.5 sq mm FRLS/HFFR, PVC insulated
copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy
≥120 <135 lm/Watt output . LM79 & LM80 Test report and all
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
18 watt LED Down lighter (SMD Type) (System lumen
efficacy >135lm/Watt)
Supplying, Installation, Testing & Commissioning of LED
Recessed/surface Down lighter (Round /square/Rectangular)
SMD type of following body material with PMMA and prismatic
construction as per IS : 10322 with driver as per the requirement
with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge
protection of 2.5 KV with Short & Open circuit protection ,THD <
10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <
11 DSR 2025 8.3.4 19, Flicker free, (flicker should be below 5 %), life time (LED, Nos 50.00 1004.00 50200.00
Driver & electrical circuitry), life time of minimum 50000 Burning
Hours with 70% of initial
Lumen maintained till life ends as per LM80 extrapolation IES TM-
21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per
SDCM(Standard Deviation Color Matching) <3, Maximum power
consumption should not more than the specified rating and
Fixture shall be of relevant BIS standard. Manufactures Word
Mark/ Name Engraved/ Embossing/ Screen printing on housing.
complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and
earthing etc. as required with Minimum 5 year OEM warranty.
System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test
Supplying, installation, testing & commissioning of TV point With
Socket complete as required.
Supplying, installation, testing & commissioning of Telephone
point Socket complete as required.
35 Plumbing Works
Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
1 DSR 2023 12.41 with seal ring conforming to IS : 5382, leaving 10 mm gap for Rmt 60.00 248.80 14,928.00
thermal expansion, (i) Single socketed pipes.
12.41.1 75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
2 DSR 2023 12.42 conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal
2c Single tee with door 12.42.3.1 75x75x75 mm Each 4.00 164.20 656.80
2d Single tee with door 12.42.3.2 110x110x110 mm Each 4.00 234.15 936.60
Digitally signed by JAYA
Sl.no. DSR/NDSR Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount NDSR Amount
2e Single tee without door 12.42.4.1 75x75x75 mm Each 4.00 144.30 577.20
2f Single tee without door 12.42.4.2 110x110x110 mm Each 4.00 221.35 885.40
Providing and fixing C.P. brass stop cock (concealed) of standard
and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
thermal stability for hot & cold water supply and all CPVC plain &
4 DSR 2023 18.7 brass
threaded fittings, including fixing the pipe with clamps at 1.00 m
This includes jointing of pipes & fittings with one step CPVC
4a DSR 2023 18.7.2 20 mm nominal dia Pipes Rmt 100.00 335.00 33,500.00
4b DSR 2023 18.7.3 25 mm nominal dia Pipes Rmt 100.00 401.55 40,155.00
Providing and fixing white vitreous china extended wall mounting
closet of size 780x370x690 mm of approved shape including
5 17.78 providing & fixing white vitreous china cistern with dual flush Nos. 4.00 14999.15 59,996.60
fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8
litres), including seat cover, and cistern fittings, nuts, bolts and
gasket etc complete.
Providing and fixing counter top Wash Basin of rectangular shape
6 NDSR all required to complete the work and make it functional. All Nos. 8.00 7750.00 62,000.00
complete as per design and specifications.
Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P. brass) with waste
7 17.5 fitting as per IS : 2556, C.I. trap with outlet grating and other Nos. 4.00 12071.55 48,286.20
couplings in C.P. brass, including painting of fittings and cutting
and making good the walls and floors wherever required : 17.5.1
Single half stall urinal with 5 litre P.V.C. automatic flushing
8 NDSR Supply & fixing of Nahani trap with Stainless Steel jali. Nos. 8.00 450.00 3,600.00
Providing, Installation, testing and commissioning ABS health
9 NDSR faucet unit comprising of CP flxible hose, spary, wall flange etc. Nos. 4.00 1950.00 7,800.00
Providing and fixing CP Brass single lever wall mounted basin
10 NDSR mixer with 150mm extension of premium quality Nos. 4.00 8650.00 34,600.00
Providing and fixing PTMT Waste Coupling for wash basin and
11 17.69 sink, of approved quality and colour. Nos. 8.00 115.30 922.40
Waste coupling 31 mm dia of 79 mm length and 62 mm
breadthweighing not less than 45 gms
Providing and fixing PTMT towel rail complete with brackets fixed
to wooden cleats with CP brass screws with concealed fittings
12 17.73 arrangement of approved quality and colour. 17.73.2 600 mm Nos. 4.00 708.95 2,835.80
long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 gms.
13 NDSR Providing and fixing in position Robe hook complete Nos. 8.00 650.00 5,200.00
Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200mm wide with minimum distances of 37 mm from wall
14 17.72 face with concealed fittings arrangement of approved quality and Nos. 4.00 231.95 927.80
colour, weighing not less than 88 gms.
Providing and fixing PTMT liquid soap container 109 mm wide,
15 17.71 high and 112 mm distance from wall of standard shape with Nos. 4.00 168.35 673.40
bracket of the same materials with snap fittings of approved
quality and colour, weighing not less than 105 gms.
Providing and fixing in position Toilet paper holder complete of
approved of make CP Brass
Providing and fixing PTMT soap Dish Holder having length of 138
17 18.65 breadth 102 mm, height of 75 mm with concealed fitting Nos. 4.00 111.45 445.80
weighing not less than 106 gms.
Providing and fixing CP Brass 32mm size Bottle Trap of approved
18 17.22A quality & make and as per the direction of Engineerin-charge. Nos. 8.00 1034.80 8,278.40
Providing and fixing C.P. brass angle valve for basin mixer and
19 18.53.1 geyser points of approved quality conforming to IS:8931 : 15mm Nos. 8.00 574.30 4,594.40
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
Indoor & Outdoor Renovation
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Indoor Renovation
1 Fly Ash bricks Masonary (1:6) (Superstructure).
Brick work with clay flyash F.P.S. (non modular) brick of class
DSR 2023 designation 7.5 in superstructure above plinth level up to floor
6.32.2 five level in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland
Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including
DSR 2023 pumping of concrete to site of laying, curing, carriage for all
5.33 leads; but excluding the cost of centering, shuttering, finishing
and reinforcement as per direction of the engineer-in-charge, for
the following grades of concrete.:
Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
d) Column in Super - Structure :- Cum 1.944 9,860.40 19,168.62
3 Reinforcement.
Steel reinforcement for R.C.C. work ready to use “cut and bend”
rebars of approved make from factory/workshop to construction
DSR 2023 site including placing in position and binding all complete upto
5.22B.1 plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or
4 12 mm Plastering.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) Sqm 251.050 333.35 83,687.52
5 15 mm Plastering.
DSR 2023 15 mm cement plaster on the rough side of single or half brick
13.2.2 wall of mix : 1:6 (1 cement: 6 fine sand)
6 Cement Concrete Flooring.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of nosing Sqm 140.000 614.20 85,988.00
of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
7 Anti Skid Flooring
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 1200 mm
8 Italian Flooring
Providing and laying machine cut, mirror polished Marble stone
in required design (Simple geometrical, abstract etc.) and in
combination with Italian marble stones of different colours,
finished surface texture etc., in linear portions of the building, all
complete as per the architectural drawings, with 18 mm thick
11.52 stone slab laid over 20 mm (average) thick base of cement Sqm 220.000 6,927.35 15,24,017.00 -
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with
white cement slurry @ 4.4 kg/sqm, including pointing with white
cement slurry admixed with pigment to match the marble shade,
including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge.
11.52.1 18 mm thick Italian Marble stone slab, Perlato, Rosso
Fire Red or Dark Emperadore etc.
9 Tile Skirting
Providing and laying Vitrified tiles in different sizes, with water
absorption less than 0.08% and conforming to IS: 15622, of
approved brand & manufacturer, in all colours and shade, in
skirting, riser of steps, laid with cement based high polymer Sqm 50.000 1,893.90 94,695.00
modified quick set tile adhesive (water based) conforming to
IS:15477, in average 6 mm thickness, including grouting of
joints (Payment for grouting of joints to be made separately).
Providing and laying 18 mm thk machine cut & machine polished
Granite door frame on toilet area a prefinished surface with 1:3
10 NDSR cement sand mortar. Rate shall be inclusive of machine polishing Rmt. 60.000 2,500.00 - 1,50,000.00
edges and four side edge chamfering in case of protruding edges
& groove if ordered. complete as per drawings and site
11 NDSR Italian Washbasin Counter
Providing & fixing washbasin counter made of ms angle frame
with bison board finish with italian 18-20mm thick.
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing and laying water proofing treatment to vertical and
surfaces of depressed portions of W.C., kitchen and the like
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with
proofing compound conforming to IS : 2645 in recommended
proportions including rounding off junction of vertical and
horizontal surface.
DSR 2023, (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3
mixed with water proofing compound in recommended proportion
including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied
kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at
PVC sheet should be 100 mm wide and pasted to each other with
bitumen @ 1.7 kg/sqm).
13 Solid Flush Door
Providing and fixing ISI marked flush door shutters conforming to
IS : 2202 (Part I) decorative type, core of block board
construction with frame of 1st class hard wood and well matched
teak 3 ply veneering with vertical grains or cross bands and face Sqm 50.000 3473.85 1,73,692.50 -
veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
14 Sal Wood Frame.
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in position
with hold fast lugs or with dash fasteners of required dia & length Cum 1.000 1,16,520.30 1,16,520.30 -
(hold fast lugs or dash fastener shall be paid for separately). Sal
Providing and fixing bright finished brass tower bolts (barrel
9.74 type) with
necessary screws etc. complete
Providing and fixing bright finished brass handles with screws etc.
9.81 complete:
Providing and fixing bright finished brass hanging type floor door
stopper with necessary screws, etc. complete.
Providing and fixing aluminium extruded section body tubular
type universal hydraulic door closer with IS : 3564, embossed on
9.84 the body, door weight upto 36 kg to 80 kg and door width from each 25 ₹ 983.15 24,578.75 -
701 mm to 1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete
Providing and fixing chromium plated brass 100 mm mortice
9.88 latch and lock with 6 levers and a pair of lever handles of each 25 ₹ 998.35 24,958.75 -
approved quality with necessary screws etc. complete.
15 Cubicle Partition
Providing & Fixing of Modular Toilet Cubicals of approved size
made up of 12 mm thk HPL(High Pressure Laminate)Board
NDSR assembled with all modular/modern Hardware with adjustable Nos 4.000 29,500.00 1,18,000.00
s.s/Nylon legs finished with door of same material of size 600
mm(W)x1715 mm(H) & as per manufacturer specifications.
16 M.S. Grill.
Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc. including
priming coat with approved steel primer all complete. Kg 150.000 238.35 35,752.50
Fixed to openings /wooden frames with rawl plugs screws
17 Cement Primer.
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound)
With water thinnable cement primer on wall surface having OC
content less than 50 grams/litre
18 Weather Coat.
Finishing walls with Acrylic Smooth exterior paint of required
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm Sqm 151.050 160.60 24,258.63
over and including priming coat of exterior primer applied @ 0.90
19 Plastic Emulsion
Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
DSR 2023 than 50 grams/ litre of approved brand and manufacture,
13.83 including applying additional coats wherever required to achieve
even shade and colour.
13.83.2 Two coats
Providing and applying white cement based putty of average
DSR 2023 thickness 1mm, of approved brand and manufacturer, over the
13.80 plastered wall surface to prepare the surface even and smooth
Providing and applying plaster of paris punning in average 8 to
12 mm thickness on walls and columns to bring the surface in
21 NDSR plumb line and level. Item to be completed in all respects Sqm 100.000 450.00 45,000.00
including scrapping of existing neeru surface, cleaning etc. as per
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
38 mm thick wood block flooring of first class teak wood laid over
25 mm thick leveling layer of cement concrete 1:2:4 (1 cement :
2 coarse sand: 4 graded stone aggregate 10 mm nominal size)
DSR 2023 to be paid separately, coated with a thin layer of hot bitumen
11.34 penetration 80/25 (blown type) @ 2.45 kg per sqm, including
fixing blocks in position after dipping in
hot bitumen (blown type) up to half depth, planed, levelled
smooth and finished complete.(Stage)
Prividing & fixing Vinyl anti static 2-3mm thick of approved
23 NDSR colour, shade inluding adhesive with surface preparation etc Sqm 25.000 1,850.00 46,250.00
complete all respect.(Electrical Panel Room)
Prividing & fixing Vinyl flooring 5mm thick of approved colour,
24 NDSR shade inluding adhesive with surface preparation etc complete all Sqm 102.266 3,200.00 3,27,250.00
respect.(Back Stage with corridor)
Supply, Installation, Testing and Commissioning of High-
Resolution Large Format LED Video Wall/LED Display System of
25 NDSR min. 20 ft x 10 ft for Stage Background Including Supporting each 1.000 28,50,000.00 28,50,000.00
Structural Framework, Control System, Power Supply
Arrangement, and Allied Works Complete.
Auditorium Writing pad Chair Theatre Pushback Chair
Product Type-Push Back
Material-Fire rated velvet upholstery
26 NDSR Back Angle-Adjustable Nos 276.000 19,500.00 53,82,000.00
Seating Capacity-1 Person
Design Type-Standard
Size-23inch, Premium Quality
Chesterfield Sofa
Frame material-Natural Wooden framing
Seat Material-Fire rated Velvet seat
Primary Color-Red Wine, Deep Purple
27 NDSR Usage/Application-Auditorium Nos 14.000 30,500.00 4,27,000.00
Size/ Dimensions (LxW)-34"D x 76"W x 35"H
Cushion Included-No
Appearance-Modern and Premium Quality
VVIP Portable Sofa
Frame material-Natural Wooden framing
Seat Material-Fire rated Velvet seat
Primary Color-Red Wine, Deep Purple
28 NDSR Usage/Application-Auditorium Nos 10.000 30,500.00 3,05,000.00
Size/ Dimensions (LxW)-34"D x 76"W x 35"H
Cushion Included-No
Appearance-Modern , Premium Quality
Providing & Supplying Chairs with fabric upholstery.(Changing
Providing & Fixing Table made of 19mm ply finished with
approved 1mm thick laminate etc complete.(Changing Room)
Providing and fixing locker storage unit of size 4’-0”(1200mm)
width × 450mm depth × 2100mm height (or as per drawing).
Carcass: Made of 18mm BWR grade plywood / pre-laminated
MDF / particle board, finished with laminate inside and outside;
internal finish with white laminate and exposed edges sealed with
1mm thick PVC edge banding. Shutters: 18mm thick board
shutters, externally finished with 1.0mm decorative laminate
(approved shade) and internally with white laminate. Each
shutter fitted with soft-closing concealed hinges (Hettich / Hafele
/ Ebco equivalent).
Compartments: Designed as locker-type divisions, each with
individual locking system (cam lock / pad lock arrangement).
Handles: SS finish / aluminum profile handles or cutout pull-type,
as approved.(Changing Room)
Providing and placing bench of size as per drawing 1200mm
length × 450mm depth × 450mm height). Structure: Frame
made of seasoned hardwood Top made of 25mm thick solid wood
plank / laminated board with edge moulding, finished with
Laminate. Legs / base: Hardwood members frame with level
adjusters.(Changing Room)
Providing & making Vanity Counter made of 19mm bwp plywood
finished in laminate as per approved drawings & specifications
Providing & Supplying Wooden Chairs with fabric upholstery.(VIP
Providing & Fixing 3 seater sofa with fabric upholstery.(VIP
Providing & Fixing 2 seater sofa with fabric upholstery.(VIP
Providing & Fixing Centre Table made of MS Frame with
approved Italian Stone etc complete.(VIP Lounge)
Providing & Fixing Side Table made of MS Frame with approved
Italian Stone etc complete.(VIP Lounge)
Providing and Fixing Vinyl Mural Graphics/Artwork on Identified
39 NDSR Wall Surfaces for Urban Beautification and Public Space Sqm 800.000 4,250.00 - 34,00,000.00
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing and fixing aluminium framework in 600 x 600 mm grid
system using approved aluminium sections fixed from wall with
suitable hangers and fasteners, including perimeter L-angle
1 NDSR support, providing and placing 50 mm thick 24 kg/m³ density Sqm 350.000 3,450.00 - 12,07,500.00
glass wool insulation wrapped with tissue paper and secured with
GI chicken mesh of approved gauge, including all accessories,
scaffolding, cutting, wastage, labour, T&P and making complete
as per approved drawings and direction of Engineer-in-Charge.
Providing and fixing approved make channelled/perforated
wooden acoustic wall panelling having NRC 0.60 comprising 15
mm thick, 192 mm wide and 2400 mm long moisture resistant
MDF/Fibre board substrate with decorative laminated finish on
exposed face in approved shade and melamine balancing layer
on the reverse side. The panel shall have specially designed
acoustic perforation/channel pattern comprising 3 mm wide
grooves with 13 mm visible panel surface or equivalent approved
configuration to achieve required acoustic performance. The
reverse face of panel shall be provided with factory bonded
acoustical non-woven fleece/Soundtex backing to achieve Noise
Reduction Coefficient (NRC) of 0.60 tested as per ASTM C423.
2 NDSR The panelling shall have tongue and groove edge profile for Sqm 380.000 4,550.00 - 17,29,000.00
seamless appearance and fixing through concealed clips over
approved make extruded aluminium keel/grid system of size
3000 mm (L) × 24 mm (H) × 15.5 mm (W) or equivalent, fixed
to wall with necessary aluminium splines, cleats, anchor
fasteners, screws and accessories complete. The system shall be
suitable for relative humidity resistance up to 70% RH with
permissible camber less than 1 mm/1000 mm and bow less than
The work shall include all materials, labour, scaffolding, cutting,
wastage, fittings, fixtures and making complete in all respects as
per approved drawings, manufacturer’s specifications and
direction of Engineer-in-Charge.
Providing and fixing 9 mm thick Acoustic PET panel of approved
make, texture and shade on wall surface, backed with 12 mm
thick BWR/BWP grade plywood fixed to wall framework/substrate
with necessary screws, fasteners and approved adhesive
complete. The acoustic PET panel shall be fixed over plywood
backing using approved high-strength adhesive including
necessary cutting, edge finishing, groove alignment, levelling and
making openings for electrical points/services wherever required.
The work shall include all materials, labour, adhesive, fixing
accessories, edge trims (if required), scaffolding, T&P, wastage
and finishing complete in all respects as per approved design,
drawings and direction of Engineer-in-Charge.
FABRICATION WORK
1 NDSR MS SPEAKER PLATFORM SUPPORTING FROM WALL Sqm 16.000 6,500.00 - 1,04,000.00
Providing & fixing M.S speaker platform in M.S angle 75x 75 mm
as per drawing with 2 layers of 19mm thk ply & fixing 19mm thk
rigid rubber on ply complete with fabrication, levelling etc.
complete including one coat of Red oxide paint and two coat of
Black paint as approved M.S. angle will be supported at 1200mm
c/c, the depth of the platform will be as per site condition
FIRST CEILING IN GLASSWOOL & CHICKEN MESH.
Providing and fixing of G.I frame work of Gypsum India with
Intermediate channel of 45 x 15 x 0.8 mm thk @ 900 c/c in one
Direction & ceiling section of 80 x 26 x 0.5 mm @ 450 c/c in
other direction as per specification of company include perimeter
channel with 50 mm thk 32kg/m3 density glasswool + Black RP
tissue paper. Entire frame/glasswool shall be covered with
chicken mesh of G.I 19 x19 mm square of 14 guage (as per
approved sample) including Micron tissue paper,machine screw &
levelling etc by instruction of site engineer.
2 PLAIN GYPSUM FALSE CEILING Sqm 460.000 1,355.80 6,23,668.00
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing and fixing false ceiling at all heights including providing
and fixing of frame work made of special sections, power pressed
from M.S. sheets and galvanized with zinc coating of 120
gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide 1.6 mm thick with flanges of 27
mm and 37mm, at 1200 mm centre to centre, one flange fixed
to the ceiling with dash fastener 12.5 mm dia x 50 mm long with
6 mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of
required size and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running at the spacing
of 1200 mm centre to centre, to which the ceiling section 0.5
mm thick bottom wedge of 80 mm with tapered flanges of 26
mm each having lips of 10.5 mm, at 450 mm centre to centre,
shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of 2.64 mm dia x 230
mm long G.I. wire at every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having flanges of 20 mm and
30 mm long, the perimeter of ceiling fixed to wall/partition with
the help of rawl plugs at 450 mm centre, with 25 mm long dry
wall screws @ 230 mm interval, including fixing of gypsum board
to ceiling section and perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound , jointing tapes ,
finishing with jointing compound in 3 layers covering upto 150
3 NDSR ROCKFON TILE CEILING OR ECOPHON TILE CEILING Sqm 245.000 2,850.00 6,98,250.00
Providing & Installing of the Rockfon 600 x 1200mm x 15mm thk
0.95NRC value tiles with connected grid system of Rockfon
weighing 3kg/m3.The tiles shall be Black matt with the Black
glass tissue paper,including cutting of spot light,AC diffuser,
return air grill, Sprinkler & other related services & providing
necessary 6 mm thk ply support & redoing the same in good
finish etc complete.
Providing and fixing tiled false ceiling of specified materials of
595x595 mm in true horizontal level, suspended on inter locking
metal grid of hot dipped galvanized steel sections ( galvanized @
120 grams/ sqm, both side inclusive) consisting of main “T”
runner with suitably spaced joints to get required length and of
size 24x38 mm made from 0.30 mm thick (minimum) sheet,
spaced at 1200 mm center to center and cross “T” of size 24x25
mm made of 0.30 mm thick (minimum) sheet, 1200mm long
spaced between main “T” at 600 mm center to center to form a
grid of 1200x600 mm and secondary cross “T” of length 600 mm
and size 24x25 mm made of 0.30 mm thick (minimum) sheet to
be interlocked at middle of the 1200x600 mm panel to form
grids of 600x600 mm and wall angle of size 24x24x0.3 mm and
laying false ceiling tiles of approved texture in the grid including,
required cutting/making, opening for services like diffusers, grills,
light fittings, fixtures, smoke detectors etc. Main “T” runners to
be suspended from ceiling using GI slotted cleats of size 27 x 37
x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long
dash fasteners, 4 mm GI adjustable rods with galvanised
butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm
center to center along main T, bottom exposed width of 24 mm
of all T-sections shall be pre-painted with polyester paint, all
complete for all heights as per specifications, drawings and as
directed by Engineer-in-charge.
12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global
CARPET FLOORING, EDGE NOSING, SKIRTING
Providing and fixing approved quality carpet flooring with foam
1 NDSR backing/PU foam underlay including adhesive fixing, edge sqm 330.000 3,500.00 - 11,55,000.00
trimming, finishing complete as directed by Engineer-in-Charge.
P/F 75x50mm ply nosing in 12mm thick MR ply on intermediate
2 NDSR steps anchored firmly to provide base for fixing step lights on Rmt 220.000 550.00 - 1,21,000.00
existing racks complete as required
Providing, supplying & fixing powder coated aluminium edge
3 NDSR nosing profile with/ without inbuilt LED lighting system for Rmt 220.000 1,450.00 3,19,000.00
auditorium/step illumination complete with all respects.
Providing and fixing aluminium transition profile between carpet
and inside door frame complete as required as per specification.
Providing and fixing skirting of 100mm height made out of 12
mm thick BWR plywood backing, finished with 1.0 mm thick
approved laminate on exposed surface, including necessary
5 NDSR adhesive, screws, nails, edge finishing, polishing of exposed Rmt 300.000 725.00 - 2,17,500.00
edges, cutting, fitting, making grooves wherever required and
fixing in position complete as per approved design complete in all
Providing & Fixing 10mm toughened glass 600mmx900mm urinal
1 NDSR partition with froasted film and fixed to wall including necessary Nos 7.00 5,500.00 38,500.00
fitting etc complete
Providing and fixing in position mirror of approved make 5.5 mm
thick float glass, of approved quality, including edge polishing,
fixed within black powder-coated metal profile frame, complete
2 NDSR with integrated backlit LED lighting system, including all Nos. 14.00 7750.00 1,08,500.00
necessary accessories and fixing hardware, complete in all
respects as per approved design, drawings, and Architect’s
specifications.
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing & Fixing Full height mirror 5.5mm for changing room
with ply backing support etc complete with all respect
Providing and fixing Single glazed partitions of 10mm thick
toughened glass as per Drawings using Full Height glass partition
systems of approved equivalent and shall be able to provide a
sound reduction of 36 dB. The glass panels shall be supported by
3 NDSR Aluminium WCP Profiles of 25x45mm on all 4 sides of the Glass Smt. 93.50 6000.00 5,61,000.00
partition perimeter. Glass-to-glass butt joints shall be done using
Aluminium ' I ' profile of 5x11mm, and corner glass junctions to
have 90° corner Aluminium profile. At Glassperpendicular 'T'
junctions, Aluminium T-junction profile to be used.Finishes of all
Providing and fixing 12 mm thick frameless toughened glass door
shutter of approved brand and manufacture, including providing
and fixing top & bottom pivot & double acting hydraulic floor
21.180 spring type fixing arrangement and making necessary holes etc. Sqm 15.000 5,325.90 79,888.50 -
for fixing required door fittings, all complete as per direction of
Engineer-in-charge (Door handle, lock and stopper etc.to be paid
NDSR Providing and Fixing heavy duty Hydraulic floor spring Nos 6.00 8,500.00 51,000.000
NDSR Providing and Fixing H-Handle 800mm SS304 Nos 6.00 2,250.00 13,500.000
NDSR Providing and Fixing Patch Lock Nos 6.00 1,500.00 9,000.000
Providing and fixing port hole framework with 19mm thick ply
frame. The edges to be finished with the wooden beading and ply
5 NDSR to clad with 1mm thick black laminate. Work to be done as per Nos 2.00 4,500.00 9,000.00
instructions from site in-charge. Size of port hole- 600mm x
P/F trap doors of overall size 600x600 in ceiling, made out of
wooden frame work screwed to existing ceiling G.I. framework,
6 NDSR shutters made out of 12mm thick MDF and finished with 1.0mm Nos 10.00 3,500.00 35,000.00
thick laminate including necessary hardware, adhesive etc.
complete as per detailed drawings.
Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
DSR 2023 with seal ring conforming to IS : 5382, leaving 10 mm gap for
12.41 thermal expansion, (i) Single socketed pipes.
12.41.1 75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded
DSR 2023 fittings/ accessories for unplasticised Rigid PVC rain water pipes
2 conforming to IS : 13592 Type A, including jointing with seal ring 0.00
conforming to IS : 5382, leaving 10 mm gap for thermal
2c Single tee with door 12.42.3.1 75x75x75 mm Each 7.00 164.20 1,149.40
2d Single tee with door 12.42.3.2 110x110x110 mm Each 7.00 234.15 1,639.05
2e Single tee without door 12.42.4.1 75x75x75 mm Each 7.00 144.30 1,010.10
2f Single tee without door 12.42.4.2 110x110x110 mm Each 7.00 221.35 1,549.45
Providing and fixing C.P. brass stop cock (concealed) of standard
DSR 2023 design
18.52 and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
thermal stability for hot & cold water supply and all CPVC plain &
threaded fittings, including fixing the pipe with clamps at 1.00 m
This includes jointing of pipes & fittings with one step CPVC
4a 20 mm nominal dia Pipes Rmt 140.00 335.00 46,900.00
4b 25 mm nominal dia Pipes Rmt 140.00 401.55 56,217.00
Providing and fixing white vitreous china extended wall mounting
closet of size 780x370x690 mm of approved shape including
5 17.78 providing & fixing white vitreous china cistern with dual flush Nos. 10.00 14999.15 1,49,991.50
fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8
litres), including seat cover, and cistern fittings, nuts, bolts and
gasket etc complete.
Providing and fixing counter top Wash Basin of rectangular shape
6 NDSR all required to complete the work and make it functional. All Nos. 26.00 7750.00 2,01,500.00
complete as per design and specifications.
Supply and installation of Thermostatic Control Face Plate as per
7 NDSR approved make, all connectors and accessories asrequired etc. Nos. 4.00 13425.00 53,700.00
Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P. brass) with waste
7 17.5 fitting as per IS : 2556, C.I. trap with outlet grating and other Nos. 9.00 12071.55 1,08,643.95
couplings in C.P. brass, including painting of fittings and cutting
and making good the walls and floors wherever required : 17.5.1
Single half stall urinal with 5 litre P.V.C. automatic flushing
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
8 NDSR Supply & fixing of Nahani trap with Stainless Steel jali. Nos. 34.00 650.00 22,100.00
Providing, Installation, testing and commissioning ABS health
9 NDSR faucet unit comprising of CP flxible hose, spary, wall flange etc. Nos. 10.00 2550.00 25,500.00
complete of make (Jaquar model No. ALD-CHR-573)
Providing and fixing CP Brass single lever wall mounted basin
mixer with 150mm extension of quality & make
Providing and fixing PTMT Waste Coupling for wash basin and
11 17.69 approved quality and colour. Nos. 22.00 115.30 2,536.60
17.69.1 Waste coupling 31 mm dia of 79 mm length and 62 mm
weighing not less than 45 gms
Providing and fixing PTMT towel rail complete with brackets fixed
to wooden cleats with CP brass screws with concealed fittings
12 17.73 arrangement of approved quality and colour. 17.73.2 600 mm Nos. 9.00 708.95 6,380.55
long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing in position Robe hook complete of approved
Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200mm wide with minimum distances of 37 mm from wall
14 17.72 face with concealed fittings arrangement of approved quality and Nos. 9.00 231.95 2,087.55
colour, weighing not less than 88 gms.
Providing and fixing PTMT liquid soap container 109 mm wide,
15 17.71 high and 112 mm distance from wall of standard shape with Nos. 9.00 168.35 1,515.15
bracket of the same materials with snap fittings of approved
quality and colour, weighing not less than 105 gms.
Providing and fixing in position Toilet paper holder complete of
approved of make CP Brass
Providing and fixing PTMT soap Dish Holder having length of 138
17 18.65 breadth 102 mm, height of 75 mm with concealed fitting Nos. 9.00 111.45 1003.05
weighing not less than 106 gms.
Providing and fixing CP Brass 32mm size Bottle Trap of approved
18 17.22A quality & make and as per the direction of Engineerin-charge. Nos. 22.00 1034.80 22,765.60
Providing and fixing C.P. brass angle valve for basin mixer and
19 18.53.1 geyser points of approved quality conforming to IS:8931 : 15mm Nos. 22.00 574.30 12,634.60
Antitermite Treatment.
Treatment of soil under existing floors using chemical emulsion @
one litre per hole, 300 mm apart including drilling 12 mm
20 diameter holes and plugging with cement mortar 1 :2 (1 cement Sqm 950.000 310.05 2,94,547.50
: 2 Coarse sand) to match the existing floor: With
Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying, Installation, Testing and Commissioning (SITC) of
Hydraulic Passenger Lift of approved make for G+1 floors (02
stops / 02 landings) having capacity of 13 passengers with
automatic centre opening/telescopic doors, operating speed of
0.3 m/s, complete with hydraulic power pack unit, guide rails, lift
machine, controller, cabin, landing doors, car operating panel,
landing operating panel, safety devices and all accessories
required for smooth and safe operation.
The lift shall comprise aesthetically finished stainless steel/MS
powder coated cabin with anti-skid flooring, LED lighting,
handrail, automatic rescue device (ARD), overload indicator,
emergency alarm, intercom, door safety sensor, emergency stop
switch, limit switches, buffers, guide shoes, hydraulic
jack/cylinder, controller panel, wiring, earthing and all associated
accessories complete.
The system shall operate on single phase power supply and shall
be complete in all respects including necessary structural
supports, brackets, grouting, commissioning, statutory approvals,
testing, warranty and handing over as per approved
specifications and direction of Engineer-in-Charge.
Type: Hydraulic Lift
Stops: G+1 (02 Stops)
Door Type: Automatic
Power Supply: Single Phase
Dismantling and removing existing wall panelling including
careful dismantling, stacking of serviceable materials (if
required), disposal/removal of unserviceable materials, debris
22 NDSR and malba from site to approved dumping location, complete Sqm 432.00 190.00 82,080.00
with all labour, tools & plants, loading, unloading, lead and lift,
and making good disturbed surfaces as directed by the Engineer-
Demolishing cement concrete manually/ by mechanical means
including disposal of material within 50 metres lead as per
23 15.2 direction of Engineer - in - charge. cum 20 2434.25 48,685.00
15.2.1 Nominal concrete 1:3:6 or richer mix (including
equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means
24 15.3 stacking of steel bars and disposal of unserviceable material cum 10 3551.25 35,512.50
metres lead as per direction of Engineer - in- charge.
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and disposal of unserviceable
within 50 metres lead as per direction of Engineer-in-charge. In
Dismantling doors, windows and clerestory windows (steel or
26 15.12 shutter including chowkhats, architrave, holdfasts etc. complete
stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below Each 25.00 367.20 9,180.00
15.12.2 Of area beyond 3 sq. metres Each 5.00 502.75 2,513.75
Dismantling tile work in floors and roofs laid in cement mortar
stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm
Dismantling old plaster or skirting raking out joints and cleaning
28 15.56 surface for plaster including disposal of rubbish to the dumping Sqm 100.00 54.65 5,465.00
within 50 metres lead.
Removing dry or oil bound distemper, water proofing cement
29 13.91 the like by scrapping, sand papering and preparing the surface Sqm 1500.00 25.15 37,725.00
including necessary repairs to scratches etc. complete.
Structural steel work riveted, bolted or welded in built up
sections, trusses
30 DSR 10.2 and framed work, including cutting, hoisting, fixing in position Kgs 3000.000 133.70 4,01,100.00
and applying a priming coat of approved steel primer all
Providing & fixing M12 Chemical fastener with hole making &
drilling complete with all respects
Painting with synthetic enamel paint of approved brand and
DSR 2023 manufacture of required colour to give an even shade : Two or
13.62.1 more coats on new work over an under coat of suitable shade
with ordinary paint of approved brand and manufacture
Outdoor Renovation
Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains (not
DSR 2023 exceeding 1.5 m in width or 10 sqm on plan), including dressing
2.8 of sides and ramming of bottoms, for all lift, including getting out
the excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.
a. All kinds of Soil Cum 40.42 260.30 10,521.90
2 Back Filling.
Filling available excavated earth (excluding rock) in trenches,
DSR 2023 plinth, sides of foundations etc. in layers not exceeding 20cm in
2.25 depth, consolidating each deposited layer by ramming and
watering, lead up to 50 and for all lift.
Supplying and stacking of good earth at site including royalty and
2a carriage upto 5 km lead complete (earth measured in stacks will cum 30.00 803.75 24,112.50
be reduced by 20% for payment).
3 Sand Filling.
DSR 2023 Supplying and filling in plinth with sand under floors, including
2.27 watering, ramming, consolidating and dressing complete.
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 40 mm nominal size derived Cum 25.000 7,178.75 1,79,468.75
from natural sources)
5 Burnt Clay bricks Masonry (1:6) (in F & P).
Brick work with common burnt clay machine moulded perforated
modular bricks of class designation 12.5 conforming to IS : 2222
DSR 2023 in exposed brick work including making horizontal and vertical
6.31.1 grooves 10 mm wide 12 mm deep complete in cement mortar
1:6 (1 cement : 6 coarse sand).
From ground level upto plinth level
6 Fly Ash bricks Masonry (1:6) (Superstructure).
Brick work with clay flyash F.P.S. (non modular) brick of class
DSR 2023 designation 7.5 in superstructure above plinth level up to floor
6.32.2 five level in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
7 Fly Ash Half bricks Masonry (1:4) (Superstructure).
Half brick masonry with common burnt clay F.P.S. (non modular)
DSR 2023 bricks of class designation 7.5 in superstructure above plinth
6.13.2 level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland
Slag cement, admixtures in recommended proportions as per IS:
9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including
DSR 2023 pumping of concrete to site of laying, curing, carriage for all
5.33 leads; but excluding the cost of centering, shuttering, finishing
and reinforcement as per direction of the engineer-in-charge, for
the following grades of concrete.:
Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
a) Footing,column & Beam Cum 20.000 9,504.75 1,90,095.00
b) Lintel, Roof slab Cum 20.000 9,860.40 1,97,208.00
9 Reinforcement.
Steel reinforcement for R.C.C. work including straightening,
DSR 2023 cutting, bending, placing in position and binding all complete
5.22.6 upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
10 12 mm Plastering.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) Sqm 150.000 333.35 50,002.50
11 15 mm Plastering.
DSR 2023 15 mm cement plaster on the rough side of single or half brick
13.2.2 wall of mix : 1:6 (1 cement: 6 fine sand)
12 Marble Flooring
Marble stone flooring with 18 mm thick marble stone, as per
sample of marble approved by Engineer-in-charge, over 20 mm
DSR 2023 (average) thick base of cement mortar 1:4 (1 cement : 4 coarse
11.23.1 sand) laid and jointed with grey cement slurry, including rubbing
and polishing complete with :
Makrana white second quality
13 Centering and Shuttering
Centering and shuttering including strutting, propping etc. and
of form work for :
4.3.1 Foundations, footings, bases for columns Sqm 30.000 392.15 11,764.50
Retaining walls, return walls, walls (any thickness)
4.3.2 including attached pilasters, buttresses, plinth and string Sqm 10.000 842.50 8,425.00
courses fillets, kerbs and steps etc.
4.3.3 Columns, piers, abutments, pillars, posts and struts Sqm 30.000 961.30 28,839.00
14 Granite Flooring
Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of
the building all complete as per the architectural drawings with
18 mm thick stone slab over 20 mm (average) thick base of
cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed
with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge.
Polished Granite stone slab of colour Black, Cherry/Ruby
Red or equivalent
14a Granite Cladding
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20
mm thick base cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement,mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding and
polishing of edges to give high gloss finish etc. complete at all
DSR 2023 Granite stone slab of colour black, Cherry/Ruby red
8.2.2 8.2.2.1 Area of slab upto 0.50 sqm
15 Decorative Architectural Work
Providing and applying decorative architectural treatment to
external façade, comprising moulded/corniced bands, decorative
pilasters/ columns, architraves etc. in cement mortar as per
NDSR approved architectural design, including necessary scaffolding, Sqm 155.000 3,250.00 - 5,03,750.00
surface preparation, fixing, joints, neat finishing and two coats of
exterior-grade paint, complete as directed by Engineer-in-
Providing and applying white cement based putty of average
DSR 2023 thickness 1mm, of approved brand and manufacturer, over the
13.80 plastered wall surface to prepare the surface even and smooth
17 Weather Coat.
Finishing walls with Acrylic Smooth exterior paint of required
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm Sqm 200.000 160.60 32,120.00
over and including priming coat of exterior primer applied @ 0.90
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Providing and fixing 20-25 mm thick machine-cut, approved-
quality natural sandstone cladding on the external facade at all
height levels. The scope of work includes preparing the backing
surface, applying backing mortar (typically cement-sand mix),
using stainless steel (SS-304 grade) cramps for dry or semi-dry
18 NDSR mechanical anchoring, precise cutting, dressing, specialized Sqm 50.000 8,500.00 4,25,000.00
carving, mouldings, and architectural grooves as per design. The
rate must also include staging, heavy-duty scaffolding, structural
jointing with approved weather-resistant sealants/grouts, surface
cleaning, and finishing complete in all respects as per the
approved architectural drawings and design based report.
Providing, fabricating, and fixing Glass Fiber Reinforced Concrete
(GRC / GFRC) Architectural Elements including decorative
cornices, brackets, architraves, pediments, column capitals, and
bases of approved design and profile. The elements shall be
manufactured using AR (Alkali Resistant) glass fibers, high-grade
Portland cement (Grade 53), and premium aggregates,
maintaining a uniform thickness of 12mm to 15mm. Installation
must be done strictly in true line and level using structural GI/MS
brackets, anchors, and stainless steel fasteners fixed to the
RCC/brickwork. Structural joints between components are to be
filled with non-shrink grout and finished seamlessly with weather-
grade acrylic sealant. The rate shall include material cost,
fabrication mold setup, safe lifting, scaffolding at all heights,
installation hardware, tools, tackles, and finishing ready for
painting, complete as per architectural drawings and instructions
of the Engineer-in-charge.
a. NDSR GRC Decorative Cornice (6" to 12" projection) Rmt 80.000 2,300.00 1,84,000.00
b. NDSR Ornate Column Capitals (Pillar Top Wraps) Nos 20.000 15,500.00 3,10,000.00
Providing and fixing/executing traditional Odisha decorative
plaster work of approved design and pattern, including
preparation and setting out of the surface, application of cement
mortar of specified grade and proportion, forming of traditional
Odisha architectural motifs, ornamental bands, floral/geometrical
patterns, mouldings, carvings, relief work and other decorative
elements as per approved architectural drawings, with necessary
reinforcement/supports wherever required, proper finishing,
profiling, smoothening and curing, including scaffolding, staging,
surface preparation, all materials, cement, sand, admixtures,
water, pigments/finish coats where specified, skilled
artisan/labour, tools,
tackles, transportation, lifting, wastage and all incidental works,
complete in all respects as per approved design, architectural
drawings, technical
specifications and directions of the Engineer-in-Charge.
Providing, development and executing artistic mural paintings on
public walls/facades for Urban Beautification, Cultural Promotion,
and Tourism Enhancement, including surface preparation, crack
filling, exterior primer, theme curation, painting with lightfast
21 NDSR exterior acrylics, and a protective anti-graffiti UV-resistant Sqm 40.000 7,500.00 3,00,000.00
aliphatic polyurethane topcoat, complete
in all respects at all heights as per approved design, architectural
drawings , Technical Specification, DPR and directions of Engineer-
Providing and Fixing Toughened/Tempered Glass Door with
3 NDSR Stainless Steel Fittings, Floor Spring, Handles, Locking Nos 2.000 2,57,493.00 - 5,14,986.00
Arrangement, and Allied Hardware Complete.
Providing and Fixing Premium Decorative Main Entrance/Exit
Door with High Quality Frame, Shutter, Designer Finishing, SS
Hardware Fittings, Locking Arrangement, Decorative Elements
and Allied Civil & Finishing Works Complete.
Installation of Decorative Lord Ganesh Statue with Architectural
5 NDSR Pedestal, Landscaping, Illumination, and Associated Development Nos 1.000 12,00,000.00 12,00,000.00
Dismantling of Existing Staircase and Construction of New RCC
Staircase including Demolition, Disposal of Debris, RCC Works,
Reinforcement, Formwork, Finishing and Allied Civil Works
Providing, fabricating, and installation of outdoor LED public
display boards made of MS/GI frame with ACP/vinyl graphic
panel, foundation, painting, illumination, and all allied works
Providing, supplying, installing, testing and commissioning of 400
kVA, 415V, 3-phase, 50 Hz CPCB-IV+ compliant silent type
Diesel Generator Set complete with diesel engine, alternator,
AMF control panel, acoustic enclosure, anti-vibration mountings,
residential silencer, fuel tank, battery and charger, foundation
bolts, earthing, cable termination and all accessories as required
for complete operation, including transportation,
loading/unloading and commissioning at site.
Digitally signed by JAYA
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate NDSR Rate DSR Amount. NDSR Amount.
Supplying Installation, Testing and Commissioning of on-grid
Solar Photovoltaic Power Plant conforming to various applicable
standards BIS, IEC, MNRE guidelines, the Central Electricity
Authority Regulations and CPWD Specifications as amended up to
date, consisting of Mono/Poly Crystalline silicon solar cells
module, net metering facility, necessary control, protections,
earthing, cabling, mounting structure, junction boxes, power
conditioning units, Real time online web interfaced Data
Monitoring System, Distribution panels, grid connecting
arrangement, conduits, pipes, cable trays and other accessories
etc. as required.
a) High Energy Efficiency Solar Photovoltaic Module of capacity
DSR 2025 330 Wp or above, manufactured in India, conforming to IS
17.1 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2.
Solar Photovoltaic Module conversion efficiency shall not be less
than 23% at STC with temperature coefficient of Pmax better
than -0.30% per 0C. PV modules used in solar power plants/
systems must be warranted for their output peak watt capacity,
which should not be less than 90% at the end of 10 years and
80% at the end of 25 years. Solar Modules shall be designed to
operate in relative humidity upto 100% with temperature
between -10 0C and +85 0C. Further, each PV module used in
any solar power project must have Radio frequency identification
tag with information such as name of manufacturer, month and
year of manufacturing, country of origin (separately for Solar cell
and module), I-V curve, Unique Serial No and Model No of the
Providing, supplying, installing, testing and commissioning of
hydraulic maintenance ladder / mobile hydraulic access platform
suitable for indoor and outdoor maintenance works, having
hydraulically operated vertical lifting mechanism with adequate
working height, robust structural steel/aluminium platform, anti-
skid platform flooring, safety guardrails and toe guards, access
ladder/gate, heavy-duty wheels/castors with suitable
locking/stabilizing arrangement, hydraulic power pack,
electric/battery-operated drive/lifting system, control panel with
operating controls, emergency stop arrangement, overload
protection, emergency lowering arrangement, limit switches and
all other requisite safety devices. The equipment shall be
complete with battery and charger, hydraulic hoses, cylinders,
valves, electrical wiring, connectors, fasteners and all necessary
accessories. The item shall include transportation to site,
loading/unloading, assembly, installation, testing, trial operation,
commissioning and demonstration, including all labour, tools,
tackles, T&P and incidental works, complete in all respects as per
approved drawings, manufacturer's specifications and direction of
Engineer-in-Charge..
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
BILL OF QUANTITY
Sl. No. 2025 Description Unit Qty DSR Rate DSR Amount. NDSR Amount.
Supplying, Installation, Testing & Commissioning of Modular type
Variable Refrigerant Flow/Variable Refrigerant Volume air cooled
Outdoor units suitable for
cooling/heating having 100% hermetically sealed inverter type twin
Rotary/Scroll Compressor(s),minimum two compressors (with
individual separate PCB) for above 14HP modules, microprocessor
based Controller, top discharge type condensing unit(s), with R-410-A
Refrigerant or equivalent, vibration Isolators with suitable foundation
etc. complete as required. To have better efficiency condenser fan
shall be capable to operate at different speed with respect to load.The
unit shall deliver the rated capacity and in confirmation as per IS
18728:2024 and CPWD Specifications and work even at 50°C ambient
temperature without tripping. The system shall be able to deliver
1 31.3 100% of the rated capacity upto 39 °C. The unit shall be suitable to
work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS
compatible. The unit shall be filled with first charge of the refrigerant
and ready for use as required. The condenser should be coated with a
hydrophilic film to prevent water accumulation on the surface of the
heat exchanger, enhance water dispersion, and reduce the risk of
degradation, thereby improving overall performance and durability.
The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall
be as per Energy Conservation and Sustainable Building Code
(ECSBC) 2024 as below and complete as per CPWD specification,
connections, inter connections etc. as required. (For capacity <40 kWr
ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER
7.6 for Super ECSBC Building)
For Cooling or Heating or Both
i) 31.3.2 12 HP Cooling Only TOP Discharge ODU Nos. 2 273132 546264
ii) 31.3.3 16 HP Cooling Only TOP Discharge ODU Nos. 4 346544 1386176
iii) NDSR ODU Connecting Kit Nos. 6 7118 42708
Supply, installation, testing & commissioning of factory fabricated
Double Skin Floor Mounted VRV DX AHU (AHRI /
Eurovent Certified) fabricated out of extruded aluminium section
with 0.8 mm pre-plasticized / pre-coated Galvanised steel sheet
outside & 0.8 mm plain Galvanised steel sheet inside with backward
curved plug fan, fan section and fan motor TEFC type suitable for
operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 4/6/8 Row dx
type cooling coil made of Aluminium finned Copper tube with coil
section, polished stainless steel drain pan made out of 20 G sheet
duly insulated. The AHU panels shall be insulated with 23mm thick &
36 Kg/m³ density PU foam & shall have thermal break. The motor &
2 blower assembly shall be mounted on Aluminium extruded
section only. These AHUs shall have air inlet / outlet connection
made of 20 G GI sheet. The complete AHU shall conform to
specication & face velocity across cooling coil shall be decided
as per site. Static pressure given below is for guideline & actual
to be calculated. AHU DX coils shall be in tune with the requirement
of VRV Outdoor Unit capacity and no divisions shall be made in cross
sectional area of the coil. If multiple ins and outs of refrigerant pipe
are required then coils shall be grouped into required rows keeping
the cross sectional area of the coil constant. The capacity of Air-
handlers shall be as follows:
i) NDSR 26 TR 7000 CFM 6RD/8RD,FM AHU Nos. 2 972840 1945680
ii) NDSR AHU Kit for AHU Nos. 2 43982 87964
iii) NDSR Corded Remote Controller for AHU Nos. 2 4065 8130
Supply, installation, testing & commissioning of following Wall
Mounted Type Indoor unit equipped with cordless remote, synthetic
washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX copper coil,
electronic expansion valve, outer cabinet, insulation, necessary
supports etc, suitable for operation on 230 V ± 10%, 50 Hz single
phase AC supply, complete as required. The unit shall have automatic
force shut down provision Incase of fire. All indoor Units should
have force shut option to connect with fire alarm adaptor, so
that the unit automatically stops in case or fire. The cooling capacity
of indoor unit will be at air inlet conditions of 27 degree C DBT and 19
i) NDSR Nominal Capacity 2.56 TR Nos. 1 67435 67435
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
BILL OF QUANTITY
Sl. No. 2025 Description Unit Qty DSR Rate DSR Amount. NDSR Amount.
Supplying, Installation, Testing and Commissioning of following
minimum capacity 4 way Cassette Type Indoor ceiling mounted unit
equipped with synthetic washable media pre-filter, fan section with
low noise fan/dynamically balanced blower, multispeed motor, coil
section with DX Copper coil, electronic expansion valve, outer cabinet,
drain pump, grill, necessary supports, vibration Isolation,
Corded remote control etc., suitable for operation on single phase 230
V ± 10%, 50Hz AC supply, complete, as required. The Indoor units
must shut down upon receiving a singal from the BMS System/Fire
Singnals. The system shall be capable to adjust air flow as per room
requirement in auto mode. The cooling capacity of indoor unit will be
at air inlet conditions of 27 0C DB and 19 0C WB temperature.
(Make will be same as of Outdoor)
i) 31.4.4 Nominal Capacity 1.6 TR Nos. 1 39464 39464
ii) 31.4.5 Nominal Capacity 2.0 TR Nos. 3 39734 119202
Supply, installation, testing & commissioning of following minimum
capacity Celing Mounted VRV Duct Type Indoor ceiling mounted
unit equipped with cordless remote , synthetic washable media pre-
filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX copper coil,
electronic expansion valve, outer cabinet, drain pan, insulation,
necessary supports, vibration isolation etc, suitable for operation on
± 10%, 50 Hz single phase AC supply, complete as required. The unit
shall have automatic force shut down provision in case of fire. All
indoor Units should have force shut option to connect with fire alarm
adaptor, so that the unit automatically stops in case or fire. The
cooling capacity of indoor unit will be at air inlet conditions of 27
degree C DBT and 19 degree C WBT.
i) NDSR Nominal Capacity 2.56 TR Nos. 4 90042 360168
Supplying, Installation, Testing and Commissioning of Y/T/Multi
31.13 Joints. Joints shall be of same Original Equipment Manufacturer (OEM)
make as of ODUs and IDUs
31.13.1 Indoor Units Nos. 9 4535 40815
31.13.2 Outdoor Multi Joint Nos. 6 8098 48588
Supplying, Installation, testing and commissioning including
vaccumiazation and Nitrogen testing of following nominal sizes of
soft/hard drawn copper refrigerant piping for VRV/VRF system,
complete with fittings, with suitable adjustable ring type hanger
6 31.14 supports, jointing/brazing including accessories, insulated with XPLE
Class-O tubular insulation/with Class-O closed cell elastometric nitrile
rubber tubular sleeves sections of 19 mm thick insulation as given
below for Suction and Liquid lines, all accessories as per specifications
etc. as required :
i. 31.14.10 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62mm Mtr 40 1286 51440
ii. 31.14.8 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2mm Mtr 38 1157 43966
iii. 31.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2mm Mtr 12 904 10848
iv. 31.14.5 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Mtr 42 739 31038
v. 31.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2mm Mtr 39 615 23985
vi. 31.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 45 487 21915
vii. 31.14.2 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 68 346 23528
viii. 31.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Mtr 6 256 1536
Supplying and laying of Signal cable 2 core 1.5sq mm shielded with
following specifications:
7 NDSR 18 AWG, Conductor Material- Tinned Copper,Jacket (Insulation) Mtr 185 210 38850
,Material- Poly-Vinyl Chloride (PVC),UL Voltage Rating- 300 V RMS,
etc as required.
8 NDSR Gas Charging for the entire circuit(R410A) Kg 80 1320 105600
Providing & fixing of PVC Drain Pipe complete with fittings,
supports as per specifications and duly insulated with 9 mm
9 thickness Class O of closed cell nitrile rubber/XLPE as per direction of
Engineer-in-charge & specifications enclosed as reqd.
i) NDSR 50 mm dia Mtr 12 365 4380
ii) NDSR 32 mm dia Mtr 62 265 16430
iii) NDSR 25 mm dia Mtr 8 165 1320
Supplying, installation, balancing and commissioning of fabricated at
site GSS sheet metal rectangular/round ducting complete with
neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
10 30.12.2 supports, bends, transitions, reducers, end caps, collars etc as
required complete in all respect in confirmation with IS : 655 and
approved drawings and specifications of following sheet thickness
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
BILL OF QUANTITY
Sl. No. 2025 Description Unit Qty DSR Rate DSR Amount. NDSR Amount.
Supply and application of acoustic insulation for the initial portion of
supply air ducting. Material of construction shall be cross linked
polyolefin foam. Elastomeric nitrile rubber material with open cell
11 structure without any fibre material. density of same shall be within
140-180 Kg/m3. Thickness of material shall be minimum 13mm. The
insulation material shall be stuck to the cleaned duct surface by
i) NDSR Sqmtr 146 825 120450
Supply of thermal insulation with Class 'O' with Aluminium foil.
Should properly cover with all supply air ducts collars except the area
of accoustic insulation. Material of construction shall be cross linked
polyolefin, polyethelene form material with closed cell structure
andwith factory applied reinforced aluminium foil.
12 Densiy shall be 45-50 Kg/m3. Thickness of the material shall be
10mm. The insulation material shall be stick to the cleaned duct
surface by cold adhesive. The material and installation methedology
should be in accordance with the specifications and
i) NDSR Sqmtr 62 1080 66960
Supplying, Fixing, installation, testing and commissioning of powder
coated extruded aluminium Supply Air Grills with aluminium volume
13 30.15 control dampers in confirmation to SMACNA/IS and as per Sqmtr 14 9623 134722
specifications complete etc. as required.
Supplying & fixing of powder coated extruded aluminium Return Air
13A Grills with louvers but without volume control dampers complete in 14 6285 87990
confirmation to SMACNA/IS and as per specifications complete etc. as
14 NDSR Installation of Mouth piece canvas connection Nos. 8 8800 70400
Installation, testing and commissioning of expansion kit for DX type
15 NDSR AHU. (Actual quantity to be work out by HVAC contrcator as per coil Nos. 2 2750 5500
Installation, testing and commissioning of communication kit for DX
16 NDSR type AHU. (Actual quantity to be work out by HVAC contrcator as per Nos. 2 2750 5500
coil selection)
Supply Installation Testing and Commissioning of Inline Fan for Toilet
Supplying, Installation, testing and commissioning of Propeller Fan
Supplying, Fixing, testing and commissioning of fire dampers of
minimum 90 minutes fire rated in supply air duct/main branch and
return air path as and where
required of required sizes i/c control wiring, the damper shall be
motorized and spring return so as to close the damper in the event of
19 30.20 power failure automatically and open the same in case of power being
restored. The spring return action shall be inbuilt mechanism and not
externally mounted. The damper shall also be closed in the event of
fire signal and, in confirmation to IS and as per specifications
complete etc. as required.
iii) NDSR UL listed Fusible Link Nos. 2 1050 2100
Supply Installation Testing and Commissioning of VRF Central
Providing and fixing Fire retardant non porous double layer flexible
connection between each Indoor unit and duct.
22 NDSR Providing & Fixing MS Stand for VRF Outdoor Units Nos. 4 10500 42000
Total Cost = 2917881 3226805
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
1.00 WIRING SYSTEM (POINT WIRING)
NOTE : ALL WIRES SHALL BE FRLS ONLY
The following light points are done with 2R x 2.5Sqmm ( phase and neutral) +
1 x 1.5Sqmm (earth) stranded Cu PVC insulated FRLS flexible wires of
650/1100V grade. The cost to include - 16 SWG MS conduits, inspection
bends, collars, coupler, saddles, clamps, check nut, junction boxes with cover
plates, FRLS wires, terminations, wire connectors, angle holders, flexible pipe,
GI back boxes, earthing, one way/ two way polycarbonate modular switch,
frames, cover plates plates etc inclusive of all accessories in surface/ concealed
manner as required for final installation of light fixtures.
Same as above considering below.Primary light point controlled by 1Nos one
1 NDSR way 6A switch (from switch board to first light point - cost of switch & board NOS 40 1125 45000
included). Avg. length- 6mtr.
Same as above considering below.Secondary light point looped from above and
subsequent loops . Avg. length- 5mtr.
Same as above considering below.Primary light point controlled by 2Nos two
3 NDSR way 6A switch (from switch board to first light point - cost of switch & board NOS 10 3560 35600
included). Avg. length- 20mtr.
Same as above considering below.Secondary light point looped from above and
subsequent loops. Avg. length- 8mtr.
Same as above considering below.Primary light point controlled by MCB
directly from DB. Avg. length-20mtr.
Same as above considering below.Secondary light point looped from above and
subsequent loops. Avg. length- 6mtr.
Same as above considering below. Primary light point controlled by fuse from
7 NDSR Dimmer panel with 2R x 2.5Sqmm stranded Cu PVC insulated FRLS flexible NOS 12 3150 37800
wire. Avg. length- 20mtr.
Same as above considering below. Secondary light point looped from above
8 NDSR and subsequent loops with 2R x 2.5Sqmm stranded Cu PVC insulated FRLS NOS 30 990 29700
flexible wire. Avg. length-6mtr.
The following light points are done with 2R x 2.5 Sqmm for primary and 2R x
1.5 Sqmm for secondary HMS FRLS PVC conduits, inspection bends, collars,
coupler, saddles, clamps, check nut, junction boxes with cover plates, FRLS
wires, terminations, wire connectors, angle holders, flexible pipe, GI back
boxes, earthing etc inclusive of all accessories in surface/ concealed manner as
required for final installation of step light.
Same as above considering below. Primary step light point with 2R x 2.5
Sqmm stranded Cu PVC insulated FRLS flexible wire. Avg. length-20mtr.
Same as above considering below. Secondary step light point looped from
2 NDSR above and subsequent loops with 2R x 1.5 Sqmm stranded Cu PVC insulated NOS 160 510 81600
FRLS flexible wire. Avg. length-2.5mtr.
The following power points are done with 2R x 2.5Sqmm (phase and neutral) +
1x1.5Sqmm (earth) stranded Cu PVC insulated FRLS flexible wires of
650/1100V grade. The cost to include- 16 SWG MS conduits, inspection bends,
collar, coupler, saddles, clamps, check nut, junction boxes with cover plates,
FRLS wires, terminations, flexible pipe, GI back boxes, earthing, polycarbonate
switch, shuttered socket, frame, cover plates (of colours white/grey/black) as
per drawings and instructions of the site incharge inclusive of all accessories in
surface/ concealed manner as required for final installation of power point.
Same as above considering below. Primary power point with 1Nos 230V 6A, 3-
1 NDSR pin socket outlet controlled by 1Nos 6A switch located on switch board. Avg. NOS 20 2900 58000
Same as above considering below. Secondary power point looped from above
2 NDSR and subsequent loops with 1Nos 230V 6A, 3-pin socket outlet controlled by NOS 40 1125 45000
1Nos 6A switch located on switch board. Avg. length- 5mtr.
Same as above considering below. Primary power point with 2Nos 230V 6A, 3-
3 NDSR pin socket outlet controlled by 2Nos 6A switch located on switch board. Avg. NOS 20 2925 58500
Same as above considering below. Secondary power point looped from above
4 NDSR and subsequent loops with 2Nos 230V 6A, 3-pin socket outlet controlled by NOS 40 1175 47000
2Nos 6A switch located on switch board. Avg. length- 5mtr.
Same as above considering below. Primary power point with 3Nos 230V 6A, 3-
5 NDSR pin socket outlet controlled by 1Nos 6A switch located on switch board. Avg. NOS 20 3075 61500
Same as above considering below. Secondary power point looped from above
6 NDSR and subsequent loops with 3Nos 230V 6A, 3-pin socket outlet controlled by NOS 20 1250 25000
1Nos 6A switch located on switch board. Avg. length- 5mtr.
Same as above considering below. Secondary power point looped from above
7 NDSR and subsequent loops with 5Nos 230V 6A, 3-pin socket outlet controlled by NOS 20 1450 29000
1Nos 10A switch located on switch board. Avg. length- 5mtr.
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
The following power points are done with 2R x 4Sqmm (phase and neutral) +
1x2.5Sqmm (earth) stranded Cu PVC insulated FRLS flexible wires of
650/1100V grade. The cost to include- 16 SWG MS conduit, inspection bends,
collar, coupler, saddles, clamps, check nut, junction boxes with cover plates,
FRLS wires, terminations, flexible pipe, GI back boxes, earthing, polycarbonate
switch, shuttered socket, frame, cover plates (of colours white/grey/black) as
per drawings and instructions of the site incharge inclusive of all accessories in
surface/ concealed manner as required for final installation of power point.
Same as above considering below. Primary power point with 1Nos 230V 6/16A,
1 NDSR 3-pin socket outlet controlled by 1Nos 16A switch located on switch board. NOS 20 3725 74500
Avg. length- 15mtr.
Same as above considering below. Secondary power point looped from above
2 NDSR and subsequent loops with 1Nos 230V 6/16A, 3-pin socket outlet controlled by NOS 30 2115 63450
1Nos 16A switch located on switch board. Avg. length- 8mtr.
Same as above considering below. Primary power point with 2Nos 230V 6/16A,
3 NDSR 3-pin socket outlet controlled by 2Nos 16A switch located on switch board. NOS 20 3725 74500
Avg. length- 15mtr.
Same as above considering below. Secondary power point looped from above
4 NDSR and subsequent loops with 2Nos 230V 6/16A, 3-pin socket outlet controlled by NOS 30 2145 64350
2Nos 16A switch located on switch board. Avg. length- 8mtr.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
DSR sq.mm FRLS PVC insulated copper conductor single core cable in surface /
5 2025 recessed medium class PVC conduit, with modular switch, modular plate, Nos. 50.00 1704.00 85,200.00
1.10.3 suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call
DSR bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC
6 2025 insulated copper conductor single core cable in surface/ recessed PVC conduit, Nos. 100.00 1246.00 1,24,600.00
1.54.3 and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor
single core cable etc. as required. Group C
DSR Supplying & Fixing suitable size GI Box with moduler plate & cover infront on
7 2025 surface or in recess including providing & fixing 3pin 5/6A moduler socket Each 40.00 545.00 21,800.00
1.31 outlet and 5/6 A moduler switch, connections etc as required
DSR Supplying & Fixing suitable size GI Box with moduler plate & cover infront on
8 2025 surface or in recess including providing & fixing 6pin 5/6A & 15/16A moduler Each 40.00 659.00 26,360.00
1.32 socket outlet and 15/16 A moduler switch, connections etc as required
2.00 CIRCUIT WIRING - MAINS & SUB MAINS
Providing and drawing mains and sub-mains of the following sizes of stranded
A Cu PVC insulated FRLS flexible wires of 650/1100V grade in suitable size 16
SWG MS conduit,with all necessary accessories in surface/ concealed manner.
DSR Same as above considering below. 2Rx16Sqmm +1Rx6Sqmm stranded Cu PVC
1.7.6 insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
DSR Same as above considering below. 2Rx10Sqmm +1Rx6Sqmm stranded Cu PVC
1.7.5 insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
Same as above considering below. 2Rx6Sqmm + 1Rx4Sqmm stranded Cu PVC
insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
Same as above considering below. 2Rx4Sqmm + 1Rx2.5Sqmm stranded Cu
PVC insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
Same as above considering below. 2Rx2.5Sq.mm + 1Rx1.5 Sq.mm stranded
Cu PVC insulated FRLS flexible wires in suitable size 16 SWG MS conduit. For
urinal sensor, DB to dimmer panel, DB to switchboard, switchboard to
switchboard, switchboard to light point.
Same as above considering below. 4Rx6Sqmm + 2Rx4Sqmm stranded Cu PVC
insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
DSR Same as above considering below. 4Rx10Sqmm + 2Rx6Sqmm stranded Cu
1.7.10 PVC insulated FRLS flexible wires in suitable size 16 SWG MS conduit.
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper
conductor single core cable in surface/ recessed medium class PVC conduit
along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single
core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes
of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq.
Supplying and fixing of following sizes of medium class PVC conduit along with
B 1.21 accessories in surface/recess including cutting the wall and making good the
same in case of recessed conduit as required.
1 PVC CONDUIT - 32MM DIA MTR 100 209 20900
2 PVC CONDUIT - 25MM DIA MTR 1000 168 168000
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
3 PVC CONDUIT - 20MM DIA MTR 150 151 22650
Supplying and fixing of following sizes of steel conduit along with accessories in
C 1.20 surface/recess including painting in case of surface conduit, or cutting the wall
and making good the same in case of recessed conduit as required.
1 MS CONDUIT - 25MM DIA MTR 200 289 57800
2 MS CONDUIT - 20MM DIA MTR 50 254 12700
Supplying and fixing metal box of following sizes (nominal size) on surface or
D in recess with suitable size of phenolic laminated sheet cover in front including
painting etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular
E 1.24 plate & switch box including connections but excluding modular plate etc. as
4 1.24.4 3 pin 5/6 A socket outlet Nos 40 136 5440
5 1.24.5 6 pin 15/16 A socket outlet Nos 40 219 8760
6 1.24.6 Telephone socket outlet Nos 10 168 1680
Supplying and fixing following size/ modules, GI box along with modular base
& cover plate for modular switches in recess etc. as required.
3.00 L.V.CABLES, GI RACEWAY & TRAYS
Providing, laying, testing and commissioning of 1100V grade aluminium/
copper stranded conductor, PVC/ XLPE insulated, PVC sheathed, steel wire/
strip armoured / unarmoured cable for mains and sub mains as per
specifications and drawings. The cables shall be laid in concrete trenches or
A buried directly underground or on wall or on cable trays complete with
dressing, saddling, cable tags, cable tie, clamps etc. as required for proper
installation. The concrete trenches will be measured separate. The cost of the
cable trays or ladders, excavation and back filling of trenches will be measured
1 NDSR 3.5C X 240SQMM A2XFY CABLE MTR 10 2050 20500
2 NDSR 3.5C X185SQMM A2XFY CABLE MTR 50 1650 82500
3 NDSR 3.5C X 95SQMM A2XFY CABLE MTR 50 980 49000
4 NDSR 3.5C X 50SQMM A2XFY CABLE MTR 10 590 5900
5 NDSR 3.5C X 35SQMM A2XFY CABLE MTR 10 510 5100
6 NDSR 3.5C X 25SQMM A2XFY CABLE MTR 10 470 4700
7 NDSR 4C X 16SQMM 2XFY CABLE MTR 150 1480 222000
8 NDSR 4C X 10SQMM 2XFY CABLE MTR 150 970 145500
9 NDSR 4C X 6SQMM 2XWY CABLE MTR 150 510 76500
10 NDSR 4C X 4SQMM 2XWY CABLE MTR 50 410 20500
11 NDSR 3C X 10SQMM 2XFY CABLE MTR 50 780 39000
12 NDSR 3C X 6SQMM 2XWY CABLE MTR 50 505 25250
13 NDSR 3C X 4SQMM 2XWY CABLE MTR 200 385 77000
14 NDSR 3C X 2.5SQMM 2XWY CABLE MTR 50 280 14000
Same as above considering below 2C x 4 Sqmm double insulated Cu. flexible
cable (for LED strip first Point including 16 SWG MS conduit & Accessories
(from driver to first point on strip/cove/profile/signage light as per direction of
Engineer Incharge )
Same as above considering below 2C x 2.5 Sqmm double insulated Cu. flexible
cable including 16 SWG MS conduit & Accessories ( from first point to second
point on strip/cove/profile/signage light and sub-sequent loop as per direction
of Engineer Incharge )
17 NDSR 1C X 16SQMM CU FLEX CABLE MTR 20 442 8840
18 NDSR 1C X 10SQMM CU FLEX CABLE MTR 20 290 5800
19 NDSR 1C X 6SQMM CU FLEX CABLE MTR 20 195 3900
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
20 NDSR 1C X 4SQMM CU FLEX CABLE MTR 20 175 3500
Supplying and making end termination with brass compression gland and
C 11.1 aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade as required.
1 11.1.29 3.5C X 240SQMM A2XFY CABLE NOS 2 1160 2320
2 11.1.27 3.5C X 185SQMM A2XFY CABLE NOS 2 1001 2002
3 11.1.24 3.5C X 95SQMM A2XFY CABLE NOS 2 684 1368
4 11.1.22 3.5C X 50 SQMM A2XFY CABLE NOS 2 484 968
5 11.1.21 3.5C X 35 SQMM A2XFY CABLE NOS 2 437 874
6 11.1.34 4C X 25 SQMM A2XFY CABLE NOS 2 373 746
7 11.1.33 4C X 16SQMM A2XFY CABLE NOS 32 366 11712
8 NDSR 4C X 6 SQMM 2XWY CABLE NOS 18 350 6300
9 NDSR 4C X 4 SQMM 2XWY CABLE NOS 4 340 1360
10 NDSR 3C X 4 SQMM 2XWY CABLE NOS 4 340 1360
11 NDSR 3C X 2.5 SQMM 2XWY CABLE NOS 4 330 1320
12 NDSR 2C X 4SQMM DOUBLE INSULATED CU FLEX CABLE NOS 40 330 13200
13 NDSR 2C X 2.5SQMM DOUBLE INSULATED CU FLEX CABLE NOS 40 325 13000
14 NDSR 1C X 16SQMM CU FLEX CABLE NOS 18 500 9000
15 NDSR 1C X 10SQMM CU FLEX CABLE NOS 2 450 900
16 NDSR 1C X 6SQMM CU FLEX CABLE NOS 2 380 760
17 NDSR 1C X 4SQMM CU FLEX CABLE NOS 2 290 580
Supplying and installing following size of perforated Hot Dipped Galvanised
Iron cable tray (Galvanisation thickness not less than 50 microns) with
E DSR 4.6 perforation not more than 17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with two numbers GI Suspenders i/c
base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
1 4.6.6 450 mm width X 50 mm depth X 2.0 mm thickness MTR 40 1439 57560
2 4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness MTR 30 1062 31860
3 4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness MTR 70 803 56210
Supply & installation of wall/ceiling mounted GI raceway 1.6mm thick with
openable cover. The rate shall include all accessories required for wall
F mounting, floor run, ceiling hung etc. with all neccessary MS/GI supports, RCC
fastners, threaded rod, MS/GI bolts - nuts - washers etc. Cost of MS supports
1 NDSR GI RACEWAY - 200 X 50MM 1.6MM THK WITH COVER MTR 60 2150 129000
2 NDSR GI RACEWAY - 100 X 50MM 1.6MM THK WITH COVER MTR 25 1300 32500
3 NDSR GI RACEWAY- 150 X 50MM 1.6MM THK WITH COVER MTR 60 1780 106800
4 NDSR GI RACEWAY- 50 X 50MM 1.6MM THK WITH COVER MTR 50 850 42500
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
Supply & installation of wall/ceiling mounted GI junction boxes with top
openable cover's
1 NDSR GI JUNCTION BOX -225 X 225 X 75 mm NOS 4 940 3760
2 NDSR GI JUNCTION BOX - 175 X 175 X 75 mm NOS 4 775 3100
3 NDSR GI JUNCTION BOX- 75 X 75 X 75 mm NOS 4 460 1840
Supply and laying of MS angle (MS sections of all types and sizes with welding
and all types of fastened arrangements etc.) as per site manager's approval.
4.00 LT PANELS AND DISTRIBUTION BOARDS
Supply, installation, testing and commissioning of M.V.Distribution Boards
suitable for 415V, 3 ph, 4 wire, 50Hz distribution system. The panel shall be
free standing, floor mounting, sheet metal enclosed, flush front with aluminium
busbars, separate earth bus shall be provided throughout the length of the
panel. The incoming and the outgoing feeder breakers, switch fuse units,
change over switches, indicating lamps, meters etc. shall be accommodated in
a modular multi tier arrangement. A minimum of 400mm clearance shall be
given from the floor level to the bottom most termination point. The painting
A shall be done in conformity with IS code. Adequate size cable alley shall be
provided all round the panel and at the back for easy bending and
terminations. The outgoing feeders inside the panel shall be connected through
solid busbars. Flexible cable links are not acceptable. Busbars shall be provided
with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels
shall be suitable for cable entry from top. The copper earth strip of minimum
25mm x 3mm shall run throught out the length of the top / bottom of the
panel ( All MCCB'c are Thermal magnetic released MCCB'S), All the MCCB,s
should have rotary handle (RHOM)
The construction of the panel shall comply to latest standards of IEC 60439.
b The Panel shall be fully as per the requirement of Electrical Inspectorate/ CEIG
c Auxilliary contactor to be provided along with auto-manual switch .
d All doors to have double rubber gasket with shutter assembly & door seating
e Any panel if more than 2.5 mts width should be made in parts each part not
exceeding 2.5mts
All UPS outgoing panels shall have neutral busbars double the size of phase.
g Breaker terminal connections from the dropper bus shall be through only
Al/Cu. bus to be used.
h The Bus bars and connectors should have extruded insulation
Base frame shall be with each panel. The size will be equal to each section.
j Bi-metallic tape / washers to be used where ever copper & Aluminium are
k Auto-Manual switch shall be provided for all motorised breakers.
l All the DB's should be installed with suitable cable end boxes or suitable
m Specification proposed only for Tender purpose. The contractor has to submit
final BOM for our approval as per SLD.
Contractor should refer drawings and site conditions before quoting the panels.
o Panel vendor should submit actual BOM as per SLD. All the panels shall be as
p IP-54 for indoor type and IP-65 for outdoor type
q Prior ordering any items contractor has to take approval from PVR Site/Project
Basic description same as above
MAIN LT PANEL ( Refer SLD ) (Indoor type)
Incomer-1 & 2:-
500A FP MCCB, 36kA microprocessor based O/L, S/C and E/F release-2 Set
with mechanical and eletcrical interlock - 2 Set
Metering & Protection:- (each incomer)
Breaker ON / OFF / TRIP indicating lamps with suitable rating control SP MCB -
RYB phase indicating lamps with suitable rating control SP MCB - 1Set
MFM with RS-485 port- 1Set (parameters V, I, Hz, KWH, PF, KW, KVAR, max.
CT 630/5A 15 VA, CL.1- 3 Nos
630A TPN Al busbar (36KA) insulated with colour coded heat shrinkable
sleeves. Current density 0.8A/ Sqmm.
100A FP MCCB, 25kA thermal magnetic based O/L, S/C release- 2Set
63A FP MCB, 10kA-10Nos
40A FP MCB, 10kA-13Nos
32A FP MCB, 10kA-10Nos
32A DP MCB, 10kA-4Nos
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
Basic description same as above
2 NDSR UPS OUTPUT PANEL (30KVA) (Indoor type) SET 1 155900 155900
63A FP Changeover switch- 1Set
63A FP MCCB,25kA thermal magnetic based O/L, S/C release - 1Set
Metering & Protection:-
Breaker ON / OFF / TRIP indicating lamps with suitable rating control SP MCB -
RYB phase indicating lamps with suitable rating control SP MCB - 1Set
Digital voltmeter- 1Set
100A TP+2N Cu busbar (25KA) insulated with colour coded heat shrinkable
sleeves. Current density 1.4A/ Sqmm.
63A FP MCB 10kA- 4Nos
DOL starter for 3.7kW motor:- 6.3-10A TP MPCB, 50kA, 25A TP contactor
with 2NO and 2NC conatcts, 0-25A ammeter with CTs, trip indicating lamp
with control SP MCB, start and stop push button illuminated type with remote
control start, stop arrangement, Auto/ manual/ off selector switch. Starter
shall have fire integration (potential free contacts) provision and power
provision for motorised fire damper.
DOL starter for 2.2kW motor:- 4-6.3A TP MPCB, 50kA, 22A TP contactor
with 2NO and 2NC conatcts, 0-25A ammeter with CTs, trip indicating lamp
with control SP MCB, start and stop push button illuminated type with remote
control start, stop arrangement, Auto/ manual/ off selector switch. Starter
shall have fire integration (potential free contacts) provision and power
provision for motorised fire damper.
DOL starter for 5.5kW motor:-9-13A TP MPCB, 50kA, 32A TP contactor with
2NO and 2NC conatcts, 0-25A ammeter with CTs, trip indicating lamp with
control SP MCB, start and stop push button illuminated type with remote
control start, stop arrangement, Auto/ manual/ off selector switch.
For all starters, follow type-2 co-ordination chart of OEM.
Supply, installation, testing and commissioning of the following
Distribution Boards made of 18 gauge powder coated MS sheet steel,
Cu busbar, wall mounted/fully recessed in wall, indoor industrial type,
with dust proof, hinged and lockable doors, double door design,
B NDSR complete with inter connecting wires from incomer MCB to each RCCB
along with earthing terminal. The top and bottom of the box shall have
adequate number of knockouts suitable to receive the conduits and
cables. All MCB to be 10kA. All MCBs are C curve except UPS DBs. IP-
Basic description same as above
LPDB-A-1, 2 ( Audi lighting and power DB)
12 way TPN DB per phase isolation
40A FP MCB, 10kA- 1Nos
40A DP RCCB, 100mA- 3Nos with 40A DP 2NO contactor-1Nos
10-32A SP MCB, 10kA- 28Nos
Basic description same as above
ELDB-A-1,2 ( Audi emergency lighting DB)
25A DP RCBO, 30mA- 1Nos
10-20A SP MCB, 10kA- 8Nos
Basic description same as above UPSDB-A-1, 2
( Sound and projection equipment DB)
Flexi DB 4Rx14module
63A FP MCB, 10kA- 1Nos
40A DP RCCB, 100mA- 3Nos
10-32A SP MCB, 10kA D curve- 10Nos
40A SP MCB, 10kA D curve- 2Nos
32A FP MCB, 10kA D curve- 2Nos
Basic description same as above
LDB-1,2 ( Lobby lighting DB)
12 way TPN DB per phase isolation
40A FP MCB, 10kA- 1Nos
40A DP RCCB, 30mA- 3Nos
10A SP MCB, 10kA- 24Nos
Basic description same as above
PDB-2 ( Lobby power DB)
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
12 way TPN DB per phase isolation
40A FP MCB, 10kA- 1Nos
40A DP RCCB, 100mA- 3Nos
10-32A SP MCB, 10kA- 30Nos
Basic description same as above
ELDB-1 ( Lobby emergency lighting DB)
25A DP RCBO, 30mA- 1Nos
10A SP MCB, 10kA- 8Nos
Basic description same as above
32A DP RCBO, 100mA- 1Nos
10-32A SP MCB, 10kA D curve- 16Nos
Basic description same as above
COLD DB ( Concession equipment DB)
Flexi DB 4R14 Module
100A FP MCB, 10kA- 1Nos
63A DP RCCB, 100mA- 3Nos
10-32A SP MCB, 10kA- 10 Nos
40A SP MCB , 2 Nos
32 FP , MCB, 3 nos
Supply & installation 3-phase , 32A , 5 pin industrial socket and plug top
controlled by 32A, FP MCB in a metallic enclosure. IP-44
Supply & installation 1-phase , 32A , 3 pin industrial socket and plug top
controlled by 32A, DP MCB in a metallic enclosure. IP-44
Supply & installation 1-phase, 16A 3 pin industrial socket and plug top
controlled by 16A, DP MCB in a metallic enclosure. IP-44
Supply & installation 1-phase, 25A 3 pin industrial socket and plug top
controlled by 25A, DP MCB in a metallic enclosure. IP-44
Supply & installation 1-phase, 40A 3 pin industrial socket and plug top
controlled by 40A, DP MCB in a metallic enclosure. IP-44
Supply & installation 1-phase, 20A 3 pin metal clad socket and plug top
controlled by 20A, DP MCB in a metallic enclosure ( For Hi-wall unit)
Supply & installation 3-phase 100A, FP MCCB, 25kA thermal magnetic O/L, S/C
7 NDSR release as an Isolator switch in a metallic enclosure with cable entry provision NOS 2 14500 29000
from both top and bottom.
Supply & installation 1-phase 40A/ 63A, DP MCB as an Isolator switch in a
8 NDSR metallic enclosure with cable entry provision from both top and bottom. (For NOS 1 8850 8850
10KVA UPS, IT and audi emergency lighting)
Supply & installation 1-phase 63A, FP MCB as an Isolator switch in a metallic
enclosure with cable entry provision from both top and bottom. (For 30KVA )
Supply & installation 1-phase 32A, DP MCB as an Isolator switch in a metallic
enclosure with cable entry provision from both top and bottom.
Supply, installation, testing and comissioning of 32A DP 2NO contactor in metal
Supply & installation 1-phase 25A/ 32A, TP Isolator as an Isolator switch in a
12 NDSR weatherproof enclosure with cable entry provision from both top and bottom. NOS 1 3850 3850
5.00 EARTHING SYSTEM
Supply, installation, testing & commissioning of 14.35 mm dia and 3 meter
length copper bonded earth rod in 150 mm dia. in an augured hole in ground ,
surrounded by ground enhancement material as per specification. Inspection
chamber shall be of 300 x 300 mm with concrete base CI manhole cover with
A NDSR frame painted with bitumastic paint. 2 Nos. of 50 x 6 mm cross section & 300 NOS 6 19500 117000
mm long copper strip to be clamped with copper claded rod electrode have
sufficient nos ( But not less than 4 Nos.) of 10 mm dia. GI nuts & bolts for
connection to the equipment / interconnection to the other pits to form equi-
potential bonding. ( For UPS, projection equipment and server rack)
Supply,installation,testing & comissioning of GI earth bus bar of size 25 mm x
6 mm x 400 mm (W x B x L) mounted on insulators, in suitable size painted
MS box with acrylic cover. Bus bar should have holes with brass nutbolts of
Supply, installation, testing & comissioning of copper earth bus of size 25 mm
x 6 mm x 250 mm (W x B x L) mounted on insulators, in suitable size painted
MS box with acrylic cover. Bus bar should have holes with brass nutbolts of
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
Supply and fixing of following GI/ Cu wires & tapes on existing tray/ trench/
ground / PVC pipe / walls including all necessary fixing accessories and
effecting connections with riveting / welding etc. as approved by engineer in
charge complete as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for
connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for
connections etc. as required.
Providing and fixing 25 mm X 3 mm G.I. strip on surface or in recess for
connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop
earthing as required.
Supply, laying, connection, testing and commissioning of following sizes of
1.1kV grade single core FR PVC insulated unsheathed industrial flexible cable in
existing laid conduit, raceway, tray. It should include both ends terminal joints
providing tinned copper terminal lugs, single compression nylon cable glands,
insulation tape, effecting terminal connections to the equipment complete as
1 NDSR 1C X 35SQMM CU FLEX CABLE MTR 20 1110 22200
2 NDSR 1C X 16SQMM CU FLEX CABLE MTR 150 462 69300
3 NDSR 1C X 10SQMM CU FLEX WIRE MTR 150 290 43500
4 NDSR 1C X 6SQMM CU FLEX WIRE MTR 250 210 52500
5 NDSR 1C X 4SQMM CU FLEX WIRE MTR 50 175 8750
6.00 LIGHT FIXTURES
1 Providing & Installation of 24-26W LED Tube light fixture . NOS 50 797 39850
Providing, Installation, testing and commissioning of 24W cleaner downlight -
Recessed, Non-adjustable
DSR Providing, Installation, testing and commissioning of recessed mounted 18
8.3.4 watt LED down light fixture with Driver.
Providing Installation, testing and commissioning of 16W LED downlight -
Recessed, Non-adjustable (Dimmable)
Providing, Installation, testing and commissioning of 1meter length LED
6 NDSR Providing & fixing of Led strip light Rmt. 200 650 130000
7 NDSR Providing, Installation, testing and commissioning of LED exit signage boxes NOS 8 1300 10400
Receiving, fixing in position effecting proper connections testing and
commissioning of Dimmer Panel complete as required with all accessories.
7.00 COMMUNICATION DATA AND VOICE
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed
1 copper conductor, unarmored telephone cable in the existing surface/ recessed MTR 50 344 17200
steel/ PVC Conduit etc. complete as required.
2 NDSR TAG Box suitable for 100pair armoured cu tel cable with crown NOS 1 9500 9500
3 NDSR TAG Box suitable for 20pair armoured cu tel cable with crown SET 1 2550 2550
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated
DSR annealed copper
1.18.2 conductor, unarmored telephone cable in the existing surface/ recessed steel/
PVC conduit as required. 2 Pair
5 2025 Supply and installation of 4 Pair CAT 6A UTP cable in existing conduit MTR 2500 74 185000
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
conductor PE insulated, shielded with fine tinned copper braid and protected
with PVC sheath in the existing surface/ recessed steel/ PVC conduit as
Supply, installation, testing and commissioning of clip on telephone type
7 NDSR outlet mounted on a GI outlet box with front plate and all necessary NOS 10 650 6500
accessories complete as required including the termination of wires.(RJ11)
Supply, installation, testing and commissioning of clip on Data outlet
8 NDSR mounted on a GI outlet box with front plate and all necessary accessories NOS 40 750 30000
complete as required including the termination of wires.(RJ45)
Supply and ,installation floor mounted Ega box 250 mm by 250 mm for
housing 2Nos 6A socket with 1Nos 6A switch on UPS and 1Nos 6A socket with
1Nos 6A switch on Raw power and 2Nos data/voice boxes complete as
required. ( For QR code scanner)
Supply and ,installation floor mounted Ega box 100 mm by 100 mm for
housing 6/16A switch and socket complete as required. (For DFMD)
8.00 SAFETY / MISCELLENIOUS ITEMS
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
SR. 2025 DSR NDSR DSR NDSR
Description UNIT QTY
NO. E&M RATE Rate AMOUNT AMOUNT
Providing and fixing in position the best quality 415 kV danger boards of
1 NDSR approved shape and size as specified by the local electrical authorities written NOS 2 1350 2700
in English and local language.
2 NDSR Supply and fixing of 4.5 litres capacity CO2 fire extinguisher as required. NOS 10 5600 56000
3 NDSR Supply and fixing of 4.5 litres capacity ABC fire extinguisher as required. NOS 10 2950 29500
Providing and fixing in position approved shock treatment chart written in
4 NDSR English and Local Language. The chart shall be framed in Teakwood and NOS 2 3800 7600
covered with glass.
Supply and fixing in position fire buckets duly signed and fixed on an angle
iron frame as per the requirements of local Electricity authorities.
6 NDSR First Aid Box 300x300 with all necessory Kit NOS 1 1500 1500
GRAND TOTAL 16,14,270 53,37,900
GRAND TOTAL 16,14,270 53,37,900
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
Non DSR NON DSR
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate DSR Amount.
Supplying Installation, Testing and Commissioning of Circular 50W
RGBW Facade Projector luminaire for facade lighting with Pressure
Die-cast aluminium housing, powder-coated finish, with inbuilt
driver of following wattage as given below. The luminaire bracket
shall be made of cold-rolled steel & shall be so designed that the
luminaire can be tilted to ±90°, the scale shall be provided for
rotation degrees. The luminaire shall be IP66 protection also
having silicon gasket between optical cover & LED chamber to
ensure proper IP66 protection and impact resistance of IK 07.
CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under
voltage, over voltage protection, driver inbuilt surge protection of
4KV and external surge protection (SPD) of 10 KV common
mode/differential mode, Driver Efficiency>85% . There should be
options of beam angles of 30 degree. Luminaire should have
efficacy of minimum 35 lm/W for RGBW for mono colour options.
Luminaire shall be capable of producing dynamic colour changing
light for with 16 million colours by DMX based control. The beam
angle of the fitting shall be narrow as per the requirement.
Luminaire shall be complete with replaceable driver and capable of
operating at line voltage without any separate power supply from
100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be
suitable to operate at an ambient temperature range of -10°C to
+50°C. Lifetime of complete luminaire(LED ,Driver , Electrical &
control circuitry) shall be at least L70:50000 burning hours at
50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully
R Number marked and shall be complete with all necessary
Supplying Installation, Testing and Commissioning of Circular 40W
RGBW Facade Projector luminaire for facade lighting with Pressure
Die-cast aluminium housing, powder-coated finish, with inbuilt
driver of following wattage as given below. The luminaire bracket
shall be made of cold-rolled steel & shall be so designed that the
luminaire can be tilted to ±90°, the scale shall be provided for
rotation degrees. The luminaire shall be IP66 protection also
having silicon gasket between optical cover & LED chamber to
ensure proper IP66 protection and impact resistance of IK 07.
CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under
voltage, over voltage protection, driver inbuilt surge protection of
4KV and external surge protection (SPD) of 10 KV common
mode/differential mode, Driver Efficiency>85% . There should be
options of beam angles of 30 degree. Luminaire should have
efficacy of minimum 35 lm/W for RGBW for mono colour options.
Luminaire shall be capable of producing dynamic colour changing
light for with 16 million colours by DMX based control. The beam
angle of the fitting shall be narrow as per the requirement.
Luminaire shall be complete with replaceable driver and capable of
operating at line voltage without any separate power supply from
100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be
suitable to operate at an ambient temperature range of -10°C to
+50°C. Lifetime of complete luminaire(LED ,Driver , Electrical &
control circuitry) shall be at least L70:50000 burning hours at
50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully
R Number marked and shall be complete with all necessary
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
Non DSR NON DSR
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate DSR Amount.
Supplying Installation, Testing and Commissioning of Circular 25W
RGBW Facade Projector luminaire for facade lighting with Pressure
Die-cast aluminium housing, powder-coated finish, with inbuilt
driver of following wattage as given below. The luminaire bracket
shall be made of cold-rolled steel & shall be so designed that the
luminaire can be tilted to ±90°, the scale shall be provided for
rotation degrees. The luminaire shall be IP66 protection also
having silicon gasket between optical cover & LED chamber to
ensure proper IP66 protection and impact resistance of IK 07.
CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under
voltage, over voltage protection, driver inbuilt surge protection of
4KV and external surge protection (SPD) of 10 KV common
mode/differential mode, Driver Efficiency>85% . There should be
options of beam angles of 30 degree. Luminaire should have
efficacy of minimum 35 lm/W for RGBW for mono colour options.
Luminaire shall be capable of producing dynamic colour changing
light for with 16 million colours by DMX based control. The beam
angle of the fitting shall be narrow as per the requirement.
Luminaire shall be complete with replaceable driver and capable of
operating at line voltage without any separate power supply from
100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be
suitable to operate at an ambient temperature range of -10°C to
+50°C. Lifetime of complete luminaire(LED ,Driver , Electrical &
control circuitry) shall be at least L70:50000 burning hours at
50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully
R Number marked and shall be complete with all necessary
Supplying Installation, Testing and Commissioning of 30W LED
RGBW Wall Washer luminaire for Facade lighting with aluminium
extruded/ Die Cast housing with inbuilt driver of following wattage
as given below. The luminaire bracket shall be made of cold-rolled
steel & shall be so designed that the luminaire can be tilted to
±90°, having the rotation degrees scale shall be provided. The
luminaire shall be IP66 protection also having silicon gasket
between optical cover & LED chamber to ensure proper IP66
protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2,
under voltage, over voltage protection, driver inbuilt surge
protection of 4KV and external surge protection (SPD) of 10 KV
common mode/differential mode, Driver Efficiency>85%. There
should be options of beam angles of 10, asymmetric degree.
Luminaire should have efficacy of minimum 40 lm/W for RGBW
options. Luminaire shall be capable of producing dynamic colour
changing light for with 16 million colours by DMX based control.
The beam angle of the fitting shall be narrow as per the
requirement. Luminaire shall be complete with replaceable driver
and capable of operating at line voltage without any separate
power supply from 24 V DC. Fixture shall be suitable to operate at
an ambient temperature range of --10°C to +50°C and shall have
impact resistance of IK 07. Lifetime of complete luminaire (LED
,Driver , Electrical & control circuitry) shall be at least L70:50000
burning hours at 50°C. Luminaire shall be conforming to BIS (IS
10322) with dully R Number marked and shall be complete with all
necessary accessories required for proper working of fixture
Supplying Installation, Testing and Commissioning of LED RGBW
suitable for exterior use having IP68 rating . Flexible light strip of 5
mtr standard length with 12-15 Watt per meter. Luminaire shall be
capable of producing dynamic colour changing light for with 16
million colours by DMX based control. Minimum System lumens
450 lumens/meter and System Lumen Efficacy > 30lm/w.
Luminaire light beam spread - 100-110°, The Strip should have IP
68 protection and is offered IP 68 rated connectors to join the LED
Strips in continuity. The luminaire must be offered with Aluminium
channel for mounting the strip lights. The product should be
complete with all accessories and Driver. Lifetime of complete
5 19.4 luminaire (LED, Driver, Electrical & control circuitry) shall be at nos 150 9,689.00 14,53,350.00
least L70:50000 burning hours at 50°C. Luminaire shall be
conforming to BIS (IS 10322) with dully R Number marked.
Luminaire shall be complete with replaceable driver and capable of
operating at line voltage without any separate power supply from
24 V DC, Fixture shall be suitable to operate at an ambient
temperature range of -10°C to +50°C. The successful bidder shall
submit the following certifications/reports for approval before
supply of materials: product data sheets, LM79. report from NABL
accredited lab, illuminance diagram, polar curve & LM80 report
issued by LED manufacturer & RoHS Compliance along with CE
Digitally signed by JAYA
INTERNAL RENOVATION WORK AT BHANJA KALA MANADAP, BHUBANESWAR
Non DSR NON DSR
Sl.no. ITEM Description of Items Unit Qnty. DSR Rate DSR Amount.
Supplying Installation, Testing and Commissioning of DMX
Controller for the system including address writer and
programming the DMX controller with the suitable designs as
decided by the Engineer-in-charge/client department ( not less
than 10 nos designs) and all other accessories required for the
running of the system Controller should have Input Power 5-5.5V
DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe
should work in Stand Alone Mode and 2 universe should work in
live mode with laptop/ tablet / computer. The universe should be
expandable from 2 to 4 DMX512 universes. It should be compatible
for Programmability with PC, Mac, Tablet, Smartphone by using
USB & Ethernet. Dmx controller should have network controllability
feature to control the scene remotely through LAN and triggered
via UDP packets on port 2430. It’s must have Connections Type C
USB, XLR3, Ethernet, battery. There should be provision for
Memory microSD card. Device should have Intuitive backlit
keyboard with 10 presents and also have provision of keypad on
device for changing scene manually from device. Device should be
capable to work on Extended triggering possibilities (TCA) & also
have Smart Upgrade Technology (SUT). It is an IP 20 unit and has
an Operating Temperature of 0°C to 50°C.OS Requirements for the
controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards
should be EC, EMC, ROHS. The controller should have a variety of
features including 2048 DMX channels, clock/calendar, iPhone/iPad
/Android remote control, Ethernet facilities, dry contact port
Supplying and multi-zone
Installation, SD card
Testing andmemory. Networkof DMX Splitter
with Input Voltage range : 190-240V AC, Power Consumption 5W
max. Housing is made of CRCA with powder coated finish
Mounting, 19 inch rack mountable, Operation Temperature - 30°C
to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress
Protection Rating IP20. This unit takes the DMX Signal from DMX
7 19.6.1 Controller & split the signal into 8 separate output channels. The nos 40 6,224.00 2,48,960.00
output terminals of Splitters are optically isolated from the input.
Splitters should be capable to amplify the DMX signal & allowing
the data link to be extended by max. 300 m (1044 ft.) using AWG
22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or
maximum 20-25 fixture per output channel. To be provided with IP
enclosure if installed in external environment etc., complete as
Supplying Installation, Testing and Commissioning of DMX Cable
8 NDSR shielded 5 pin XLR aluminium + braided copper shielded FRLS mtr 3000 375.00 11,25,000.00
having 24AWG tinned copper conductor
Supplying ,installing,testing of 7W step light ,ip-66, mono colour
(warm white) for mounting in junction box arranement
Supplying and fixing of encloser ip-65 for dmx controller and
Supplying and Fixing of 5 pin XLR Male/Female connectors having
5 pole cable connector, Male/Female connector with improved
latch, cage type contacts, "solder stop" for easy soldering, and
additional ground contact for best contact integrity between chassis
and cable connector. More durable housing for maximum reliability
etc as required.
supplying , installation, testing, commisioning of Moscow linear
driver converter 150W for linear wall washer ,potted driver
supplying , installation, testing, commisioning of Moscow linear
driver converter 200W for linear wall washer ,potted driver
Supply, Installation, testing and Commissioning of Astronomical
timer panel for above façade lights
15 NDSR Commissioning and Programming of Façade lighting unit 1 7,00,000.00 7,00,000.00
SITC of Lightning Arrester complete with mast, down conductor,
earthing and accessories as required.
Digitally signed by JAYA
RENOVATION OF BHANJA KALA MANDAP, BHUBANESWAR
Sl.No Item Description (SITC Basis) Qty Unit DSR Rate NDSR Rate DSR Amount NDSR Amount
SITC of Main Line Array Speaker System – 2-way active/passive line array speaker,
1 NDSR minimum 12" LF + HF compression driver, 1000W RMS or above, coverage suitable for 32 4 Nos 3,20,000.00 12,80,000.00
m throw, rigging accessories included
SITC of Dual 18" Powered Subwoofer – minimum 2000W RMS for auditorium low
frequency reinforcement
SITC of Wall Mounted Delay/Fill Speakers – 6"–8" two-way cabinet loudspeaker,
120W–250W RMS, 90°×90° coverage or better
4 NDSR SITC of Stage Monitor Speakers – 12" monitor speaker for podium/stage foldback 1 Nos 95,000.00 95,000.00
SITC of Digital Audio Mixer – minimum 24 channel digital mixer with scene memory, Dante
SITC of Digital Signal Processor (DSP) – Dante enabled DSP with AEC, 16 input, 8 output,
feedback suppressor, delay tuning, USB conferencing
7 NDSR SITC of Power Amplifier – 4-channel Class-D amplifier 4 × 1000W or better 2 Nos 3,10,000.00 6,20,000.00
8 NDSR SITC of PTZ Camera – Full HD 60fps, 20× optical zoom, HDMI + USB + IP + PoE 2 Nos 2,80,000.00 5,60,000.00
9 NDSR SITC of Wireless Handheld Microphone – Digital UHF, rechargeable, minimum 90 channels 4 Set 1,40,000.00 5,60,000.00
10 NDSR SITC of Wireless Lapel Microphone – bodypack transmitter with lavalier mic 2 Set 1,55,000.00 3,10,000.00
11 NDSR SITC of Gooseneck Podium Microphone – 450 mm condenser gooseneck microphone 2 Nos 35,000.00 70,000.00
12 NDSR SITC of Conference Table Gooseneck Microphone with Base 8 Nos 42,000.00 3,36,000.00
13 NDSR SITC of 8/16 Port Managed PoE Network Switch 1 Nos 75,000.00 75,000.00
14 NDSR SITC of Equipment Rack – 42U rack with cooling fan, PDU and cable manager 1 Nos 90,000.00 90,000.00
15 NDSR SITC of Audio Visual Control Processor & Touch Panel 1 Set 5,40,000.00 5,40,000.00
16 NDSR SITC of Laser Projector (8000 ANSI Lumens) 1 Nos 9,60,000.00 9,60,000.00
17 NDSR SITC of 220" Motorized Projection Screen 1 Nos 4,35,000.00 4,35,000.00
18 NDSR SITC of HDMI Matrix / Switcher 1 Nos 2,45,000.00 2,45,000.00
19 NDSR SITC of CAT6 + HDMI + XLR + Speaker Cable + Connectors 1 LS 5,50,000.00 5,50,000.00
20 NDSR SITC of Installation, Programming, DSP Tuning, Testing & Commissioning 1 LS 5,50,000.00 5,50,000.00
Networking & CCTV
1 DSR 2025 39.18.1 SITC of CAT6A UTP Cable 23 AWG complete in all respect as required. 2500 Mtr 74.00 1,85,000.00
SITC of CAT6A UTP 24 port jack panel Loaded (Data/Voice)complete in all respect as
3 NDSR SITC of CAT6A UTP Information outlet jack with dust cover for Data/Voice field side. 10 Each 762.00 7,620.00
4 NDSR SITC of CAT6A UTP single port face plate complete in all respect as required. 10 Each 305.00 3,050.00
5 NDSR SITC of CAT6A UTP duplex port face plate complete in all respect as required. 10 Each 320.00 3,200.00
6 NDSR SITC of CAT6A UTP Patch Cords 1 Meter Complete in all respect as required.(Data) 20 Each 499.00 9,980.00
7 NDSR SITC of CAT6A UTP Patch Cords 2 Meter Complete in all respect as required. (Data) 20 Each 560.00 11,200.00
8 NDSR SITC of 6 Core OFC multimode 50 micron OM3 in all respect as required. 20 Mtr 217.00 4,340.00
9 NDSR SITC of pigtail LC/SC 1 Meter OM3 Complete in all respect as required. 10 Each 559.00 5,590.00
10 39.21.3 SITC of 24 port LIU loaded complete in all respect as required. 10 Each 10,049.00 1,00,490.00
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing
Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape
adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down
condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable
entry/exit provision at top and bottom with rubber protection, Front door 5mm Each 32,954.00 65,908.00
Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated
door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets
16A power distribution units, 3 numbers closed cable organizer, Hardware mounting
screws packet of 20 x 1 number, etc. complete as required.
Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing
Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side
panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely
knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos
two line cable entry/exit provision at top and bottom with rubber protection, Front door Each 21,201.00 1,48,407.00
5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or
perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6
sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware
mounting screws packet of 20 x 1 number, etc. complete as required.
SITC of 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed
14 40.11.1 SITC of 32-ch IP camera NVR, complete with License 1 Nos. 64,784.00 64,784.00
15 40.12.3 SITC of 8TB HDD for CCTV CAM 6 Nos. 20,119.00 1,20,714.00
16 42.4.3 SITC of 55" LED Display for CCTV CAM 2 Nos. 82,057.00 1,64,114.00
Digitally signed by JAYA
RENOVATION OF BHANJA KALA MANDAP, BHUBANESWAR
Sl.No Item Description (SITC Basis) Qty Unit DSR Rate NDSR Rate DSR Amount NDSR Amount
SITC of Univerge Business Communication Server Model NEC SV9100 (OR Equivalent as per
17 NDSR approved makes) Equipped with 08 Digital Extensions and 296 Analogue Extensions ( 1 Nos. 8,51,053.00 8,51,053.00
IPABX) complete with License
SITC of IP Telephone Model No. NEC ITK-24CG-1P (OR Equivalent as per approved makes)
18 NDSR with 3 line LCD display and 24 Programmable Keys with BLF ( IP Telephone) complete with 4 Nos. 22,744.00 90,976.00
SITC of Digital Telephone Model No. NEC DTK-12D-1P (OR Equivalent as per approved
19 NDSR makes) with 3 line LCD display and 12 Programmable Keys with BLF ( IP Telephone) 5 Nos. 18,342.00 91,710.00
complete with License
SITC of Digital Telephone Model No. NEC DTK-6D-1P (OR Equivalent as per approved
20 NDSR makes) with 3 line LCD display and 6 Programmable Keys with BLF ( IP Telephone) complete 10 Nos. 14,673.00 1,46,730.00
21 38.4 SITC of Analog Phones 20 Nos 1,544.00 30,880.00
22 NDSR SITC of 10GBASE-LR SFP Module. 20 Nos 14,452.00 2,89,040.00
Digitally signed by JAYA
RENOVATION OF BHANJA KALA MANDAP, BHUBANESWAR
ELECTRICAL - LIGHTNING PROTECTION SYSTEM
Sl.No Item Description (SITC Basis) Qty Unit DSR Rate NDSR Rate DSR Amount NDSR Amount
Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of
engineer in charge
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female
thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and
temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter
distance.Tested as per IEC 62561. as per direction of engineer in charge.
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with
3.00 NDSR bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 16.00 Nos. 280.00 4,480.00
meter distance. Tested as per IEC 62561.
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal
4.00 NDSR bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece 14.00 Nos. 290.00 4,060.00
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet
5.00 NDSR the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC 6.00 Nos. 1,300.00 7,800.00
62561. Tested for 100kA lightning current.
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -
6.00 NDSR 62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E- 2.00 Nos. 5,900.00 11,800.00
AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561.
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of
frost resistant concrete and clamp testedupto 100KA lightning current .
8.00 NDSR Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. 4.00 Nos. 1,500.00 6,000.00
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by
9.00 NDSR 30x3 mm GI strip as specified in drawing and directed by Engineer.Tested for 100kA 6.00 Nos. 800.00 4,800.00
lightning current.
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint
.Internal dimensions: 100x100x48 mm
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground
as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip.
Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current.
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder
13.00 NDSR bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from 10.00 Nos. 310.00 3,100.00
polyamide, black. Tested as per IEC 62561.
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width
50mm. Made of petrolatum- coated chemical fibre fabric.
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre
15.00 NDSR electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as 6.00 Nos. 7,900.00 47,400.00
per IEC 62561-2
16.00 NDSR Supply of universal clamp made of SS to connect rod with flat conductor 6.00 Nos. 1,070.00 6,420.00
Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as
per IEC 62561-7,TCLP tested
Supply of The above arrangements shall be provided with Heavy duty earth champer of
5000kg load bearing capacity to ensure the safety of earthing system
Installation of The above arrangements including all accessories as per Direction of Engg. In
Digitally signed by JAYA
BOQ FOR FIRE SAFETY (HYDRANT & SPRINKLER SYSTEM)
DSR 2025 DSR NDSR
SL.NO DESCRIPTION UOM QTY DSR Rate NDSR Rate
E&M /MR AMOUNT AMOUNT
P-2 Hydrant network- piping -
Providing, laying, testing & commissioning of 'B' class
medium duty G.I. pipe conforming to IS 1239 including
welding, fittings like elbows, tees, flanges, tapers, nuts,
bolts, gaskets etc. and fixing the pipe on the wall/ceiling -
with suitable clamp/support frame and painting with two
or more coats of synthetic enamel paint of required shade
1 complete as required
Supplying and fixing single headed internal hydrant valve
with instantaneous Stainless Steel coupling of 63 mm dia
2 27.9.2 with cast iron wheel ISI marked conforming to IS 5290 Nos 6 6,632.00 39,792.00
(Type -A) with blank Gunmetal/Stainless Steel cap and
chain as required
Supplying, fixing, testing and commissioning of butterfly
valve of PN 1.6 rating with bronze/gunmetal seat duly ISI
3 DSR marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required
27.11.6 a. 150mm Butterfly Valve Set 2 9,737.00 19,474.00
27.11.5 b. 100mm Butterfly Valve Set 1 7,271.00 7,271.00
27.11.4 c. 80mm Butterfly Valve Set 1 5,406.00 5,406.00
NDSR Supply & Installation of SS Ball Valve -
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe
with 63 mm dia male and female couplings duly bound with
GI wire, rivets etc. conforming to IS 636 (type-A) as
Supplying and fixing first-aid Hose Reel with MS
construction spray painted in post office red, conforming to
IS 884 complete with the following as required. a) 20 mm
nominal internal dia water hose thermoplastic (Textile
27.17.2 reinforced) type -2 as per IS: 12585 (b) 20 mm nominal Set 6 17,034.00 1,02,204.00
6 internal dia gun metal globe valve & nozzle. (c) Drum and
brackets for fixing the equipmets on wall. (d)Connections
from riser with 25 mm dia stop gun metal valve & M.S. Pipe
Supply & Installation of fire Hose cabinet
Supplying & fixing 63 mm dia branch pipe with 20 mm
nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose
pipe coupling as required
Supplying and fixing of fire brigade connection of cast iron
body with gun metal male instantaneous inlet couplings
8 27.19.2 complete with cap and chain as reqd. for suitable dia MS Set 1 14,820.00 14,820.00
pipe connection conforming to IS 904 as require.4 way
Providing, fixing, testing & commissioning of 15mm dia
9 27.21.1 quartzoid bulb type pendent sprinklers of rating 68 0C with Nos 30 599.00 17,970.00
required accessories
Providing, fixing, testing & commissioning of 15mm dia
10 27.21.2 quartzoid bulb type upright sprinklers of rating 68 0C with Nos 30 599.00 17,970.00
required accessories
Providing, fixing, testing & commissioning of 15mm dia
11 27.21.3 quartzoid bulb type horizontal wall sprinklers of rating 68 Nos 30 699.00 20,970.00
0C with required accessories
Digitally signed by JAYA
BOQ FOR FIRE SAFETY (HYDRANT & SPRINKLER SYSTEM)
DSR 2025 DSR NDSR
SL.NO DESCRIPTION UOM QTY DSR Rate NDSR Rate
E&M /MR AMOUNT AMOUNT
Supplying, installation, testing & commissioning of
sprinkler flexible pipe (UL Listed) of stainless steel
complete with 15 NPT on reducer thread with
maximum working pressure of 175 PSI test pressure
12 27.25 of 875 PSI (Burst) with branch line (Inlet) 25mm
NPT male thread to sprinkler head (Outlet) 15mm
NPT female thread with reducer, nipple, 2 side
brackets, center bracket, stockbar of following sizes
complete as required.
Providing, installation, testing & commissioning of
13 DSR 27.29 adjustable rosette plate for 15mm dia in white finish Nos 30 264.00 7,920.00
UL Listed or FM approved complete as required.
P-3 NDSR Other Fire Accessories ….. - -
Providing ,fixing , testing and commissioning of Portable
ABC powder type fire extinguisher 6 Kg capacity.
Providing ,fixing , testing and commissioning of Portable
Carbon-di-oxide Gas Type Fire Extinguisher 4.5 Kgs.
3 NDSR Fire bucket stand Nos 1 3,658.00 - 3,658.00
4 NDSR Fire Exit Signage Nos 10 550.00 - 5,500.00
5 NDSR Fire bucket Nos 4 750.00 - 3,000.00
Digitally signed by JAYA
RENOVATION OF BHANJA KALA MANDAP, BHUBANESWAR
BOQ FOR FIRE PUMP HOUSE
DSR 2025 DSR NDSR
SL.NO. DESCRIPTION UOM QTY DSR RATE NDSR RATE
E&M/NDSR AMOUNT AMOUNT
Hydrant Pump, piping & accessories
(a) Supplying, installation, testing and commissioning of
Electric driven Main Fire Pump conforming to IS 12469: 2019
suitable for automatic operation and consisting of following,
complete in all respects, as required : (b) Horizontal type,
multistage, centrifugal, split casing pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal as
required. (c) Suitable HP Squirrel cage induction motor, TEFC,
synchronous speed 1500 RPM, suitable for operation on 415
volts, 3 phase 50 Hz, AC supply with IP 55 protection for
enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-12615: 2018. (d) M.S. fabricated
Common base plate, coupling, coupling guard, foundation
bolts etc. as required. (e)Suitable cement concrete foundation
duly plastered with anti vibration pads.2850AT 70M HEAD
a) Supplying, installation, testing and commissioning of diesel engine
driven main fire pump conforming to IS 12469: 2019 suitable for
automatic operation and consisting of following, complete in all
respects, as required : (Diesel Driven Pump) (b) Horizontal type,
multistage, centrifugal pump of cast of iron body and bronze
impeller with stainless steel shaft, mechanical seal as required (c)
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly
2 27.2.8 insulated with 50 mm thick glass wool with 1.0 mm thick aluminium Nos 1 6,10,000.00 6,10,000.00
sheet cladding, residential silencer, instruments and protection as
per standard specification, stop solenoid for auto stop in the event
of fault with audio indications, painted with post office red colour
etc. as required. (d)M.S fabricated, common base plate, coupling,
coupling guard, foundation bolts etc. as required. (e) Suitable
cement concrete foundation duly plastered and with anti vibration
pads.1620LPM AT 70M HEAD
(a) Supplying, installation, testing and commissioning of electric
driven pressurisation pump conforming to IS 12469: 2019 suitable
for automatic operation and consisting of following, complete in all
respects, as required : (Jockey Pump) (b)Horizontal type, multistage,
centrifugal pump of cast iron body and bronze impeller with
stainless steel shaft, mechanical seal as required. (c)Suitable HP
squirell cage induction motor TEFC type suitable for operation on
3 27.3.2 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for Nos 1 98,000.00 98,000.00
enclosure, horizontal foot mounted type with Class'F' insulation,
conforming to IS-12615: 2018.(d)M.S. fabricated Common base
plate, coupling, coupling guard, foundation bolts etc. as required. (e)
Suitable cement concrete foundation duly plastered and with anti
vibration pads180LPM AT 70M HEAD
Providing, Supplying, Installation, Testing & Commissioning
4x16sqmm armoured cable for connection of Pump Set & Control
Panel including connection complete with all respect.
Digitally signed by JAYA
RENOVATION AND MODERNIZATION OF BHANJA KALA MANADAP, BHUBANESWAR
BOQ FOR FIRE PUMP HOUSE
DSR 2025 DSR NDSR
SL.NO. DESCRIPTION UOM QTY DSR RATE NDSR RATE
E&M/NDSR AMOUNT AMOUNT
Fabrication, supplying, Installation testing & commissioning of
Electrical control panel of cubical construction, floor mounted
type, fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable doors, dust and
vermin proof, powder coated of approved shade after 7 tank
treatment process, cable alley, inter-connection with suitable
size copper conductor cable/solid copper strip, having
switchgears and accessories, mountings and internal wiring,
earth terminals, numbering etc. complete in all respect,
suitable for main fire pump, pressurisation pump & diesel
pump set complete as per CPWD specification with following
in coming and Outgoings, suitable for operation on 415V, 3
phase, 50Hz Ac Supply with enclosure protection class IP 42 as
Providing, laying, testing & commissioning of 'B' class medium
duty G.I. pipe conforming to IS 1239 including welding, fittings
like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and
fixing the pipe on the wall/ceiling with suitable clamp/support
frame and painting with two or more coats of synthetic
enamel paint of required shade complete as
7 NDSR Supply & Installation 25 mm Ball Valve Nos 3 1,416.00 - 4,248.00
8 NDSR Supply & Installation 15 mm Ball Valve Nos 3 767.00 - 2,301.00
Supplying, fixing, testing and commissioning of butterfly valve
of PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required
13 Supply & Installation of Air Release Valve - -
14 NDSR a. 25mm Air Release Valve Set 2 2,183.00 - 4,366.00
Providing, installation, testing and commissioning of non-
15 DSR return valve of following sizes confirming to IS: 5312 complete -
with rubber gasket, GI bolts, nuts, washers etc.as required
Providing, installation, testing and commissioning of stainless
steel Y-strainer fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia holes with stainless steel
Supplying and fixing air vessel made of 250 mm dia, 8 mm
thick MS sheet, 1200 mm in height with air release valve on
top and flanged connection to riser, drain arrangement with
25 mm dia gun metal wheel valve with required accessories,
pressure gauge and painting with synthetic enamel paint of
approved shade as require
Providing & fixing of pressure switch in M.S. pipe line
including connection etc. as required.
Providing & fixing flow switch in following sizes M.S.
pipe including connection etc as required. 150mm dia
Digitally signed by JAYA
RENOVATION AND MODERNIZATION OF BHANJA KALA MANADAP, BHUBANESWAR
BOQ FOR FIRE ALARM SYSTEM
DSR 2025 DSR NDSR
SL.NO. DESCRIPTION UOM QTY DSR RATE NDSR Rate
E&M/NDSR AMOUNT AMOUNT
1 NDSR Providing & Fixing Beam Detector complete as required Nos 4 41,300.00 1,65,200.00
Supplying, installation, testing & commissioning of heat
detector operating at 54ºC/57ºC with rate of rise cum fixed
temperature (dual thermistor) type with mounting base
complete with all connection etc. as required.
Supplying, installation, testing & commissioning of smoke
3 28.1.2 detector with builtin LED and mounting base complete with Nos 70 1223 85,610.00
all connections etc. as required
Supplying, installation, testing & commissioning response
4 28.1.5 indicator on surface/recess MS box having two LEDs metallic Nos. 70 222 15,540.00
cover complete with all connections etc. as required
Supplying, installation, testing & commissioning of main
control and indicating panel made out of 16 SWG MS sheet to
accommodate the following items duly powder coated in
approved colour with louvers for ventilation, locking
arrangement, audio and visual indication for fire alarm and
public address system, monitoring system including
connections, interconnections etc complete as required.
6 zone panel for fire alarm system 100 watt amplifier racks
suitable for operation on 230V AC/24V DC supply conforming
to IEC-268-3 complete with
all accessories as required- 2 Nos.(one to act as standby)
Talk back master station with LED PTT (press to talk) push
button for operation on 230V AC/24 V DC supply conforming
to IEC-268 for simplex mode of operation/communication
suitable for 20 Nos.talk back unit -1 set.
Announcement control desk suitable for selection of different
zones selectively and ON ALL CALL switch with visual
indication etc., complete as required- 1 set.
Amplifier change over switch for inter changing amplifier-
Monitor panel for loudspeaker complete output selector
ON/OFF switch, fuse visual indications etc. complete as
required- 1 No.
Gooseneck microphone with stand and ON/OFF switch -1
Mains ON/OFF switch, fuse indication lamps, DC and AC
Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm
panel, central processing unit with the following loop
modules and capable of supporting not less than 240 devices
(including detectors) and minimum 120 detectors per loop
and loop length up to 2 km, network communication card,
minimum 320 character graphics/ LCD display with touch
screen or other keypad and minimum 4000 events history log
in the non volatile memory (EPROM), power supply unit (230
6 28.2.1 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed Nos. 2 250420 5,00,840.00
maintenance free batteries with automatic charger.
The panel shall have facility to connect printer to printout log
and facility to have seamless integration with analog/digital
voice evacuation system (which is part of the schedule of
work under SH: PA System) and shall be complete with all
accessories . The panel shall be compatible for IBMS system
with open protocol BACnet/ Modbus over IP complete as per
specifications.
28.2.1.2 Two Loop Panel.
Supplying, installation, testing & commissioning of
addressable manual call point complete as required.
Supplying, installation, testing & commissioning of
addressable strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter
phone jack complete as required.
Digitally signed by JAYA
RENOVATION AND MODERNIZATION OF BHANJA KALA MANADAP, BHUBANESWAR
BOQ FOR FIRE ALARM SYSTEM
DSR 2025 DSR NDSR
SL.NO. DESCRIPTION UOM QTY DSR RATE NDSR Rate
E&M/NDSR AMOUNT AMOUNT
Supplying, installation, testing & commissioning sector panel
suitable for 4 zones, complete with visual indications for
short circuit fault, open circuit fault, fire condition and all
other standard facilities as per IS:2189 with mimic diagram
for all area/zone covered, complete with all connections,
interconnections as required
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,
600/1000V rated with annealed copper conductor having
XLPE insulation, steel wire armouring & FRLS/HFFR outer
sheath complete as required
Digitally signed by JAYA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT64.pdf
Tender Document
GCC upto Amendment 04.pdf
Tender Document
SCC.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Technical Specification.pdf
Tender Document
Tender Drawings.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
Technical Circulars.pdf
Tender Document
Physical milestone.pdf
Tender Document
BoQ.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .