Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC RHODES KHANCHA CORNER RAJMAHAL ROAD RAJMAHAL ROAD RAJMAHAL ROAD VADODARA GUJARAT 390001 | VADODARA | GUJARAT | 390001 | L1 | Accepted-AOC Being L1 Bidder. | |
| 2 | L2₹1.9 Cr+₹38.4 L (24.6%)Rejected-AOC 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L2 | Rejected-AOC Being L2 Bidder. | |
| 3 | L3₹2.3 Cr+₹76.4 L (49.0%)Rejected-AOC E 104 TOP FLOOR KALKAJI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L3 | Rejected-AOC Being L3 Bidder. | |
| 4 | L4₹2.6 Cr+₹1.0 Cr (66.0%)Rejected-AOC 502 5TH FLOOR BUILDING NO 72 LAKSHMI BHAVAN NEHRU PLACE NEW DELHI 110019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-AOC Being L4 Bidder. |
| Sl No | Description | Qty | Unit | Aarham Engineers Pvt. Ltd. L3 | AIRON CORPORTION L1 | M/s. PRANAM HVAC ENGINEERING PVT. LTD. L2 | Variant Infratech Private Limited L4 |
|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing & commissioning of Floor Mounted AMCA standard Backward curved fan type Air Handling unit of following capacity with built in drive and drive package alongwith elect. Motor, AHU suitable for out door installation only. starter and cabling as per the specifications | |||||||
| 2.00Body Construction : Supporting hollow extruded heavy-duty AL with internal coving tharmal break section. 50mmthick Puf Panel with PUF insulation with density of 40 KG/Cm2. Inner skinn 22g in 120 GSM , Outer Skinn Precoated 22g, Base Frame of Unit in GSS. In Aluminum section structure. Total Unit Height not more than 2100mm | |||||||
| 3.00Fan Section : AMCA standard Backward curved fan mounted with IE1 TEFC motor with Drive Package installed on Aluminum Formed ‘C’ section with Cushy foot mount vibration pad. Fan section internally Accoustic Linned with 10 mm Open cell Insulation covered with 24 g Aluminiume perforated sheet.Fire retardant canvass connection within the units. Aluminum Aerofoil Supply air volume control Damper is part of This section | |||||||
| 4.00Cooling Coil : Cooling Coil made out from Copper tube (Plain), 0.41 mm, CopperAL fins, 0.13 mm Thickness, 11-12 FP. 4 Row Deep DX cooling Coil with Single/ Multiple Circuite. Coil Area @ 500FPM insulated S.S.Drain tray in S.S.304 Construction with 18 G. Insulated with 13mm Thick Insulation | |||||||
| 5.00Filter Section: Filter Frame in Aluminium Construction. Filter body from GI with minimum 50mm Depth. 7 ply 10 micron Filter down to 90%. Filter media Synthetic (Non woven type) HDPE washable type supported by rods. Not more than 500FPM | |||||||
| 6.00Return Air Section : Made out From hollow extruded heavy-duty AL with internal coving tharmal break section. 50mmthick Puf Panel with PUF insulation with density of 40 KG/Cm2. Inner skinn 22g in 120 GSM , Outer Skinn Precoated 22g.Base Frame of Unit in GSS Same As other section of Unit. Return Air duct connection with Aerofoil Aluminium Damper, Fresh Air Cut out with Aerofoil Aluminium Damper are part of this Section Only. | |||||||
| 7.00 | 8000 CFM @40 mm SP. Cooling Capacity 22 TR | 1 | Nos. | 5,12,450 ₹5,12,450 | 3,78,718 ₹3,78,718 Lowest | 5,65,111.27 ₹5,65,111.27 | 7,40,000 ₹7,40,000 |
| 8.00Air Cooled DX type Out Door Unit | |||||||
| 9.00Supply, installation, testing & commissioning of High COP DX Air Cooled Outdoor Condensing Unit consisting of high performance, low noise, scroll compressors, condenser coil, condenser fan, fan motor, microprocessor panel with display, wired remote controller with timed scheduler enclosed in a powder coated sheet metal casing, controlling the supplied indoor units. The unit shall have high static condenser fan. The unit shall have provision for control & monitoring from a central location with BACKNET/LANWORKS protocol, all enclosed in a powder coated sheet metal casing, supporting stand, coil protection mesh, vibration isolation pads, etc. out door unit suitable for 415V for outdoor, suitable for Double Skinned Air Handling Unit, set complete with Out door units, Refrigerant controllers, Tempraure Controler, Change over Timer, Powder Coated stands out door unit, accessories including fully charge refrigerant R410A as per specification only. | |||||||
| 10.00Supply, Installation, Testing and Comissioning of Out-door units of following capacity in suitable configurations at design conditions (110/78 deg F) including, Isolation valves, Drier, Expation Valve, Thermostat, controling devices and as per Technical specifications with Double Skinned Air Handling Unit. Net Capacity: - Unit will Deliver Capacity @ 41 Deg.C Ambient Condition with inside Condition of 25 Deg C & 50% RH. Other Requirement: - Supply, Installation, Testing and Commissioning (SITC) of LT Panel (Sl. No. 1 & 2), wall/floor mounted type, complete with suitably rated switchgears, starters and protective devices for the proper functioning of Air Cooled DX type Outdoor Units (ODUs), including interconnection with appropriate rating of power cables between LT Panel and AHUs/ODUs, provision of control cabling for signal, interlock and control between LT Panel, Air Cooled DX type ODUs & their IDUs, insulating mats conforming to IS standards at the front and rear of LT Panels, and all other accessories required for safe and reliable operation; the scope shall be comprehensive in all respects, with the clear stipulation that all required cables (both power and control) from ODUs to VRF/IDUs shall be supplied and laid by the tenderer, who must quote accordingly for each item inclusive of cabling, terminations and associated works. | |||||||
Tender Value
₹1.5 Cr
EMD Value
₹4.5 L
Closing Date
31 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
JGM(E-E)
Jt.GM(E_E), VADODARA AIRPORT
Provision of Air conditioning in new CCR room and ATC substation i/c air conditioning in Aerobridge tunnels and other ancillary work at Vadodara Airport
2026_AAI_262135_1
AAI/BO/E-E/NIT-17/AC NITB/2025-26
Open Tender
Electrical Works
Item Rate
180 days
VADODARA AIRPORT
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,180
₹4.5 L
10 Mar 2026
9 Jan 2026
2 Feb 2026
9 Jan 2026
31 Jan 2026
9 Jan 2026
9 Jan 2026 - 27 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing & commissioning of Floor Mounted AMCA standard Backward curved fan type Air Handling unit of following capacity with built in drive and drive package alongwith elect. Motor, AHU suitable for out door installation only. starter and cabling as per the specifications | - | - | - | - |
| 2 | Body Construction : Supporting hollow extruded heavy-duty AL with internal coving tharmal break section. 50mmthick Puf Panel with PUF insulation with density of 40 KG/Cm2. Inner skinn 22g in 120 GSM , Outer Skinn Precoated 22g, Base Frame of Unit in GSS. In Aluminum section structure. Total Unit Height not more than 2100mm | - | - | - | - |
| 3 | Fan Section : AMCA standard Backward curved fan mounted with IE1 TEFC motor with Drive Package installed on Aluminum Formed ‘C’ section with Cushy foot mount vibration pad. Fan section internally Accoustic Linned with 10 mm Open cell Insulation covered with 24 g Aluminiume perforated sheet.Fire retardant canvass connection within the units. Aluminum Aerofoil Supply air volume control Damper is part of This section | - | - | - | - |
| 4 | Cooling Coil : Cooling Coil made out from Copper tube (Plain), 0.41 mm, CopperAL fins, 0.13 mm Thickness, 11-12 FP. 4 Row Deep DX cooling Coil with Single/ Multiple Circuite. Coil Area @ 500FPM insulated S.S.Drain tray in S.S.304 Construction with 18 G. Insulated with 13mm Thick Insulation | - | - | - | - |
| 5 | Filter Section: Filter Frame in Aluminium Construction. Filter body from GI with minimum 50mm Depth. 7 ply 10 micron Filter down to 90%. Filter media Synthetic (Non woven type) HDPE washable type supported by rods. Not more than 500FPM | - | - | - | - |
| 6 | Return Air Section : Made out From hollow extruded heavy-duty AL with internal coving tharmal break section. 50mmthick Puf Panel with PUF insulation with density of 40 KG/Cm2. Inner skinn 22g in 120 GSM , Outer Skinn Precoated 22g.Base Frame of Unit in GSS Same As other section of Unit. Return Air duct connection with Aerofoil Aluminium Damper, Fresh Air Cut out with Aerofoil Aluminium Damper are part of this Section Only. | - | - | - | - |
| 7 | 8000 CFM @40 mm SP. Cooling Capacity 22 TR | 1 | Nos. | - | - |
| 8 | Air Cooled DX type Out Door Unit | - | - | - | - |
| 9 | Supply, installation, testing & commissioning of High COP DX Air Cooled Outdoor Condensing Unit consisting of high performance, low noise, scroll compressors, condenser coil, condenser fan, fan motor, microprocessor panel with display, wired remote controller with timed scheduler enclosed in a powder coated sheet metal casing, controlling the supplied indoor units. The unit shall have high static condenser fan. The unit shall have provision for control & monitoring from a central location with BACKNET/LANWORKS protocol, all enclosed in a powder coated sheet metal casing, supporting stand, coil protection mesh, vibration isolation pads, etc. out door unit suitable for 415V for outdoor, suitable for Double Skinned Air Handling Unit, set complete with Out door units, Refrigerant controllers, Tempraure Controler, Change over Timer, Powder Coated stands out door unit, accessories including fully charge refrigerant R410A as per specification only. | - | - | - | - |
| 10 | Supply, Installation, Testing and Comissioning of Out-door units of following capacity in suitable configurations at design conditions (110/78 deg F) including, Isolation valves, Drier, Expation Valve, Thermostat, controling devices and as per Technical specifications with Double Skinned Air Handling Unit.
Net Capacity: - Unit will Deliver Capacity @ 41 Deg.C Ambient Condition with inside Condition of 25 Deg C & 50% RH.
Other Requirement: -
Supply, Installation, Testing and Commissioning (SITC) of LT Panel (Sl. No. 1 & 2), wall/floor mounted type, complete with suitably rated switchgears, starters and protective devices for the proper functioning of Air Cooled DX type Outdoor Units (ODUs), including interconnection with appropriate rating of power cables between LT Panel and AHUs/ODUs, provision of control cabling for signal, interlock and control between LT Panel, Air Cooled DX type ODUs & their IDUs, insulating mats conforming to IS standards at the front and rear of LT Panels, and all other accessories required for safe and reliable operation; the scope shall be comprehensive in all respects, with the clear stipulation that all required cables (both power and control) from ODUs to VRF/IDUs shall be supplied and laid by the tenderer, who must quote accordingly for each item inclusive of cabling, terminations and associated works. | - | - | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.38 MB
TENDOC.pdf
Tender Documents • 10.09 MB
BOQ_304021.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .