Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.2 L+₹97,253.85 (7.35%)Rejected-AOC 114 RAJEEV GANDHI NAGAR KOTA RAJ | KOTA | KOTA | RAJASTHAN | 324005 | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.3 L+₹1.0 L (7.70%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹14.5 L+₹1.2 L (9.31%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹15.3 L+₹2.1 L (15.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Kota
HQ CWE Kota Dadwara Military Station Kota Rajasthan 324002
CWE KOTA/KOTA-45 OF 2020-21 SPECIAL REPAIR TO BLDG NO. TA-04, T-30 and T-22 AT MIL STN KOTA
2020_MES_404897_1
CWE KOTA/KOTA-45 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
KOTA
For Enlisted Contractors Class E Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
8 documents required · 8 mandatory
₹500
GE KOTA
₹40,000
Yes
25 Jan 2021
18 Dec 2020
14 Jan 2021
18 Dec 2020
12 Jan 2021
31 Dec 2020
18 Dec 2020 - 24 Dec 2020
60 days
Amount
B/R ITEMS Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and fixing new ones incl M & L for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 sqm in each pane complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal complete all as specified and directed:-
15mm bore.
20mm bore.
Dismantling of stone slabs in roofs, suspended floors, chajjas, landings etc. any thickness, jointed in any mortar & M &L for stone roof slabs, self faced 7.5cm to 10cm thick to 35cm wide, hoisted and set jointed and grouted in lime mortar 1:3 or cement mortar 1:6, complete all as specified and directed.
Dismantling of cast iron work of any description complete all as specified and directed.
Demolition of RCC/PVC over head tank capacity 1000 Ltrs & removal of all retrieved material complete all as specified and directed.
Dismatling of plain or corrugated steel shetting any guage, thickness, including Nainital or similar pattern roof covering, complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
S & F 35mm thick factory made IInd Class Hard wood (Hollock) plain framed, panelled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S & F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paid for separately
S & F 150mm overall length of cover plate floor door stopper of aluminium alloy body and tongue, bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete all as specified and directed.
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 sqm in ech pane complete all as specified and directed.
S & F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S & F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples in door and steel window complete all as specified and directed.
S & F in repairs galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples in door and steel window complete all as specified and directed.
S & F in repairs stainless steel tubular curtain rods, 25mm dia, fixed with and including decorative type end brackets, complete all as specified and directed.
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete with glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete without glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
S & F for wleded steel wire fabric (Weight per square metre N exc 4 kg) to steel members complete all as specified and directed.
M&L preparation new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chorme primer complete all as specified and directed.
M&L preparation old or previously untreated steel surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation old or previously untreated wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of 1mm thick wall care putty , complete all as specified and directed.
M&L for complete removal of existing treatment on walls, chajjas etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over over a thin layer of Birla white putty complete all as specified and directed.
M&L for preparation newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over over a thin layer of Birla white putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash on wall complete all as specified and directed.
M&L for preparation of old plastered or previously untreated surfaces of wall surfaces and apply one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered or previously untreated surfaces of ceiling and apply one coat of white wash complete all as specified and directed.
S & F150mm long mild steel barrel tower bolt stove enamelled black with bright bolt and fixed ISI marked complete all as specified and directed.
S & F 100mm size but hinges medium weight colled rolled mild steel complete all specified and directed.
S & F 150mm mild steel, bow handles, stove enamelled black anodised complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
M & L for Precast cement concrete type B0, 1:2:4 (using /1012.5 mm graded stone aggregate) as laid over roof slab after applying cement slurry for filling undulations finished even and smooth without using extra cement complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as directed. (Note : Water proofing liquid shall be measured and paid separately)
Supply only integral water proofing liquid of Dr Fixit/Sika/Fosroc complete all as specified and directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floors, surfaces finished fair and even without using extra cement and applying cement slurry over existing roof surface @ 3 kg/sqm complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid in CM 1:4 and jointed with grey cement slurry as in floors or steps tread with single piece incl chipping the steps whre reqd,with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement & pigment confirming to IS-15658-2006 of 60mm thickness M-35 grade complete all as specified and directed.
M&L 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid in CM 1:4 and jointed with grey cement slurry as in risers to steps, skirting over rendering in CM 1:4 with single piece incl chipping the steps whre reqd,with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M&L for precast (factory casted) cement Concrete kerb stone casted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with plain or interlocking joints (as directed), making groove in ground of desired dimension, placing in erect position Kerb stone in edging and set and jointed in cement mortar 1:4, making good distrubed surface of ground complete all as specified and directed.
M&L 450x300x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as directed.
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed.
M & L rednering 15mm thick in CM 1:6 on brick masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L rendering 15mm thick in CM 1:4 to stone machinery wall surfaces or on other than fair faces of brick wall surfaces finished fair and even without using extra cement for fixing tiles etc. complete all as specified and directed.
M & L for sand filling under floors or in foundation including water and consolidation, complete all as specified and directed.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
Fixing only steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
S & F 1000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
E/M PORTION Taking down the existing old unserviceable point wiring of any description for old light/fan/socket/power including terminal boards, switches, sockets, ceiling roses light fitting etc and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed.
Taking down the existing unserviceable MCB, DBs SPN with MCBs any type after disconnecting incoming and outgoing connections, complete all as specified and directed.
Taking down sub main wiring of any sizes, complete all as specified and directed.
Taking down carefully old ceiling fan/exhaust fan and refixing the same after repair, complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 1.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :-
One light/fan/bell point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet point on the same board.
Switch socket combination 5 Amps, 3 pins points on independent board.
M & L for point wiring complete for 15 Amps socket outlet on independent board with with 2.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 2.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor cable to common earth & connecting to earth dolly.
M & L switch piano flush type 5 Amps, single pole, one way, 240 Volts complete all as specified and directed.
S&F, switch socket combination, 5 Amps 240 volt 3 pin flush type universal complete all as specified and directed.
S&F, switch socket combination, 5/15 Amps 240 volt 3/5 pin flush type universal complete all as specified and directed.
S & F socket 3 pin, 5 Amps, 240 V flush type complete all as specified and directed. Make:- Havells/Plaza/Anchor)
S & F lamp holder, PVC / polycarbonate type with back plate suitable for Batten fittings complete all as specified and directed.
S & F ceiling rose, surface bakelite 65x50mm three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
S & F electronic fan regulator, stepper type, flush tpye, 200W on the existing phenolic laminated sheed complete all as specifed and directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit/casing-caping fixed on surface to wall/ ceiling by means of MS screws and saddles including one run of 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and including taking down old u/s sub main wiring complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit/casing-caping will be measured and paid as one length only.
Supply/Laying / fixing, jointing, testing and commissioning in repair under ground cable of size 25 sqmm, 3.5 core 11 KV volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete, all as specified and directed.. NOTE :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items catered in B/R part of the BOQ (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
Supply/Laying / fixing, jointing, testing and commissioning in repair under ground cable of size 16 sqmm, 2 core 11 KV volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete, all as specified and directed.. NOTE :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items catered in B/R part of the BOQ (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
Supply and fix LED tube light fitting 1x20watt basic all purpose surface and wall mounted MS batten with decorative enf cap, prewired for T8 LED tube light, including 18 Watt LED tube aluminium extruction lamp and mounting clamps etc. complete all as specified and directed. {Model/Make : Product Cat Part No LHEWB6IN1W020 of make Havells or equivalent as specified in Appendix 'D'.
Excavation in trenches n. exc 1.5 metre wide and not exceeding 1.5 m deep for foundations, n exc 10 sqm plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, back in trenches complete, all as specified and directed.
Removal of excavated surplus spoil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement.
S & F sheet metal enclosure double door DB SPN 8 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal single door DB TPN 4 way, 415 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F MCB SPN 6-40 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB SP 6-32 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB TPN 63 Amps, 415 volts, B-curve rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified and directed.
M & L brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed.
S & F of 40mm GI Pipe on wall, light grade for protection of LT cable, complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6.3 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron strip 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 50mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:3:6 type C1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note :- (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
ANNAPURNA ENTERPRISES
SINGH ENTERPRISES
Ganesh Contruction
L P Singh and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .