Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.3 CrAccepted-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹59.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹61.4 CrRejected-Finance 175 2 SOUTH STATE BANK NAGAR CHETTIPALAYAM ERODE TAMIL NADU 638002 | ERODE | TAMIL NADU | 638002 | ₹61.4 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹61.8 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹61.8 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹62.5 CrRejected-Finance | ₹62.5 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹62.7 CrRejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹62.7 Cr | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | JAIN BUILDER L3 | VIJAY CONSTRUCTIONS L5 | FUTURE ONE FACILITY MANAGEMENT L1 | CHERIAN VARKEY CONSTRUCTION CO PVT LTD L7 | CHHABINDRA KUMAR PRADHAN L6 | sambhu constriction company L4 | Ramalingam Construction Company Private Limited L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE "A" Part - I (BUILDING & STRUCTURE WORKS)
Details of prepriced schedule is given in tender documents. | 1 | Lump sum | 16,59,99,999 ₹16.6 Cr | 16,99,99,999 ₹17.0 Cr | 15,00,00,000 ₹15 Cr | 23,69,83,000 ₹23.7 Cr | 24,29,24,000 ₹24.3 Cr | 19,38,81,600 ₹19.4 Cr | 17,85,00,000 ₹17.9 Cr |
| 2.00 | SCHEDULE "A" PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 12,81,575 ₹12.8 L | 23,89,196 ₹23.9 L | 12,00,000 ₹12 L | 24,84,765 ₹24.8 L | 17,91,897.41 ₹17.9 L | 36,00,000 ₹36 L | 20,00,000 ₹20 L |
| 3.00 | SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 1,07,714 ₹1.1 L | 1,84,649 ₹1.8 L | 1,50,000 ₹1.5 L | 1,74,500 ₹1.7 L | 1,76,256.06 ₹1.8 L | 1,53,000 ₹1.5 L | 1,67,862.91 ₹1.7 L |
| 4.00 | SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 40,00,000 ₹40 L | 72,76,485 ₹72.8 L | 42,00,000 ₹42 L | 75,67,500 ₹75.7 L | 58,21,188.21 ₹58.2 L | 63,00,000 ₹63 L | 69,76,000 ₹69.8 L |
| 5.00 | SCHEDULE "A" PART-V (FIRE FIGHTING)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 90,00,000 ₹90 L | 1,37,38,881 ₹1.4 Cr | 85,00,000 ₹85 L | 1,42,88,450 ₹1.4 Cr | 1,57,99,713.15 ₹1.6 Cr | 99,00,000 ₹99 L | 1,26,98,128 ₹1.3 Cr |
| 6.00 | SCHEDULE "A" PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 1,50,00,000 ₹1.5 Cr | 2,03,33,646 ₹2.0 Cr | 1,14,13,785 ₹1.1 Cr | 2,11,46,990 ₹2.1 Cr | 1,72,83,599.87 ₹1.7 Cr | 1,62,00,000 ₹1.6 Cr | 1,60,52,000 ₹1.6 Cr |
| 7.00 | SCHEDULE "A" PART-VII (EXTERNAL WATER SUPPLY)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 5,00,000 ₹5 L | 7,85,218 ₹7.9 L | 5,00,000 ₹5 L | 7,42,390 ₹7.4 L | 6,78,143.86 ₹6.8 L | 6,30,000 ₹6.3 L | 7,13,835 ₹7.1 L |
| 8.00 | SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 50,00,000 ₹50 L | 83,85,833 ₹83.9 L | 50,00,000 ₹50 L | 87,21,270 ₹87.2 L | 79,66,542.25 ₹79.7 L | 72,00,000 ₹72 L | 89,28,279 ₹89.3 L |
| 9.00 | SCHEDULE "A" PART-IX (SEWAGE DISPOSAL)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 6,00,000 ₹6 L | 7,46,325 ₹7.5 L | 5,00,000 ₹5 L | 7,76,180 ₹7.8 L | 6,71,692.35 ₹6.7 L | 6,39,000 ₹6.4 L | 7,46,324 ₹7.5 L |
| 10.00 | SCHEDULE "A" PART-X (AREA DRAINAGE)
Details of prepriced Schedule is given in tender documents. | 1 | Lump sum | 22,00,000 ₹22 L | 31,63,639 ₹31.6 L | 21,00,000 ₹21 L | 32,90,185 ₹32.9 L | 28,47,275.65 ₹28.5 L | 27,00,000 ₹27 L | 31,63,639 ₹31.6 L |
Updated dates
Tender Value
₹70.5 Cr
EMD Value
₹15 L
Closing Date
28 Nov 2025, 6:00 pmClosed
Chief Engineer (CG) Goa
Chief Engineer (CG) Goa 403806
PROVISION OF CGSD (KOCHI) AT WILLINGDON ISLAND, KOCHI
2025_MES_735936_1
84037/E8
Open Tender
Civil Works
912 days
GE (I) (CG) Kochi
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) Kochi
₹15 L
11 Feb 2026
17 Oct 2025
5 Dec 2025
17 Oct 2025
28 Nov 2025
14 Nov 2025
Amount
SCHEDULE "A" Part - I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (ROAD/PATH/ HARD STANDING/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder.
INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extn with Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT) (Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge.
S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed
S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge.
a) 22 TR Inverter Package AC Units
b) 16.5 TR Inverter Package AC Unit
BLANK
BLANK
BLANK
Supply, Installation and Testing of Refrigerant piping with necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge.
S & F Control Cabling B/W Indoor & Outdoor units
M & L Refrigerant Gas - R410A
Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units
DUCTING Supply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge.
a) Using 0.63 mm (24 Gauge) GI sheet
b) Using 0.80 mm (22 Gauge) GI sheet
c) Using 1.00 mm (20 Gauge) GI sheet
DUCT INSULATION & LINING Supply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge.
Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge.
S & F Canvas Connection
AIR DISTRIBUTION PRODUCTS Supply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge.
S & F Collar Dampers
Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge.
Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge.
Supply and fixing, testing and commissioning water cooler having stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed.
Supply and fix refrigerator, electric driven (single phase), 220 V, 50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge.
Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of inverter technology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10)
Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5%
Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10)
AIR CONDITIONING Supply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star rating with cordless remote control, single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed.
Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5%
INTERNAL ELECTRIFICATION S & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent
S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent)
Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent)
S & F Vertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP MCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
S & F Vertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP MCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
M & L for Flame Proof MCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoing complete all as specified and as directed.
M & L for Flame Proof MCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoing complete all as specified and as directed.
Supply and fix Engage light with Green & Red LED complete all as specified and as directed
Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent
Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonate feeder pillar panel, Enystar Empty Enclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed.
M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
Supply and lay coaxial cable for TV Cable drawn through conduit
S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed.
FIRE FIGHTING Supply and fix Foot Valve conforming to IS 4038, 100 mm dia.
Supply and fix Foot Valve conforming to IS 4038, 150 mm dia.
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia.
S & F sprinkler flexible drop pipe 1 mtr long.
S & F sprinkler rossette 25 mm dia.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH
M & L for Low smoke Zero helogen flame retardent fire alarm cable 2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performance silicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed.
Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed.
S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No. 220211 Make Bajaj or equivalent to CG/Havells.
M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification
Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight 5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store)
Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed
Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed
SPECIAL EQUIPMENTS FOR STORES Design, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:- (a) Dimensions:- Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets. (b)Storage capacity:- Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mm Pallet Nos.: 480 Pallet load capacity: 1125 Kg Total capacity: 540 Tons (c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel. General technical parameters of stacker crane: Technical parameters/Type- Double Mast (i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless
(iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners (v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3 (vi) Fork unit - 1 Double deep fork (vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr (ix) The normal lifting speed (m/min) - 10 MPM (x) The normal running speed (m/min) - 65 MPM (xi) Rated load - 1125 Kg (xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor (d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station. Pallet Details:- (i) Dimensions - 1300mm(W) x 1200mm(D) (ii) Pallet height - 1250 mm (e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:- Working aisle - 01 Nos. (Double deep) Store rack - 24 Nos./Row Total rack in 1 aisle -24 (Left) + 24 (Right) = 48 Nos. No. of level - 5 Nos/Rack Total Pallet - 48 x 5 x 2 = 480 Nos. Load capacity - 1125 Kg/Level Double mast stacker crane - 01 No.
(f) Aisle Equipment:- This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level. (g) Details of rack members:- The racking system shall consist of cold-rolled steel sections as per manufacturer's design to accommodate and store pallets and connected systems. (h) Loading- unloading station/ Conveyor (i) Pallet Load 1125 Kg max. (ii) Bearing- SKF Equivalent make (iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent (iv) Gear Box- Bonfiglioli Make or equivalent (v) V.F.D.- Yashkawa make or equivalent (j) All steel surface shall be powder coated finish with 8 tank treatment process. (k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this account Note- 1) Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane. (ii) End of travel buffer for the lifting crane. (iii) Safety catches on lifting carriage. (iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure. (v) Continuous rail cleaning brush for floor rail. (vi) Adjustable rail clamp to ensure alignment.
(vii) Resilient rubber pads on adjustable clamps for vibration dampening. (viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations. (ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage. (iii) Back up circuitry for proper system operation. (iv) An electromagnetic brake shall be used to avoid the slippage of the hoist. (v) Stopper shall be provided for the maintenance door. (vi) Load cells shall be provided for the over weight of tray. (vii) Automatic door shall be provided for operator safety while machine in operating condition. Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter. (ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side. (iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided. NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor to GE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturer provided the end objective of the system is complied. 2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted 3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance Make of ASR system: Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark
Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system (i) System Height(Min) : 6400 (±100) mm (ii) System Width(Min) : 3150 (±100) mm (iii) System Depth(Min) : 2300 (±100) mm (iv) System Base(Min) : 7.24 Sq.Mtr (v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm (vi) Tray dead weight(Min) - 57 Kg (Approx.) (vii) Per tray weight capacity - 300 Kg(Min) Technical specification of the system:- (viii) Tray Quantity : 32 Nos. (ix) Usable net load - 9.6 ton(Min) (x) Storage surface area per system - 39.2 sq mtr(Min) (xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase (xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent (xiv) Chain - Diamond make or equivalent, (xv) Bearing - SKF/NTN make or equivalent (xvi) External cladding - Epoxy powder coated Safety Features: 1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer, 5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alerts Note: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system. 2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system. 3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance
Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge. Make: FAAC/Parkilo/Skidata/BFT
EXTERNAL WATER SUPPLY Supply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed.
Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed.
Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class 'F' insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By) Make:- Kirloskar Brothers/Crompton or equivalent.
Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. and comprising as under: LT Panel for Pump House. The LT Panel comprising of the following:-
Incoming:- MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 01 sets (b) Digital Multi function meter - 01 No. (c) CT's - 100/5A, CL-1, 15 VA - 01 set (d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral bar Outgoing:- (a) MCB, TPN 40 Amp, 415 Volt, 'C' Curve - 03 Nos. (b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos. (c) Digital ammeter - 2nos. (d) Single Phase Preventer - 2 nos.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed.
EXTERNAL ELECTRIFICATION M & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6" dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed. Note: HT route indicator shall be painted as under:- (i) For HT 11 KV cables - “BROWN” (ii) For LT cables - “BLUE”
Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed.
Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoor type double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Watts respectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/Technical specifications:- (a) Lifting lug for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather (j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (k) Type of connection Delta/Star (l) Type of cooling: Oil and Natural Air. (m) Vector group: DYN 11. (n) Temperature rise over an ambient of 50 °C maximum. (o) Cable end box on both side for HT/LT cables of suitable size. (p) Provision of thermometer with pocket. (q) Provision of oil and winding temperature gauge.
Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. and comprising as under: The LT Panel comprising of the following:- Main LT Panel Horizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral.
Incoming:- Incomer:- ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 Amp Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 1600/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load) (e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store) (f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room) (g) Digital Ammeter with suitable CT for each outgoing
Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg)
Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. Incoming:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 600/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor) ( d) Digital Ammeter with suitable CT for each outgoing
Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.
Incoming:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 600/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1) ( d) Digital Ammeter with suitable CT for each outgoing
Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store)
Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral. Incoming:- (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 200/5A, CL-1,15 VA - 01 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing) (c) Digital Ammeter with suitable CT for each outgoing
Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimum size 255 x 355 x 122 including suitable Cable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge.
S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLS insulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn through the poles for connection from junction box to light fitting complete etc all as specified. Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length.
Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj
Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories: Phase : 3 Phase, 415 Volts Max Load Capacity : 6 KW Timer type: Astronomical Contactor Rating : 32 A TP MCB Rating : 63 A TPN Make : Crompton/ Philips/Wipro
Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mm conforming IS 16205 (Part 24 ) for protection of electric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable)
AVIATION OBSTRUCTION LIGHT Supply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge. Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya
Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed.
ELECTRIC SIREN Supply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed.
Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hz complete all as specified and directed.
Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed.
SOLAR POWER PLANT Design, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant. (a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module: Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres.
(b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation. (c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc. (d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection. (e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed. (f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete.
DG SET Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following. (a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (b) Radiator with blower fan or heat exchanger with guard. (c) Pipe coupling for engine cooling system piping. (d ) Corrosion inhibitor coolant (e) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (f) Fly wheel housing and fly wheel to suit alternator. (g) Engine bearing mechanism in fly wheel housing. (h) Shut off coil with safeties for LLOP/HWT/over speed. (i) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows.
(l) Battery charging alternator. (m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe. (o) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (p) Interconnecting copper cabling of adequate capacity batteries control. (q ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (r) Self starter 24 volts DC. (s) Electric operated electronic governor. (t) Fuel injection pump. (u) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12vx2 nos -24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (v) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (y) Fuel tank: 12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed. (z) Isolator panel with 630 amp MCCB (aa) Auto logic panel for automatic stat (ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves (ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton. (ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (ii) Bottom gland plate for incoming and outgoing cables. (iii) Circuit diagram plate. Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016.
Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel )
Incoming:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. (c) CT's - 800/5A, CL-1,15 VA - 1 set (d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutral Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare) (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light) (e) Digital Ammeter with suitable CT for each outgoing (f) Astro Time switch for 3 phase 20A- 1 No (g) 3 Phase Power contactor 20 amps, with 230 coil
SEWAGE DISPOSAL M & L for laying of DWCPE sewage pipes line 200 mm dia bore pipe sftiffness class SN 8 including sealing of joints fittings etc complete with collers complte all as spcified and directed
M & L for laying of DWCPE sewage pipes line 150 mm dia bore pipe sftiffness class SN 8 including sealing of joints fittings etc complete with collers complte all as spcified and directed
COMPOUND WALL S & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed.
GREEN BUILDING NORMS(GRIHA CONCEPT) Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:- Type of machine: Fulley automatic in-vessel composter Composting method: 24 Hrs. Micro-organisms-based composting machine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplements Cycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415V Special features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KW Power consumption (KWH par cycle): 13-15 Length: 1650, Width: 850, Height: 1455
Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty. Note: (a) The Energy Meter to be capable of running in both prepaid and postpaid mode. (b) The meters to carry 5 year warranty. (for entire system)
Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules: (i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters. (ii) Meter Data Management Module The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter (a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cumulative energy and max demand (iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. (iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events. (v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed. (vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility. (vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods.
Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed.
Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone
Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed.
Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed.
ARBORICULTURE M & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder
All as per item No 13.121 above but pit size 60cm x 60cm x 60cm
Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months
Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months.
Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months.
Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months.
Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months.
Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months.
Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months.
Supply and planting mexican grass including providing manure as directed.
Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation) and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directed by the Engineer In Charge
M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456 using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sections complete all as specified and as shown on drg
M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456 using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
All as per item No 13.136 here-in-before but 5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed.
M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed.
Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed.
M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial load test (pull out test as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Routine load Test (Vertical load) all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all as specified and as directed
M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Initial load test (pull out test as per design load) of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Routine load Test (Vertical load) all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Ramalingam Construction Company Private Limited (BID ID -3476508)
JAIN BUILDER (BID ID -3478471)
sambhu constriction company (BID ID -3478960)
VIJAY CONSTRUCTIONS (BID ID -3478527)
CHHABINDRA KUMAR PRADHAN (BID ID -3479769)
CHERIAN VARKEY CONSTRUCTION CO PVT LTD (BID ID -3484849)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
DRG2.rar
Additional Documents • 14.93 MB
84037TENDERPAGES.pdf
Tender Documents • 2.65 MB
BOQ_824070.xls
BOQ • 0.43 MB
DRG1.rar
Additional Documents • 14.20 MB
Download all tender documents and submit your bid