Loading…
Loading…
Tender Value
₹45.0 L
EMD Value
₹45,000
Closing Date
29 Jun 2026, 6:00 pm6d left
Similar tender results from the same govt authority in the past 3 years.
Chairman And Secretary,APMC Himmatnagar
Renovation of Old Office Building at Survey No. 3523/3524
315535
01/2026-27
Open
Construction Works
Sabarkantha
4 documents required · 4 mandatory
₹1,500
Chairman Secretary APMC Himatnagar
₹45,000
19 Jun 2026
19 Jun 2026
19 Jun 2026
29 Jun 2026
19 Jun 2026
Name of Work: Renovation of Old Office Building at
Survey No. 3523/3524
PREAMBLE TO BILL OF QUANTITIES:
This is an Item rate Contract. The Items in the Bill of Quantities in this Bid Document do
not necessarily contain full descriptions of the required work and, when pricing, the Bidder
is to refer to all parts of the Bid Document i.e., the drawings, specifications etc., as also
Standards referred to, and assess the site conditions and performance requirements in
totality. The rates will be deemed to include for the full cost of work as described in the Bid
(b) Contract Price
The Prices quoted against the items in the Bill of quantities should cover the full value of
the finished work described including, but not limited to, for the cost of all the obligations
on the Bidder as set down in all the Contract Documents (which are to be read together), for
co-operation and co-ordination of his work with other Contractors, if any, working in the
area and with various Authorities, for all temporary work required and for the provision and
use of all plant, whether mechanical or non-mechanical, required for the expeditious
execution of the Works in their proper sequence, fulfilling other obligations laid down in
various clauses of this Contract Document and for shifting plant, etc. as may be required
during the progress of the Works and removing on completion and making good any
surfaces disturbed.
The rates should also include for all necessary services for the Works, for the cost of
preparing the bid, for profit and for all other establishment charges and on costs of
whatever nature, including the following:
I. Labour and all associated costs
ii. Locating and transporting construction materials.
iii. Providing at site materials and goods in accordance with the Specification.
iv. Temporary works.
v. Establishments charges, overheads and profit.
vi. Setting out of the works and liaison with all concerned authorities for approval of
vii. Ascertaining from the concerned authorities the locations to which the storm
drainage can be discharged, before commencing the project.
viii. Paying all statutory dues and taxes, housing, paying salaries and bonus etc. for
employees of the Contractor.
ix. Providing and maintaining throughout the entire construction period, safety barriers
around all excavations and making them visible during night. Providing motorable
access to the industrial units or other plots where entry is obstructed by the road
x. Obtaining permission, where necessary, to cross land, for use of public or private
land, paying compensation, if any, for damage to property or for other effects due to
the presence of the Contractor’s labourers and equipment on such land, protecting
any fencing, private or public property, repairing any damage caused by the
Contractor’s plant to public utility services (oil, water, electricity, telephone,
xi. Assistance to the Engineer as required, all reporting requirements including taking
and printing of photographs.
xii. General foreseen and unforeseen expenses of the Contractor.
Xiii. Removing all construction debris to a tip approved by the local authorities,
xiv. Any other expenses required for the execution, completion and maintenance of the
works until the final handing-over of the Works, without any exceptions or
reservations and the Contractor shall have no right to claim any compensation or
extra cost of any necessary work for the execution, completion and maintenance of
xv. Insurance charges wherever applicable both for protection of work and contractor’s
xvi. Maintaining the commissioned parts of the Works for a maintenance period as
specified in the Contract Data.
xvii. Night work wherever necessary to complete the work expeditiously and to limit
public inconveniences to the minimum.
xviii. In case, any retest at factory for any permanent material to be used in the Works,
becomes necessary to ascertain the quality of materials, the entire cost of re-
inspection and retests including cost of travel, accommodation etc. of the inspecting
official will be charged to the contractor if the retest confirms poor quality of the
xix. Providing and maintaining traffic diversion arrangements as described in the special
The cost of meeting the above mentioned obligations during the entire period of
Contract is deemed to be distributed amongst all billed items.
(c) Completion Period of Work
The Contractor is to commence the work soon as he receives the Commencement Order
and complete the work in the period indicated in the memorandum, failure to which will
attract a penalty for the delay of works, as liquidated damages, as specified in tender.
(d) Provisional Items
Provisional Item means an item included in the Contract and so designed for the execution
of work or the supply of goods, materials or services, which item may be used by the
Employer by appointing Nominated Contractors or by instructing the Main Contractor, in
whole or in part or not at all, at the discretion of the Engineer in Charge, and the Contractor
shall not have any right at any time to claim for delays or extra expenditure suffered by him
if the Provisional Items are executed only in part or not at all.
(e) Items for Which Separate Payment will not be made
The following items are to be performed as part of the Contract. The cost of these works is
deemed to be distributed in the pay items of the Contract.
i. Site Survey for establishing reference points in each road and fixing alignment of
ii. Providing and maintaining proper markers and profile rails.
iii. Supporting sides of deep excavations.
iv. Selection of materials for backfilling of trenches and against permanent structures.
v. Compacting of backfill against structures with hand held equipment’s.
vi. Testing of concrete at frequencies specified.
vii. Supplying and laying warning tapes above service lines at depths specified by the
Engineer in Charge at site.
viii. Preparing working drawings and manhole schedules in Auto CAD.
ix. Testing of materials brought at site to ensure quality.
x. Provision of safety measures at site for the works as well as the public utilities.
xi. The contractor shall provide, during the Defect Liability Period, a facility of on call
at project location in case of need, which will attend immediately and undertake the
xii. Appropriate marking and labeling of electrical machinery relating them to the
pumps and motors and instrumentation equipment’s.
xiii. All risks, liabilities and obligations set forth or implied in the tender document.
xiv. Displaying framed drawings of all electrical and mechanical equipment/single line
diagrams inside the control rooms.
xv. Mobilization and demobilization to and from site, all plant, machinery, equipment
and staff as given in the schedule of information.
xvi. Contractor's facilities as specified in Specifications.
xvii. Obtaining permission, no objection certificate/ approvals from statutory authorities.
Xviii Meeting the requirements during Defects Liability Period as explained in Special
Conditions of Contract.
Xiv Any other expense that may be incurred in fulfilling any Contractual Clause, which
is not mentioned specifically here.
General Description
This project is to be Renovation of Old Office Building at Survey No. 3523/3524
The brief overview of the project details are enlisted below
Sr. Description of Works / Buildings / Block Approximate Total Built-up
1 Renovation Work 150 SQMT
TENTATIVE SCOPE OF WORK:
Salient features of the proposed building:
Architectural description:
Composite structure of R.C.C. footing, columns ,beams and Brick masonry wall
Brickwork – Fly ash Brick masonry load bearing wall with outside and inside Plaster
Flooring: Polished kota stone flooring and glazed tiles for Bathrooms
Internal wall surfaces: Mala plaster with Plastic paint with wall putty.
External wall surfaces: Rustic Textured Finish.
Roof: RCC Slab with necessary Water Proofing
Doors/Windows: Wood Flush door, Aluminum glazed windows & Louvers.
Water supply: PVC pipes with conventional gravity system/pressurized water
Electrical works: Open/concealed electrification in conduits with LED Surface Light
Note: General Description of the Project, Scope of work and Finishes mentioned above
with drawings are indicative and variation is envisaged during detail designing. The
above information must be considered as provisional advance information to assist the
APMC HIMATNAGAR
Name of Work: Renovation of Old Office Building at
Survey No. 3523/3524
Renovation of Old Office Building at
Survey No. 3523/3524
Location : At Himmatnagar
Description Total Rate Unit Amount
Removing and scraping of old deteriorated
plaster of any thickness from wall / R.C.C
1 798.83 member including stacking of serviceable 19.92 Sqm
material and disposal of unserviceable from
site of work with all lead and lift
Demolition including stacking of
serviceable materials and
2 34.10 disposal of unserviceable materials with all 1,081.83 CUM
lead and lift. (I)
Demolition of Brick work and stone
masonry including stacking of serviceable
3 111.69 materials and disposal of unserviceable 562.84 CUM
materials with all lead and lift. (ii) In
Dismantling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
4 22.00 architraves, holdfasts and other attachment 257.48 EACH
etc. complete and stacking them within all
lead and lift.(ii) Exceeding 3 Sq.M. in area.
Add Extra for Disposing off the excavated
stuff of above items for lead up to 3.00 km.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
6 34.08 reinforcement for reinforced concrete work 6,347.96 CUM
in (C) Slabs,landing,shelves,Balconies
Lintels, Beams, Girders and Cantilever
First floor level.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
7 2.13 reinforcement for reinforced concrete work 6,389.08 CUM
in (C) Slabs,landing,shelves,Balconies
Lintels, Beams, Girders and Cantilever
Second floor level.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
8 24.14 reinforcement for reinforced concrete work 6,402.07 CUM
in (C) Slabs,landing,shelves,Balconies
Lintels, Beams, Girders and Cantilever
Ground & First floor level.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
9 2.52 reinforcement for reinforced concrete work 6,443.19 CUM
in (C) Slabs,landing,shelves,Balconies
Lintels, Beams, Girders and Cantilever
Second floor level.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete work
in (E) Staircases excluding landing up to
floor two level
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete work
in (D) Columns, Pillars posts and struts up to
floor two level.
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete work
in (D) Columns, Pillars posts and struts up to
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
reinforcement for reinforced concrete work
in (D) Columns, Pillars posts and struts up to
Providing TMT Bar FE 500D reinforcement
for R.C.C. work
14 10,602.45 including bending, binding and placing in 78.34 KG
position complete
up to floor two level
Brick work using common burnt clay
building bricks having
crushing strength not less than 35 kg.
15 79.85 /Sq.Cm. in foundation 4,568.87 CUM
and plinth in Cement Mortar 1:5. (1- Cement
sand)(B) Conventional up to Second Floor
Brick work using common burnt clay
building bricks having
crushing strength not less than 35 kg.
16 26.87 /Sq.Cm. in foundation 4,892.64 CUM
and plinth in Cement Mortar 1:5. (1- Cement
sand)(B) Conventional up to Third Floor
(i) Half brick masonry in common brunt clay
building bricks having crushing strength not
17 46.72 less than 35 Kg/Sq.Cm. in Cement mortar 684.19 Sqm
1:4 (1- Cement : 4 -coarse sand ) in
foundation and plinth (B) Conventional
Providing 20mm thick cement plaster in
single coat on single
or half brick walls for interior plastering up
18 768.87 to floor two level 235.48 Sqm
and finished even and smooth in (I) Cement
Providing 10mm thick cement plaster in
brick/concrete walls for interior plastering
19 269.74 up to floor two 138.70 Sqm
level and finished even and smooth in
(i)Cement mortar 1:3
(1-cement:3-sand)
20mm thick sand faced cement plaster on
walls up to height 10 meters above ground
level consisting of 12mm thick backing coat
of C.M. 1:3 (1-cement : 3-sand) and 8mm
thick finishing coat of C.M. 1:1 (1-cement :
1-sand) etc. complete.
Providing and fixing factory made solid core
flush door shutter of approved make
conforming to IS:2202 (Part-I), 35 mm
thick, with hardwood internal frame and
solid block board / particle board core,
finished with 1.0 mm thick decorative
laminate sheet of approved brand and shade
on both sides, including approved adhesive,
pressed in hot press, edges lipped with 1st
class teak wood / hardwood lipping 6 mm
thick, including making a vertical glass slit
of required size and fixing 5 mm thick clear
/ frosted glass with teak wood beading and
screws, complete in all respect including
necessary cutting, finishing, labour, tools &
tackles but excluding cost of fittings &
fixtures, complete as directed by Engineer-
Providing and fixing FRP frame size 125x65
thick FRP shutter with wood grain raised
panneled design
finish shutter having extra reinforcement on
sides & edges in
Gel coat finish. The core of the shutter &
frame is to be filed
up with injected polyurethene foam done in
situ along with
embedded wooden pieces for stiffening &
also taking hinges
& fintures. The whole FRP frame & shutter
proof weather proof, termite proof &
resistance to mild
acid/alkali. Rates are to be inclusive of S.S
fastener sleeve & aluminum fixtures &
Designing, Providing & Fixing Three Track
colour Anodized aluminum slide windows
having color anodized sections (of Domal
Section or Equivalent Make) as per design
.The top of the window shall be fixed with
mm thick Frosted/sand ballasted toughened
glass and at the bottom solid panel shall be
fixed . The cost is including of locking
arrangement, Roller, Bearing, 5 mm thick
Frosted/sand ballasted toughened glass with
fitting & fixture, black EPDM & transparent
silicon Sealant on outer framing, all
necessary accessories etc. complete for
window and including Mosquito Shutter
consisting of S.S.wire gauge of average
width aperature 1.4 mm with wire of dia
meter 0.63mm necessary cutting and making
good etc. for window as per detailed
drawings and instructions of an Architect/
Designing, Providing & Fixing ventilation
having colour anodized sections (of Domal
Section or Equivalent Make) fixed with
mm thick frosted glass louvers and fixed
glass window. The cost is including of
locking arrangement, fitting & fixture, black
EPDM & transparent silicon Sealant on
outer framing, all necessary accessories etc.
complete as per detailed drawings and
instructions of an Architect/ EIC.
Providing & Applying two coats of putty &
two coats of primer of
approved brand and manufacture on new
wall surface to
give an even shade including thoroughly
brushing the surface
free from mortar dropping and other foreign
sand papered smooth
Wall painting (two coats) with plastic
emulsion paint of
approved brand and manufacture on
undecorated wall
surface to give an even shade including
thoroughly brushing
the surface free from mortar droppings and
matter and sand papered smooth.
Finishing wall with weather proof exterior
emulsion paint on
wall surface (two coats) to give an required
shade after thoroughly brushing the surface
dirt, and remains of loose powdered
materials.etc complete
P & L 24" x 24" vitrified 8 mm thick tile
flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand)
on new surface or fixing on existing flooring
27 188.58 by adhesive material including dismantling 1,346.35 Sqm
of existing flooring and jointed with color
cement slurry including finished with flush
pointing & cleaning the surface etc.
complete for DARK shade
Providing and laying white glazed tiles 6mm
thick in flooring
treads of steps and landing laid on a bed of
28 16.92 12mm thick 950.53 Sqm
cement mortar 1:3 (1-cement : 3-coarse sand
) finishing with
flush pointing in white cement.
Providing and laying white glazed tiles 6mm
thick in skirting
risers of steps and dedo on 10mm thick
29 80.16 cement plaster 1:3 (1 982.03 Sqm
cement : 3-coarse sand) and jointed with
Providing and laying Granite Slab 18 mm
thick in flooring ,treads of steps and landing
laid on a bed of 12 mm thick cement mortar
30 84.84 1 :6 (1 cement :6 coarse sand) finished with 3,287.55 Sqm
flus pointing in white or colour cement With
Half Round Mould as Director by Architect
and Engineer In Charge.
Providing and fixing M.S grills or railing of
required pattern to window gapes and terrace
railing with M.S sections at required
spacing’s and frame around, square or round
bars with round headed boltsand nuts or
screws or M.S hold fast including of one
coat of primer with two coats of oil painting
Providing and lying cement based
waterproofing on roofs with a minimum
slope of 1:100 and average thickness of
mm using brickbats of appropriate size and
shape suitable to achieve the required slope
laid over 15mm thick waterproof cement
mortar 1:4 on well prepared/cleaned RC
roofs with joints between brickbats
thoroughly grouted with waterproof cement
mortar 1:4 and finished with 20 mm thick
waterproof. plaster using cement mortar 1:4
and making false squares of 300 mm size
including rounding of the junction of roof
and parapet walls for a height of 300 mmm
with brickbats nd 20mm thick waterproof
plaster and conducting necessary
leakage/dampness tests, furnishing ten years
guarantee etc. all complete as
32 241.52 directed.(waterproofing admixtures shall be 1,272.60 Sqm
of approved quality and dosage as
recommended by the manufacture -
Plastcone AW PLUS) Providing &laying
the flooring of broken china-mosaic
(Brocken pieces of china glazed tiles)white
set in 25 mm, average bed of cement mortar
1:3 with waterproofing compound to correct
level and slope(1:100) well compacted and
finished; such that minimum coverage of
china mosaic chips is about 90% of the total
area of slab. The above treatment shall
continue along the inner side of parapet or
the adjoining wall up to 30cm. height as per
the above specification... Special Agency to
be occupied and Warranty Of 10 year. 100rs
Bond paper to be submit by Contractor. and
on latter head Submitted By Executed
Providing and applying water proofing for
toilets with vertical walls of toilet and sunck
portion all inclusive(abc, IPS,grouting) with
2 coats two components acrylic polymer
modified elastomeric cementitious water
proof membrane coating (polycoat BB) on
depressed/sunken slabs which shall be
mixed as per manufacture's technical
specification, after thoroughly cleaning the
surface by mechanical means to making it
free of any loose mortar, unsound substrate,
"v" grooves cut along the construction joints,
cracks and joints of slab /wall on the
external face and same shall be filled with
polymer modified mortar (CM 1:3 mixed
with approved water proofing compound
(platcone AW Plus)in the proportion
recommended by the manufactures, cracks
in the slab (if any), pressure grouting pump
with a pressure of 3 to 4 kg/sqm, strictly
maintain the coverage specified by the
manufacture , application of 20 mm thick
plaster with water proofing compound (AW
Plus) in cement mortar 1:4 over the water
proofing treatment. Including cost. Special
Agency to be occupied
Providing & fixing 15 cm wide chicken
mesh jail with nails & then application of
mm plaster on R.C.C. & masonry joints as
per dir. of engg. In charge.
Providing throating or plaster drip and
molding to R.C.C. Chhajja.
Providing and fixing wash down water
closet (European type,W.C. Pan) with
integral P or S trap including jointing the
36 3.00 trap with soil pipe in Cement Mortar 1:1 (1- 1,356.81 No.
Cement : 1-fine sand) (Seal and cover to be
measured and paid for separately)(A)
vitreous China Pattern :(i) in white colour
Providing and fixing 12.5 Litres low level
flushing cistern with a pair, of C.I. or Mild
brackets, complete with fittings such as lead
valve less syphon, 15mm nominal size brass
with polythene float, C.P brass handle
unions and couplings for connections, with
37 3.00 inlet, outlet and overflow pipes, 40mm dia. 2,370.39 No.
porcelain enameled flush bend including
cutting holes in
walls and making good the same connecting
the flush bend with cistern and closet
(overflow pipe to be measured and paid for
separately)(A) Vitreous China (I) In white
Providing and fixing plastic seat and cover
for wash down water closer with C.P. brass
hinges and rubber buffers. (B) Black plastic
seal and cover.
C.P. Angle stop cock 15 mm Heavy duty
with cap (1 for Tank & 1 for Jet Spray)
Jet spray heavy duty with S.S. Braided hose
Providing and fixing screw down bib taps of
following size. (B) Brass chromium plated
screws down Bib Tap. (i) 15mm dia. (1 for
Bathroom & 1 for WC area).
Providing and fixing White glazed vitreous
Wall Hung Wash Basin 450x300 mm, with
necessary CI or MS brackets with
anticorrosive paint including cutting holes &
42 5.00 making good. Rate inclusive for providing & 1,000.55 No.
fixing 32 mm dia CP waste coupling, 1 nos.
CP Bib Tap 15mm NB and supporting
brackets etc. Testing & installation as per
drawing & specification.
Providing and fixing PVC AGRI. Rigid
Pipe ISI marked brand as per IS:4985 (6 kg.)
complete with including all necessary
fittings and specials such as as 45 or 90 deg.
43 6.00 bends, Tee's, Y's, clamps & hinges including 139.08 Rmt
cutting and making good the walls & ceiling
for waste pipes, connections & as directed
by the Engineer-in-Charge. (Wash out pipes
from fixture to trap) 40 mm dia.
Providing and fixing PVC SWR Nahni trap
IS 14735 for drain - 100 mm diameter with
jail of the following nominal diameter of self
cleansing design with C.I scread down or
hinged grating including the cost of cutting
and making good the walls
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for cold water supply, including all
CPVC plain & brass threaded fittings and
fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes &
45 6.00 fittings with one step CPVC solvent cement 502.78 Rmt
and the cost of cutting chases and making
good the same including testing of joints
complete as per direction of Engineer in
Charge. Concealed work, including cutting
chases and making good the walls etc. 1/2"
dia (15 mm) (Internal)
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for cold water supply, including all
CPVC plain & brass threaded fittings and
fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes &
46 20.00 fittings with one step CPVC solvent cement 746.69 Rmt
and the cost of cutting chases and making
good the same including testing of joints
complete as per direction of Engineer in
Charge. Concealed work, including cutting
chases and making good the walls etc. 1" dia
(25 mm) (Internal)
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply and all
CPVC plain & brass threaded fittings,
including fixing the pipe with clamps at
47 30.00 m spacing. This includes jointing of pipes & 523.94 Rmt
fittings with one step CPVC solvent cement
and testing of joints complete as per
direction of Engineer in Charge Internal
work - Exposed on wall 1.1/4" dia (32 mm)
Supply, installation, testing &
commissioning of brass chrome plated
isolation Threaded / flanged Ball valve /
Butterfly Valve confirming to latest IS , PN
1.6, with necessary specials, union, nipples
etc., to complete the job. 3" dia (75 mm)
Providing erecting and fixing double coated
Syntax or equivalent HDPE (ISI) mark water
49 2,000.00 tank of required capacity each with all 3.99 LTR
necessary fittings & connections etc.
completed on terrace.
Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe
erected with 6A Modular type switch / bell
push & accessories and earth continuity of
following type, erected on PVC /
Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC
pipe and accessories erected concealed in
wall/ceiling complete Cat-III
Point wiring for secondary light point with
2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper
wires, in below type of pipe to be erected
complete with earth continuity and
necessary connection with primary light
51 98.00 with accessories erected on Metal / PVC / 151.50 Point
wooden box covered with 3 mm thick PC
(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp
holder / ceiling rose / H.D.Connector as
directed.(f) with medium class Rigid PVC
pipe and accessories erected concealed in
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV Grade FRLS PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
with 6A Modular type switch and hum free
EME step type electronic fan regulator
mounted and accessories with earth
52 50.00 continuity of following type erected on PVC 629.23 Point
/ Metallic/Wooden box, single mounting
base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose /
H.D.Connector as directed.(f) with medium
class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden
box covered with appropriate front plate
modules erected on / in wall / ceiling as per
pipe erected with following type of
accessories.[I] For 6A Plug and 6 a switch
with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board(f) with medium
class Rigid PVC pipe and accessories
erected concealed in wall/ceiling
completeCat. III
Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden
54 15.00 box covered with appropriate front plate 697.91 Each
modules erected on / in wall / ceiling as per
pipe erected with following type of
accessories.[II] For 16A Plug and 16 amp
switch with 2-2.5 sq.mm Cu. Wire from
mcb db board.(f) with medium class Rigid
PVC pipe and accessories erected concealed
in wall/ceiling completeCat. III
Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden
box covered with appropriate front plate
modules erected on / in wall / ceiling as per
pipe erected with following type of
accessories.[III] For 16A Plug and 16 amp
switch with 2-4 sq.mm Cu. Wire with
sq.mm ( green) earthing wire from mcb d b
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. Blank Plate Single
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge. Modular Indicating Call
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
58 300.00 erected with necessary PVC fittings & 23.23 Mtr
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed.(A)20 mm
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
59 50.00 erected with necessary PVC fittings & 32.32 Mtr
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed.(B)25 MM
Providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated
stranded wire of green colour for earth
continuity of following size (A) with
medium class Rigid PVC pipe and
accessories (a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated
stranded wire of green colour for earth
continuity of following size (A) with
medium class Rigid PVC pipe and
accessories(B) with medium class Rigid
PVC pipe and accessories (a) 2 wire 2.5 sq.
providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
type of pipe to be erected in / on wall /
62 5.00 ceiling with 2.5 sq. mm copper conductor 107.06 Mtr.
FRLS PVC insulated stranded wire of green
colour for earth continuity of following
size.(A) with medium class Rigid PVC pipe
and accessories.(a) 2 wire 4 sq. mm
Point wiring for on board Looped Plug with
6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box,
63 20.00 single mounting base frame covered with 241.39 Point
textured / metallic/white front plate modules
erected on / in wall / ceiling with following
type accessoriesCAT-III
Supplying and erecting LED indoor fittings
with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select
any wattage capacity between the ranges
shown.) (iii) 18-
20 Watts, Surge - 2KV,IP-20, conventional
Supplying and erecting led lamps with
following wattage capacity of 220 to
voltage, minimum 15000 burning hours life,
65 40.00 500 V in built-surge 188.87 Each
protection,Polycarbonate diffuser, mounting
suitable for E14 / E27 / B22 lamp holders, pf
>= 0.5 (iii) 10 to 15 watts
Supply, Installation, Testing and
Commissioning of suitable sweep, BEE
Star rated, Ceiling fan with Brush Less
Direct Current (BLDC) permanent ferrite
magnet Motor, class of insulation: B, Rust
free 3 nos.Aluminium blades, 2 nos.
canopies, shackle kit with earthing
provision, copper winding, Power factor not
< 0.9, Service Value (CMM/W) minimum
6.85, Air delivery minimum 215 CMM,
66 27.00 RPM,230v (tolerance as per IS : 374-2019), 2,885.57 Each
THD < 10%, with remote unit for Speed
Control and all remaining accessories
including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.),
suitable for 140 to 285 Voltage and rectifier
circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply,
earthing etc. Complete as required.[ Make
shall be approved by Engineer in Charge]
(B) 1200 mm Sweep (48")
Supplying & erecting fan hook box of
mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and
67 150.00 pierced through a 16 Gauge M.S. box / 108.07 Each
Heavy Duty PVC box complete erected
concealed in Ceiling with necessary
Providing 2.5mm.thick laminated acrylic
sheet to cover the fan hook or Fan box.
Supplying & erecting approved make low
noise decorative exhaust fan having square
frame ABS body with inbuilt lowers &
square frame.250mm with 1350 RPM Cat.II
Providing & erecting 240 V MCB double
pole switch for motor & inductive load (C
70 1.00 Curve) having 10 KA breaking capacity & 330.27 Each
confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. CAT-iii
providing and erecting Approved make
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz.
having characteristic of quick action &
tripping with all advance feature & do not
incorporate any electronic component. for
following Max. rating erected as
directed.(iii) 63 Amps. DP
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996
with ISI Mark .Cat.III (1 ph DB + LDB)
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB
to house appropriate nos. of MCBs.(The
DBs should be used of same company of
MCB to be used) suitable for(A) single
phase incoming and horizontal single phase
outgoing (iv)12 way
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996
with ISI Mark .Cat.III (1 ph DB + LDB)
Providing and erecting XLPE (IS:7098)(I)-
88 ISI armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables(C)
4 core 10 Sq. mm
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
76 30.00 insulated armoured cable complete with out 38.38 Each
going tails, insulating tape etc for following
size of cables.(C) 2 to 4 core 6/10 Sq. mm
Supplying & erecting in earthpit of
minimum bore dia. 225mm size approved
make Safe Earthing Electrode consisting
Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm
having 80-200 Micron galvanising, Inner
pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of
mm with constant ohmic value surrounded
by highly conductive compound with high
charge dissipation suitable for following
type of applications with chamber and
heavy duty cover.(approved make OEM has
to submit test certificate including value of
earth resistane of installation.[C] For
Electrical Installation covering Transformer
Neutrals, Lightning arrester Earthing,
A.C.Plant & Sensitive Computer
System(like Automation, SCADA)i.e.
independent Earthing located in other
than normal soil i.e. Soft Rock, Marshy
Soil etc..-Length of Pipe : 3 Mtrs. -Back
filling Compound: 2 nos Bags of 25 Kg.
Providing and erecting required size HOT
deep Galvanised iron strip for earthing of
H.T. , OCB/ ACB/ Transformer LT panel
board, Motors etc. using proper clamp.
Providing and erecting HOT deep
Galvanised iron strip wire 8 to 16 SWG.
In words: (Rupees Fourty Four Lakh Ninty Eight thousand Seven hundred Fifty Only).
*I/We am/are willing to carry out the work at ______% above/below
the_______________________________________ _percentage ( should be written in figures and
words ) of the estimated rates mentioned above. Amount of my/our tender works out as under :*Estimated
Amt.put to: Rs.__________________ *Estimated Amt.put to Tender: Rs._________________
Tender Deduct :________% below : Rs._________________Add: % above : Rs._________________
Net Amount : Rs.___________________ Total Amount : Rs._________________
Net Amount : Rs.___________________ Total Amount : Rs._________________
(*Please strike out whichever is not applicable. )
Note 1 All work shall be carried out as per Public works department Hand book and other specifications of Division or as
Note : 2 Rates quated inclusives of clearance of site ( prior to commencement of work and at its close ) in all respects and
hold good for work under all conditions, site, moisture, whether etc
Note 3 One present labour cess will be deducted from the valued work done as per ‘Building & Other construction work
welfare cess act” G.R. No. GHR – 2005 / 04 / CWA / 2004 / 841 / M-3 Dt. 31-01-2005
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
0 Index.pdf
4 B Reference Sheet Building works- Hasalpur APMC Himatnagar.pdf
5 A Specification of Building works Hasalpur APMC Himatnagar.pdf
5 B Specifications Plumbing work.pdf
5 C Spcifications Electrical Hasalpur Himatnagar.pdf
5E GR (1).pdf
5E GR (2).pdf
5E GR (3).pdf
5E GR (4).pdf
5E GR (5).pdf
6 Special Note.pdf
Bank as Built Drawing.pdf
5E GR (6).pdf
1 NIT.pdf
2 B1 Form B1.pdf
3 Additional Instructions Hasalpur APMC Himatnagar.pdf
4 A Schedule B APMC Hasalpur Himatnagar.pdf
Download all tender documents and submit your bid