Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
26 Jun 2024, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINTENANCE, REPAIRS TO INTERNAL WIRING , FITTING, FIXTURES IN DOMESTIC AREA AT AFS BIDAR
2024_MES_656632_1
8286/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹44,000
Yes
9 Jul 2024
29 May 2024
27 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
Amount
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) complete all as specified and as directed.
Taking down existing unserviceable light fittings such as sketch type / box type / security light fittings by un screwing from boards / walls / buildings and making good disturbed surface to match with the existing complete all as specified and as directed.
Concealed point wiring with 1100V grade 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including concealed PVC 20mm dia (light duty) conduit and conduit accessories with concealed MS / PVC box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch all as specified and as directed. Note : (1) Rate quoted includes for cost of cutting chases in wall / floor / ceiling, making holes for MS / PVC box and making good to the original surfaces of any description disturbed. (2) Switch and socket shall be measured and paid for separately.
All as per item No. 03 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
All as per item No. 03 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No .03 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
Point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through and including heavy duty PVC casing capping with all accessories, surface type on wall/ roof/ floor with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sqmm multistranded PVC insulated copper conductor cable for one light point /bell point /fan point controlled by one switch complete all as specified and as directed.
All as per item No.07 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
All as per item No. 07 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No. 07 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
S & F in replacement of Switch piano flush, single pole, one way, 5/6 Amp, complete all as specified and as directed.
S & F in replacement of Switch piano flush, single pole, one way, 15 Amp, complete all as specified and as directed.
S & F in replacement of switch bell push piano, flush, single pole, 5/6 Amp,complete all as specified and as directed.
S & F in replacement of switch socket outlet 3 Pin 5 Amp, flush type, complete all as specified and as directed.
S & F in replacement of switch socket outlet multipurpose, 3 Pin 15/16 and 3pin 5/6Amp, 240 Volt, controlled by one switch complete all as specified and as directed.
S & F in replacement of switch modular type single pole one way 6 Amp with all accessories completeall as specified and as directed.
S & F in replacement of switch modular type single pole one way 16 Amp with all accessories complete all as specified and as directed.
S & F in replacement of socket outlet 3 Pin 6 Amp modular type all accessories complete all as specified and as directed.
S & F in replacement of socket outlet multipurpose 3 Pin 16A modular type with all accessories complete all as specified and as directed.
S & F in replacement of Bell push modular type 6A with all accessories complete all as specified and as directed.
S & F in replacement of ceiling rose three terminals 5 amps PVC / Polycarbonate, insulated body complete all as specified and as directed.
S & F in replacement of lamp holder, angular type, PVC / Polycarbonate with back plate 5 amps 230 V suitable for general lighting system ccomplete all as specified and as directed.
S & F in replacement of bell AC 230 Volt Ding Dong type, 240 Volt AC supply, complete all as specified and as directed.
S & F in replacement of fan regulator, AC, 230V, single pole electronic, step type, complete all as specified and as directed.
S & F in replacement of Two module, Fan regulator, step type, AC, 230V, electronic, complete all as specified and as directed.
S & F in replacement of single pole and neutral enclosure with a two pin earth plug and socket controlled by one single pole MCB 20 Amps 240 Volts complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB SP 5 to 32 Amp complete all as specified and as directed.
S & F in replacement of MCB SPN 32 Amp complete all as specified and as directed.
S & F in replacement of MCB SPN 40-63 Amp complete all as specified and as directed.
S & F in replacement of MCB TPN 16-32 Amp complete all as specified and as directed.
S & F in replacement of MCB TPN 40-100 Amp complete all as specified and as directed.
S & F in replacement of MCCB 125 Amp 4 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete all as specified and as directed.
S & F in replacement of MCCB 100 Amp 4 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete all as specified and as directed.
S & F in replacement of MCCB 63 Amp 4 pole 16 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete all as specified and as directed.
S & F 20/22 W LED Surface mounted, batten fixture, 1200mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink. The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K complete all as specified and as directed.
S & F 10/12 W LED Surface mounted, batten fixture 600 mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink . The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K complete all as specified and as directed.
Supply, fix, test and commissioning 70 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as specified and as directed.
Supply, fix, test and commissioning 35 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as specified and as directed.
S & F 35/36 W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 2ft X 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K complete all as specified and as directed.
S & F 40 W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 2ft X 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K complete all as specified and as directed.
Sub main wiring with 2 runs of 4 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 4 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 6 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 6 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 10 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 10 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
S & F in replacement of switch socket combination flush type universal 2 in 1, 3 pin 5 amps 230 volts complete all as specified and as directed.
S & F in replacement of switch socket combination flush type universal 2 in 1, 3 pin 15 amps 230 volts complete all as specified and as directed.
S & F in replacement of modular switch socket combination 3 module , 3 pin 5 amps 230 volts complete all as specified and as directed.
S & F in replacement of modular switch socket combination 3 module , 6 pin 16 amps , 230 volts complete all as specified and as directed.
S & F in replacement of modular white cover plate with frame, 2 module complete all as specified and as directed.
S & F in replacement of modular white cover plate with frame, 3 module complete all as specified and as directed.
S & F in replacement of modular white cover plate with frame, 4 module complete all as specified and as directed.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits pertains to installations/ buildings and M/L for providing earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth strip of 25x4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with 50mm thick with 6mm dia MS bars as shown in SSR Pt - 1 electrical plate No 3 complete all as specified and as directed. Note: Quoted rate deemed to include the cost or excavation and earth work PCC chamber, funnel cover etc
Dismantling unserviceable corroded building security light bracket and S&F Street light bracket made out of 40mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 32 x 6mm (2 Nos) with suitable nut, bolts and washers to steel tubular / concrete poles complete all as specified and directed
Mr Madhusudhan Kotarki
famous construction
RAMESH CONSTRUCTION COMPANY
RAMESHWAR SWAMI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .