Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-Finance | L1 | Accepted-Finance Financially qualify |
| Sl No | Description | Qty | Unit | GOUTAM ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00 | Supply & Installation of Cold Well - II, 150 mm thick PUF Panels for wall and ceiling having 0.45 mm TCT PPGI on both sides, PUF density 40 + 2 kg/m3 with all accessories and fixtures | 42 | Sqm | 3,351 ₹1,40,742 Lowest |
| 2.00 | Supply & Installation of Cold Well - II, 120 mm thick PUF Panels for wall and ceiling having 0.45 mm TCT PPGI on both sides, PUF density 40 + 2 kg/m3 | 57 | Sqm | 3,057 ₹1,74,249 Lowest |
| 3.00 | Supply & Installation of 150 mm PUF Slab PUF density 40 + 2 kg/m3 with TARFELT LAYER & BITUMEN LAYER as per requirement | 6 | Sqm | 2,469 ₹14,814 Lowest |
| 4.00 | Supply & Installation of 120 mm PUF Slab PUF density 40 + 2 kg/m3 TARFELT LAYER & BITUMEN LAYER as per requirement | 14 | Sqm | 2,234 ₹31,276 Lowest |
| 5.00 | COMPRESSOR & CONDENSING UNIT INSTALLATION
for Blast Freezer -
Evaporation Temp. : (-41) Deg. C
- Condensing Temp. : 50 Deg. C
- Refrigerant : R-404A Including Installation, Testing & Commissioning | 1 | Nos | 4,70,254 ₹4,70,254 Lowest |
| 6.00 | COMPRESSOR & CONDENSING UNIT INSTALLATION
for Cold Room -
Evaporation Temp. : (-30) Deg. C
- Condensing Temp. : 50 Deg. C
- Refrigerant : R-404A Including Installation, Testing & Commissioning | 1 | Nos | 2,11,614 ₹2,11,614 Lowest |
| 7.00 | Evaporator for Blast Freezer - Evaporation Temp. : (-40) Deg. C
- Condensing Temp. : 50 Deg. C
- Refrigerant : R-404A Including Installation, Testing & Commissioning | 1 | Nos | 1,76,345 ₹1,76,345 Lowest |
| 8.00 | Evaporator for Cold Room
- Evaporation Temp. : (-30) Deg. C
- Condensing Temp. : 50 Deg. C
- Refrigerant : R-404A Including Installation, Testing & Commissioning | 1 | Nos | 70,538 ₹70,538 Lowest |
| 9.00 | Installation, Testing & Commissioning | 2 | Nos | 41,147 ₹82,294 Lowest |
| 10.00 | Flake Ice Machine- 1 (one) ton per day Ice production, PLC based, Continuous operation with water level alarm, Refrigerant Pressure High & Low Alarm. | 1 | Unit | 7,05,380 ₹7,05,380 Lowest |
Tender Value
₹53.7 L
EMD Value
₹1.1 L
Closing Date
18 Dec 2025, 12:00 pmClosed
GM(T)
UKKUVB, Rudrapur
S.I.T.C for Mini Fish Processing Unit at Naini Saini (Pithoragarh)
2025_UAPMB_89734_1
e-nivida-719/2025
Open Tender
Electrical Works
Item Rate
360 days
Naini Saini (Pithoragarh)
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
GM(T), UKKUVB, Rudrapur
₹1.1 L
20 Dec 2025
10 Dec 2025
18 Dec 2025
10 Dec 2025
18 Dec 2025
10 Dec 2025
Amount
Supply & Installation of Cold Well - II, 150 mm thick PUF Panels for wall and ceiling having 0.45 mm TCT PPGI on both sides, PUF density 40 + 2 kg/m3 with all accessories and fixtures
Supply & Installation of Cold Well - II, 120 mm thick PUF Panels for wall and ceiling having 0.45 mm TCT PPGI on both sides, PUF density 40 + 2 kg/m3
Supply & Installation of 150 mm PUF Slab PUF density 40 + 2 kg/m3 with TARFELT LAYER & BITUMEN LAYER as per requirement
Supply & Installation of 120 mm PUF Slab PUF density 40 + 2 kg/m3 TARFELT LAYER & BITUMEN LAYER as per requirement
COMPRESSOR & CONDENSING UNIT INSTALLATION for Blast Freezer - Evaporation Temp. : (-41) Deg. C - Condensing Temp. : 50 Deg. C - Refrigerant : R-404A Including Installation, Testing & Commissioning
COMPRESSOR & CONDENSING UNIT INSTALLATION for Cold Room - Evaporation Temp. : (-30) Deg. C - Condensing Temp. : 50 Deg. C - Refrigerant : R-404A Including Installation, Testing & Commissioning
Evaporator for Blast Freezer - Evaporation Temp. : (-40) Deg. C - Condensing Temp. : 50 Deg. C - Refrigerant : R-404A Including Installation, Testing & Commissioning
Evaporator for Cold Room - Evaporation Temp. : (-30) Deg. C - Condensing Temp. : 50 Deg. C - Refrigerant : R-404A Including Installation, Testing & Commissioning
Installation, Testing & Commissioning
Flake Ice Machine- 1 (one) ton per day Ice production, PLC based, Continuous operation with water level alarm, Refrigerant Pressure High & Low Alarm.
150 mm (PUF density 40 + 2 kg/m3 with all accessories and fixtures) Swing Door with installation (1 X 2.1m)
120 mm (PUF density 40 + 2 kg/m3 with all accessories and fixtures)Swing Door with installation 1.0x2.1m & 1.2X2.1m)
AC- 2 Tonnes for Processing Hall(Supply & Erection)
Stainless Steel (SS 304)Processing table (6'X3'X3'), Table top 1 mm SS 304 sheet on 40 mm square frame with cross support 3 numbers with 50mm centre partition and 40 mm square section leg (six number) with antiskid footcap
Jumbo Insulated Ice box 310 Litres - durable polyethylene (PE) with insulation of polyruethane (PU, UV-stabilized)
Crates 48 Ltr 540x360x300 mm Plastic Multi- Purpose
Perforated Crates (500x300x300mm) Plastic Multi- Purpose
Stainless steel shovel (5") with wooden handle
Fish Cutting knife
Supply and installation of mono block pump Pumps (0.5 hp) with all accessories
BlastFreezer 300 KG/HR
Ice Box 3 KG
Raw fish handling unit cleanng and washing including pressure washing units
Fish cutting Knife
Logistics, erection & commisioning
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_106376.xls
BOQ • 0.32 MB
doc.pdf
Tender Documents • 11.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .