Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-Finance MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | ₹19.4 L | L1 | Accepted-Finance Technically qualified |
| 2 | L2₹22.4 L+₹3.0 L (15.7%)Accepted-Finance | ₹22.4 L+₹3.0 L (15.7%) | L2 | Accepted-Finance Technically qualified |
| 3 | L3₹22.9 L+₹3.5 L (18.2%)Accepted-Finance | ₹22.9 L+₹3.5 L (18.2%) | L3 | Accepted-Finance Technically qualified |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹18.1 L
EMD Value
₹34,700
Closing Date
23 Jul 2020, 5:00 pmClosed
Executive Engineer
Elect. Division HPPWD Palampur
Construction of Mini Secretariat (Combined Office) building at Nagrota Bagwan in Distt. Kangra, HP (Providing Electrical Control Panels, Sub Main wiring, Ceiling Fans and LED Luminaires therein).
2020_PWD_38761_4
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
60 days
Nagrota Bagwan in Distt. Kangra
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Executive Engineer
₹34,700
9 Sept 2020
8 Jul 2020
24 Jul 2020
8 Jul 2020
23 Jul 2020
8 Jul 2020
Amount
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying, Installation, Testing and Commissioning of indoor s/door, Cubical type L.T. metering panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 700A TP&N Copper Busbar ( Vertical) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc. and the panel should be approved/ tested from CPRI lab and should conforming to IS 64139.
MATERIAL:
OUTGOING :
Space for KWH Meter Single Phase- 4 Nos, MCB 63 A DP 10 KA- 1 No, MCB 32 Amp DP 10 KA- 3 Nos, Space for KWH Meter Three Phase - 6 Nos, Space for current transformer 3 Nos- 6 Nos, MCCB 100 A 3P 25 kA with O/L & S/C Protection 1 No., Spreader Link 100A 3P- 1 Nos., RHOM Ext. 1 No , MCCB 160A 3P 25 kA TMR with O/L & S/C Protection 1 No, Spreader Link 160 A 3P -1 No, RHOM Ext. 1 No, MCCB 63 A 3P 25 kA TMR with O/L & S/C Protection 4 No, Spreader Link 63 A 3P- 4 Nos, RHOM Ext. 4 Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass, wooden, copper flexible door earth, legend plates etc.
Makes for MCCB : Schneider/L&T/ABB .
Supplying, Installation, Testing and Commissioning of indoor s/door, Cubical type L.T. metering panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 700A TP&N Copper Busbar ( Vertical) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc. and the panel should be approved/ tested from CPRI lab and should conforming to IS 64139.
MATERIAL:
OUTGOING :
MCCB 63 A 3P 25 KA TMR with O/L & S/C Protection 2 Nos., Spreader Link for MCCB 63A 3P- 2 Nos., RHOM Ext. 2 Nos, MCCB 40 A 3P 25 kA TMR with O/L & S/C Protection 2 Nos, Spreader Link for MCCB 63 A 3P- 2 Nos, RHOM Ext. 2 Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass, wooden, copper flexible door earth, legend plates etc.
Makes for MCCB : Schneider/L&T/ABB .
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 25 sq. mm (3.5 core)
Providing, Installation, testing and commissioning of ceiling fan with modular step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep, Category-A
Ceiling Fan 1400 mm sweep, Category-A
Makes:- Bajaj(Ultima) ,Usha,Crompton
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.
Exhaust Fan, Light duty, (Domestic) 300 mm sweep.
Exhaust Fan, Heavy duty, 300 mm sweep.
Makes:- Bajaj / Usha / Crompton
Providing, Installation, testing and commissioning of wall cabin fan complete with connections, testing and commissioning etc. as required complete in all respects.
Makes:- Havells(cierra cabin fan ) / Bajaj/Usha,crompton
Providing and fixing indoor decorative aluminium extruded LED Tube fixture of following rating and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED tube fixture 36 watt, 4 feet long.
Makes:- Philips/Wipro/Bajaj/Anchor by Panasonic
Supplying & fixing following type of surface mounted LED downlighter, white power coated CRCA housing diffusser to avoid glaire, it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED surface mounted square downlighter 20 watt.
Makes:- Philips/Wipro/Bajaj/Anchor by Panasonic
Providing and fixing surface mounting LED luminaire of following rating with powder coated CRCA housing with high power LED, diffusser to avoid glaire, it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED 40 watt, 4'x1' feet long LED
Makes:- Philips/Wipro/Bajaj/ Anchor by Panasonic
Providing and fixing surface mounting LED luminaire of following rating with powder coated CRCA housing with high power LEDs, diffusser to avoid glaire, it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED 24 watt surface mounted square LED Luminaire (1'x1')
Makes:- Philips/Wipro/Bajaj/Anchor by Panasonic
Providing and fixing LED Bulk head of following rating and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Bulk head fitting 10 watt
Makes:- Philips/Wipro/Bajaj/Anchor by Panasonic
Extra for fixing the louvers/shutters complete with frame for exhaust fans of all sizes as required:-
Providing and fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required.
63 Amp. Category-A
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board/PPI including drilling holes in the cubical panel, making connections, etc. as required.
40/63/100 Amps. 16 KA
JAMWAL ELECTRICAL WORKS
Rajesh Kumar Jaswal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .