| 1.00 | SITC of 2.0 TR split Air Conditioner with all accessories and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and having Air Flow Rate >=590 cfm with minimum 3 star rating and of reputed make along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 1 | nos | 0 ₹62,000 | 0 ₹61,950 Lowest |
| 2.00 | SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek /V guard along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour and all types of taxes etc | 1 | nos | 0 ₹9,000 Lowest | 0 ₹9,000 Lowest |
| 3.00 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 10 sq mm 3 core ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting Stablizers to the electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges | 40 | MTRS | 0 ₹8,000 | 0 ₹7,920 Lowest |
| 4.00 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stablizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including PVC pipes 1”, clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and ta | 40 | MTRS | 0 ₹3,200 | 0 ₹3,160 Lowest |
| 5.00 | Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc., labour charges, transportation charges and all other charges and taxes. | 20 | FT | 0 ₹10,000 Lowest | 0 ₹10,000 Lowest |
| 6.00 | Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. The job includes Providing and Fitting of SPN 40 Amp Box type -02 No’s and outer unit stands -02 No’s Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax | 1 | JOB | 0 ₹1,500 | 0 ₹1,470 Lowest |
| 7.00 | Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz
Compressor 2 TR
The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. | 1 | nos | 0.02 ₹11,760 Lowest | 0.02 ₹11,760 Lowest |
| 7.10 | Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz
Condenser Coil 2 TR
The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. | 1 | nos | 0.02 ₹9,800 Lowest | 0.02 ₹9,800 Lowest |
| 7.20 | Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz
Refrigerant gas R-410
The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. | 2.5 | KG | 0.02 ₹2,450 | 0.02 ₹2,445.1 Lowest |
| 7.30 | Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz
Servicing
The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. | 1 | JOB | 0.02 ₹901.6 | 0.02 ₹882 Lowest |
Tender Value
₹1.2 L
EMD Value
₹3,000
Closing Date
29 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Providing and Fitting of Split AC 02 TR Capacity 01 No to be installed in the Room No 4, Emergency wing and other allied works at GMCH Jammu
2026_PWDJK_310191_1
MHDJ/e-NIT 49 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹3,000
13 Jul 2026
18 May 2026
30 May 2026
18 May 2026
29 May 2026
23 May 2026
18 May 2026 - 29 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Providing and Fitting of Split AC – 02 TR Capacity – 01 No to be installed in the Room No 4, Emergency wing and other allied works at GMCH Jammu.
MHDJ/e-NIT 49 of 2026-27 Dated: 18.05.2026 Due : 29.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 SITC of 2.0 TR split Air Conditioner with all accessories and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and having Air Flow Rate >=590 cfm with minimum 3 star rating and of reputed make along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. 1 nos Excess(+) Full Conversion INR
2 SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek /V guard along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour and all types of taxes etc 1 nos Excess(+) Full Conversion INR
3 Providing and laying (using conduits and wire fasteners / cable clips) ) of 10 sq mm 3 core ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting Stablizers to the electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges 40 MTRS Excess(+) Full Conversion INR
4 Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stablizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including PVC pipes 1”, clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and ta 40 MTRS Excess(+) Full Conversion INR
5 Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc., labour charges, transportation charges and all other charges and taxes. 20 FT Excess(+) Full Conversion INR
6 Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. The job includes Providing and Fitting of SPN 40 Amp Box type -02 No’s and outer unit stands -02 No’s Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax 1 JOB Excess(+) Full Conversion INR
7 Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz Compressor 2 TR The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. 1 nos Excess(+) Full Conversion INR
7.1 Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz Condenser Coil 2 TR The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. 1 nos Excess(+) Full Conversion INR
7.2 Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz Refrigerant gas R-410 The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. 2.5 KG Excess(+) Full Conversion INR
7.3 Repairs of 01 No Split Air Conditioners 2 TR capacity installed at in the Room No 4, Emergency wing of GMCH, Jammu by way of Removing them from their installed positions and then servicing/repairing and installing them at their orignal location .The job includes dismantling the old damaged parts and providing and fitting of new parts viz Servicing The job includes skilled man power charges, labour charges, material handling charges, specialized tool and tackle charges and all the taxes thereof. 1 JOB Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_1003742.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .