Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-Finance | ₹2.8 Cr | L1 | Accepted-Finance Bid found technically responsive and quoted lowest evaluated amount hence accepted as L1 bidder. |
| 2 | L2₹2.8 CrRejected-Finance | ₹2.8 Cr | L2 | Rejected-Finance Bid found technically responsive but quoted amount is higher than L1 bidder hence ranked as L2. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Bid unqalified |
| Sl No | Description | Qty | Unit | National Construction L2 | M/S SHRISAI CONSTRUCTION CO L1 |
|---|---|---|---|---|---|
| 1.00 | Cleaning Jungle including uprooting of rank vegetation, Grass, trush wood, trees and sapling of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to distance of outside the periphery of the area cleared. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 38,013.27 | sqm. | 1.95 ₹74,125.88 | 1 ₹38,013.27 |
| 2.00 | Provision to lift and cart off site exisiting paving/ rubble/ flower bed edging
Provision for thinning out of existing vegetation and removal of unwanted vegetation in existing soft landscaped areas including planted zones to be rehabilitated
"Removal /R | 38,013.27 | sqm. | 24 ₹9.1 L | 23 ₹8.7 L |
| 3.00 | Site leveling involves preparing a construction site by creating a flat, even surface through adjusting the natural slope or unevenness of the land, ensuring a stable foundation and proper drainage by HWH computerized levelling by mechanical device i.e. Tractor 35 HP with cultivator/ harrow and leveler etc. (20 hrs./ acre or by manual labour). (site area is 38,013.27) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 480 | Hours | 287 ₹1.4 L | 281 ₹1.3 L |
| 4.00 | Rough dressing the trenched/Ground including breaking clods. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 38,013.27 | sqm. | 1.95 ₹74,125.88 | 1 ₹38,013.27 |
| 5.00 | Fine dressing of the ground all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 62,136.27 | sqm. | 4.63 ₹2.9 L | 4 ₹2.5 L |
| 6.00 | Provision for Fertilizers
Mixing earth and sludge or manure in the requred proportion specified or directed by the office- in - charge.(24123SqmX75mm) | 1,809.23 | Cum. | 49.17 ₹88,959.84 | 48.5 ₹87,747.66 |
| 7.00 | Spreading of sludge, dump manure and/or good earth in required requred
thickness as per direction of office- in - charge (Cost of sludge, dump manure and/or good earth to be paid separatley).(24123SqmX75mm) | 1,809.23 | Cum. | 70.43 ₹1.3 L | 70 ₹1.3 L |
| 8.00 | Digging for plant and tree
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately), Holes 60 cm dia, and 60 cm deep | 18,750 | No. | 22 ₹4.1 L | 21.5 ₹4.0 L |
| 9.00 | Providing and stacking of Azadirachta indica (NEEM) of height
180-210 cm in big polybag of size 25 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 36 | No. | 300 ₹10,800 | 295 ₹10,620 |
| 10.00 | Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm in big polybag of size25 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. | 56 | No. | 140 ₹7,840 | 138 ₹7,728 |
Tender Value
₹2.9 Cr
EMD Value
₹5.7 L
Closing Date
2 Feb 2026, 3:00 pmClosed
Vice Chairman
DLDA U.S Nagar
Development and Renovation Of Ring Park Uttarayani Park At Village Kalyanpur Rudrapur Distt Udham Singh Nagar
2026_UHUDA_90931_1
734/USN-0670/2026
Open Tender
Civil Works - Others
Rudrapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
Secretary
₹5.7 L
Yes
DLDA U.S Nagar
25 May 2026
13 Jan 2026
6 Feb 2026
13 Jan 2026
2 Feb 2026
21 Jan 2026
17 Jan 2026
Cleaning Jungle including uprooting of rank vegetation, Grass, trush wood, trees and sapling of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to distance of outside the periphery of the area cleared. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Provision to lift and cart off site exisiting paving/ rubble/ flower bed edging Provision for thinning out of existing vegetation and removal of unwanted vegetation in existing soft landscaped areas including planted zones to be rehabilitated "Removal /R
Site leveling involves preparing a construction site by creating a flat, even surface through adjusting the natural slope or unevenness of the land, ensuring a stable foundation and proper drainage by HWH computerized levelling by mechanical device i.e. Tractor 35 HP with cultivator/ harrow and leveler etc. (20 hrs./ acre or by manual labour). (site area is 38,013.27) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Rough dressing the trenched/Ground including breaking clods. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Fine dressing of the ground all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Provision for Fertilizers Mixing earth and sludge or manure in the requred proportion specified or directed by the office- in - charge.(24123SqmX75mm)
Spreading of sludge, dump manure and/or good earth in required requred thickness as per direction of office- in - charge (Cost of sludge, dump manure and/or good earth to be paid separatley).(24123SqmX75mm)
Digging for plant and tree Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately), Holes 60 cm dia, and 60 cm deep
Providing and stacking of Azadirachta indica (NEEM) of height 180-210 cm in big polybag of size 25 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm in big polybag of size25 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm in big polybag of size25 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Trees Providing and stacking of Calliandra, height 180cm-240cm in earthen pot of size 30cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Plumeria alba of height 210cm-240 cm in earthen pot of size 30cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Lagerstroemia indiaca of height 90-105 cm in earthen pot of size 30cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Plant Providing and stacking of Hibiscus of height 40-50 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Volkameria inermis of height 40 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Red Rose plant of height 40-60 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Jasmine plant of height 40-60 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Lily plant of height 45 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Orchids plant of height 40-50 cm all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Shrubs & Hedge Putranjiva hedge of height 50 cm-90cm. with 3-4 branches and healthy foliage in polybag of size 20 cm. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Ficus panda of height 60-75 cm. with 3-4 branches and healthy foliage in polybag of size 20 cm. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Creepers Providing and stacking of Madhumalti Creeper plant all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Rangoon Creeper plant all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Clerodendrum thomsoniae creeper plant all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Herbal plant Providing and stacking of Genus Mentha (Mint) Plant all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of kumari (aloe vera) plant of all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Lemongrass Plant of height all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and stacking of Ocimum (Tulasi) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install (200 x 100 x 50mm) Interlocking block 50mm thick Paver, herringbone/other as per architect. Allow for compaction, 25mm compacted sand and agreed final levels. Location-parking area all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install (size as/avilabilty) stone 50mm thick. Allow for compaction, 25mm compacted sand and agreed final levels. Location- In all small garden all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install (200 x 100 x 50mm) Grass interlocking concrete paver 50mm thick Paver, herringbone/other as per architect. Allow for compaction, 25mm compacted sand and agreed final levels. Location-Triangular grass area all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install (150 x 300 x 450 mm) pathway vertical paver 50mm thick Paver, herringbone/other as per architect. Allow for compaction, 25mm compacted sand and agreed final levels. Location- Around Triangular grass area all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install Pebble stone on bidum geotextile and gravel fix (to later detail) Bidum to be included in price. (1 tom for 25 sqmt) Location- Entry Gate (1 To 4) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver & install (2000mm x 600mm x 50mm) gravel stone/Red stone/ Rectangular stone 50mm thick as per architect and architectural dwg. Location-Garden pathway all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Provision to deliver, supply and install 1000 x 125 x 1.6mm Perma- edge galvanized steel edging, dark brown, or similar approved, between planted areas and gravel areas as indicated on plan including architect and as per architectural dwg. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Provision to deliver, supply and install 200 mm average depth of sand for sandpit, specification as per architectural dwg.all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing for a pathway constructed with mud base, with upper finish 25 mm to 50 mm thick Moram. Location- Outer Jogging Track & Location- Inner Jogging Track all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PUMPING UNIT Supply, compelete Installation, Testing & Commissioning of Pump/Borewell submersible water pump. Submersible motor pupm CRI Make 5 Hp Transportation Charge for boring including cartage loading Unloading for all required material M.s.Pipe T & P equipment material etc. to the site of work . To Contractor Scope (to & Fro ) Carriage By Tractor Trolly Or Dunlop Cart Etc "Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1.1 300 mm dia " Supply of falt all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge. electrical cable three core 4.00 Sq mm 3 Core plaza / Finolex make ISI mark.
WATER PIPE LINE & ACCESSORIES Supply of HDPE/PVC Pipe 6Kg/Cum2 Pressure with required PVC standard special confirming to IS:4985-2000 With latest amendment Make- Finolex Industries Ltd./Kisan/ Superelndustries Ltd (Rate as Per Comparative Statement per Rm.) 140 mm Dia with coupler @ 6 Kgf/Cm2 Pressure. (As/requerment)
Supply of HDPE Pipe Grade PE-100 , Class -4 (PN-8) with required HDPE Standard Special confirming to IS :14333/1996 and IS : 4985-2000 with latest amendment Make – Trupati Structural Ltd / Sudhakar Market Agencies Pvt Ltd Hindushtan Pipe Sales Corporation ( Rate as Per Comperative Statementy Per Rm.) 63 mm Dia PE-100 , PN-8
VALVES & ACCESSORIES Supply, compelete Installation, Testing & Commissioning of 4"/110mm Cast Iron Sluice/Gate valve with pressure rating PN 10 complete with matching flanges, gasket, nut bolt and other fittings and accessories.
Supply, Installation, Testing & Commissioning of PVC Double Union Ball Valve, security pivot to maintain lever in space, double water tight joint, direct injection stem, Stem O- Ring, non mechanical, ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 2"/63mm with pressure rating PN 10 complete with all fittings.
Supply, Installation, Testing & Commissioning of a double acting air cum vaccum release valve of size 2". The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be PN10 complete with all fittings. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
FILTRATION UNIT Supply, Installation, Testing & Commissioning of Disc Filter 2" (20 m³/hr)With the excellent disc technology Y type Screen filter have micron - precise , high efficiency and large volume filteration advantage . The well designed diagonally grooved structured provide. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, fixing and installation rain water harvesting as per architectural dwg. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Earth work in Excavation by mechanical means (Hydraulic excavator) /manual means over areas exceeding 30 cm/90 cm/120 cm in depth, width as well as 60 cm/ 90 cm/ 120cm as/requred on plan, for plinths, sides of foundations, etc. and Re-Filling available excavated earth (excluding rock) in trenches, plinths, sides of foundations, etc., after foundation work in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering. Lead up to 50 m and lift up to 1.5 m (as/Architecture detail drawing).
Reinforced cement concrete work in wall (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, foundation etc. Up to floor five level excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm. nominal size). Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation/ below plinth level in: Cement mortar 1:4 (1 cement : 4 sand) Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level
12 mm cement plaster 1:4 (1 Cement : 4 fine send )
Providing and fixing 1st quality ceramic glazed wall Tile conforming to ISI:15622 (thickness to be specified by the manufacture),1.2 m or 1.5 m from FF/as approved, of approved make in all colours, of any size as approved by Architect/Engineer in case skirting, riser of steps over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 sand) and jointing with grey cement slurry @ 3.3 kg per sqmt, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrifired floor tile/Stone, as/approved, with skirting in different size (thickness to be specified by the manufacture), with water absorption less then 0.08% and conforming to ISI 5622, of approved make in all colours, shades, laid on 20 mm thick as/architect cement mortar 1: 4, jointing with grey cement slurry @ 3.3 kg per sqmt, including grouting the joints white cement and matching pigment etc. Complete size of tile 600X600 mm.
Finishing with deluxe multi surface paint system for interior and exterior using primer as per manufactures specification. Two or more coat applied on wall @ 1:25 ltr/10 sqm over and including one coat of special primer applied @0.75 ltr/10sqmt
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 25 mm 4 core wire
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 20 mm dia conduit pipe
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 50 mm Dia conduit pipe
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 10 mm singel core
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 1 MM copper wire (90 mtr)
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 1.5 mm copper wire (90 mtr)
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 2 mm copper wire (90 mtr)
Electrical workNote: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Architect/Engineer and All wiring laying in the PVC conduit strickle follow IE( Indian Electricity) rules, IS code, follow in all items of project/ work execution. Proper ferrules, lux, thimble , gland termination to be done in all cabling & wiring from both load/source end. Conduit carrying submain will not carry circuit/point wiring. Similarly conduit carrying circuit wiring will not carry submain/point wiring. Conduit carrying point wiring will not carry submain/circuit wiring. All Electrical works (Cabling/wiring/panel etc ) to be carried out as per layout/General Arrangement (GA)Drawing attached only. Providing, fixing, testing and commissioning of POINT WIRING of any length for light point/Wall fan point/Exhaust fan point/ Call bell point/including fan box (if required), 'S' type fan hook etc with 3 X 1.5 Sq.mm(P/N/E) PVC 650V/1100V Grade FR insulated PVC conductor single core multi strended wire in 16 SWG(Medium Gauge) stove enamelled rigid steel conduit 20mm/25mm with conduit accessories like bend, junction box etc in concealed/surface manner as per site requirement with suitable Modular Switches/Sockets with plate and Metal/PVC box,Scaddle, angle bracket (if required), 3 plate ceiling rose/bulb holder etc. The floor/roof/wall junction box should be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM. The above wiring carried out surface or recess in wall/floor/roof should be cutting by cutter/chiesling, replastering, curing, painting with uniform and smooth finish by specilised workman ship and making the surface neat afterwards complete in all respect as per direction of Bank Engg. (EACH Circuit to take NOT MORE than 7-8 points) The conduit/ Flexible conduit/junction box/metal modular box etc must be joined by gland and check nut at both ends. (each circuit to be controlled by one MCB). The colour code of wire are as under: Phase- Red, Neutral- Black, Earth-Green Make of Material for items of BOQ:- (i) Modular Type Switch/socket/step electronic fan regulator, plate, box, TV/telephone, bulb holder/3 pin ceiling rose with all accessories:- Lergand/ Anchor(Roma)/MK/ Crabtree (ii) MS conduit/PVC conduit with all accessories:- BEC/AKG/NIC/Precision (iii) PVC insulated copper wire(FR) 650V/1100 V grade:- Finolex/RR cable/ Havells Supplying, providing CIRCUIT WIRING for Power/UPS with following PVC insulated PVC conductor single core multi strended wire ( HRFR ) in mentioned conduit i/c electrical connections in suitable size PVC modular boxes and it laying, fixing, testing and commissioning in suitable size 20/25 mm dia,16 SWG (Medium Gauge) thickness rigid MS conduit with conduit accessories like bend/junction box/ fan box etcwith cover plate, sheet steel box/ PVC modular box etc on surface/ concealed manner i/c electrical connections and making goods all the damages,replastering, painting, cleaning the site etc complete as required as per site condition. The floor/roof/wall junction box shuold be of MS(heavy duty) box of suitable size and covered with Steel finish Steel cover sheet by screw tight and gasket to avoid water/dust insertion. The length of circuit upto 30 meter length or less as per site condition/requirement. Make of Material (i) MS conduit/PVC conduit with all accessories:- (ii) PVC insulated copper wire(FR) 650V/1100 V grade:- 10 mm copper wire (90 mtr)
MV PANELS & DISTRIBUTION BOARDS Supply, installation, testing and commissioning of M.V. PANELS and switch gears suitable for 415V, 3 phase, 4 wire, 50Hz power distribution system. The panel shall be free standing Wall / floor mounting type 14G/16G sheet steel enclosed, flush front with single aluminium bus bars and separate earth bus to be provided through out the length of the panel. The incoming and out going feeders breakers, changer over switches, fuses indicating lamps shall be accomadated in a modular multi tier arangement. Location- Electrical room all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
CHANGE OVER cum Main PANEL - Manual Location- Electrical room all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, installation, Testing and commissioning of DISTRIBUTION BOARDS and MCB the surface/recess mounting following ways MCB DB's 230/415 Volts with tinned copper busbar, neutral bar, earth bar, din bar detachable gland plate, interconnection and making good all the damages, painting, cleaning the site etc complete as required as per site requirement. All MCCB has braking capacity is 25KA and ALL MCB/ELCB has breaking capacity has 10 KA. Make of Materials Panel- As per IS Standards/CPRI Tested. DBs/MCCB/MCBs- Legrand/Siemens/Hagger/Schneider only ( Note:- Before Placing the Panel order, firstly it Passed by The Bank Authority, otherwise it will not considered) Location-Electrical room all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
All MCB to be "C" & "D" type series and 100Amp Master MCBs (As/requred) MCB Type c - 10 all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
All MCB to be "C" & "D" type series and 100Amp Master MCBs (As/requred) MCB Type D-15 all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
SWITCH BOARD Supply,fixing, testing and commissioning of 1 No 6 AMP MULTI SOCKET BOARD with 1No. 6 A switch ( Modular type ) with cover plate, sheet steel box / PVC modular box etc on surface / concealed manner I/c electrical connections and making good all the damages, painting, cleaning the site etc complete including all accessories as per site requirement and as directed. (Minimum two and Maximum three points are loop with one circuit as mentioned below) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, fixing, testing and commissioning of 1 No 16 A switch & 1 No.six pin 6/16 Amp. Multi Socket ( Modular Type ) with cover plate , sheet steel box etc on surface / concealed manner I/c electrical connections and making good all the damages, painting, cleaning the site etc complete including all accessories as per site requirement and as directed. (Maximum two points are loop with one circuit as mentioned below) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
DESCRIPTION OF LIGHT/ FAN FIXTURE PLUMBING & SANITARY WORK LED LUMINARES:- 6" and 4'' FULL GLOW TYPE/COB, Dura slim/ Slim surface Mount/4 ' tube light 7 watt/ 16 watt/ 18 watt LED light fittings dimension suitable for POP/surface ceiling, complete with its electrionic driver. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Exhaust fan Provding and fixing for, 18"/24" inches exhaust fan all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing ceilling fan all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing wall light 4' Tubelight all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Two side white street light with solar panel and battery with battery and installation all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PLUMBING & SANITARY WORK Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass traded fittings, including fixing the pipe with clamps at 1:00 mm spacing. Testing of the joint complete as per direction of the architect/Engineering charge. 15 mm to 20 mm nominal outer Dia pipes.
Providing and fixing ball valve (Brass) of approved quality, High or Low Pressure, with plastic Floats complete:20 mm nominal bore.
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS Standards and weighing not less than 810 gms.(15 mm nominal bore)
Providing and fixing Extension nipple for water tank pipe, fittings of approved quality and colour 20mm nominal bore, weighing not less than 40 gms.
Providing, placing, and fixing on the terrace at polythylene water storage tank IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(2X1500)
PVC (Poly Vinyl Chloride) pipes (working pressure 4kg/cm) single socketed pipe 100mm /110 mm dia. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PVC single equal T (without door) 100x100x100mm/ 110x110x110mm. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PVC coupler for PVC drainage pipe 100mm/110 mm. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PVC Plain shoe 100mm/110 mm. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing C.P brass Angle value/Stop Cock of approved quality conforming to IS:8931 (15 mm nominal bore short body)
Providing and fixing Uplasticised PVC Connection Pipe with brass unions: 30 cm length 15 mm nominal bore.
PVC Gully or Nahani trap grating 100 mm dia all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing white vitreous china pedestal type W C water closet(European type W.C PAN) with seat and lid, 10 litre level white PVC flushing cistern, including flush pipe, with manually controlled device(handle lever), Jet, conforming to IS ; 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C pan with ISI marked white solid plastic seat and lid.
Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm sand cast iron P or S trap, 10-litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS:7231, with all fitting and fixture complete, including cutting and making good the walls and floors wherever required : Stainless steel AISI- 304(18/8) Orissa pattern W.C pan of size 585x480 mm with flush pipe and integrated type foot rests.
Providing and fixing wash basin /Counter top with 32 mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever/Counter top require. White vitreous china surgeon type wash basin of size 660 x 460 mm with a pair of 15 mm C.P brass pillar taps with elbow including operated levers.
Providing and fixing in position first quality white Urinal (cat. no.URS-WHT13257,UPS-WHT-13253N) as per approval and making all connections of urinal with other accessories such as flush pipe ,outlet, etc. filling including making chases and holes in floors and walls and repairing the same with cement mortar (1:3) plastering etc. to original condition and painting of fittings etc. complete
Providing and fixing mirror of superior glass(of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453 X 357 mm. etc complete.
Providing and fixing PTMT soap dish holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 grams. etc complete
DRINKING WATER Laying fixing and providing drinking water cooler confirming to IS: 1475(Part1):2001 latest Storage capacity- 80 Litres MOC external body-fully SS 304, 0.5 mm thick sheet minimum MOC water tank cover lid and bottom sheet - Al. / G.I. as per OEM and epoxy painted MOC internal Storage tank- SS 304 , 0.5 mm thick sheet Input Voltage 230 Volt , 50 Hz, AC single phase Connecting cable- 3core x1.5 m length confirming to IS: 9968 Power factor : as per OEM design Eco friendly refrigerant (Non CFC) Energy Consumption- as per OEM design Push Type Taps - 2 nos. Type of water purification technology - RO+UV Input power voltage range - 180 - 260 VAC, 1 PH, 50 Hz. Design value of input water TDS to the system - 2000 mg/Ltr maximum Output water quality confirming to standard IS : 10500 ( Latest) Type of mounting - wall mounting Frame - stainless steel ( SS 304) Inlet water - Normal water supply through tap ( borewell water) High pressure pump - Copper wound booster pump as per OEM standard Membrane type - 0.0001 mm RO membrane UV lamp acceptable range - as per OEM design Pre filter- As per OEM design Carbon filter - As per OEM design Warranty - One Year as per OEM standard Capacity of water purifier -50 LPH all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
FABRICATION WORK Providing and fixing structural steel work for tree guards /tree gratings / barbed wire fence using MS pipes, angles, Tees, hollow tubes, square bar,channel, plates, galvanized iron barbed wire with Paint etc.Fabricated to required sizes and shapes and installed in position with necessary hold fast and embedding in position with 1:2:4 cement concrete including all incidental operation like cutting, welding, grinding, bending, drilling, hoisting, scaffolding as required a coat of zinc chromate steel primer and two or more coats of approved make and shade synthetic enamel paint and other operations, all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing Hinges for gate with paint/Primer, all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing Fabrication Circel frame with paint (1M DiaX1.2M) , for Tree Guard / gratings as/required. Location- Ineer tree circal (ring) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing Fabrication for, MS waste material structure/statue/Sculpture/ form/shape etc,with paint as per architecture dwg. Location-Main enrty gate all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing MS Fabrication work with concrete base for, Pergola/Shades etc with paint. GARDEN AREA (8.3mX5.5mX2.4m) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing MS Fabrication work with concrete base for, Pergola/Shades etc with paint. CHILDREN PLAY AREA (19mX3.5mX2.4m) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing MS Fabrication work with concrete base for, Pergola/Shades etc with paint. YOGA GARDEN (20mX10mX2.4m) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing MS Fabrication work with concrete base for, Pergola/Shades etc with paint. PICNIC AREA (20mX10mX2.4m) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing MS Fabrication work with concrete base for, Pergola/Shades etc with paint. TRIANGULAR GREEN AREA (17mX7mX2.4m) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing Fabrication for, MS Yoga Human shape, with 2M hight for Green skipper with paint/primer. Location-Yoga sculpture in yoga garden. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing and fixing aluminium work for Door, Windows, and ventilation partition with extended built-up standard tubular section appropriate Z section and other section of approved make confirming to IS : 733 and IS : 1285, fixing with dash fastener of required and size, including necessary fittings up the gaps at Junction, IE at top, bottom and side with required EPDM rubber/ neoprence gasket, etc. Aluminium section shall be smooth, rest free, straight, and joint mechanically wherever required, including plate angle, aluminium Building for glazing/pencilling CP, brass/stainless steel screw, all complete as per architecture, drawing and the direction of architect/engineer,(Glazing, pencilling, and – fastener to be paid for separately.) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC15), Powder ecated aluminium (minimum thikness of powder coating 50 micron) Providing and fixing 3 mm thick A.C.P (Aluminium composite panel) conforming to ISI : 17682:2021, in Panelling fixed in aluminium door, Window shutters and partition frames with C.P brass/Stainless steel screws etc. Complete as per architectural drawings and direction of architect. Providing and fixing glazing in aluminium door, window, ventilation, shutter, and partition, etc with EPDM rubber/neoprene gasket, etc. Complete as per the architectural drawing and the direction of architect/engineer. "Providing and fixing aluminium, sliding door, bolts, ISI marked anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :" "Providing and fixing aluminium tower bolt, ISI marked, anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :" "Providing and fixing aluminium butt hinges, ISI marked, anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (75x63x4mm)" "Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (125 mm)" "Providing and fixing aluminium Latch, ISI marked, anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (25 mm)" "Providing and fixing aluminium Floor door stopper, ISI marked, anodised (anodic coating not less then grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :"
PRE-CAST CONCRETE BENCH 1500 x 620 x 1000 mm Pre-cast concrete Wilson Stone Turin Quartz Bench, Colour Grey or as/approved (with indigenous games detail). all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
LITTER BINS 600mm x 600mm litter bin to later specification. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
PLAY EQUIPMENT Supply, deliver and install with concrete or required material slide (iron) equipment. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver and install with concrete or required material slide Mary Go Round (4 seater) equipment. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver and install with concrete or required material Slide See Saw equipment. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver and install with concrete or r equired material Spring Rider equipment. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver and install with concrete or required material Slide Play station equipment. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Supply, deliver and install with concrete or required material Slides for lawn mounds. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
OUTDOOR GYM EQUIPMENTS Providing, laying and installing with concrete or required material Parallel bar. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Cycle. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Abs Shaper. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Leg Press. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Chest Press. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Triple Twister. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing Double with concrete or required material Wheel Shoulder. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Horse Rider. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Stand Pull-Up. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing Cross Walker as per architectural dwg. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Push Pull Chair. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Providing, laying and installing with concrete or required material Cross Trainer. all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Laying, fixing and providing Signage board & board, with authority name and logo. Directional signage Informational Signage Safety signage, etc "Interpretive Signage Emergency Exit signage Promotional Signage, etc all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
Laying, fixing and providing with authority name and logo as per dwg and design. (9 inch height) all incidental works complete as per drawings & directions of Architecture/Engineer-in-charge.
AFTER COMPLETION MAINTENANCE FOR 3/6 MONTHS Allow for the complete maintenance and establishment of all planted areas, inclusive of:" "Application of fertilizers, etc. upon instruction, replacement of plants, all according to the specifications and as may be instructed by the Landscape Architect." "Provision of water car for watering of trees, planting and lawn if needed." "The maintenance period will commence upon issue of the Certificate of Practical Completion" Rate to be all inclusive Provision for 3/6 month landscape maintenance on trees and planting
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
ringparkdoc.pdf
Tender Documents • 6.64 MB
BOQ_107738.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid