Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 | |
| 3 | Rejected-Technical 04042156 VALSALAKUMARI N 0404 SUB TREASURY PUNALUR | KOLLAM | KERALA | 689694 | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | KRISHNAKUMAR L1 | NOUSHAD.S L3 | ANIKUTTAN T L2 |
|---|---|---|---|---|---|---|
| 1.00Civil work | ||||||
| 1.00 | 50.10.2
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing
in position and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete | 2,150 | kg | 140 ₹3,00,998.75 Lowest | 155.21 ₹3,33,701.5 | 150 ₹3,22,500 |
| 1.00 | 13.52.1
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied
as per manufacturer's specifications including appropriate priming coat, preparation
of surface, etc. complete.On steel work | 430 | sqm | 205.26 ₹88,261.42 Lowest | 227.56 ₹97,850.8 | 220 ₹94,600 |
| 1.00 | 12.59.1
Providing and fixing false ceiling at all height including providing & fixing of
framework made of special section, power pressed from M.S. sheets and galvanised
with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting
of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm,
at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm
long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of
25x10x0.50mm of required length with nuts & bolts of required size and other end of
angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the
spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of
80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall
be fixed in a direction perpendicular to G.I intermediate channel with connecting clip
made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing
perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm
long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at
450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing
of Calcium Silicate Board to ceiling section and perimeter channels with the help of
day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a
flush finish of tapered and square edges of the board with recommended jointing
compounds, jointing tapes, finishing with jointing compounds in three layers covering
up to 150mm on both sides of joints and two coats of primer suitable for boards, all as
per manufacture's specification and also including the cost of making opening for
light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable
fixed, all complete as per drawings, specification and direction of the Engineer in
charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board
made with Calcareous & Siliceous materials reinforced with cellulose fiber
manufactured through acutoclaving process. | 570 | sqm | 1,377.04 ₹7,84,911.83 Lowest | 1,526.65 ₹8,70,190.5 | 1,476 ₹8,41,320 |
| 1.00 | 50.6.1.3
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 Part I of 1979 for super structure
above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1
cement :6 coarse sand) etc complete | 5 | cum | 6,924.22 ₹34,621.11 Lowest | 7,676.52 ₹38,382.6 | 7,423 ₹37,115 |
| 1.00 | 13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 35 | sqm | 288.66 ₹10,103.03 Lowest | 320.02 ₹11,200.7 | 309 ₹10,815 |
| 1.01 | 13.43.1
Applying one coat of water thinnable cement primer of approved brand and
manufacture on wall surface:Water thinnable cement primer | 35 | sqm | 64.93 ₹2,272.41 Lowest | 71.98 ₹2,519.3 | 70 ₹2,450 |
| 1.01 | 13.83.2
Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile including applying additional coats wherever required to achieve even shade
and colour.Two coats | 140 | sqm | 123.23 ₹17,252.37 Lowest | 136.62 ₹19,126.8 | 132 ₹18,480 |
| 1.01 | OD29033/2024-2025
supplying and fixing plain or multicolor designer polyester woolen carpet using gum
of standard specification, including the cost of carriage and placing at the finished
wall surface as specified as per the direction of engineer in charge | 650 | sqm | 576.22 ₹3,74,546.03 Lowest | 638.83 ₹4,15,239.5 | 618 ₹4,01,700 |
| 2.00Civil work | ||||||
Tender Value
₹21.3 L
EMD Value
₹50,000
Closing Date
15 Jul 2025, 5:00 pmClosed
CHIEF ENGINEER, KSCADC
KSCADC Building, Kamalewsaram , Manacaud P.O. Thiruvananthapuram Pin-695009
Ezhukone Gramapanchayath Annual Plan 2024-25 Ezhukone Panchayath Mahatma Gandhi Auditorium Renovation (Project No.134/2024-25)-Civil and Electrical Work
2025_SCADC_775341_1
ET-34/2025-26
Open Tender
Civil Works - Buildings
Item Rate
90 days
Ezhukone In Kollam -District
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
18 Aug 2025
8 Jul 2025
17 Jul 2025
8 Jul 2025
15 Jul 2025
8 Jul 2025
Amount
Civil work
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.59.1 Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
50.6.1.3 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
OD29033/2024-2025 supplying and fixing plain or multicolor designer polyester woolen carpet using gum of standard specification, including the cost of carriage and placing at the finished wall surface as specified as per the direction of engineer in charge
Civil work
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Sub-Circuit Wiring
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
OD61497/2024-2025 Supply and fixing of connector bar (including connection of wires 4 to 10sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 16mm
OD61498/2024-2025 Supply and fixing of connector bar (including connection of wires 2.5sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 10mm
OD61499/2024-2025 Supply and fixing of connector bar (including connection of wires 1 to 1.5sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 6mm
OD61500/2024-2025 Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 4sqmm wire
OD61501/2024-2025 Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 1.5 to 2.5sqmm wire
OD61529/2024-2025 Supply and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 2x1.00sqmm
Conduits
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD61502/2024-2025 Supply and fixing of Conduit Adaptor Male PVC Lock Nut 20/25mm Hole Dia Seal Connect for Conduit Box that connects the pipes and the electrical boxes. With glue to one end of the conduit, connect the conduit and the adapter and tighten the lock nut to the mounting hole of the bottom box. Made of PVC material, the adapter is waterproof, corrosion resistant, and flame retardant.
90.9.2.1 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.12 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
90.9.2.14 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
90.9.2.2 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
90.9.2.6 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler
90.9.2.8 Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
1.28.2 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Switches and Sockets
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.32 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.10.1.2 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.28.1 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
2.24.3 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD61510/2024-2025 Supply and fixing of Cable Zip Ties, White (100 mm x 2.5 mm,4" inch) Multi- Purpose Self-Locking Nylon Teeth Grip Cable Ties Cord Management Ties, Plastic Ties for cables, industries, Workshop.
OD61512/2024-2025 Supply, installation and commission of TP, 40A, 415V MCB, 'C', curve, 10kA inside DB (Make: Legrand DX3, ABB or any equivalent make approved by KPWD/CPWD/KSADC)
cabling
90.12.6.40 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD61511/2024-2025 Supply and fixing of copper grounding clips (shim) 60 mm long x 12 mm wide x 1 mm thick for single compression glands for 4sqmm to 16sqmm cables.
Grounding
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG)
90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
Fittings
OD61513/2024-2025 Supply, fixing and commissioning of 4", 1X20W LED tube light in plastic frame body with stainless steel clips and stainless screws, as required. (Approved by KSCADC/PWD)
OD61514/2024-2025 Supplying and fixing following SLEEK RD- surface mounted or recessed Round or Square Down light 112545 BGSLO Sleek surface 18/20W cool white LED down light for soft diffused lighting complete light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc as required (Make Philips, Crompton Greeves or equivalent make approved by CPWD/KPWD/KSCADC) testing and commissioning
OD61515/2024-2025 Supply and installation of LED strip light/Flexible Rope Light for Indoor and Outdoor Decorations, Rope Light for False Ceiling, Balcony, Warm/White, Pack of 1 (5M length) (warm/white) with waterproof, made from silicon, good quality adaptor. (Philips or equivalent make approved by CPWD/KPWD/KSCADC)
OD61516/2024-2025 Supply and installation of Hexa style 8W Down lighter (Cool Day Light), Cutout - 4 Inch | Panel Light for False Ceiling (Poly carbonate) (Make: Philips or equivalent make approved by CPWD/KPWD/KSCAD)
OD61517/2024-2025 Supply of Light Duty Exhaust fan in plastic body with self-opening lovers working on 230v single phase A/C - 250mm
90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD61518/2024-2025 Supply and fixing of B22 LED Cool Day White LED Bulb - 9W. (Approved make by CPWD/KPWD/KSCADC)
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD61519/2024-2025 Supply Lamp Shade for angle/pendant type holder. (Approved make by CPWD/KPWD/KSCADC)
OD61520/2024-2025 Supply, installation and commissioning of round/square LED light (3W, 240V, warm light) foot lamp, specially made for staircase lighting on wall surface including necessary connections. (Make must be approved by CPWD/KPWD/KSCADC)
90.4.2 Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1.48 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Networking
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD61522/2024-2025 Supply, crimping, fixing and installation of RJ45 Connector Module Plugs. (Make: D-Link or equivalent make approved by CPWD/KPWD/KSCADC)
OD61523/2024-2025 Supply, Installation and Commissioning of RJ 45 CAT 6 Socket modular type, on existing GI/PVC box with cover and base plate (Make: Elleys, Legrand, Indoasian or any equivalent make approved by KPWD/CPWD/KSCADC)
OD61524/2024-2025 Supply and mounting of Heavy Duty - 2 feet to 3 feet/Foot (24 inch to 36 inch) Adjustable Projector Ceiling and Wall Mount Kit Bracket Stand with Tilt Option (Weight Capacity - 15kgs) (Black - 3 Feet)
OD61525/2024-2025 Supplying and fixing of casing and caping of following size on surface along with accessories. 20mm/25mm (Approved make by CPWD/KPWD/KSCADC)
OD61528/2024-2025 Supply and fixing of 20M 4K Original HDMI Cable, High Speed 18Gbps 4K@60Hz 2160P, Ultra HD,3D,1080p, Ethernet Compatible for TV, Laptop, PC, Monitor & Projector (Black), Gold-plated full metal connector is corrosion-resistant, metal alloy casing with PVC jacket structure prevents signal degradation or attenuation, provide lag-free and uninterrupted viewing experience.1 Year Warranty. (Approved make by CPWD/KPWD/KSCADC)
ANIKUTTAN T (BID ID -2251678)
NOUSHAD.S (BID ID -2251844)
Bidder Name
NOUSHAD.S
ANIKUTTAN T
KRISHNAKUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1267129.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .