Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.9 LAccepted-AOC | ₹16.9 L Quoted ₹17.6 L | 1 | Accepted-AOC Quoted amount being lowest. |
| 2 | 2₹18.0 L+₹44,420 (2.53%)Rejected-Finance | ₹18.0 L+₹44,420 (2.53%) | 2 | Rejected-Finance Quoted amount being not the lowest and reasonable. |
| 3 | 3₹18.6 L+₹1.0 L (5.77%)Rejected-Finance VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | ₹18.6 L+₹1.0 L (5.77%) | 3 | Rejected-Finance Quoted amount being not the lowest and reasonable. |
| 4 | 4₹18.8 L+₹1.2 L (6.78%)Rejected-Finance | ₹18.8 L+₹1.2 L (6.78%) | 4 | Rejected-Finance Quoted amount being not the lowest and reasonable. |
| 5 | 5₹19.0 L+₹1.4 L (8.16%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹19.0 L+₹1.4 L (8.16%) | 5 | Rejected-Finance Quoted amount being not the lowest and reasonable. |
| Sl No | Description | Qty | Unit | M/s Ray construction L5 | upadhyay engineers and consultant L6 | M/S ROHIT CONSTUCTION L3 | M/S ROHIT CONSTUCTION L3 | M/S Akash Enterprises L4 | M/s friend enterprises L2 | M/S Kunwar Construction L1 | M/S SHAMBHU SHARAN SINGH L7 | om suppler L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ reinstallation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back shall be made through proper issue/receipt voucher duly mentioning by MES rep. | 1,715 | Each | 45 ₹77,175 | 42 ₹72,030 Lowest | 50 ₹85,750 | 50 ₹85,750 | 50 ₹85,750 | 50 ₹85,750 | 45 ₹77,175 | 60 ₹1,02,900 | 45 ₹77,175 |
| 2.00 | Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and reassembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as specified and as directed by Engineer-in-charge. | 900 | Each | 160 ₹1,44,000 | 165 ₹1,48,500 | 155 ₹1,39,500 | 155 ₹1,39,500 | 170 ₹1,53,000 | 150 ₹1,35,000 Lowest | 150 ₹1,35,000 Lowest | 185 ₹1,66,500 | 160 ₹1,44,000 |
| 3.00 | Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. | 1,950 | Each | 210 ₹4,09,500 | 220 ₹4,29,000 | 190 ₹3,70,500 Lowest | 190 ₹3,70,500 Lowest | 210 ₹4,09,500 | 195 ₹3,80,250 | 230 ₹4,48,500 | 210 ₹4,09,500 | 210 ₹4,09,500 |
| 4.00 | Supply only Gun Metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. | 20 | Each | 110 ₹2,200 | 110 ₹2,200 | 110 ₹2,200 | 110 ₹2,200 | 120 ₹2,400 | 105 ₹2,100 | 95 ₹1,900 Lowest | 95 ₹1,900 Lowest | 110 ₹2,200 |
| 5.00 | All as per item No 2 here-in-before but for exhaust fans of 450/300/225 sweep and size complete all as specified and as directed. | 35 | Each | 200 ₹7,000 | 205 ₹7,175 | 190 ₹6,650 | 190 ₹6,650 | 210 ₹7,350 | 199 ₹6,965 | 140 ₹4,900 | 125 ₹4,375 Lowest | 200 ₹7,000 |
| 6.00 | M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. | 730 | Each | 680 ₹4,96,400 | 670 ₹4,89,100 | 690 ₹5,03,700 | 690 ₹5,03,700 | 650 ₹4,74,500 | 668 ₹4,87,640 | 570 ₹4,16,100 Lowest | 670 ₹4,89,100 | 680 ₹4,96,400 |
| 7.00 | All as per item No 6 here-in-before but for cutting of existing winding of ceiling fans of 1400 mm sweep complete all as specified and directed. | 20 | Each | 695 ₹13,900 | 700 ₹14,000 | 750 ₹15,000 | 750 ₹15,000 | 670 ₹13,400 | 700 ₹14,000 | 640 ₹12,800 Lowest | 710 ₹14,200 | 695 ₹13,900 |
| 8.00 | M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge. | 15 | Each | 580 ₹8,700 | 600 ₹9,000 | 650 ₹9,750 | 650 ₹9,750 | 590 ₹8,850 | 600 ₹9,000 | 550 ₹8,250 Lowest | 580 ₹8,700 | 580 ₹8,700 |
| 9.00 | All as per item No 8 here-in-before but for cutting of existing winding of exhaust fans of 300/250 mm sweep complete all as specified and directed. | 15 | Each | 540 ₹8,100 | 550 ₹8,250 | 550 ₹8,250 | 550 ₹8,250 | 550 ₹8,250 | 550 ₹8,250 | 490 ₹7,350 Lowest | 560 ₹8,400 | 540 ₹8,100 |
| 10.00 | Supply & fix in repair 2.5 mfd capacitor suitable for ceiling fans of 1200/1400 mm sweep of approved make complete all as specified and as directed. | 1,680 | Each | 90 ₹1,51,200 | 86 ₹1,44,480 | 88 ₹1,47,840 | 88 ₹1,47,840 | 80 ₹1,34,400 | 78 ₹1,31,040 Lowest | 105 ₹1,76,400 | 90 ₹1,51,200 | 90 ₹1,51,200 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
11 Jul 2026, 6:00 pmClosed
GE RAMGARH CANTT
RAMGARH CANTT
REPAIRS MAINTENANCE OF CEILING FAN EXHAUST FAN, WALL MOUNTED FAN, AIR CIRCULATOR AND DESERT COOLER AT RAMGARH CANTT
2026_MES_773760_1
8300/3424/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAMGARH CANTT
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE RAMGARH CANTT
₹36,000
Yes
19 Sept 2026
20 Jun 2026
18 Jul 2026
20 Jun 2026
11 Jul 2026
4 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ reinstallation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back shall be made through proper issue/receipt voucher duly mentioning by MES rep. | - | Each | 100 | - |
| 2 | Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and reassembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as specified and as directed by Engineer-in-charge. | 900 | Each | 100 | ₹90,000 |
| 3 | Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. | - | Each | 10 | - |
| 4 | Supply only Gun Metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. | 20 | Each | 10 | ₹200 |
| 5 | All as per item No 2 here-in-before but for exhaust fans of 450/300/225 sweep and size complete all as specified and as directed. | 35 | Each | 10 | ₹350 |
| 6 | M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. | 730 | Each | 10 | ₹7,300 |
| 7 | All as per item No 6 here-in-before but for cutting of existing winding of ceiling fans of 1400 mm sweep complete all as specified and directed. | 20 | Each | 10 | ₹200 |
| 8 | M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge. | 15 | Each | 10 | ₹150 |
| 9 | All as per item No 8 here-in-before but for cutting of existing winding of exhaust fans of 300/250 mm sweep complete all as specified and directed. | 15 | Each | 10 | ₹150 |
| 10 | Supply & fix in repair 2.5 mfd capacitor suitable for ceiling fans of 1200/1400 mm sweep of approved make complete all as specified and as directed. | - | Each | 10 | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
TENDER3424.pdf
Tender Documents • 1.98 MB
BOQ_866395.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .