180 days
Nahan
Please refer Tender documents.
12 documents required · 12 mandatory
₹800
Executive Engineer Jal Shakti Division Nahan
₹92,500
Yes
9 Oct 2020
6 Mar 2020
21 Mar 2020
6 Mar 2020
21 Mar 2020
6 Mar 2020
Amount
Rising main
Excavation in drains and channels etc.in earth work for pipes up to all depths in all classification of earthwork such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chiseling soft / hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming & dressing of sides, leveling of beds to correct grade including shoring/struting, planking, timbering & dewatering wherever required stacking the useable/unuseable material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated soil/unuseable material as directed with in all leads & lifts including restoration of un-metalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with-in all leads & lifts as per directions of the Engineer Incharge.
Providing,Laying, jointing, testing & commissioning at site in trenches bevelled ended MSERW pipes of Grade "A" or "L-210" confirming to code IS/ISO -3183-2007 having wall thickness and per Rmt weight as mentioned below and capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with upto date ammendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site , tail pieces, tees,bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes whereever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have's zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with IS/ISO 3183-2007, grade "A"or "L-210" .The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work shall be measured & paid for separately).
Sr.No. R.Ds Nominal Dia Thickness Length (in Mtrs) Pipe Specification
From To
Johron
0 - 100 5 mm 4.80 100 mtrs Grade-A or L 210
Moginand
0 - 1920 80 mm 4.80 1920 mtrs Grade-A or L 210
Laying, , jointing , testing & commissioning at site in trenches following plain ended GMS pipes of various diameters as under confirming to BIS 1239-(Part-1)-1990 or latest with up to date ammendments, capable of withstanding required test pressure as prescribed in BIS code, in randum lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt weld, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends manufactured from parent pipes etc. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts as directed by Engineer-Incharge (Earth work shall be measured & paid for seperately).
Sr.No. R.Ds Nominal Dia Length (in Mtrs) Pipe Specification
From To
Johron
100 - 200 125 mm 100 meters GMS(M)
Bankabara
0 - 1920 100 mm 1920 meters GMS(H)
1920 - 6980 100 mm 5060 meters GMS(M)
Moginand
1920 - 3840 80 mm 1920 meters GMS(H)
3840 - 6840 80 mm 3000 meters GMS(M)
Providing, welding and fixing M.S. plate flanges of various dia. (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to MSERW/GI pipes after every 90 metres or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect i/c all leads, lifts and carriage of material at site and as directed by the Engineer Incharge.
Sr.No. R.Ds Nominal Dia length (in Mtrs) Flange Table
From To
Johron
0 - 200 125 mm 200 mtrs FT-17
Bankabara
0 - 3840 100 mm 3840 mtrs FT-17
3840 - 6980 100 mm 3140 mtrs FT-5
Moginand
0 - 480 80 mm 480 mtrs FT-28
480 - 4320 80 mm 3840 mtrs FT-17
4320- 6840 80 mm 2520 mtrs FT-5
Pumping machinery (Johron)
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington / Sabar/ Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No.5A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- Head:- 206.14 Mtrs, Capacity(LPS):- 11.70 LPS, Dia of Column Pipe:- 125mm, Dia of Rmain:- 125mm, 2x60HP= 120HP, Note:-Tenders to be called for per set not for per HP rate
Supply &fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 5(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-300.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
Pumping machinery.(Moginand)
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington / Sabar/ Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No. 9 A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- Head:- 215.16 Mtrs, Capacity (LPS):- 4.75 LPS, Dia of R/main:- 80mm, Length og R/main:- 6840 mtrs, 2x25HP=50HP, Note:-Tenders to be called for per set not for per HP rate
Supply &fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 9(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-300.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 9(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-300.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
Pumping machinery.(BANKABARA)
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington / Sabar/ Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No.13 A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- Head:- 197.50 mtrs, Cpacity(LPS):- 6.94 LPS, Dia of R/main:- 100mm, Length of R/main:- 6980 mtrs, 2x40HP = 80 HP, Note:-Tenders to be called for per set not for per HP rate
Supply &fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.13(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-300.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 13(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-300.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
Errection of all equipments of all the parts (Johron,Bankabara and Moginand) including cost of column pipes for submersible pump ( as per site requirement ) in sump well , tapers ,bends, tees etc and any other fittings required as per site conditions and as per direction of the Engineer Incharge.
Providing and fixing of fully automatic Star-Delta starter IP 54 panel fabricated with powder coated 1.6mm MS Sheet and MS angle base frame suitable for floor mounting complete in all respects with all leads and lifts as per direction of Engineer-in-Charge including testing, commissioning with following features:-
Suitable 3 Nos. fully automatic Star Delta starters (25,40 and 60 HP ) to be installed in single panel enclosure.
All switchgear items make should be Schneider/ABB/ L&T/MEI/GEC/ or equivalent.
MCCB of suitable capacity of Schneider/ABB/ L&T/MEI/GEC/Standard make on in-coming feeder for motors /pump for isolation/ protection offered by the tenderer conforming to BIS IS 2516-1-1: 1985 latest with up-to date amendments.
Internal power /control wiring XLPE Insulated, PVC tape/Extruded Inner sheathed for Multicore Cables, Un-armoured, PVC Type ST2 sheathed, 650/1100V grade as per IS 7098 (Part 1) 1988 .
Suitable size mains incoming MCCB 3 Pole (50kA) with neutral bus-bar link, Common for both star-delta starter and subsequent separate suitable size mains incoming MCCB 3 Pole (50kA) for each star-delta starter.
Protections to be incorporated: Single Phasing, Over/under voltage, Over Current, Dry Run.
Common 3 Phase VAF meter digital with separate digital run hour meter for each starter.
RYB phase LED lamp indications, RUN, TRIP, OFF indications for each starter.
Start, Stop, Reset Push Buttons for each starter.
Adequate size fan for forced cooling with on/off switch, replaceable filter arrangement at panel front door.
Inbuit GSM mobile based remote pump auto operation control cum protection device with Remote start / stop operation of pump with call /SMS. Pump start / stop feedback through call /SMS with reason of stop / trip. Pump start / stop feedback for unauthorized local start / stop through starter. Auto / Manual mode for auto pump start post grid supply resumption. Remotely settable timer for scheduling pump start / stop on Hourly / daily / Weekly / Monthly basis. Remotely settable timer for scheduling pump starter / stop for fixed hours in a day. Inbuilt GPS tracker for prevention of loss / theft. Controlled operation access through authenticated minimum 10 mobile numbers only which can be added for removed by main us remotely. Device should also provide Protection against over load, / under voltage. Dry run, phase reversal, Single phasing. With user configurable remotely settable voltage and current limits for these protections
shiv iron general engineers
The Nandini Enterprises and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .