COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO. CWE /HILLS /RKT/80 OF 2021-2022 SPL REPAIR TO BLDG NO. P-53 (04 QTRS) S AND T MES COLONY AT RANIKHET UNDER GE RANIKHET
2022_MES_513398_1
CA NO. CWE /HILLS /RKT/80 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
ran
class E
9 documents required · 9 mandatory
₹500
GE RANIKHET
₹33,400
Yes
27 May 2022
12 Mar 2022
25 Apr 2022
12 Mar 2022
23 Apr 2022
11 Apr 2022
13 Mar 2022 - 27 Mar 2022
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed.
M & L for 10 mm thick backing coat or bedding in CM 1:4 to receive wall finishes complete all as specified and directed.
M & L for Non skid ceramic coloured/printed tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L for Non skid ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
All as per item No. 06 but for dado/skirting complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 for backing of dado/skirting complete all as specified and directed.
M & L for glazed ceramic coloured tiles 300mm x 450mm x 7mm thick as on vertical surface of wall and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L Black Granite (of any type) tiles 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishig types in cooking platforms and like complete all as specified and directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate) for Chajjas complete all as specified and directed.
M & L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate) for Columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed.
M&L for formwork to rough finished surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster from brick work or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. And removing rubbish to a distance not exc 250 meter complete all as specified and directed.
M&L for rendering 15 mm thick faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement includig mixing of water proofing compound of approved make complete all as specified and directed. ( Note:- water proofing compound will be measured and paid seperately).
M & L for rendering 15mm thick in cement mortar 1:6, surface finished even & smooth with a dubbing out average 10mm thick on irregular face of walls, complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished smooth and even in ceiling without using extra cement complete all as specified and directed..
Supply only Integral water proofing compound complete all as specified and directed.
M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surface preparatory to distempering) complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M/L for complete removal of existing treatment for preparing old painted surfaces and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, pillars etc complete all as specified and directed.
M&L for precast type PCC 1:3:6 cement concrete hollow block masonry exc. 10 cm in width and setting in 1:4 cement mortar complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Taking down chowkhat or frame area n. exc 1.50 Sqm each with shutter (without taking off shutters from the frames) and removing from site complete all as specified and directed.
Taking down chowkhat or frame area exc 1.50 Sqm but not exc 4.00 Sqm each with shutter (without taking off shutters from the frames) and removing from site complete all as specified and directed.
Taking down shutters ( per leaf ) of any description exceeding 1.00 sqm each but not exceeding 2 Sqm each complete all as specified and directed.
S&F Plain, solid, straight 2nd class hardwood chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
S&F factory made shutters 2nd class HW rail and style 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treat complete all as specified and directed.
S&F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., rs, edges of framing plain, chamfered complete all as specified and directed.
M&L for PCC 1:3:6 Type C1 (using 20mm graded coarse aggregate) as in hold fasts in masonry walls etc complete all as specified and directed.
S&F flat iron as in clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and directed.
S & F 100 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S & F 200 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 75mm complete all as specified and directed.
S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 100mm complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for newly painting to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
S & F in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples complete all as specified and directed..
S & F in repairs Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples complete all as specified and directed..
S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces complete all as specified and directed..
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 190-0 or Fe-165 complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F GI water tubing of 15mm dia , medium grade conforming to IS-1239 (Part -1) including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls, ceilings, & laid on floors complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, fency type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed..
S&F in repairs, 550x400mm vitreous China, wash hand basin , flat back with pedestal excluding trap and waste chain and plug and porcelain stopper including sutaible size brackets waste pipe and waste coupling complete all as specified and directed.
Taking down and refixing 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
Taking down & refixing 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and directed.
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests with 'P; or 'S' trap, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. in reapairs including Provn of lime concrete bedding and making good to floor complete all as specified and directed.
S&F in repair Traps 100 mm P or S with long arm complete all as specified and directed.
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and directed.
M & L for 32mm bore high density polyethylene pipes (HDPE) complete all as specified and directed.
M&L for 75mm dia PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR), waste & vent pipe single socketed in any length with rubber ring joints & fixed to wall or in floor complete all as specified and directed.
S & F 100mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs Chromium plated shower rose 125 mm swivel type complete all as specified and directed.
S & F 20mm dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified and directed.
S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends complete all as specified and directed.
M&L for cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
S&F ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Water tanks, open or closed, hoisted and fixed in position exc 250 and n. exc 500 ltrs complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw complete all as specified and directed.
S&F Pre painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw complete all as specified and directed.
M & L for anodised aluminium snap grid size of grid 605x605mm frame work for false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Fixing only for anodised aluminium snap grid size of grid 605x605mm frame work for false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed(old material should be used).
M & L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
M & L for in repair except material for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
S&F in repair gun metal, globe or gate valves, with iron wheel head, screwed both ends bore dia of pipe 40mm for iron pipe and fixed for complete all as specified and directed.
M&L for sunken floor treatment as described as under (i) to (v) :- (i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (ii) M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using bk aggregate over the treated surface. (iii) M&L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time. (iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of OMIPLAS EP-101 epoxy compound shall be applied. (v) Spouts of 25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed. (vi) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified and directed.The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated complete all as specified and directed.
Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) of minimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer on 15mm thick plastered sufaces layer in CM 1:4 with water proofing compound (WPC) @3% by weight on concrete surface roof / parapet, over lap of minimum 75 mm on longitudinal direction and 100 mm on the transverse direction by thermo-fused torch flame application method and top surfaces to be treated with non reflective bituminous aluminium paint @0.15 Kg/Sqm all as per manufacturers instructions as complete all as specified and directed .
Surface Excavation in hard/dense soil n,exc 30cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L 75 mm thick cement concrete 1:4:8 type D-2 finished fair and even as in sub base complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in CM 1:6 to receive floor finishes complete all as specified and directed.
M&L for chequered cement concrete tiles of size 200x200x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing Excavated soil exceeding 250 M but not exceeding 500M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed.
S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed. One light/one fan/one bell point controlled by one, one way switch.
All as per item No. 102 but for one light point controlled by two Nos of two way switch complete all as specified and directed..
All as per item No. 102 but for one socket outlet 5 pin 5 Amp controlled by one, one way switch on same board complete all as specified and directed..
All as per item No. 102 but for one socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board complete all as specified and directed..
All as per item No.102 hereinbefore but wiring with using cable 2.50 sqmm size copper wire (FRLS) and earth wire of PVC insulated (Green colour) 1.50 Sqmm size copper wire for one 6 pin socket outlet, 16 Amperes on independent board complete all as specified and directed.
S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
S&F switch piano flush type single pole, Two way 6 Amp complete all as specified and directed.
S&F socket out let multi 5 pin, 5 Amps, flush type complete all as specified and directed.
S&F switch piano flush type single pole, one way 15 Amp complete all as specified and directed.
S&F socket out let 2 in1, 3 pin, 5 and 15 Amp, flush type complete all as specified and directed.
S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed.
S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
S & F MCB single pole, 240 volts, 5 to 32 Amp, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Taking down unservicable MCB and S&F MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps complete all as specified and directed..
Taking down unservicable MCB and S&F MCB DP , 240 volts,AC C curve, 10 KA 40 Amps complete all as specified and directed..
Taking down unserviceable MCB and S & F MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps complete all as specified and directed..
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed .
Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed .
Taking down unserviceable main switches MCB DB & S&F sheet metal enclusure for DBs(double door type) Triple pole and neutral 4way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed .
Taking out old U/S Sub main wiring for replacement including S&F sub main wiring with two single core FRLS PVC insulated and sheathed 1100 Volts grade, 6 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 4.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length).
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
S & F call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed.
S&F bell push piano flush type single pole, one way 5 Amp complete all as specified and directed.
S& F LED Bulb of 9 watt complete all as specified and directed.
Supply, laying, jointing and commissioning LT XLPE 1100 volts 16 sqmm 4 core grade heavy duty under ground cable PVC insulated, strandred aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes, in duct on pole and roads etc. complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr and deposited where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and directed.
M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches complete all as specified and directed.
M&L for brick protection covers laid over cables of sub class B bricks old size (230X115X75)mm complete all as specified and directed.
M&L for GI pipe 40mm bore light grade with all fittings as in protection pipe for cable complete all as specified and directed.
M/s RK JOSHI&SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .