Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.7 LAccepted-Finance 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI CHENNAI TAMIL NADU 600029 | 600029 | ₹25.7 L | 1 | Accepted-Finance Lower Bid |
| 2 | 2₹28.0 LRejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹28.0 L | 2 | Rejected-Finance Higher Bid |
| 3 | 3₹33.7 LRejected-Finance | ₹33.7 L | 3 | Rejected-Finance Higher Bid |
| 4 | 4₹44.2 LRejected-Finance B 71 ASHISH ROW HOUSE 395009 RANDER SURAT GUJARAT 395009 UDYAM GJ 22 0018204 24AEKPG4203R1ZD R S MSME STATUS AS NOT VERIFIED | SURAT | GUJARAT | 395009 | ₹44.2 L | 4 | Rejected-Finance Higher Bid |
| Sl No | Description | Qty | Unit | SURAJ SALES CORPORATION L4 | TOOT MNE TECH Private Limited L1 | VK BUILDING SERVICES PVT. LTD. L2 | BLUE STAR LTD L3 |
|---|---|---|---|---|---|---|---|
| 1.00PART A : Comprehensive Annual Maintenance of HVAC Equipment consisting of below mentioned equipment. | |||||||
| 1.01Cooling Towers : Comprehensive Annual Maintenance of 04 No's Cooling Towers including VFD logic controller, Communication card (BACnet protocol) to transfer the entire data available on VFD to the CPM and third party BMS System. VFD for Cooling Tower fan. Repair/ Replacement of all Cooling tower parts viz. Fills,Drift Eliminator, Louvers, Fan Mesh,Motor and winding ,Fan Gaurd , Belts , Belt Shafts, All Bearings,Pulley,Keys, FRP Louvers, Bed ,GRP Sump, Fibre Reinforced Plastic ( FRP) Body Float Valve, Nozzles,HD Pipes and other complete accessories as described in the technicals pecifications. Make : ADVANCE 2020, MODEL NO: A91,CAPACITY - 310 TR ,MOTOR HP/PH/KW: 20(HP),3PH,15(KW),MOTOR RPM: 1400RPM | |||||||
| 1.02 | CMC Charges for First Year | 1 | Lot | 4,81,971 ₹4.8 L | 4,38,960 ₹4.4 L | 4,34,000 ₹4.3 L | 2,48,000 ₹2.5 L |
| 2.00 | Water Treatment : Water treatment for Cooling tower and Chilled water whic includes Maintaining of water parameters of Cooling Tower water and Chilled Water as per OEM standards (Attached in enclosure) by using Chemicals for preventing problems like Corrosion, Scale Deposition,Bio-Dispersant,Oxidizing Biocide,Green Biocide and Microbial growth in cooling tower water and chilled water system. Scope includes yearly supply of appropriate chemicals and water Testing kits for monitioring of water parameters as recommended by Chiller and Cooling Tower OEM.Vendor has to undertake quarterly test report from third party Labrotary for authentic testing of Chilled water and cooling tower water and also has to supply portable testing kits for daily monitoring of Water parameters..
Note : Adding of chemical and daily testing of water parameters will be undetaken by HBCH&RC,Visakhapatanam.
Chilled Water Parameters to be maintained as per OEM:- Ph Value- 7.5 to 8.5 , Total Hardness ( Caco3) - Max 80 PPM, Total Alkanity (Caco3) - Less than 100 PPM, Chloride Ion - Less than 50 PPM,
Total Ion (Fe) - Less than 0.3 PPM, Silica (Sio2) - Less than 30, Ammonium Ion - Less than 0.2 PPM, TDS - Max 1200
Cooling Tower Water Parameters to be maintained as per OEM:- Ph Value- 7.5 to 8.5 , Total Hardness ( Caco3) - Less than 200 PPM, Total Alkanity (Caco3) - Less than 100 PPM, Chloride Ion - Less than 200 PPM,
Total Ion (Fe) - Less than 1.0 PPM, Silica (Sio2) - Less than 50, Ammonium Ion - Less than 1.0 PPM, TDS - Max 1500
Municipal Water Parameters :- Ph Value- 8.0 , Total Hardness ( Caco3) - 80 PPM, M Alkanity - 80 PPM, Chloride Ion - 30 PPM, P. Alkalinity - 30 PPM, Calcium Hardness - 40 PPM, TDS - 200
Note:- 1. Contractor/Vendor should test the water and prepare chemical treatment to match the water parameters of Chiller and Cooling Tower as mentioned above.
2. The contractor/Vendor should provide Chemicals and Test Kits which will be added by HBCH&RC, Visakhapatnam. | - | - | - | - | - | - |
| 2.01 | CMC Charges for First Year | 1 | Lot | 4,81,971 ₹4.8 L | 2,95,000 ₹3.0 L | 4,50,000 ₹4.5 L | 5,30,000 ₹5.3 L |
| 3.00CAMC of Floor Mounted AHU's: Comprehensive Maintenance of below mentioned AHU's Consisting of 45±5mm thick panel with PUF insulation, filter sections, 6 (or) 8 row deep water coil of copper tube & aluminium fins, copper header, Strip Heaters with Thyristor controller (wherever specified), backward curved centrifugal plug fan, Fire ratardant canvass connections, internal power and control wiring. Fan motor rating of 415±10% volts, 50 cycles, 3 phase AC supply & high efficiency (EFF-1) and suitable for VFD operation.Supply Air Stream & Return Air Stream consists of Filter sections Pre filters (Class: EU-4,Efficiency: 90% down to 10u), Bag Filters (Class: EU-7,Efficiency: 90% down to 3u), Enthalpy recovery wheel ( HRW ) for fresh air section & accessories, HRW Motor ( wherever applicable) ,Drain pan replacement, Discharge Plenum section,Fan section with blower and direct driven motor,Motor winding ,Motor and Blower Bearings , Fans, Pulleys , Shaft Keys,Motor and Blower Shaft ,Coupling parts,AHU Door knobs,Handles & Hinges, Vibration Mounts/ Springs, Limit switches, Blower chamber lights replacement, Canvass cloth, HRW Motor Belts,Temperature Controller with Panel for BMS Compatibility.AHU Coil cleaning including provision of chemicals for cleaning ( Every Half yearly) , AHU Heaters,Heater Thermostat/Temperature Controller and Sensor ,Chilled water Actuator and Temperature Controller with Sensors,Repair/Replacement of Cooling Coil, Motor And Blower Alignment,Blowers, Make : System Air, Flakt Woods Note 1 : Cleaning/Replacing of Filters and cleaning of AHU's both from inside & outside will be undetaken by HBCH&RC,Visakhapatnam Only. Note 2 : Vendor has to supply all the type of filters installed in AHU which will be replaced by HBCH&RC(V). Note 3 : The Vendor has to undertake the maintenance of AHU's as per the Maintenance format mentioned in Tender Document Page No.141 to 147. | |||||||
| 3.01 | CMC Charges for First Year | 1 | Lot | 3,81,971 ₹3.8 L | 3,25,680 ₹3.3 L | 2,27,500 ₹2.3 L | 5,09,860 ₹5.1 L |
| 3.02Hospital Block AHU's ( 23 No's )of below mentioned capacities:- | |||||||
| 3.03AHU ID: HOS-GF-AHU-01 QTY: 01no's AHU Make: SYSTEM AIR,MODEL NO: AHUM-GN-S1612-1978/01, Capacity: 21TR, 11650CFM,1980CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP/10.4A, MOTOR BRG NO: 6208 2Z/6208 2Z, | |||||||
| 3.04AHU ID: HOS-GF-AHU-02 QTY: 01no's AHU Make: SYSTEM AIR, MODEL NO: AHUM-GN-S1612-1978/02, Capacity: 18TR, 10000CFM,17000CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5056-D28, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 3.7KW/5.0HP, MOTOR BRG NO: 6206 2Z/6205 2Z, | |||||||
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
20 Dec 2025, 5:30 pmClosed
Director, HBCHRCV
Homi Bhabha Cancer Hospital Research Center Visakhapatnam, Andhra Pradesh, 530053
Comprehensive Annual Maintenance Contract for Low side HVAC equipment including One Time repair and Supply of spares for HVAC and its associated Electrical Panels at Homi Bhabha Cancer Hospital Research Center Visakhapatnam, Andhra Pradesh, 530053
2025_TMC_888669_1
HBCHRC/Mech/2025-26/NIT/06 dated 04/12/2025
Open Tender
Machineries/ Mechanical Engg Items
365 days
Homi Bhabha Cancer Hospital Research Center Visakh
as per NIT
2 documents required · 2 mandatory
₹0
₹57,600
Homi Bhabha Cancer Hospital Research Center Visakh
28 Jan 2026
6 Dec 2025
27 Dec 2025
6 Dec 2025
20 Dec 2025
6 Dec 2025
6 Dec 2025 - 15 Dec 2025
10 Dec 2025
PART A : Comprehensive Annual Maintenance of HVAC Equipment consisting of below mentioned equipment.
CMC Charges for First Year
CMC Charges for First Year
CMC Charges for First Year
Hospital Block AHU's ( 23 No's )of below mentioned capacities:-
AHU ID: HOS-GF-AHU-01 QTY: 01no's AHU Make: SYSTEM AIR,MODEL NO: AHUM-GN-S1612-1978/01, Capacity: 21TR, 11650CFM,1980CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP/10.4A, MOTOR BRG NO: 6208 2Z/6208 2Z,
AHU ID: HOS-GF-AHU-02 QTY: 01no's AHU Make: SYSTEM AIR, MODEL NO: AHUM-GN-S1612-1978/02, Capacity: 18TR, 10000CFM,17000CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5056-D28, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 3.7KW/5.0HP, MOTOR BRG NO: 6206 2Z/6205 2Z,
AHU ID: HOS-GF-AHU-03 & 04 QTY: 02no's AHU Make: SYSTEM AIR, MODEL NO: AHUM-GN-S1612-1978/03 & 03A, Capacity: 16TR, 8600CFM,14620CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD 28 F SECTOR 31 SAIT- KASNA, AHU BLOWER MODEL: RLM/RLC;E6-3540-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP/10.4A, MOTOR BRG NO: 6208 2Z/6208 2Z,
AHU ID: HOS-1F-AHU-03 QTY: 01no's AHU Make: SYSTEM AIR,MODEL NO: AHUM-GN-S1612-1978/04, Capacity: 28TR,15750 CFM,26775 CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD 28 F SECTOR 31 SAIT- KASNA, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP, MOTOR BRG NO: 6208 2Z/6208 2Z, AHU COIL MAKE: SYSTEM AIR, AHU COIL R.D & CFM: 6 & 15750, VCD Model : WDD, VCD Size: 1900x515mm,
AHU ID: HOS-1F-AHU-04 QTY: 01no's AHU Make: SYSTEM AIR, MODEL NO: AHUM-GN-S1612-1978/05, Capacity: 30TR, 16800 CFM,28560 CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD 28 F SECTOR 31 SAIT- KASNA, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP, MOTOR BRG NO: 6208 2Z/6208 2Z, AHU COIL MAKE: SYSTEM AIR, AHU COIL R.D & CFM: 6 & 16800,VCD Model : WDD, VCD Size: 2000x515mm
AHU ID: HOS-2F-AHU-01 QTY: 01no's AHU Make: SYSTEM AIR,MODEL NO: AHUM-GN-S1612-1978/06, Capacity: 14TR, 8000CFM,13600CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-4550-D28, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 2.2KW/3.0HP, MOTOR BRG NO: 6206 2Z-C3/6206 2Z-C3, AHU COIL MAKE: SYSTEM AIR, AHU COIL R.D & CFM: 6 & 8000,VCD Model : WDD, VCD Size: 1200 x 415mm
AHU ID: HOS-2F-AHU-02 & 03 QTY: 02no's AHU Make: SYSTEM AIR, MODEL NO: AHUM-GN-S1612-1978/09&10A, Capacity: 24TR, 13300CFM,22610CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP, MOTOR BRG NO: 6208 2Z/6208 2Z-C3, AHU COIL MAKE: SYSTEM AIR, AHU COIL R.D & CFM: 6 & 13300,VCD Model : WDD, VCD Size: 1600 x 515mm
AHU ID: HOS-2F-AHU-04 & 05 QTY: 02no's AHU Make: SYSTEM AIR,MODEL NO: AHUM-GN-S1612-1978/07&08, Capacity: 12TR, 7000CFM,11900CMH, AHU STATIC PRESSURE: 70mm of WC, AHU BLOWER MAKE: NICOTRA INDIA PVT LTD, AHU BLOWER MODEL: RLM/RLC;E6-5663-D38, BLOWER QTY: 02 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 02 No's, MOTOR KW/HP: 5.5KW/7.5HP, MOTOR BRG NO: 6208 2Z/6208 2Z-C3, AHU COIL MAKE: SYSTEM AIR, AHU COIL R.D & CFM: 6 & 7000,VCD Model : WDD, VCD Size: 850 x 515mm
AHU ID: HOS-1F-AHU-01 QTY: 01no AHU Make: Flakt woods group, MODEL NO: FGTU-120, Capacity:30 TR, Dehumidified Air: 12000 CFM, FA:1200 CFM, RA: 10800CFM, AHU STATIC PRESSURE: 65mm of WC,AHU BLOWER MAKE: Nicotra-Gebhordt, Fan RPM/Hz : 1402/48, BLOWER QTY: 01 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 01 No's, MOTOR KW/HP/AMP: 7.5KW/10HP, MOTOR BRG NO: 6208 2Z/6208 C3,
AHU ID: HOS-1F-AHU-02 QTY: 01no AHU Make: Flakt woods group, MODEL NO: FGTU-110, Capacity: 26 TR, Dehumidified Air: 10400 CFM, FA:1040 CFM, RA: 9360CFM, AHU STATIC PRESSURE: 65mm of WC,AHU BLOWER MAKE: Nicotra-Gebhordt, Fan RPM/Hz : 1293/44, BLOWER QTY: 01 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 01 No's, MOTOR KW/HP/AMP: 7.5KW/10HP, MOTOR BRG NO: 6208 2Z/6208 C3,
AHU ID: HOS-TF-AHU-10 QTY: 01no AHU Make: Flakt woods group, MODEL NO: FGTU-150, Capacity: 36 TR, Dehumidified Air: 14400 CFM, FA:1440 CFM, RA: 12960CFM, AHU STATIC PRESSURE: 65mm of WC,AHU BLOWER MAKE: Nicotra-Gebhordt, Fan RPM/Hz : 1579/53, BLOWER QTY: 01 No's MOTOR MAKE: BHARAT BIJLEE, 3PH IND.MOTOR, MOTOR QTY: 01 No's, MOTOR KW/HP/AMP: 11KW/15HP, MOTOR BRG NO: 6208 2Z/6208 C3,
CMC Charges for First Year
CMC Charges for First Year
CMC Charges for First Year
CMC Charges for First Year
CMC Charges for First Year
CMC Charges for First Year
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
FORMSATOH.xls
Additional Documents • 0.07 MB
FormOfAgreement.pdf
Additional Documents • 0.49 MB
MaintenanceFormat.pdf
Additional Documents • 0.70 MB
LetterOfTransmittal.pdf
Additional Documents • 0.63 MB
PreferredMakes.pdf
Additional Documents • 0.65 MB
ScopeOfWork.pdf
Tender Documents • 0.62 MB
TenderDoc.pdf
Tender Documents • 2.89 MB
BOQ_934051.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid