Loading…
Loading…
Tender Value
₹14.7 L
EMD Value
₹36,684
Closing Date
7 Jul 2026, 11:00 pm
Similar tender results from the same govt authority in the past 3 years.
Karnataka Power Corporation Limited
a)Removal of cables from the existing junction boxes,further identification of cables as per the drawing and putting tags.b)Dismantling of existing defective junction boxes from its location and installation of new junction boxes,entry of cables with cable glands and further termination of cables in new junction boxes with proper ferruling.c)Finally loop checking of the cables from newly installed junction boxes to PLC control cabinets and further checking the operation of field instruments from remote operation through PLC/SCADA system under the supervision of I&C engineer. Shifting of newly supplied junction boxes along with accessories to KPCL stores/site location will be under the scope of bidder/agency itself.Shifting/Handing over of released junction boxes to KPCL storeswill be under the scope of bidder/agency itself.The required consumables/T&P required for the work shall be arranged by the bidder/agency only.
308805
KPCL/2026-27/PS/WORK_INDENT4267
Open
Power stations
KPCL Executive Engineer IOLA2 Office RTPS Raichur
8 documents required · 6 mandatory · 2 optional
Department Registration Details
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing work
List of works for which tenders already submitted
Banker Details
A)The intending bidder should have the experience in supply and installation of instrumentation/electrical junction boxes, cable glands, cable lugs and terminal blocks and shall have carried out cable laying works in any thermal power station of capacity not less than 210MW OR in any process industries. As a proof of this relevant documents shall be uploaded in bid documents. B)The intending bidder should have satisfactorily completed (as a prime contractor) atleast one such work of value not less than Rs. 8.7 Lakhs in the preceding five financial years (2021-22, 2022-23, 2024-25, and 2025-26) in any thermal power station of capacity not less than 210MW OR in any process industries. As a proof of this bidder should upload a single work order and its corresponding work done certificate issued by the competent authority not below the rank of Chief Engineer in case of KPCL works and not below the rank of Executive Engineer and equivalent in case of other government/private organization.
The intending bidder should be a CLASS-I/CLASS-II Electrical contractor. As a proof of this, valid electrical license issued by the competent authority of Govt. of Karnataka shall be uploaded
The intending bidder in his name should have achieved minimum average annual turnover of Rs.17.32Lakhs in at least any two financial years during the last five years(2021-22, 2022-23, 2023-24, 2024-25, 2025-26). As a proof of this, the bidder shall upload certified copy of the profit and loss account OR turn over certificate duly certified by Chartered Accountant.
₹500
₹36,684
23 Jun 2026
23 Jun 2026
9 Jul 2026
4 Jul 2026
30 Jun 2026
Supply and installation of junction boxes and Laying of Cables from ESP hoppers, MCC, Compressor Room and Slurry pump house to PLC at Units-5,6,7&8 AHP
Junction Boxes requirement at Unit-5&6 AHP at Bottom ash area SIZE 600(H)*600(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-5&6 AHP Dry System , SIZE 600(H)*600(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-5&6 AHP Wet System , SIZE 400(H)*500(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-5&6 AHP vacuum pump system, SIZE 400(H)*500(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-7 AHP Bottom ash area, SIZE 600(H)*500(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-7 AHP ESP, SIZE 600(H)*500(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Junction Boxes requirement at Unit-8 AHP ESP, SIZE 600(H)*500(W) ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Supply of Cable Glands ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Cable glanding and cable termination at local JB ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Mounting of junction boxes with required accessories and installation work ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Cable laying , rerouting from field instruments to new junction boxes ---- The bidder should visit RTPS site for the assessment of site condition before quoting the bid.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
TENDER DOC JB.pdf
Tender Document • 0.67 MB