Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.9 L+₹2.6 L (17.1%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹19.0 L+₹3.8 L (24.6%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹19.9 L+₹4.6 L (30.1%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹20.3 L+₹5.0 L (32.8%)Rejected-Finance MANGERIYA MANGERIYA BHOPALGARGH JODHPUR 342901 | JODHPUR | JODHPUR | RAJASTHAN | 342901 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
12 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR MAINT OF SECURITY LIGHT PERIMETER LIGHT CABLES JUNCTION AND ALLIED ITEMS IN ARMY ARMY BANAR
2023_MES_604431_1
8823/21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Banar
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹48,000
Yes
17 Aug 2023
20 Jun 2023
14 Jul 2023
20 Jun 2023
12 Jul 2023
5 Jul 2023
Amount
Supply, laying, testing & commissioing of 10 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including taking down old U/S cable complete all as specified. Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule.
All as per Ser No 1 above but size 16 sqmm 4 core
All as per Ser No 1 above but size 25 sqmm 4 core
All as per Ser No 1 above but size 35 sqmm 3.5 core
S&F in replacement of 40 mm dia GI pipe bracket (Light grade) bent to shape of length not less than 1.2 mtr including fixing on wall/pole using flat iron clamps of suitable size ,nuts,bolts,washers etc includig paint of two coats of alluminium paint over one coat of red oxide primer suitable for street light fittings complete all as specified.
Supply and fixing in replacement GI Pipe light grade 50 mm dia with necessary accessories/ fittings bracing with pol/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah and complete all as specified.
All as per ser item No 6 above but of size 40 mm dia
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified.
S & F in replacement of Street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel should be suitable enough to take SIngle Phase load of 5 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable one Nos power Contractors and one Nos incoming SPN of 40 Amp & 1 Nos outgoing SPN of 40 Amp & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for Manual operation (i.e. Sensor by Pass option) complete all as specified.
S & F in replacement of Street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel shuld be suitable enough to take 3 Phase load of 8 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable 3 Nos power Contractors and 03 Nos incoming MCB's & 3 Nos outgoing MCB's of 20-32 Amp each & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for Manual operation (i.e. Sensor by Pass option) complete all as specified.
Taking down defective street light/ flood light/post top lantern fitting of any size /type/capacity 45-150 Watt from height of pole/walls/high mast of any location up to 12M height for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified. Note :- (a) Spares like LED Driver,surge protector etc. shall be measured and paid as supply only separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost. (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site.
Supply only electronic driver for LED light fitting, LED out put power 45 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified.
All as per item No 12 above but capacity 75 watt
All as per item No 12 above capacity 100 watt
All as per item No 12 above capacity 150 watt
Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
Supply and fix in replacement of Street light PCB of 45 watts LED type fitting complete all as specified. Note: The LED PCB material is also required to fix inside casing of LED fitting.
All as per item No. 17 here-in-above, but suitable for 60 Watt LED type light fitting.
All as per item No. 17 here-in-above, but suitable for 90 Watt LED type light fitting.
Supply and fix in replacement of Flood light PCB of 150 watts LED type fitting complete all as specified. Note: The LED PCB material is also required to fix inside casing of LED fitting.
Labour only for making unserviceable street/security lights serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified. Note : - Cable shall be measured and paid for as "Supply only" here-in-after.
Supply only in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified.
M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified.
Supply and Fixing of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and complete all as specified.
M&L for painting black and white strips 05 Nos (each strips of 30 cm height) with synthetic enamel paint of black and white colour round the PCC/steel tubular pole alternatevely from the bottom of the pole and including writing numbering of pole with black paint on Yellow background complete all as specified.
Restringing only of overhead ACSR bare/insulated conductor of street / security light feeder including straightening properly on insulators and binding with aluminum taps /binding wire /conductor jumper etc complete all as specified.
S&F PVC seperators/spacers clamp mounted on ACSR conductor suitable for 2 run
Trimming and cutting of tree branches coming across LT over head line, clearing alround 3m the LT line and disposal of branches/bushes to a distance upto 50m and cleaning the site complete all as specified. Note :- (i) Length of span shall be 40 to 45m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible.(iii) Proper shut down will be taken from department and T&P will be provided by contractor.
Supply and fix in replacement pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified.
Supply and fix in replacement shackle type porcelain vitreous white insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel strap of size 31mm x 3mm , 12 mm dia insulators bolts, washers and nuts complete all as specified.
Supply and connecting in replacement PVC wire 10 sqmm nominal area 2 Core multi stranded aluminum conductor PVC sheathed and weather proof flat shape and drawn through PVC conduit/stretched on pole/srut/wall and connecting to Street light fitting on PCC/RCC/Steel pole and complete all as specified.
Supply and fixing in replacement of power contactor of 415 volts 50Hz, 40 Amp capacity with 230 volts operated coil on existing panel of highmast control panel and complete all as specified.
S&F in replacement of steel structure, as in cross arms, bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all as directed Including two coats of aluminium paints over & including M&L single coat of red oxide primer incl preparation of surface, complete all as specified.
Supply andd Fixing in replacement of 240V, 10KA 'C' curve miniature circuit breaker, SP 6 to 32 Amp capacity complete all as specified.
Supply andd Fixing in replacement 240V, 10KA 'C' curve miniature circuit breaker , SPN 40 Amps capacity complete all as specified.
Supply andd Fixing in replacement 415V, 10KA 'C' curve miniature circuit breaker, TPN 63 Amp capacity complete all as specified.
Supply and errecting in replacement of Prestressed concrete pole, 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the street light bracket/crossarms with connected items and street light fitting from old pole and refixing the same on new pole for street light fitting and all as required at site or complete all as specified.
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/8 SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as specified.
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situationand complete all as specified.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping with taking out the LT cables and GI pipe Etc and refixing in new coping or in any situation and complete all as specified.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified.
All as per item No 41 here in before but exc 1.5 mtr or part there of in depth beyond the first 1.5 mtr depth complete all as specified.
Material and labour for Sand cushioning/ Sand covering using Tibba sand for underground cable protection complete all as specified. Note :- For the purpose of payment, only punned thickness 18 cm will be measured.
Supply and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and complete all as specified.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified.
Sachiyay maa Electricals
M/s Vishaka Enterprises
Bhagwati Construction Company
M/s JOG SINGH MATERIALS
M/S RAKESH CHOUDHARY
INFINITY SOLAR SOLUTION
JASOL MAA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .