Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹6.5 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical 31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | RS COOLING APPLIANCES L1 | STANDARD ELECTRONICS L2 | Eastern Commerce L3 |
|---|---|---|---|---|---|---|
| 1.00Providing star rated (with applicable ISEER according current industry standard) floor mounting vertical split type AC machine of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity | ||||||
| 1.01 | 4.0 TR floor mounting vertical split type AC machine (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/hr or 14000 watt) | 5 | No | 1,19,000 ₹6.0 L | 1,20,000 ₹6 L | 1,21,600 ₹6.1 L |
| 2.00 | Standard installation, testing and commissioning of 4.0 TR floor mounting vertical split including hole cutting, finishing etc.(including supply and fitting of IDU stand ) as per direction of the Engineer-in-charge. | 5 | No | 4,000 ₹20,000 | 5,000 ₹25,000 | 4,900 ₹24,500 |
| 3.00 | Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 4.0TR vertical split AC as per manufacturer guideline ( 5/8” and 3/8” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units. | 40 | Mtr. | 590 ₹23,600 | 650 ₹26,000 | 1,000 ₹40,000 |
| 4.00 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 60 | Mtr. | 120 ₹7,200 | 120 ₹7,200 | 79 ₹4,740 |
| 5.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge | 5 | No | 900 ₹4,500 | 2,500 ₹12,500 | 1,900 ₹9,500 |
Tender Value
₹7.0 L
EMD Value
₹13,920
Closing Date
3 May 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical DivisionAgartala
Providing Installation Testing and Commissioning of split type air conditioning system in GA P and T Department 1st floor Secretariat Building Agartala
2025_CEPWD_60546_1
6_EE_DNIeT_MECH DIVN_AGT_2025_26
Open Tender
Electrical Works
60 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹13,920
2 Jun 2026
23 Apr 2025
3 May 2025
23 Apr 2025
3 May 2025
23 Apr 2025
Amount
Providing star rated (with applicable ISEER according current industry standard) floor mounting vertical split type AC machine of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
4.0 TR floor mounting vertical split type AC machine (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/hr or 14000 watt)
Standard installation, testing and commissioning of 4.0 TR floor mounting vertical split including hole cutting, finishing etc.(including supply and fitting of IDU stand ) as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 4.0TR vertical split AC as per manufacturer guideline ( 5/8” and 3/8” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge
STANDARD ELECTRONICS (BID ID -174330)
Eastern Commerce (BID ID -174371)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61578.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid