| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.8 L+₹39,303 (1.55%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹27.7 L+₹2.3 L (9.19%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹39.1 L+₹13.7 L (53.9%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹39.4 L+₹14.0 L (55.0%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
1 Jun 2022, 6:00 pmClosed
GE Dehu Road, Pune
GE Dehu Road, Pune
REWIRING AND REPAIRS TO FITTINGS FIXTURES OF MD OTM ACCN OF 105 AD 953 AD WKSP UNIT 763 DEMPSY ROAD ASC SUPPLY POINT UNDER GE DEHU ROAD
2022_MES_521320_1
8631
Open Tender
Civil Works
Item Rate
270 days
GE Dehu Road, Pune
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE Dehu Road, Pune
₹84,000
Yes
12 Jul 2022
2 May 2022
7 Jun 2022
2 May 2022
1 Jun 2022
17 May 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, but excluding light fitting etc. and making good disturbed surfaces of walls, floors, etc
M&L for point wiring with 1.5 sqmm single core multistranded copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked, surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for following:- Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
One light point controlled by one switch
One fan point controlled by one switch & regulators
One light point controlled by two way switches
One bell point controlled by one switch
One socket 5 pin 5 Amps flush type on same board
One socket 5 pin 5 Amps flush type on independent board
M&L for point wiring with 2.5 sqmm single core multistranded copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
S&F switch piano flush type single pole one way 5 Amps
S&F switch piano flush type single pole two way 5 Amps
S&F bell push, flush type single pole 5 Amps
S&F bell electric, AC 230 volts, single pole
S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings
S&F switch socket combination 2 in 1, 5 Amps flush type
S&F switch socket combination 2 in 1, 3 pin 5 Amps and 3 pin 15 Amps flush type universal.
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block
supply and fix regulator electronic step type for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
Supply and fix in repair LED Fitting with 22 Watts LED including provision of connections cable pvc unsheathed stranded copper conductor and pvc square block of size 80mmX80mm MODEL:LHEXBTP7IN1S022 MAKE :Havells or Equivalent in Philips/Bajaj/HPL
Supply and fix in repair LED Fitting with 9 Watts LED including provision of connections cable pvc unsheathed stranded copper conductor and pvc square block of size 80mmX80mm MODEL:LHEXBLP7IN1W009 MAKE :Havells or Equivalent in Philips/Bajaj/HPL
Supply and fix in repair LED T-5 Fitting with 24 Watts LED including provision of connections cable pvc unsheathed stranded copper conductor and pvc square block of size 80mmX80mm MODEL:LHEXACP7IN1S024 MAKE :Havells or Equivalent inPhilips/Luker/HPL
S&F in repair 45 W LED LOW BAY luminaire complete of CAT No SZHWGMX045 of Shakti or Equivalent /bajaj/havells
S&F in repair LED Recess cum surface panel LED fitting (Square/Round) 18 Watts CAT NO LHEAABP7IL1W018 of HAVELLS or eq in HPL/Bajaj/Philips
S&F in repair LED Recess mounted LED fitting 36/42 Watts CAT NO PLUTONEO2X2PLR34WLED840S of HAVELLS or HPLLEDEPN36WWS of HPL or LULT01S042XC/XN/XW of jaquar
S&F in repair LED Recess mounted LED fitting 18 Watts CAT NO LHEBHDP7IZ1W018 of HAVELLS or HPLLEDINS018WWR of HPL or LNRO02R018SW/SC/SN of Jaquar
S&F in repair LED Recess mounted LED fitting 18 Watts CAT NO LHEBAEP7IZ1W018 of HAVELLS or HPLLEDINS018WWS of HPL or LNRO02S018SW/SN/SC OF Jaquar
S&F in repair LED DRIVER CAT NO LSSLNW0171 of HAVELLS or Equivalent for LED Recess mounted LED fitting 24 Watts.
S&F in repair LED floodlight 100 watt integrated fitting with high luminous output and mounting bracket flood light with Die cast housing all as required at site IP 66 Rating CAT NO : HPLLEDFL10060WL of HPL or Eqivalent in Havells/Bajaj/Shakti
S & F in repair sheet metal enclosure single pole and neutral with two pin earth plug and socket complete including double pole MCB 20 amp 240 volt AC supply
S & F in repair submain wiring with cable insulated single core multistranded copper conductor FRLS cable 1100 volts 2x 4 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 4 sqmm copper conductor cable for earth continuity. (Note : 2 runs of 4 sqmm cable, one run of 4 sqmm earth cable and one run of PVC casing capping/conduit will be measured as one RM).
S & F in Repair submain wiring with cable insulated single core multistranded copper conductor FRLS cable 1100 volts 4x 6 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 2X 4 sqmm copper conductor cable for earth continuity . (Note 4 runs of 6 sqmm cable, two run of 4 sqmm earth cable and one run of PVC casing capping/conduit will be measured as one RM).
supply and fix in repair MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 12 way
-ditto- as per item No 26 above but 8 way
-ditto- as per item No 26 above but 6 way
-ditto- as per item No 26 above but 4 way
supply and fix in repair MCB DB TPN sheet metal enclosure double door Vertical type suitable for mounting MCB with 415 volts with 200 Amps rated busbar 12 way
-ditto- as per item No 30 above but 6 way
-ditto- as per item No 30 above but 4 way
Supply and fix in repair MCB SP 240 volts 6-32 Amps
Supply and fix in repair MCB SP 240 volts 40 Amps
Supply and fix in repair isolator SPN 40 Amps 240 volts
Supply and fix in repair MCB TP 40 Amps 240 volts
Supply and fix in repair isolator TPN 40 Amps 415 volts
Supply and fix in repair isolator TPN 63 Amps 415 volts
Supply and fix in repair isolator TPN 100 Amps 415 volts
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plare No 3,connected to earthing test point all as specified or indicated including testing on completion including excavation and earth work in any strata,PCC Chamber with cover,Charcoal and Salt as required & 15 mm Light Grade GI pipe from steel plate to DB in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3 ) mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth strip 25 X 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plare No 3,connected to earthing test point all as specified or indicated including testing on completion including excavation and earth work inany strata,PCC Chamber with cover,Charcoal and Salt as required in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge .
Supply and Fix 25 X 3 mm alumnium strip with saddles and fixing screws for roof and down conductors
supply and fix in repair 10 watt LED Bollard pressure die cast powder coated housing with diffuser of IP 65 protection CAT NO SZPGBMX010 of Shakti or Equivalent in havells/bajaj
S&F in replacement of decorative gate light made up of unbreakable polycarbonate suitable for retrofit LED lamp B22 base for mounting on pole /gate all as specified & directed by Engr-in-charge. Make :- LHFXBON1TN5Q008 of Havells or eq in bajaj/Wipro
S&F in replacement of LED Post top Prism made up of unbreakable polycarbonate suitable for mounting on pole /gate all as specified & directed by Engr-in-charge. Make :- SLE PT 6W-GP200 of Surya or eq in havells/bajaj
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 160 amp. MAKE:- C01604PEAV of HPL/Standard/Havellsor Equivalent
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 125 amp. MAKE:- C01254PEAV of HPL/Standard/Havellsor Equivalent
S&F in repair On load change over switch 415V,4 pole in sheet metal enclosure with current capacity 100 amp. MAKE:- CDC01004PEAV of HPL/Standard/Havellsor Equivalent.
S&F inrepair On load change over switch 415V,4 pole with in sheet metal enclosure current capacity 63 amp. MAKE:- CDC00634PEAV of HPL/Standard/Havellsor Equivalent.
Supply & fixing of SMC junction box (Top hinged door )of size 240 x 130 x 110 mm for controlling the street/security lights, with four aluminium busbar strips 200 Amps capacity with epoxy insulation fixed on PVC saddles with nut & bolts, cover with color coded caps (RYBB) with and including MCB SP 2.5 Amps capacity, complete all as directed. Make :- Sintex/ National/ L&T
Supply & fix in repair MCCB 200 Amp, 4 pole, 415 V,with breaking capacity 36 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 125 Amp, 4pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
Supply & fix in repair MCCB 63 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard
M&L in repair Fan capacitor 2.5 mfd for ceiling fan all as specified.
M&L in repair Fan capacitor 4 mfd for exhaust fan 9",12",15"all as specified and as directed by Engr-in-Charge.
S&F in repair 70 W LED HIGH BAY luminaire complete of CAT No SZHHCPX070 of Shakti or LHBLD1S070XC of Jaguar /Havells/HPL
M & L for disconncting the Mainpower supply from DB, taking down Electric KWH meter of any size,any type carefully & calibrate with proper load/ instruments in front of user & MES Rep, after proper calibration to refix with connection as per existing with sealed to meter complete all as specified. Note : i) All Qtr wise testing reports with sign of user & MES Rep kept in records. ii) if found faulty the rate for minor repair is included in this quoted rate.
Supply & fix in repair single phase KWH electric meter with LCD display of capacity 5-30 Amp, class 1 base mounting, AC, 50 Hz, 240 V complete all as specified. Make : L&T Cat Pat No. WM101BC5DL0 or equivalent in HPL,Schneider/ Siemens Note: Old meter will be deposited in MES store and old meter reading, new meter initial reading with date of installation & Qtr No. & Area all kept in records & handover to MES Incherge.
Supply & fix in repair AC three phase dual source with AC sencing, multifunction Energy meter of accuracy class 1.0, 3x240V, 50Hz, with optical + Modbus RS 485 communication, backlit LCD display of rating 10-60A. (Measures & displays, Active energy, load survey, TOD & power on/off Events). Make LT cat no WM301BC7D10 or equivalent in HPL,Schneider/ Siemens Note: Old meter will be deposited in MES store and old meter reading, new meter initial reading with date of installation & Qtr No. & Area all kept in records & handover to MES Incherge.
S&F in repair Meter box 2mm thick MS sheet powder coated of size1mtr x 1mtr X 0.25mtr split in two parts 0.4X 1 mtr on top for refixing the meters and .6X 1 mtr for fixing of MCCB and DB.The front portion should be provided with glass of size 10cm x 10cm infront of each meters to facilitate recording of meter reading and including provision of wooden block of suitable size to fix the meters and DBs, door with locking arrangement including Removing and refixing of meters .
S&F in repair deep spot light 03 watt for low ceiling application in red/blue/green colour. MAKE :- LHEEBCP1UN1B003 of havells or Eq in Philips/Jaquar
Supply and fixing multi core round PVC insulated aluminium conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 4 Sqmm, 2 core complete all as specified.
Supply and fixing multi core round PVC insulated aluminium conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 10 Sqmm, 2 core complete all as specified.
Material and labour for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including 2 nos MS clamps made out of 40mmX6mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size all as directed incl taking down of old unserviceable bracket.
Material and labour in replacement for LED Street lighting 30W LED IP66 New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium with lens and toughened glass type roadway luminaire with high power LEDs as light source including electronic driver 30W LED 6000K including making connection with three core aluminium conductor pvc cable from junction box/ overhead conductor to street light fitting all as specified. MAKE:- CAT PART NO LSTS-30-CDL-M of Crompton ,LR02-331-XXX-57-XX OF WIPRO/LHETBXU7PA1S030OF HAVELLS /LTRUMP0030XW of JAGUAR
Taking down U/S C/fan carefully & M&L for rewinding of ceiling fans of 1200 mm sweep of any make with super enamelled copper winding wire suitable guage and after cutting the old burnt winding and cleaning the slots including varnishing and replacement of flexible cable 23/0.0076 mm to the required length including making connection and testing including taking down complete all as specified.
All as per item no 68 above but exhaust fan 275 mm to 450 mm sweep
S & F in repair LED Suspended surface fittng (1 X 4 feet),of illumination100 lumen/watt,unifomly distributed light. Make :- RC380B LED32S-6500 L120W30 PSU OD of philips ,LSVR03S042XC of Jaquar / eq in Shakti
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make :- Havells/Luker/Wipro
Supply and fixing LED light fitting 1x 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified by Engr in charge. Make :- Sudhir/L&T
S & F in repair Flame Proof & Weather proof 8 way SPN DB made of CRCA sheet, RAL 9003, powder coated for IK-09 double door, IP-43 glazed door, confirms to IS-8623-1, IEC 61439-1&3, 240 v , ready to use DB insulated phase busbar, neutral bar's with shroud's, earth bar, sticking saddles, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates & circuit identification label with provision for DP, MCB/ Isolator/RCCB/RCBO as incomer & SP MCB's as outgoing all as specified Make: Sudhir/ L&T
Supply and fix in repair LED table lamp desklite lenear available with touch based on/off switch,adjustable lamp shade with 3 step dimming all as specified and directed by Engr in charge. Make :- LHEXBVP7SN1W005 of havells or eq in Bajaj/Wipro/Jaquar
Supply and fix in repair table light decorative type ,surface mounting,dome shapedpendant in green/black finishes all as specified and directed by Engr in charge . Make :- LHFHDPE1TN1G020 of havells or eq in Bajaj/Philips/Wipro
Supply and fix in repair wall mounting fitting,decorative type ,champagne finish fixture with plastic body suitable for 9 w LED lamp B22 base all as specified and directed by Engr in charge. Make :- LHFOAIC1TZ1I040 of havells or eq in Philips/wipro/Bajaj
M/S kirpan Enterprises
metro electrical services
vishwa Trading corporation
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .