Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.5 L+₹86,215 (8.09%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-AOC Not lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
COMPREHENSIVE MAINTENANCE OF MISCELLANEOUS E/M ASSETS IN DOMESTIC AREA AND SU (SITE 1A AND 1B) AT AF STN JODHPUR
2022_MES_538669_2
8529/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹20,000
Yes
27 Sept 2022
25 Aug 2022
16 Sept 2022
25 Aug 2022
14 Sept 2022
2 Sept 2022
Amount
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, ( fittings such as switches, ceiling roses, pendents, regulators, sockets etc.to be measured separately ) and removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes Complete all as specified and directed by Engineer-in-Charge.
Taking down submain wiring any type and any size complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for One light / fan point / exhaust fan point controlled by one switch 5 Amp, SP, one way 240 volts, with 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS) 1100 volts grade drawn through existing PVC/steel conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches sockets and fan regulator including 1.5 sqmm size PVC insulated unsheathed FRLS copper conductor multistranded cable for continuous earth conductor to common earth and connecting to earth dolly complete all as specified & directed by Engineer-in-Charge.
All as per Item Ser No 4.00 here-in-before but for 5 amp socket on same board
All as per Item Ser No 4.00 here-in-before but for 5 amp socket on independent board
All as per Item Ser No 4.00 here-in-before but for one bell point controlled by one bell push.
All as per item No. 4.00 here-in-before but with 2.5 Sqmm FRLS copper cable for independent 15 Amps socket outlet and including 1.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volt grade IS-694 FRLS cable for continous earth wire complete all as specified and directed by the Engineer in Charge.
Material and labour for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS-694 (Phase- Red/Blue/Yellow, Neutral - Black and earth continuity conductor - Green) drawn through and including PVC casing caping not less than 20mm x 12mm ISI marked ivory colour including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick phenolic laminated white sheet cover for mounting swiches and sockets complete for One light point / fan point controlled by one switch 5 amp one way complete all as specified and directed by the Engineer in Charge.
All as per Item Ser No 9.00 here-in-before but for 5 amp socket on same board
All as per Item Ser No 9.00 here-in-before but for 5 amp socket on independent board
All as per Item Ser No 9.00 here-in-before but for one bell point controlled by one bell push.
All as per item No. 9.00 here-in-before but with 2.5 Sqmm FRLS copper cable for independent 6 pin 5/15 Amps socket outlet and including 1.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volt grade IS-694 FRLS cable for continous earth wire complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs switch piano 5 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs switch piano 16 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs socket outlet flush type 5 pin 6 amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs socket outlet 2 in 1 flush type 5 pin 16 amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs bell push button flush type 5 Amps 240 V complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs of ding dong musical type, call bell AC 230V single pole complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular switches 6 Amps single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular sockets 6 Amps 5 pin complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular switches 16 Amps single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular socket 6/16Amp, three pin combined shuttered complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs modular fan steped type regulator, 2 module, 5 steps , 120W complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Steped type elecrtonic fan regulator flush type on the existing phenolic laminated sheet etc suitable for 240 volt complete all as specified and as directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through and including PVC casing & caping with necessary fittings, with one 4 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire, including making good the disturbed surface complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of casing caping shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 4 sqmm 1100 volt grade (ISI marked ) drawn through and including PVC casing & caping with necessary fittings, with one 2.5 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire, including making good the disturbed surface complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of casing caping shall be measured and paid as one length.
Supply & fixing in repairs MCBs of 'C' series, Single Pole (SP), 6 to 32 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series,Single Pole & Neutral (SPN), 40 to 63 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Triple Pole & Neutral (TPN), 40 to 100 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply and fixing factory made MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer in Charge.
Supply and fixing factory made MCB distribution board TPN, 440 volts, 4 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer in Charge.
Supply and fixing in repairs LED T5 batten 04 feet tube light fitting 1x18 Watt, 220 V , AC, decorative type connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engineer in Charge.
Supply and fixing in repairs energy efficient recessed mounted 36 Watt LED luminaire suitable for 600mm x 600mm grid ceiling with flat diffuser and lumen output of 3600 lumens colour temperature 3300K to 5300K having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified and directed by Engr-in-charge.
Taking down carefully and opening, dismantling of ceiling fans any sweep, cutting and taking out old burnt/damaged winding/material by any means and material & labour for re-winding the same with supper enamelled copper wire of existing/same SWG including all insulating material as required as per standard practice, varnishing the same and drying, cleaning fan with recommended quality grease/oil, re-assembling including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length and testing complete all as specified and directed by Engr-in-charge.
Taking down carefully and opening, dismantling of exhaust fan 450mm sweep and taking out old burnt/damaged winding/material by any means and material and labour for rewinding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan bearing/bushing and greasing/oiling the same with recommended quality grease/oil, reassembling and testing including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length complete all as specified and directed by Engr-in-charge.
All as per item No 36 herein above but exhaust fan 380 mm sweep all as specified & directed. Note for item no.35 to 37 :- Spare parts shall be measured and paid seperately under respective items of BOQ here in after as supply only.
Supply only bearing of ceiling/exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 2.5 MFD complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 4MFD complete all as specified and directed by Engineer-in-Charge.
Supply only bush suitable for ceiling/ exhaust fan any sweep and oiling complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking down old unserviceable KWH meter (Electric energy meter) "Single phase" from any situation and any description , repair the same with replacement of required/defective parts i.e LCD display, Electronic card, optical port, connection wires etc and make it functional & operational complete to the entire satisfaction of the Engineer-in-charge and re-fixing the same after repairing and electrically connection and testing complete.
Supply and fixing in repairs vitreous porcelain insulators on walls/ roofs in existing AL/Cu strip of any size complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning in repairs on load change over switch 100 Amps , four pole, 415 Volts, AC , 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge..
Material & labour for disconnecting, taking down and refixing the same after repair the geyser of any cap including striping, cutting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washer etc complete and including making good the existing disturbed surface with plastering and painting as per existing shade of walls complete all as specified and directed by Engineer-in-Charge. Note:- Spare parts if required to be replaced, shall be measured and paid seperately under srl item no.46 to 48 of BOQ here in after as supply only.
Supply only Heating Element of geyser of 1.5 KW rating including rubber washers complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat for the Geyser of 25/50 ltr capacity ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm/450 mm long and fixing in position suitable for Geyser of 25/50 Litre capacity complete all as specified and directed by Engineer-in-Charge.
Disconnecting, taking down, servicing, testing complete of Aqua RO machine any capacity from existing location and fixed at new or same location all as per specified and manufactures's instruction after servicing and replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts if required to be replace, shall be measured and paid seperately under srl item no. 50 to 58 of BOQ here in after as supply only.
Supply only suitable SMPS Adaptor 24 volt DC, 2.5 Amp for convert AC to DC supply complete all as specified and directed by Engineer-in-Charge.
Supply only SLC Solenoid Valve 24V SV complete all as specified and directed by Engineer-in-Charge.
Supply Only RO Booster Pump/Motor 100 GDP Suitable For all type of water purifier complete all as specified and directed by Engineer-in-Charge.
Supply Only High grade White pipe 1/4" for RO water Purifier complete all as specified and directed by Engineer-in-Charge.
Supply Only filter membrane 1500 TDS complete all as specified and directed by Engineer-in-Charge.
Supply only PP sediments filter 5 Macron complete all as specified and directed by Engineer-in-Charge.
Supply only carbon block fillter pre filter complete all as specified and directed by Engineer-in-Charge.
Supply only carbon block post filter complete all as specified and directed by Engineer-in-Charge.
Supply only water level sensor for controlling RO machine complete all as specified and directed by Engineer-in-Charge.
Material and labour for disconnecting, taking down from roof of the building and refixing the same after repair the heat exchanger of solar water heater with electrical backup of capacity 1000/2000 ltrs per day including striping, flush out the complete system to remove any floating and settled dirt, cleaning of tank etc complete all as specified and directed by the Engineer in Charge.
Supply & fixing in replacement Heating Element of 2 KW suitable for electrical backup for solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement Thermostat suitable for 1000/2000 litrs solar water heater complete all as specified and directed by Engineer-in-Charge.
Material, Labour and T&P for fault detection of non working existing Voltage stabilizers oil cooled/air cooled of different sizes at different locations attached including replacement of unserviceable spare parts under respective items given under the item as supply only including testing commissioning of the stabilizer on full load after necessary repair to the entire satisfaction of Engineer-in-Charge. Note :- Spare part used in repair work shall be measured and paid seprately under respective items as supply only given hereinafter and make of spare part shall be as existing Voltage stabilizers.
Supply only Push Button switch for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply only Auto manual switch for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply only Micro switch for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply only Trigger Transformer for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply only Rotary Switch 5 Amp for R Y B Phases for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply only Shunt transformer for existing Voltage stabilizers oil cooled/Air cooled of exiting make at site.
Supply & fixing in repairs Electronic circuit card (PCB) of any type i.e. single display/ double display and any size of stablizer as required complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repairs 12 Volt 7 AH capacity Battery suitable for Automatic Fire Detection & Alarm System Complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs non addressable type Photo Electric Smoke/heat Detector suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge.
Supply and fixing in repairs addressable type Smoke/heat Detector suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge.
Supply and fixing in repairs Manual Call Point (Pill Box) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer-in-charge.
Supply and fixing in repairs addressable type Manual Call Point (Pill Box, Aluminium Body) with extra key suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer-in-charge.
Supply and fixing in repairs Hooter capable to work on 24 DC Volt suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer in charge.
Supply and fixing in repairs addressable type Hooter with indicator light capable to work on 24 DC Volt suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer-in-charge.
Supply and fixing in repairs Response Indicator (RI) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer-in-charge.
Supply and fixing in repairs Complete FIRE ALARM PANEL non addressable type 04 zone with all accessories suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by the Engineer-in-charge.
Material and labour for rewiring of faulty area of fire alarm system zone wise, rewiring with 1.5 Sqmm (nominal area) PVC insulated and PVC unsheathed FRLS cable, stranded copper conductor with and including steel rigid conduit 20 mm dia medium grade ISI marked with all fittings and accessories complete all as specified & directed by Engineer-in-Charge.
Supply and laying in replacement GI pipes 50 mm bore medium grade with all fittings, fixed to walls/floors etc including clapms, nuts & bolts etc complete all as specified and directed by Engineer -in-Charge.
Supply and laying in replacement GI pipes 25 mm bore medium grade with all fittings, fixed to walls/floors etc including clapms, nuts & bolts etc complete all as specified and directed by Engineer -in-Charge.
Supply and laying in replacement GI pipes 20 mm bore medium grade with all fittings, fixed to walls/floors etc including clapms, nuts & bolts etc complete all as specified and directed by Engineer -in-Charge.
Supply and fixing in repairs 25mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe or for unions and fixing complete all as specified and directed by Engineer -in-Charge.
Supply and fixing in repairs 20mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe or for unions and fixing complete all as specified and directed by Engineer -in-Charge.
Supply and fixing in repairs 15mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe or for unions and fixing complete all as specified and directed by Engineer -in-Charge.
Material & labour for taking out Centrifugal pump of 30 HP from foundation by disconnecting suction & delivery pipe line, dismantling of pump, overhauling the same by repairing/replacing defective parts as ordered and reassembling, replacement of worn out nuts, bolts, repairing of bearing housing complete including greasing and making connection complete all as specifed and direceted by Engineer-in-Charge. Note : Spare parts will be measured and paid separately as given here-in-after.
Supply only ball bearing DE + NDE for centrifugal pump 30HP complete.
Supply only Gun Metal bush for centrifugal pump 30HP complete.
Supply only MS coupling set for pump & motor with pin for centrifugal pump 30HP complete.
Material & labour for taking out Centrifugal pump of 5 HP from foundation by disconnecting suction & delivery pipe line, dismantling of pump, overhauling the same by repairing/replacing defective parts as ordered and reassembling, replacement of worn out nuts, bolts, repairing of bearing housing complete including greasing and making connection complete all as per specifed and direceted by Engineer-in-Charge. Note : Spare parts will be measured and paid separately as given here-in-after.
Supply only ball bearing DE + NDE for centrifugal pump 05 HP complete.
Supply only Gun Metal bush for centrifugal pump 05 HP complete.
Supply only MS coupling set for pump & motor with pin for centrifugal pump 05 HP complete.
Material and labour for finding out leakage of water pipe line from Takhat Sagar Pump House to Site 1A Pump House and repairing the leakage by fixing seal, clamp etc of suitable size complete all as specified & directed by Engineer-in charge.
Material and labour for taking out electric motor 30HP capacity, AC 3 phase 415 volts from foundation, transportation to work shop, dismantling the motor, taking out old burnt wiring, cleaning the starter slots, material and labour for rewinding the stator with appropriate gauge super enameled copper wire and installation paper, sleeves, thimbles etc, complete varnishing and backing up the windings, repairs to bearing housings, replacing the bearings, cooling fan and connection plate, taking back to site, fixing on foundation making electric connection, realigning with pump/motor and testing complete as directed by Engr-in charge.
Material and labour for taking out electric motor 5HP capacity, AC 3 phase 415 volts from foundation, transportation to work shop, dismantling the motor, taking out old burnt wiring, cleaning the starter slots, material and labour for rewinding the stator with appropriate gauge super enameled copper wire and installation paper, sleeves, thimbles etc, complete varnishing and backing up the windings, repairs to bearing housings, replacing the bearings, cooling fan and connection plate, taking back to site, fixing on foundation making electric connection, realigning with pump/motor and testing complete as directed by Engr-in charge.
Supply and fixing in repairs single pointed air termination Aluminium rod 12mm dia 300 mm long complete all as specified & directed by Engineer-in charge.
Supply & fixing in repairs Aluminium strip 25mmx3.15mm complete with saddles and fixing screws for fitting the strip including AI / SS / GI pipe fabrication support structure providing with suitable base plate should have provision for termination arrangement for the Down conductor complete all as specified & directed by Engineer-in charge.
Supply & fixing in repairs GI strip 32mmx6mm complete with, protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg (wall, roof or ground) complete all as specified & directed by Engineer-in charge.
Material & labour PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate for Thrust block of required size as per site at SU Site1A (takhatsagar pumphouse to kailana pump house) for supporting of GI/DI/CI pipe to be used for water supply including dismantling the old unserviceable PCC complete all as specified & directed by Engineer-in charge. Note:- Pipe to be properly fixed by PCC etc on thrust block.
Supply & fixing in replacement of rotational moulded polyethylene water storage tanks 50 litrs (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs DOL starter 3 phase suitable for 5 HP pump complete all as specified & directed by Engineer-in charge.
Supply & fixing in repairs star delta starter 3 phase suitable for 30 HP pump complete all as specified & directed by Engineer-in charge.
Nvimal Engineers and Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .