| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC low bid | |
| 2 | L2₹18.4 L+₹3.5 L (23.7%)Rejected-Finance | L2 | Rejected-Finance high bid | |
| 3 | L3₹19.1 L+₹4.2 L (28.1%)Rejected-Finance | L3 | Rejected-Finance High bid |
| Sl No | Description | Qty | Unit | Lakshay Enterprises L1 | The Drishti Co-Operative Labour and Construction Society Limited Sonepat L2 | The Ujjwal Haryana Co-op L and C Society Ltd L3 |
|---|---|---|---|---|---|---|
| 1.00 | Procelain LT shackle insulator for electrical installation | 300 | Piece | 10 ₹3,000 Lowest | 12 ₹3,600 | 10 ₹3,000 Lowest |
| 2.00 | 2mm spot cum insulated clutch G.I. wire | 7,000 | Metre | 8 ₹56,000 Lowest | 9 ₹63,000 | 8 ₹56,000 Lowest |
| 3.00 | Maintenence of all wattage and all types of LED lights with all accessories with labour per light. | 23,700 | Each | 24 ₹5,68,800 Lowest | 30 ₹7,11,000 | 24 ₹5,68,800 Lowest |
| 4.00 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated
pressure die cast aluminum body with driver as per the requirement with Driver efficiency
)85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to
50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver
efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80,
under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam
angle as per IESNA type I/II/III as per the width of the road and the project requirement.,
suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum
50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As
per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power
consumption should not more than the specified rating and Fixture shall be of relevant
BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated
copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test
report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted.
Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
(Thermal management: heat sink of aluminum housing such that LED junction
temperature shall not rise above 90°C). 45 watt | 100 | Each | 1,450 ₹1,45,000 | 1,600 ₹1,60,000 | 1,410 ₹1,41,000 Lowest |
| 5.00 | Supply and Erection of D-straps complete all respect | 300 | Each | 65 ₹19,500 Lowest | 75 ₹22,500 | 67 ₹20,100 |
Tender Value
₹16.3 L
EMD Value
₹32,000
Closing Date
7 Jul 2026, 9:00 amClosed
MANJEET DAHIYA
Municipal Committee Kundli
Supply and Erection of cable, operation and maintenance of all wattage and all types of LED lights in MC Kundli for one year only.
2026_HRY_532415_1
2026C97425D0 DA48 4315 AB9D 681729D211CC1676ULB
Open Tender
Civil Works
Works
360 days
Kundli(MC)
2 documents required · 2 mandatory
₹1,000
Yes
₹32,000
Yes
8 Oct 2026
30 Jun 2026
7 Jul 2026
30 Jun 2026
7 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Procelain LT shackle insulator for electrical installation | - | Piece | - | - |
| 2 | 2mm spot cum insulated clutch G.I. wire | - | Metre | - | - |
| 3 | Maintenence of all wattage and all types of LED lights with all accessories with labour per light. | - | Each | - | - |
| 4 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated
pressure die cast aluminum body with driver as per the requirement with Driver efficiency
)85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to
50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver
efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80,
under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam
angle as per IESNA type I/II/III as per the width of the road and the project requirement.,
suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum
50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As
per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power
consumption should not more than the specified rating and Fixture shall be of relevant
BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated
copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test
report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted.
Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
(Thermal management: heat sink of aluminum housing such that LED junction
temperature shall not rise above 90°C). 45 watt | - | Each | - | - |
| 5 | Supply and Erection of D-straps complete all respect | - | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_611479.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .