commissioner
MUNICIPAL CORPORATION KOTA
Shifting Underground of HT LT Line on proposed road from Jawahar nagar main road Anil kothari clinic to MBS Road in Municipal Corporation Kota
2026_DLB_590126_1
NNK/ELECTRIC/2026/1332-1339
Open Tender
Electrical Works
Percentage
180 days
kota
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,500
commissioner
₹16.1 L
Yes
20 Aug 2026
20 Aug 2026
7 Sept 2026
20 Aug 2026
7 Sept 2026
20 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1WORK NAME | |||||
| 1.01 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed
Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -
I of 1.1 KV with H4- Grade electrolytic aluminium conductor
confirming to IS 8130 of purity >99.6 %, round / flat strip armouring
of cables, Inner / outer sheath confirming to IS:5831 in existing RCC
/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable
tray(with cable tie) including testing etc. as required of following
size. OEM must have it's own in house NABL accrediated
Laboratory for testing procedure as per IS:10810.For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR 185.0 Sq. mm 3.5 Core 300.0 Sq. mm | 5,212 | Mtr | 1,450 | ₹75,57,400 |
| 1.02 | 3.5 core | 1,000 | Mtr | 2,165 | ₹21,65,000 |
| 1.03 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 4.0 Sq. mm 2 core | 3,000 | Mtr | 112 | ₹3,36,000 |
| 1.04 | 16.0 Sq. mm 4 core | 1,000 | Mtr | 238 | ₹2,38,000 |
| 1.05 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR3 core 95.0 Sq.mm | 1,000 | Mtr | 1,319 | ₹13,19,000 |
| 1.06 | 3 core 300.0 Sq.mm | 5,000 | mtr | 2,757 | ₹1,37,85,000 |
| 1.07 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .3 core 300.0 Sq.mm | 2,000 | mtr | 4,058 | ₹81,16,000 |
| 1.08 | SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC
Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch | 45 | Each | 4,77,527 | ₹2,14,88,715 |
| 1.09 | Non Extensible 1 way RMU with 1 no. VCB & Direct Cable Entry | 4 | Each | 3,49,236 | ₹13,96,944 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
13321.pdf
Tender Documents • 2.13 MB
BOQ_1047956.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].