Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.0 L+₹92,604 (2.64%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹37.5 L+₹2.4 L (6.89%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹37.9 L+₹2.8 L (7.99%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.0 L+₹4.0 L (11.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
14 Feb 2024, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
CONVERSION OF LT OVERHEAD LINE INTO UG CABLE AT MH AMBALA UNDER GE UTILITY AMBALA CANTT
2024_MES_637827_1
CA NO GE U AMB T 71 OF 2023-24
Open Tender
Civil Works
Item Rate
150 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE UTILITY AMBALA CANTT
₹87,000
Yes
12 Mar 2024
17 Jan 2024
16 Feb 2024
17 Jan 2024
14 Feb 2024
31 Jan 2024
17 Jan 2024 - 24 Jan 2024
Amount
Dismantling of ACSR/AAC conductors from existing O/H line complete all as specified and directed
Dismantling earth wire from existing O/H line complete all as specified and directed
Dismantling stay assembly complete all as specified and directed
Dismantling cross-arms of M S channel or angle sections etc and setting aside for reuse with in 50m complete all as specified and directed
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in any type of soil for laying of cables, foundation of poles,locating fault of LT Cable and stay assembly all as specified and directed .
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick all as specified and directed .
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge
M&L for dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15CM thick after laying and stretching of cable(Punned down 18cm) all a specified. Note: Punned thickness shall be 18 cm and the same shall be considered for payment.
M&L for sub class 'B' brick for covering to under ground cable laid dry flat transversally width equal to the length of the cable all as specified and directed.
Material & labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type D2, 1:4:8 using 40 mm graded stone agregate as foundations to poles all as specified.
Material & labour for Cement concrete, filling and mass concrete, PCC type C2, 1:3:6 using 20 mm graded aggregate all as specified.
Material & labour for cement concrete as coping to poles, PCC type B1, 1:2:4 using 20 mm graded stone agregate as foundations to poles all as specified.
M & L for horizontal boring under Road, pavement, hard standing complete with inserting GI pipe light grade of size 50/80mm dia all as specified and directed. Note :- GI pipe shall be measured and paid seperately
Supply and laying , connecting and testing XPLE armoured cable underground insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note : (i) Earth work, sand cushioning, brick protection , removing, returning filling Aluminium thimbles/lugs will be paid seperately. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.Cable of following size:-
(a) Cross section area 16 Sq mm 4.0 core
(b) Cross section area 25 Sq mm 3.5 core
(c) Cross section area 50 Sq mm 3.5 core
(d) Cross section area 70 Sq mm 3.5 core
(e) Cross section area 95 Sq mm 3.5 core
(f) Cross section area 120 Sq mm 3.5 core
(g) Cross section area 185 Sq mm 3.5 core
(h) Cross section area 240 Sq mm 3.5 core
(j) Cross section area 300 Sq mm 3.5 core
(k) Cross section area 400 Sq mm 3.5 core
Supply and fixing of GI tubing 80 mm bore light grade on poles, on walls under floors, road crossing as reqd as site complete all as directed by Engr-in-Charge.
Supply and fixing of GI tubing 50 mm bore light grade on poles, on walls under floors, road crossing as reqd as site complete all as directed by Engr-in-Charge.
Supply and fixing of GI tubing 40 mm bore light grade on poles, on walls under floors, road crossing as reqd as site complete all as directed by Engr-in-Charge. Note for serial item 15 to 17 : Clamps. Nuts bolts, saddle etc shall be measured and paid seperately.
Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. Note: (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost.
Supply, installation and testing of LT Panel of size 1.5 metre x 1.2 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 1200 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 1200 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near NICU (a) Incoming MCCB 4 pole 800 Amps 50 KA(Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 630 Amps 50 KA ( Fixed TM type) - 01 Nos ( c) Outgoing MCCB 4 pole 100 Amps 10 KA ( Fixed TM type) - 03 Nos (d) Volt meter 0 to 500 Volts, digital type – 01 No (e) Amp meter 0 to 800 Amp digital type -01 No. (f) Indicating lamp LED type one set in incoming phases. (g) CT Coils of suitable ratio-01 Set. Make-AE (h) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.2 metre x 1.0 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 1000 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 1000 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near Hosp Lab. (a) Incoming MCCB 4 pole 630 Amps 50 KA (Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 500 Amps 36 KA ( Fixed TM type) - 01 Nos ( c) Outgoing MCCB 4 pole 125 Amps 16 KA ( Fixed TM type) - 01 Nos (d) Outgoing MCCB 4 pole 160 Amps 16 KA ( Fixed TM type)- 01 Nos (e ) OutgoingMCB TPN C curve 40 Amps- 03 Nos (f) Volt meter 0 to 500 Volts, digital type – 01 No (g) Amp meter 0 to 500 Amp digital type -01 No. (h) Indicating lamp LED type one set in incoming phases. (j) CT Coils of suitable ratio-01 Set. Make-AE (k) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.2 metre x 1.0 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 600 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 600 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near Gurudwara. (a) Incoming MCCB 4 pole 400 Amps 36 KA (Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 125 Amps 16 KA ( Fixed TM type) - 01 Nos ( c) Outgoing MCCB 4 pole 315 Amps 36 KA ( Fixed TM type) - 01 Nos (d)Outgoing MCB TPN 4 pole 40 Amps - 02 Nos (f) Volt meter 0 to 500 Volts, digital type – 01 No (g) Amp meter 0 to 400 Amp digital type -01 No. (h) Indicating lamp LED type one set in incoming phases. (j) CT Coils of suitable ratio-01 Set. Make-AE (k) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.0 metre x 0.8 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 200 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 200 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near Adm Block. (a) Incoming MCCB 4 pole 125 Amps 16 KA (Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 100 Amps 10 KA ( Fixed TM type)- 03 Nos (c) Volt meter 0 to 500 Volts, digital type – 01 No (d) Amp meter 0 to 200 Amp digital type -01 No. (e) Indicating lamp LED type one set in incoming phases. (f) CT Coils of suitable ratio-01 Set. Make-AE (g) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.0 metre x 0.8 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 200 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 200 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near Med Div. (a) Incoming MCCB 4 pole 125 Amps 16 KA (Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 100 Amps 16 KA ( Fixed TM type) - 02 Nos ( c) Outgoing MCB TPN c curve 40 Amps - 01 Nos (d) Volt meter 0 to 500 Volts, digital type – 01 No (e) Amp meter 0 to 100 Amp digital type -01 No. (f) Indicating lamp LED type one set in incoming phases. (g) CT Coils of suitable ratio-01 Set. Make-AE (h) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.0 metre x 0.8 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 150 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 150 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc-Near MT Barrack. (a) Incoming MCCB 4 pole 100 Amps 16 KA (Adjustable TM type) - 01 No. (b) Outgoing MCB TPN c curve 40 Amps - 01 Nos ( c) OutgoingMCB SPN C curve 6 Amp - 13 Nos (d) Volt meter 0 to 500 Volts, digital type – 01 No (e) Amp meter 0 to 100 Amp digital type -01 No. (f) Indicating lamp LED type one set in incoming phases. (g) CT Coils of suitable ratio-01 Set. Make-AE (h) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.2 metre x 1.0 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 350 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 350 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc-Near CT Scan. (a) Incoming MCCB 4 pole 250 Amps 25 KA (Adjustable TM type) - 01 No. (b) MCCB 4 pole 125 Amps 16 KA ( Fixed TM type) - 01 Nos ( c) Outgoing MCB TPN C curve 40 Amps - 03 Nos (d)Outgoing MCCB 4 pole 160 Amps 16 KA - 01 Nos (e) Volt meter 0 to 500 Volts, digital type – 01 No (f) Amp meter 0 to 300 Amp digital type -01 No. (g) Indicating lamp LED type one set in incoming phases. (h) CT Coils of suitable ratio-01 Set. Make-AE (j) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 1.0 metre x 0.8 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 180 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 180 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc- Near MRI. (a) Incoming MCCB 4 pole 125 Amps 16 KA(Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 100 Amps 10 KA ( Fixed TM type) - 01 Nos ( c) Outgoing MCB TPN C curve 63 Amps - 02 Nos (d) Volt meter 0 to 500 Volts, digital type – 01 No (e) Amp meter 0 to 100 Amp digital type -01 No. (f) Indicating lamp LED type one set in incoming phases. (g) CT Coils of suitable ratio-01 Set. Make-AE (h) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
Supply, installation and testing of LT Panel of size 0.8 metre x 0.8 metre x 0.5 metre, weather proof, outdoor type,degree of protection IP-56, having sheet thickness of 3.15mm and inner shell made out of 2mm thick CRCA sheet and MS angle size 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door perspex sheet with MS frame of size 35 x 35 x 5 mm system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar 150 Amp tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction of LT panel shall be tested from CPRI type test for 150 Amp with breaking capacity not less than 65 KA and IP 56 as confirming to IS- 61439/2011 Part I and Part 2 type test certificate comprising of the following :-Loc-Near Blood Bank. (a) Incoming MCCB 4 pole 100 Amps 16 KA (Adjustable TM type) - 01 No. (b) Outgoing MCCB 4 pole 25 Amps 10 KA ( Fixed TM type) - 01 Nos (c) Out going MCB TPN C curve 4 pole 40 Amps - 02 Nos (d) Outgoing MCB TPN C curve 10 Amps - 02 Nos (e) Volt meter 0 to 500 Volts, digital type – 01 No (f) Amp meter 0 to 100 Amps digital type -01 No. (g) Indicating lamp LED type one set in incoming phases. (h) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (j) CT Coils of suitable ratio-01 Set. Make-AE
NOTE :- Item No 19 to 27 (i) The quoted rate shall includes minor items such as lugs, SS nuts bolts & washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be approved before placing of order from Accepting officer . (iv) The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating busbar strip type duly insulated.
Sypply, Install, Test and Commissioning of LT feeder piller box outdoor type fabricated of size 0.6x0.6x0.5M,out of 3.00 mm thick CRCA sheet, CPRI approved complete with powder coating with seven tank process mounted on MS angle frame of size 40x40x5mm, duly grounted with PCC using concrete 1:2:4 type B-1 reqd with the following. (a) S & F copper bus bar 200 Amp with coloured heat shrinkable insulated sleeve 415 volts as per IS of suitable size mounted on DMC/epoxy insulator (not than 50mmx50mm conicle type at a maximum interval of 500 mm - 01 Set. (b) S&F MCB TPN C curve 63 Amps - 01 No For Main incoming (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) Panel drawing shall be got approved before placing of order from Accepting officer. (iii) The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (iv) Cost of making description on the front door as per direction of Engr-in-Charge is encl in quoted rate. (v) Cable will be entered in panles through gland.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular,cable size 10 sqmm twin core stranded conductor incl saddles complete all as directed by engr-in-charge.
Taking down and Supply erection (in true vertical position) Steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screws all as specified of type 410 SP-31 ( 9.0 mtr length) complete all as specified in IS 2713 (Part-II) 1980 including one coat of red oxide primer and two coats of aluminium paint to exposed surfaces incl providing of two coats of black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip and with black bituminus paint for embedded portion of pole compete all as specified and as directed by Engr-in-Charge. Note:- (i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, watt etc.
Supply and fixing TPN 63 Amp Copper Bus Bar chamberwith 4 outgoing ways IP42,step type design, single door type fixed on wall , making good of disturbed surfaces and matching with existing and electrical connections complete all as specified and directed by Engineer-in-Charge
Note:- Amount of credit of Rs 50900.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
M/s Friends Engineering Works
Raman Electric Trading Co
R D Bansal
AR CONSTRUCTIONS
M/S Sonu Traders
Esha Engineers
Durga Electricals
UNITED ENGINEERING CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .