SE ETC GONDA
220 KV Substation Gonda Campus, Jail Road Gonda.
Work
2025_UPTCL_1051775_1
03/ETC(GD)/2025-26
Open Tender
Electrical Works
Fixed-rate
45 days
Bahraich
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
EE ETD GONDA
₹7,100
22 Aug 2025
28 Jun 2025
25 Jul 2025
28 Jun 2025
25 Jul 2025
28 Jun 2025
Amount
Troubleshooting/rectification/restoration/configuration of the Siemens make SCADA System installed at 132 KV Sub-Station Payagpur.
SCADA HMI Troubleshooting/rectification of the Siemens make SCADA substation Automation System installed at 132 KV Sub-Station Payagpur, The following work included to make SCADA System Healthy (A) Replacing the defective Fiber patch cords/CAT-5 cables, if any. (B) Checking & rectifying the healthiness of IEC61850-3 compliance Ethernet Switches. (C) Rectification /checking healthiness of the old backup installed at the system, if any. (D)Checking the all-healthiness communication in between protection relays and SCADA system. (E) Checking the SLD communication failure on SCADA HMI. F) Checking the real time Analogue Values on the SCADA System. (G) Checking and rectifying the control command issues from SCADA to BCPUs, if any. subject to CB /ISO must be control from the respective BCPUs. (H) Installation of OS window 10 (Long time support) and updated HMI (WinCC+SCC) (J) Reinstallation of old backup in Main and Standby sever SCADA HMI-I & HMI-II if required. All above required mentioned material will be provided by the contractor.
Bay Integration/configuration in the existing SEL make SCADA of 33kV Line Feeders, Work Includes as below: (A) Creation of Single line Diagram(SLD) Graphics. (B) Database point configuration as per the existing database version 7.11. (C) Alarm/EVENT/REPORT templates veneration. (D) Real time report page generation for Hourly/daily/monthly). (E) Soft Interlock logics templates generation. (F) Buffered/Un-buffered Report Control Block updation as per the BCPUs files. Following are the details of 33 KV Bays for integration/configuration. 1. 33 kV Chiraiya Tand Bay No-311 (ABB make C&R Panel) DOC 05.07.2021 2. 33 kV Dhanuhi Bay No-312 (ABB make C&R Panel) DOC 26.12.2020
Mapping/Configuration of the ICD files variables of IEC61850 base relays in existing database software of feeder bays. (01 Job includes 01 Relay per Bay work)
Gateway Configuration and testing validation work of the above mentioned feeders to send the real time data to SLDC Lucknow and SLDC Modipuram.
Supply and installation Various type of Fiber patch LC to LC, LC to ST MM patch cords of different lengths as required.
exSel Corporation (BID ID -5372146)
AR POWER AUTOMATION (BID ID -5373779)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .