| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 CrAccepted-AOC | ₹2.9 Cr | 1 | Accepted-AOC L1 |
Tender Value
₹2.7 Cr
EMD Value
₹1 L
Closing Date
19 Oct 2023, 4:00 pmClosed
Superintending Engineer
PH Circle, KWA, Kozhikode
AMRUT Medical College AMRUT 1 Laying 355 mm HDPE pipe from Iringaadanpally bypass junction to Medical college as alternate watersupply
2023_KWA_612296_1
SE/PHC/KKD/83/2023-24
Open Tender
Civil Works - Others
Item Rate
150 days
Kozhikode
7 documents required · 7 mandatory
₹8,270
₹1 L
1 Aug 2024
11 Oct 2023
20 Oct 2023
11 Oct 2023
19 Oct 2023
11 Oct 2023
Amount
Laying of 355mm HDPE pipe
100.98.185:Supply of HDPE Pipe PE 100 (IS 4984/1995), 12.5kg, 355mm Outer Dia.
OD161232/2023-2024:Add 5% for PE specials
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.
100.98.467:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 500mm.
OD141361/2023-2024:Supply of Flanged type 300mm water meter with 300mm CI Y strainer Specification:Dirt box filter made of Cast iron body with matching flanged ends housing a protective SS basket for filtering and protecting water meter from getting damaged by solid particles in water.With completely removable mechanism suitable for easy installation,cleaning ,and periodical maintenance without removing meter from the supply line.
OD141362/2023-2024:Supply of Flanged type 250mm water meter with 250mm CI Y strainer. Specification:Dirt box filter made of Cast iron body with matching flanged ends housing a protective SS basket for filtering and protecting water meter from getting damaged by solid particles in water.With completely removable mechanism suitable for easy installation,cleaning ,and periodical maintenance without removing meter from the supply line.
OD141363/2023-2024:Supply of Flanged type 100mm water meter with 100mm CI Y strainer. Specification:Dirt box filter made of Cast iron body with matching flanged ends housing a protective SS basket for filtering and protecting water meter from getting damaged by solid particles in water.With completely removable mechanism suitable for easy installation,cleaning ,and periodical maintenance without removing meter from the supply line.
OD141349/2023-2024:Supplying of Electro Magnetic Flow Meter 500 mm conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/ neoprene all confirming to drinking water standards. The flow meter should coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standers as per ISO 17025 and the product shall have sufficient warranty provisions. Asper circular No.KWA/HO/SP-4014/2012/Flow meter and Soft starter dated 5.9.2012(Add 15%) including fixing charge as CP charges.
OD141350/2023-2024:Supplying of Electro Magnetic Flow Meter 600 mm conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/ neoprene all confirming to drinking water standards. The flow meter should coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standers as per ISO 17025 and the product shall have sufficient warranty provisions. Asper circular No.KWA/HO/SP-4014/2012/Flow meter and Soft starter dated 5.9.2012(Add 15%) including fixing charge as CP charges.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
OD56374/2023-2024:Push through / HDD 600 mm dia MS pipe for crossing PWD BM and BC road, Without making damages to any exisiting structures by adopting reuired equipment,s and labour charges etc
100.31.1.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class I.
OD59256/2023-2024:Laying HDPE pipes (IS : 4984) on land portion including conveying within initial lead and aligning the pipes, butt-fusion welding using automatic or semi-automatic buttfusion machines, testing the pipeline thus fabricated to suit the hydraulic working pressure and after testing, aligning the pipeline, lowering the pipe in position into the trenches already made, testing the line to suitable pressure with potable water before back filling and levelling the trenches including all labour charge, hire for appliances etc., complete but excluding cost of pipe and fittings: 355mm Nominal Outside Diameter Pipes.
100.31.1.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class I.
OD59310/2023-2024:Supply & Installation of Control Panel for Electromagnetic Flow Meter. SS Panel for flow meter with 8hr power backup, plotter for the output data.GPRS/GSM connections, connections from service providers, 5 year connection maintenance charge etc. Stainless steel of 500X500x1000mm flow transmitter, GPRS modem for logging and transmittingthe readings. Main supply to be taken with suitable sizes of UG cable of required length also will be provided and ther should be power backup/UPS for 8hrs when power failure occurs. Panel dimension: 500(w)*500(D)*1000(H) MOC: SS Modem :GPRS Type Input power supply:24VDC No. of I/Os: 2DI, 2 AI for flow rate and total consumption. The current flow rate and total consumption should transmit via SMS to the certain CUG numbers in every 1 hour.
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
OD59353/2023-2024:Interconnection of 500mm DI pipe to 355mm HDPE pipe. The section details for interconnection is mentioned in the attached drawing with necessary valves and water meter including chamber sizes.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Road restoration
3.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m <br> Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. <br> (i) For Grading I Material
4.9:Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
5.1.1a:Prime Coat :- Low porosity <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a:Tack Coat <br>Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 <br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means :- Case - III : Type C <br> (II) Bitumen (S-65)
Bidder Name
SAMEER ALI CT
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .