Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
24 Jul 2026, 3:00 pm
Provision of additional display Boards (i.e. True colour OVD, PDB and AGDB) at Tatanagar, Chakradharpur, Rourkela, Jharsuguda Stations.
ST-CKP-OT-26-27-47
ST-CKP-OT-26-27-47
Open
6 Months
Jharsuguda, Odisha
₹0
₹4.0 L
30 Jun 2026
30 Jun 2026
10 Jul 2026
Item Breakup - A-Execution
Excavation of trench in all kinds of soils Kilometre including soft rocky area and clearing of roots of trees, rocks, bushes, ballast & reconditioning etc., including bailing out water and disposal of extra soil including back filling with excavated earth and ramming of trenches after cable laying for the following depths and widths as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER or any other latest guidelines. Note: In case, trenches are other than prescribed depth & width, Proportionate payment shall be released. (i) Depth 1.0 meter, Width 0.3 meter.
Laying of S&T Cables (Signal/Quad/Power) in Kilometre the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports.
Laying of OFC/ Power cable/ CAT-6 cable/ PA Metre Cable/ Data cable and all the other types of telecom cable through HDPE pipe/casing- capping/false ceiling with laying/fixing of HDPEpipe/casing capping/PVC pipefor connecting/ interfacing various components and system integration. All materials for jointing and termination of power cable/CAT- 6 cable as per site requirement are to be supplied by contractor. This item also includes supply of RJ-45 connector with cap for terminating CAT-6 cable and (This includes releasing of existing cables, display boards if any as per the instruction of representative of Sr. DSTE/CKP at site).
Transportation and Laying of HDPE pipe as Kilometre per approved cable route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works or any other places as advised by site engineer. Both the end of duct should be sealed with end plugs before laying and should.
Installation, Testing and Commissioning of Numbers True color Outdoor Video Display (OVD) ofsize Pixel Resolution (WxH) 432x128 (6- linesingle face) with required MechanicalStructure and as per site condition. All fittingmaterials are to be supplied by thecontractor and to be inspected by authorized representative of Sr.DSTE/CKP. CKP-DIVN- S AND T/SOUTH EASTERN RLY
Installation, testing and commissioning of Numbers PDC as per RDSO Specification No. RDSO/SPN/TC/ 108/2019 Ver.0.0 with Amdt 1 or latest as supplied.
Installation, Testing and Commissioning of 3- Numbers Line single face at a glance display board as per RDSO specification No. RDSO/SPN/TC/108/ 2019 ver.0.0 with Amdt 1 or latest with contractors own material, as per site requirement & instruction of Engineer-in-charge.
Installation, testing and commissioning of Numbers single line double faced Platform Display boards for displaying information of single train as per RDSO Spec No: RDSO/SPN/TC/108/2019, Ver 1.0 or latest. This also includes supply of all other materials required for installation such as clamp, hanger, angles etc.
Splicing of Optical Fiber Core and routing in CORE joint closure/FDMS as per instruction of site Engineer.
Installation of Single Maintenance Free Earth Set pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/ Auguring/ Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site Engineer. CKP-DIVN- S AND T/SOUTH EASTERN RLY
Cutting of concrete platform to a depth of Metre 200 mm and width of 100 mm to lay DATA cable and power cable through DWC pipe of 63/50mm dia, Contractor has tore dress the cutting place into its original position without destroying the beauty after cable laying, This includes pedestal cutting and redress into its original position after cable laying wherever required, This includes supply of DWC pipe of 63/50mm dia, IS: 14930, Pt.-IImark. Inspection of all materials will be done by consignee before use. Note:Multiple data cable, Power cable or any other telecom cable will be layed through DWC pipe as per Railway's requirement in same cost as per the instruction of representative of Sr.DSTE/CKP at site.
Transportation and fixing of PVC Conduit Metre pipe/channel/casing caping on wall or structure with drawls of Telecom/Power/Data cable with proper finishing. This includes supply of fixing materials including flexible pipe/bend etc. as required during course of execution. Total 1847947.47
Item Breakup - B-Material Supply
Supply of Platform Data Controller (PDC) Numbers conforming to System requirement of RDSO Specification No. RDSO/SPN/TC/108/2019, Ver 1.0 or latest. (Inspection by RDSO)
Supply of three Line single side at a glance Numbers display board with all accessories as per RDSO Specification No. RDSO/SPN/TC/108/2019 Ver.0.0 Amdt.1 or latest. (Inspection by RDSO)
Supply of True color Outdoor Video Numbers Display(OVD) of Pixel Resolution (WxH) 432x128 (6-line single face) as per RDSO SpecificationNo. RDSO/ SPN/ TC/ 108/ 2019 Ver 0.0.or latest if any. (Inspection RDSO)
Supply of 6-line Single face True color Numbers Outdoor Video Display (OVD) of Pixel Resolution (WxH) 432x128 with all necessary accessories conforming to system requirements as per RDSO specification No.: RDSO/SPN/TC/108/2019, Ver 1.0 or latest. (Inspection by RDSO)
Supply of Single Line double faced Platform Numbers Display boards for displaying information of single train & all accessories as per RDSO Spec No: RDSO/SPN/TC/108/2019, Ver 1.0 or latest. (Inspection by RDSO)
Supply of STP (Shielded Twisted Pair) CAT-6 Metre Cable compliant with TIA/EIA-568-B2-1 or latest. (Inspection by representative of Sr. DSTE/CKP)
Supply of PVC insulated 3 Core 2.5 sq.mm Metre Single core Multi-strands copper conductor with ISI marked conforming to IS:694/2010 or latest. (Inspection by representative of Sr. DSTE/CKP) CKP-DIVN- S AND T/SOUTH EASTERN RLY
Supply of 25 mm (1 inch) PVC conduit pipe Metre rigid plain ended conduit size IS:9537 (part- 3) or latest and 9537 (Part-1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & minimum one socket at every 3 meter pipe. (Inspection by representative of Sr. DSTE/CKP)
Supply, commissioning of UPS 5 KVA capacity with battery bank for 1 hrs (ON Line) at rated load & battery trolley as per specification No.RDSO/PE/SPEC/PS/ 0023,(Rev. '0') 2001 Amdt 4 or latest. (Inspection by Representativ of Sr.DSTE/CKP.)
Supply of C series MCB 2 POLE 32 AMP with Numbers metal enclosure. Make: Schneider /Legrand/ L&T/ Havells or similar or better. (Inspection by representative of Sr. DSTE/CKP)
Supply, transportation, installation of 16A Numbers Single Pole MCB with cover, Make: Havells or similar or better. (Inspection by representative of Sr.DSTE/CKP).
Supply, transportation of PVC cable tray Numbers 1300.00 (trucking) 75 mm x 75 mm. (Inspection by representativeof Sr. DSTE/CKP).
Supply of 9U Rack with 19 inch standard Numbers dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D-Link or better. (Inspection by representative of Sr. DSTE/CKP)
Supply of HDPE pipe as per Specification No. Kilometre RDSO/SPN/TC/45/2013 Rev-2.0 or latest with OD/ID of size 50mm/42mm with suitable couplers, plugs, end caps, spacer, T band etc. as required during execution at the site. (Inspection by representative of Sr. DSTE/CKP)
Supply of 6 core fiber termination box with Numbers capacity of Ports: 6 ports, Suitable Adapter: SC/LC. (Inspection by Representative of Sr.DSTE/CKP).
Supply of SC to SC/LC Single Mode Numbers Simplex/Duplex Fibre Optic Patch Cable 5m length. (Inspection by representative of Sr.DSTE/CKP)
Supply of Spike Buster, Anchor/Havells or Numbers similar or better. (Inspection by representative of Sr.DSTE/CKP)
Supply of Power cable Jointing Box with Numbers jointing terminal. (Inspection by representative of Sr.DSTE/CKP).
Supply of RJ-45 connector. Make: D-link or Numbers better. (Inspection by representative of Sr. DSTE/CKP)
Supply of Fiber splice closure box suitable for Numbers 6 fiber. (Inspection by representativeof Sr.DSTE/CKP)
Supply of Fibre Distribution Management Numbers system (FDMS)/LIU for 12 Fiber complete with all accessories such as patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April'2007 or latest. This includes supply of installation accessories as per technical specification. (Inspection by representative of Sr. DSTE/CKP) CKP-DIVN- S AND T/SOUTH EASTERN RLY
Per Supply of Industrial Grade VDU for 24X7 Visual operation. VDU of screen size 42/43 Inch Display (2K). (Inspection by representative of Sr. Unit DSTE/CKP) (VDU)
Supply of basic material to construct unit Set Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30- 35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. (Inspection by RDSO) Total 18336283.94
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Annexure-1and2.pdf
ATTACHMENT
Annexure-L.pdf
ATTACHMENT
Annexure-MandN.pdf
ATTACHMENT
Anneure-V.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
AnnexureVIA.pdf
ATTACHMENT
Annexure-VI-B.pdf
ATTACHMENT
Annexure-Z.pdf
ATTACHMENT
TENDERFORMFirstSheet.pdf
ATTACHMENT
Gcc 2022
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11..pdf Gcc Advance Correction Slip
ATTACHMENT
Annexure-K.pdf
ATTACHMENT
SpecialConditionsofContract_1.pdf
ATTACHMENT
ColouredFinal_GCC_April-22_pdf_27.04.22.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11..pdf
ATTACHMENT
Download all tender documents and submit your bid