Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC CHAKKALAKKAL H KOTTAT P O | ₹2.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | - | - | Rejected-Technical L2 |
| 4 | Rejected-Technical | - | - | Rejected-Technical L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical L5 |
Tender Value
₹3.3 L
EMD Value
₹8,290
Closing Date
30 Dec 2024, 5:00 pmClosed
Asst. Engineer
LID EW Section Mala GP
Mini mast High mast light maintenance Mala GP
2024_LSGD_718421_4
T10/AE/LSGD/MALA/2024-25
Open Tender
Electrical Works
Item Rate
Mala G.P
Please refer Tender documents.
8 documents required · 8 mandatory
₹735
Yes
₹8,290
Yes
24 Apr 2025
23 Dec 2024
3 Jan 2025
23 Dec 2024
30 Dec 2024
23 Dec 2024
Amount
Electrical work
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
OD160328/2024-2025:Supply and providing 4mm^2 aluminium 2 core weather proof cable with suitable guy wire support for connecting power suppty from street main conductor from LT electric post which situated opposite to the main road.
OD160329/2024-2025:Supply and fixing 16A, 2pole, AC 3 rated power contactor with 160-220V, AC coil and giving connections as required. ( L&T MU 2P or equivalent)
OD160330/2024-2025:Supply and providing 240V, AC, Daily, Weekly, programmable electronic Crono Timer switch and giving connections as required for ON-OFF function. ( L&T 67DDTO or equivalent. )
OD160331/2024-2025:Supply and providing 2 pole moulded / plastic MCB enclosure for independant mounting of MCB /ELCB / isolator as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
OD160332/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 12x3mm brass nut and bolt .
OD160333/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt .
OD183471/2024-2025:labour Charges for Dismantling the control box cover of the Highmast pole after inserting the protection bracket into the slot of the pole , cleaning cleaning the rested portion of the gear ,cleaning and ,lubricating the rope, lowering the round arm luminaire garrage, cleaing ,painting if nesessary and making the same in good working condition.
OD183472/2024-2025:Labour and hiring Charges for Dismantling the burnt minimast lights on the round arm luminaire by providing scaffolding arrangement on tempo or using standby vehicle adopting safety measurements as per norm on the road side etc as required. using crane carriage vehicle of each pole etc along with spares in rigid on existing minimast pole.
OD234496/2024-2025:Supply and installation of dust and vermin proof wall mounting SMC Meter box suitable for fixing KSEB Meter cut out and nuetral link etc. hinged door construction for the front side, providing vision panelfor the meter compartment ,knock out out for cable entry and exit. GS-MB 6535 (inside 650x350x250 ) Sintex or Equivalent.
OD234509/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32 A, 415 V 2 way neutral Link mounted on DMC/SMC base)
OD234510/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32 A, HRC Fuse Base with HRC Fuse link)
OD234508/2024-2025:Charge for preparing test certificate and completion certificate for KSEB connection.
BOSS LIGHT (BID ID -2040905)
BENNY M G (BID ID -2039654)
GENERAL ELECTRIC SOLUTIONS (BID ID -2041655)
SANTO THOMAS M (BID ID -2041411)
Bidder Name
BIJU JOSE
BOSS LIGHT
GENERAL ELECTRIC SOLUTIONS
BENNY M G
SANTO THOMAS M
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1137025.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .